blob: c39ff6be78d4c98c4ce542cf83f218228bbec67a [file] [log] [blame]
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
* Copyright 2020-present Open Networking Foundation
*
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// FecPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
// Managed entity FEC performance monitoring history data
const FecPerformanceMonitoringHistoryDataClassID = ClassID(312) // 0x0138
var fecperformancemonitoringhistorydataBME *ManagedEntityDefinition
// FecPerformanceMonitoringHistoryData (Class ID: #312 / 0x0138)
// This ME collects PM data associated with PON downstream forward error correction (FEC) counters.
// Instances of this ME are created and deleted by the OLT.
//
// For a complete discussion of generic PM architecture, refer to clause I.4.
//
// Relationships
// An instance of this ME is associated with an instance of the ANI-G ME or an instance of the time
// and wavelength division multiplexing (TWDM) channel ME.
//
// Attributes
// Managed Entity Id
// This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
// implicitly linked to an instance of the ANI-G or a TWDM channel. (R, setbycreate) (mandatory)
// (2-bytes)
//
// Interval End Time
// This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1-byte)
//
// Threshold Data 1_2 Id
// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that
// contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold
// data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes)
//
// Corrected Bytes
// This attribute counts the number of bytes that were corrected by the FEC function. (R)
// (mandatory) (4-bytes)
//
// Corrected Code Words
// This attribute counts the code words that were corrected by the FEC function. (R) (mandatory)
// (4-bytes)
//
// Uncorrectable Code Words
// This attribute counts errored code words that could not be corrected by the FEC function. (R)
// (mandatory) (4-bytes)
//
// Total Code Words
// This attribute counts the total received code words. (R) (mandatory) (4-bytes)
//
// Fec Seconds
// This attribute counts seconds during which there was an FEC anomaly. (R) (mandatory) (2-bytes)
//
type FecPerformanceMonitoringHistoryData struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
// Attribute name constants
const FecPerformanceMonitoringHistoryData_IntervalEndTime = "IntervalEndTime"
const FecPerformanceMonitoringHistoryData_ThresholdData12Id = "ThresholdData12Id"
const FecPerformanceMonitoringHistoryData_CorrectedBytes = "CorrectedBytes"
const FecPerformanceMonitoringHistoryData_CorrectedCodeWords = "CorrectedCodeWords"
const FecPerformanceMonitoringHistoryData_UncorrectableCodeWords = "UncorrectableCodeWords"
const FecPerformanceMonitoringHistoryData_TotalCodeWords = "TotalCodeWords"
const FecPerformanceMonitoringHistoryData_FecSeconds = "FecSeconds"
func init() {
fecperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
Name: "FecPerformanceMonitoringHistoryData",
ClassID: FecPerformanceMonitoringHistoryDataClassID,
MessageTypes: mapset.NewSetWith(
Create,
Delete,
Get,
Set,
GetCurrentData,
),
AllowedAttributeMask: 0xfe00,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field(ManagedEntityID, PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
1: ByteField(FecPerformanceMonitoringHistoryData_IntervalEndTime, UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
2: Uint16Field(FecPerformanceMonitoringHistoryData_ThresholdData12Id, UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
3: Uint32Field(FecPerformanceMonitoringHistoryData_CorrectedBytes, CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
4: Uint32Field(FecPerformanceMonitoringHistoryData_CorrectedCodeWords, CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4),
5: Uint32Field(FecPerformanceMonitoringHistoryData_UncorrectableCodeWords, CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
6: Uint32Field(FecPerformanceMonitoringHistoryData_TotalCodeWords, CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6),
7: Uint16Field(FecPerformanceMonitoringHistoryData_FecSeconds, CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7),
},
Access: CreatedByOlt,
Support: UnknownSupport,
Alarms: AlarmMap{
0: "Corrected bytes",
1: "Corrected code words",
2: "Uncorrectable code words",
4: "FEC seconds",
},
}
}
// NewFecPerformanceMonitoringHistoryData (class ID 312) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewFecPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {
return NewManagedEntity(*fecperformancemonitoringhistorydataBME, params...)
}