| * Copyright 2021-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| |
| //Package adaptercoreonu provides the utility for onu devices, flows and statistics |
| package adaptercoreonu |
| |
| import ( |
| "context" |
| "errors" |
| "fmt" |
| "github.com/opencord/omci-lib-go" |
| me "github.com/opencord/omci-lib-go/generated" |
| "github.com/opencord/voltha-lib-go/v4/pkg/log" |
| "github.com/opencord/voltha-protos/v4/go/voltha" |
| "sync" |
| "time" |
| ) |
| |
| // general constants used for overall Metric Collection management |
| const ( |
| DefaultMetricCollectionFrequency = 15 * 60 // unit in seconds. This setting can be changed from voltha NBI PmConfig configuration |
| GroupMetricEnabled = true // This is READONLY and cannot be changed from VOLTHA NBI |
| DefaultFrequencyOverrideEnabled = true // This is READONLY and cannot be changed from VOLTHA NBI |
| FrequencyGranularity = 5 // The frequency (in seconds) has to be multiple of 5. This setting cannot changed later. |
| ) |
| |
| // OpticalPowerGroupMetrics are supported optical pm names |
| var OpticalPowerGroupMetrics = map[string]voltha.PmConfig_PmType{ |
| "ani_g_instance_id": voltha.PmConfig_CONTEXT, |
| "transmit_power": voltha.PmConfig_GAUGE, |
| "receive_power": voltha.PmConfig_GAUGE, |
| } |
| |
| // OpticalPowerGroupMetrics specific constants |
| const ( |
| OpticalPowerGroupMetricName = "OpticalPower" |
| OpticalPowerGroupMetricEnabled = true // This setting can be changed from voltha NBI PmConfig configuration |
| OpticalPowerMetricGroupCollectionFrequency = 5 * 60 // unit in seconds. This setting can be changed from voltha NBI PmConfig configuration |
| ) |
| |
| // UniStatusGroupMetrics are supported UNI status names |
| var UniStatusGroupMetrics = map[string]voltha.PmConfig_PmType{ |
| "uni_port_no": voltha.PmConfig_CONTEXT, |
| "ethernet_type": voltha.PmConfig_GAUGE, |
| "oper_status": voltha.PmConfig_GAUGE, |
| "uni_admin_state": voltha.PmConfig_GAUGE, |
| } |
| |
| // UniStatusGroupMetrics specific constants |
| const ( |
| UniStatusGroupMetricName = "UniStatus" |
| UniStatusGroupMetricEnabled = true // This setting can be changed from voltha NBI PmConfig configuration |
| UniStatusMetricGroupCollectionFrequency = 5 * 60 // unit in seconds. This setting can be changed from voltha NBI PmConfig configuration |
| ) |
| |
| type groupMetric struct { |
| groupName string |
| enabled bool |
| frequency uint32 // valid only if FrequencyOverride is enabled. |
| metricMap map[string]voltha.PmConfig_PmType |
| nextCollectionInterval time.Time // valid only if FrequencyOverride is enabled. |
| } |
| |
| type standaloneMetric struct { |
| metricName string |
| enabled bool |
| frequency uint32 // valid only if FrequencyOverride is enabled. |
| nextCollectionInterval time.Time // valid only if FrequencyOverride is enabled. |
| } |
| |
| type onuMetricsManager struct { |
| pDeviceHandler *deviceHandler |
| |
| commMetricsChan chan Message |
| opticalMetricsChan chan me.AttributeValueMap |
| uniStatusMetricsChan chan me.AttributeValueMap |
| |
| groupMetricMap map[string]*groupMetric |
| standaloneMetricMap map[string]*standaloneMetric |
| |
| stopProcessingOmciResponses chan bool |
| |
| nextGlobalMetricCollectionTime time.Time // valid only if pmConfig.FreqOverride is set to false. |
| |
| onuMetricsManagerLock sync.RWMutex |
| } |
| |
| // newonuMetricsManager returns a new instance of the newonuMetricsManager |
| // Note that none of the context stored internally in onuMetricsManager is backed up on KV store for resiliency. |
| // Metric collection is not a critical operation that needs support for resiliency. On adapter restart, some context |
| // could be lost (except for Device.PmConfigs which is backed up the rw-core on KV store). An example of information |
| // that is lost on adapter restart is nextCollectionInterval time. |
| func newonuMetricsManager(ctx context.Context, dh *deviceHandler) *onuMetricsManager { |
| |
| var metricsManager onuMetricsManager |
| logger.Debugw(ctx, "init-onuMetricsManager", log.Fields{"device-id": dh.deviceID}) |
| metricsManager.pDeviceHandler = dh |
| |
| metricsManager.commMetricsChan = make(chan Message) |
| metricsManager.opticalMetricsChan = make(chan me.AttributeValueMap) |
| metricsManager.uniStatusMetricsChan = make(chan me.AttributeValueMap) |
| metricsManager.stopProcessingOmciResponses = make(chan bool) |
| |
| metricsManager.groupMetricMap = make(map[string]*groupMetric) |
| metricsManager.standaloneMetricMap = make(map[string]*standaloneMetric) |
| |
| if dh.pmConfigs == nil { // dh.pmConfigs is NOT nil if adapter comes back from a restart. We should NOT go back to defaults in this case |
| dh.pmConfigs = &voltha.PmConfigs{} |
| dh.pmConfigs.Id = dh.deviceID |
| dh.pmConfigs.DefaultFreq = DefaultMetricCollectionFrequency |
| dh.pmConfigs.Grouped = GroupMetricEnabled |
| dh.pmConfigs.FreqOverride = DefaultFrequencyOverrideEnabled |
| |
| // Populate group metrics. |
| // Lets populate irrespective of GroupMetricEnabled is true or not. |
| // The group metrics collection will decided on this flag later |
| |
| // Populate optical power group metrics |
| var opPmConfigSlice []*voltha.PmConfig |
| for k, v := range OpticalPowerGroupMetrics { |
| opPmConfigSlice = append(opPmConfigSlice, &voltha.PmConfig{Name: k, Type: v}) |
| } |
| opticalPowerGroupMetric := voltha.PmGroupConfig{ |
| GroupName: OpticalPowerGroupMetricName, |
| Enabled: OpticalPowerGroupMetricEnabled, |
| GroupFreq: OpticalPowerMetricGroupCollectionFrequency, |
| Metrics: opPmConfigSlice, |
| } |
| dh.pmConfigs.Groups = append(dh.pmConfigs.Groups, &opticalPowerGroupMetric) |
| |
| // Populate uni status group metrics |
| var uniStPmConfigSlice []*voltha.PmConfig |
| for k, v := range UniStatusGroupMetrics { |
| uniStPmConfigSlice = append(uniStPmConfigSlice, &voltha.PmConfig{Name: k, Type: v}) |
| } |
| uniStatusGroupMetric := voltha.PmGroupConfig{ |
| GroupName: UniStatusGroupMetricName, |
| Enabled: UniStatusGroupMetricEnabled, |
| GroupFreq: UniStatusMetricGroupCollectionFrequency, |
| Metrics: uniStPmConfigSlice, |
| } |
| dh.pmConfigs.Groups = append(dh.pmConfigs.Groups, &uniStatusGroupMetric) |
| |
| // Add standalone metric (if present) after this (will be added to dh.pmConfigs.Metrics) |
| } |
| |
| // Populate local group metric structures |
| for _, g := range dh.pmConfigs.Groups { |
| metricsManager.groupMetricMap[g.GroupName] = &groupMetric{ |
| groupName: g.GroupName, |
| enabled: g.Enabled, |
| frequency: g.GroupFreq, |
| } |
| switch g.GroupName { |
| case OpticalPowerGroupMetricName: |
| metricsManager.groupMetricMap[g.GroupName].metricMap = OpticalPowerGroupMetrics |
| case UniStatusGroupMetricName: |
| metricsManager.groupMetricMap[g.GroupName].metricMap = UniStatusGroupMetrics |
| |
| default: |
| logger.Errorw(ctx, "unhandled-group-name", log.Fields{"groupName": g.GroupName}) |
| } |
| } |
| |
| // Populate local standalone metric structures |
| for _, m := range dh.pmConfigs.Metrics { |
| metricsManager.standaloneMetricMap[m.Name] = &standaloneMetric{ |
| metricName: m.Name, |
| enabled: m.Enabled, |
| frequency: m.SampleFreq, |
| } |
| switch m.Name { |
| // None exist as of now. Add when available. |
| default: |
| logger.Errorw(ctx, "unhandled-metric-name", log.Fields{"metricName": m.Name}) |
| } |
| } |
| |
| // initialize the next metric collection intervals. |
| metricsManager.initializeMetricCollectionTime(ctx) |
| logger.Info(ctx, "init-onuMetricsManager completed", log.Fields{"device-id": dh.deviceID}) |
| return &metricsManager |
| } |
| |
| func (mm *onuMetricsManager) initializeMetricCollectionTime(ctx context.Context) { |
| if mm.pDeviceHandler.pmConfigs.FreqOverride { |
| // If mm.pDeviceHandler.pmConfigs.FreqOverride is set to true, then group/standalone metric specific interval applies |
| mm.onuMetricsManagerLock.Lock() |
| defer mm.onuMetricsManagerLock.Unlock() |
| for _, v := range mm.groupMetricMap { |
| if v.enabled { |
| v.nextCollectionInterval = time.Now().Add(time.Duration(v.frequency) * time.Second) |
| } |
| } |
| |
| for _, v := range mm.standaloneMetricMap { |
| if v.enabled { |
| v.nextCollectionInterval = time.Now().Add(time.Duration(v.frequency) * time.Second) |
| } |
| } |
| } else { |
| // If mm.pDeviceHandler.pmConfigs.FreqOverride is set to false, then overall metric specific interval applies |
| mm.nextGlobalMetricCollectionTime = time.Now().Add(time.Duration(mm.pDeviceHandler.pmConfigs.DefaultFreq) * time.Second) |
| } |
| logger.Infow(ctx, "initialized standalone group/metric collection time", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| } |
| |
| func (mm *onuMetricsManager) updateDefaultFrequency(ctx context.Context, pmConfigs *voltha.PmConfigs) error { |
| // Verify that the configured DefaultFrequency is > 0 and is a multiple of FrequencyGranularity |
| if pmConfigs.DefaultFreq == 0 && pmConfigs.DefaultFreq%FrequencyGranularity != 0 { |
| logger.Errorf(ctx, "frequency-%u-should-be-a-multiple-of-%u", pmConfigs.DefaultFreq, FrequencyGranularity) |
| return fmt.Errorf("frequency-%d-should-be-a-multiple-of-%d", pmConfigs.DefaultFreq, FrequencyGranularity) |
| } |
| mm.pDeviceHandler.pmConfigs.DefaultFreq = pmConfigs.DefaultFreq |
| // re-set the nextGlobalMetricCollectionTime based on the new DefaultFreq |
| mm.nextGlobalMetricCollectionTime = time.Now().Add(time.Duration(mm.pDeviceHandler.pmConfigs.DefaultFreq) * time.Second) |
| logger.Debugw(ctx, "frequency-updated--new-frequency", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "frequency": mm.pDeviceHandler.pmConfigs.DefaultFreq}) |
| return nil |
| } |
| |
| func (mm *onuMetricsManager) updateGroupFreq(ctx context.Context, aGroupName string, pmConfigs *voltha.PmConfigs) error { |
| var newGroupFreq uint32 |
| found := false |
| groupSliceIdx := 0 |
| var group *voltha.PmGroupConfig |
| for groupSliceIdx, group = range pmConfigs.Groups { |
| if group.GroupName == aGroupName { |
| if group.GroupFreq != 0 { // freq 0 not allowed |
| newGroupFreq = group.GroupFreq |
| found = true |
| break |
| } |
| } |
| } |
| // if not found update group freq and next collection interval for the group |
| if !found { |
| logger.Errorw(ctx, "group name not found", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "groupName": aGroupName}) |
| return fmt.Errorf("group-name-not-found-%v", aGroupName) |
| } |
| |
| updated := false |
| mm.onuMetricsManagerLock.Lock() |
| defer mm.onuMetricsManagerLock.Unlock() |
| for k, v := range mm.groupMetricMap { |
| if k == aGroupName && newGroupFreq != 0 { // freq 0 not allowed |
| v.frequency = newGroupFreq |
| // update internal pm config |
| mm.pDeviceHandler.pmConfigs.Groups[groupSliceIdx].GroupFreq = newGroupFreq |
| // Also updated the next group metric collection time from now |
| v.nextCollectionInterval = time.Now().Add(time.Duration(newGroupFreq) * time.Second) |
| updated = true |
| logger.Infow(ctx, "group frequency updated", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "newGroupFreq": newGroupFreq, "groupName": aGroupName}) |
| } |
| } |
| if !updated { |
| logger.Errorw(ctx, "group frequency not updated", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "newGroupFreq": newGroupFreq, "groupName": aGroupName}) |
| return fmt.Errorf("internal-error-during-group-freq-update--groupname-%s-freq-%d", aGroupName, newGroupFreq) |
| } |
| return nil |
| } |
| |
| func (mm *onuMetricsManager) updateMetricFreq(ctx context.Context, aMetricName string, pmConfigs *voltha.PmConfigs) error { |
| var newMetricFreq uint32 |
| found := false |
| metricSliceIdx := 0 |
| var metric *voltha.PmConfig |
| for metricSliceIdx, metric = range pmConfigs.Metrics { |
| if metric.Name == aMetricName { |
| if metric.SampleFreq != 0 { // freq 0 not allowed |
| newMetricFreq = metric.SampleFreq |
| found = true |
| break |
| } |
| } |
| } |
| if !found { |
| logger.Errorw(ctx, "metric name not found", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "metricName": aMetricName}) |
| return fmt.Errorf("metric-name-not-found-%v", aMetricName) |
| } |
| |
| updated := false |
| mm.onuMetricsManagerLock.Lock() |
| defer mm.onuMetricsManagerLock.Unlock() |
| for k, v := range mm.groupMetricMap { |
| if k == aMetricName && newMetricFreq != 0 { |
| v.frequency = newMetricFreq |
| // update internal pm config |
| mm.pDeviceHandler.pmConfigs.Metrics[metricSliceIdx].SampleFreq = newMetricFreq |
| // Also updated the next standalone metric collection time from now |
| v.nextCollectionInterval = time.Now().Add(time.Duration(newMetricFreq) * time.Second) |
| updated = true |
| logger.Infow(ctx, "metric frequency updated", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "newMetricFreq": newMetricFreq, "aMetricName": aMetricName}) |
| } |
| } |
| if !updated { |
| logger.Errorw(ctx, "metric frequency not updated", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "newMetricFreq": newMetricFreq, "aMetricName": aMetricName}) |
| return fmt.Errorf("internal-error-during-standalone-metric-update--matricnane-%s-freq-%d", aMetricName, newMetricFreq) |
| } |
| return nil |
| } |
| |
| func (mm *onuMetricsManager) updateGroupSupport(ctx context.Context, aGroupName string, pmConfigs *voltha.PmConfigs) error { |
| groupSliceIdx := 0 |
| var group *voltha.PmGroupConfig |
| |
| for groupSliceIdx, group = range pmConfigs.Groups { |
| if group.GroupName == aGroupName { |
| break |
| } |
| } |
| if group == nil { |
| logger.Errorw(ctx, "group metric not found", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "groupName": aGroupName}) |
| return fmt.Errorf("group-not-found--groupName-%s", aGroupName) |
| } |
| |
| updated := false |
| mm.onuMetricsManagerLock.Lock() |
| defer mm.onuMetricsManagerLock.Unlock() |
| for k, v := range mm.groupMetricMap { |
| if k == aGroupName && v.enabled != group.Enabled { |
| mm.pDeviceHandler.pmConfigs.Groups[groupSliceIdx].Enabled = group.Enabled |
| v.enabled = group.Enabled |
| // If the group is now enabled and frequency override is enabled, set the next group metric collection time |
| if group.Enabled && mm.pDeviceHandler.pmConfigs.FreqOverride { |
| v.nextCollectionInterval = time.Now().Add(time.Duration(v.frequency) * time.Second) |
| } |
| updated = true |
| logger.Infow(ctx, "group metric support updated", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "groupName": aGroupName, "enabled": group.Enabled}) |
| } |
| } |
| |
| if !updated { |
| logger.Errorw(ctx, "group metric support not updated", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "groupName": aGroupName}) |
| return fmt.Errorf("internal-error-during-group-support-update--groupName-%s", aGroupName) |
| } |
| return nil |
| } |
| |
| func (mm *onuMetricsManager) updateMetricSupport(ctx context.Context, aMetricName string, pmConfigs *voltha.PmConfigs) error { |
| metricSliceIdx := 0 |
| var metric *voltha.PmConfig |
| |
| for metricSliceIdx, metric = range pmConfigs.Metrics { |
| if metric.Name == aMetricName { |
| break |
| } |
| } |
| |
| if metric == nil { |
| logger.Errorw(ctx, "standalone metric not found", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "metricName": aMetricName}) |
| return fmt.Errorf("metric-not-found--metricname-%s", aMetricName) |
| } |
| |
| updated := false |
| mm.onuMetricsManagerLock.Lock() |
| defer mm.onuMetricsManagerLock.Unlock() |
| for k, v := range mm.standaloneMetricMap { |
| if k == aMetricName && v.enabled != metric.Enabled { |
| mm.pDeviceHandler.pmConfigs.Metrics[metricSliceIdx].Enabled = metric.Enabled |
| v.enabled = metric.Enabled |
| // If the standalone metric is now enabled and frequency override is enabled, set the next metric collection time |
| if metric.Enabled && mm.pDeviceHandler.pmConfigs.FreqOverride { |
| v.nextCollectionInterval = time.Now().Add(time.Duration(v.frequency) * time.Second) |
| } |
| updated = true |
| logger.Infow(ctx, "standalone metric support updated", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "metricName": aMetricName, "enabled": metric.Enabled}) |
| } |
| } |
| if !updated { |
| logger.Errorw(ctx, "standalone metric support not updated", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "metricName": aMetricName}) |
| return fmt.Errorf("internal-error-during-standalone-support-update--metricname-%s", aMetricName) |
| } |
| return nil |
| } |
| |
| func (mm *onuMetricsManager) collectAllGroupAndStandaloneMetrics(ctx context.Context) { |
| if mm.pDeviceHandler.pmConfigs.Grouped { // metrics are managed as a group. |
| go mm.collectAllGroupMetrics(ctx) |
| } else { |
| go mm.collectAllStandaloneMetrics(ctx) |
| } |
| } |
| |
| func (mm *onuMetricsManager) collectAllGroupMetrics(ctx context.Context) { |
| go func() { |
| logger.Debug(ctx, "startCollector before collecting optical metrics") |
| metricInfo := mm.collectOpticalMetrics(ctx) |
| if metricInfo != nil { |
| mm.publishMetrics(ctx, metricInfo) |
| } |
| }() |
| |
| go func() { |
| logger.Debug(ctx, "startCollector before collecting uni metrics") |
| metricInfo := mm.collectUniStatusMetrics(ctx) |
| if metricInfo != nil { |
| mm.publishMetrics(ctx, metricInfo) |
| } |
| }() |
| |
| // Add more here |
| } |
| |
| func (mm *onuMetricsManager) collectAllStandaloneMetrics(ctx context.Context) { |
| // None exists as of now, add when available here |
| } |
| |
| func (mm *onuMetricsManager) collectGroupMetric(ctx context.Context, groupName string) { |
| switch groupName { |
| case OpticalPowerGroupMetricName: |
| go func() { |
| if mi := mm.collectOpticalMetrics(ctx); mm != nil { |
| mm.publishMetrics(ctx, mi) |
| } |
| }() |
| case UniStatusGroupMetricName: |
| go func() { |
| if mi := mm.collectUniStatusMetrics(ctx); mm != nil { |
| mm.publishMetrics(ctx, mi) |
| } |
| }() |
| default: |
| logger.Errorw(ctx, "unhandled group metric name", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "groupName": groupName}) |
| } |
| } |
| |
| func (mm *onuMetricsManager) collectStandaloneMetric(ctx context.Context, metricName string) { |
| switch metricName { |
| // None exist as of now, add when available |
| default: |
| logger.Errorw(ctx, "unhandled standalone metric name", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "metricName": metricName}) |
| } |
| } |
| |
| // collectOpticalMetrics collects groups metrics related to optical power from ani-g ME. |
| func (mm *onuMetricsManager) collectOpticalMetrics(ctx context.Context) []*voltha.MetricInformation { |
| logger.Debugw(ctx, "collectOpticalMetrics", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| |
| mm.onuMetricsManagerLock.RLock() |
| if !mm.groupMetricMap[OpticalPowerGroupMetricName].enabled { |
| mm.onuMetricsManagerLock.RUnlock() |
| logger.Debugw(ctx, "optical power group metric is not enabled", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| return nil |
| } |
| mm.onuMetricsManagerLock.RUnlock() |
| |
| var metricInfoSlice []*voltha.MetricInformation |
| metricsContext := make(map[string]string) |
| metricsContext["onuID"] = fmt.Sprintf("%d", mm.pDeviceHandler.device.ProxyAddress.OnuId) |
| metricsContext["intfID"] = fmt.Sprintf("%d", mm.pDeviceHandler.device.ProxyAddress.ChannelId) |
| metricsContext["devicetype"] = mm.pDeviceHandler.DeviceType |
| |
| raisedTs := time.Now().Unix() |
| mmd := voltha.MetricMetaData{ |
| Title: OpticalPowerGroupMetricName, |
| Ts: float64(raisedTs), |
| Context: metricsContext, |
| DeviceId: mm.pDeviceHandler.deviceID, |
| LogicalDeviceId: mm.pDeviceHandler.logicalDeviceID, |
| SerialNo: mm.pDeviceHandler.device.SerialNumber, |
| } |
| |
| // get the ANI-G instance IDs |
| anigInstKeys := mm.pDeviceHandler.pOnuOmciDevice.pOnuDB.getSortedInstKeys(ctx, me.AniGClassID) |
| loop: |
| for _, anigInstID := range anigInstKeys { |
| var meAttributes me.AttributeValueMap |
| opticalMetrics := make(map[string]float32) |
| // Get the ANI-G instance optical power attributes |
| requestedAttributes := me.AttributeValueMap{"OpticalSignalLevel": 0, "TransmitOpticalLevel": 0} |
| if meInstance := mm.pDeviceHandler.pOnuOmciDevice.PDevOmciCC.sendGetMe(ctx, me.AniGClassID, anigInstID, requestedAttributes, ConstDefaultOmciTimeout, true, mm.commMetricsChan); meInstance != nil { |
| select { |
| case meAttributes = <-mm.opticalMetricsChan: |
| logger.Debugw(ctx, "received optical metrics", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| case <-time.After(time.Duration(ConstDefaultOmciTimeout) * time.Second): |
| logger.Errorw(ctx, "timeout waiting for omci-get response for uni status", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| // The metrics will be empty in this case |
| break loop |
| } |
| // Populate metric only if it was enabled. |
| for k := range OpticalPowerGroupMetrics { |
| switch k { |
| case "ani_g_instance_id": |
| if val, ok := meAttributes["ManagedEntityId"]; ok && val != nil { |
| opticalMetrics[k] = float32(val.(uint16)) |
| } |
| case "transmit_power": |
| if val, ok := meAttributes["TransmitOpticalLevel"]; ok && val != nil { |
| opticalMetrics[k] = float32(val.(uint16)) |
| } |
| case "receive_power": |
| if val, ok := meAttributes["OpticalSignalLevel"]; ok && val != nil { |
| opticalMetrics[k] = float32(val.(uint16)) |
| } |
| default: |
| // do nothing |
| } |
| } |
| } |
| // create slice of metrics given that there could be more than one ANI-G instance and |
| // optical metrics are collected per ANI-G instance |
| metricInfo := voltha.MetricInformation{Metadata: &mmd, Metrics: opticalMetrics} |
| metricInfoSlice = append(metricInfoSlice, &metricInfo) |
| } |
| |
| return metricInfoSlice |
| } |
| |
| // collectUniStatusMetrics collects UNI status group metric from various MEs (uni-g, pptp and veip). |
| // nolint: gocyclo |
| func (mm *onuMetricsManager) collectUniStatusMetrics(ctx context.Context) []*voltha.MetricInformation { |
| logger.Debugw(ctx, "collectUniStatusMetrics", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| mm.onuMetricsManagerLock.RLock() |
| if !mm.groupMetricMap[UniStatusGroupMetricName].enabled { |
| mm.onuMetricsManagerLock.RUnlock() |
| logger.Debugw(ctx, "uni status group metric is not enabled", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| return nil |
| } |
| mm.onuMetricsManagerLock.RUnlock() |
| |
| var metricInfoSlice []*voltha.MetricInformation |
| metricsContext := make(map[string]string) |
| metricsContext["onuID"] = fmt.Sprintf("%d", mm.pDeviceHandler.device.ProxyAddress.OnuId) |
| metricsContext["intfID"] = fmt.Sprintf("%d", mm.pDeviceHandler.device.ProxyAddress.ChannelId) |
| metricsContext["devicetype"] = mm.pDeviceHandler.DeviceType |
| |
| raisedTs := time.Now().Unix() |
| mmd := voltha.MetricMetaData{ |
| Title: "UniStatus", // Is this ok to hard code? |
| Ts: float64(raisedTs), |
| Context: metricsContext, |
| DeviceId: mm.pDeviceHandler.deviceID, |
| LogicalDeviceId: mm.pDeviceHandler.logicalDeviceID, |
| SerialNo: mm.pDeviceHandler.device.SerialNumber, |
| } |
| |
| // get the UNI-G instance IDs |
| unigInstKeys := mm.pDeviceHandler.pOnuOmciDevice.pOnuDB.getSortedInstKeys(ctx, me.UniGClassID) |
| loop1: |
| for _, unigInstID := range unigInstKeys { |
| // TODO: Include additional information in the voltha.MetricMetaData - like portno, uni-id, instance-id |
| // to uniquely identify this ME instance and also to correlate the ME instance to physical instance |
| unigMetrics := make(map[string]float32) |
| var meAttributes me.AttributeValueMap |
| // Get the UNI-G instance optical power attributes |
| requestedAttributes := me.AttributeValueMap{"AdministrativeState": 0} |
| if meInstance := mm.pDeviceHandler.pOnuOmciDevice.PDevOmciCC.sendGetMe(ctx, me.UniGClassID, unigInstID, requestedAttributes, ConstDefaultOmciTimeout, true, mm.commMetricsChan); meInstance != nil { |
| // Wait for metrics or timeout |
| select { |
| case meAttributes = <-mm.uniStatusMetricsChan: |
| logger.Debugw(ctx, "received uni-g metrics", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| case <-time.After(time.Duration(ConstDefaultOmciTimeout) * time.Second): |
| logger.Errorw(ctx, "timeout waiting for omci-get response for uni status", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| // The metrics could be empty in this case |
| break loop1 |
| } |
| // Populate metric only if it was enabled. |
| for k := range UniStatusGroupMetrics { |
| switch k { |
| case "uni_admin_state": |
| if val, ok := meAttributes["AdministrativeState"]; ok && val != nil { |
| unigMetrics[k] = float32(val.(byte)) |
| } |
| default: |
| // do nothing |
| } |
| } |
| var entityID uint32 |
| if val, ok := meAttributes["ManagedEntityId"]; ok && val != nil { |
| entityID = uint32(val.(uint16)) |
| } |
| // TODO: Rlock needed for reading uniEntityMap? |
| if uniPort, ok := mm.pDeviceHandler.uniEntityMap[entityID]; ok && uniPort != nil { |
| unigMetrics["uni_port_no"] = float32(uniPort.portNo) |
| } |
| // create slice of metrics given that there could be more than one UNI-G instance |
| metricInfo := voltha.MetricInformation{Metadata: &mmd, Metrics: unigMetrics} |
| metricInfoSlice = append(metricInfoSlice, &metricInfo) |
| } |
| } |
| |
| // get the PPTP instance IDs |
| pptpInstKeys := mm.pDeviceHandler.pOnuOmciDevice.pOnuDB.getSortedInstKeys(ctx, me.PhysicalPathTerminationPointEthernetUniClassID) |
| loop2: |
| for _, pptpInstID := range pptpInstKeys { |
| // TODO: Include additional information in the voltha.MetricMetaData - like portno, uni-id, instance-id |
| // to uniquely identify this ME instance and also to correlate the ME instance to physical instance |
| var meAttributes me.AttributeValueMap |
| pptpMetrics := make(map[string]float32) |
| |
| requestedAttributes := me.AttributeValueMap{"SensedType": 0, "OperationalState": 0, "AdministrativeState": 0} |
| if meInstance := mm.pDeviceHandler.pOnuOmciDevice.PDevOmciCC.sendGetMe(ctx, me.PhysicalPathTerminationPointEthernetUniClassID, pptpInstID, requestedAttributes, ConstDefaultOmciTimeout, true, mm.commMetricsChan); meInstance != nil { |
| // Wait for metrics or timeout |
| select { |
| case meAttributes = <-mm.uniStatusMetricsChan: |
| logger.Debugw(ctx, "received pptp metrics", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| case <-time.After(time.Duration(ConstDefaultOmciTimeout) * time.Second): |
| logger.Errorw(ctx, "timeout waiting for omci-get response for uni status", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| // The metrics could be empty in this case |
| break loop2 |
| } |
| |
| // Populate metric only if it was enabled. |
| for k := range UniStatusGroupMetrics { |
| switch k { |
| case "ethernet_type": |
| if val, ok := meAttributes["SensedType"]; ok && val != nil { |
| pptpMetrics[k] = float32(val.(byte)) |
| } |
| case "oper_status": |
| if val, ok := meAttributes["OperationalState"]; ok && val != nil { |
| pptpMetrics[k] = float32(val.(byte)) |
| } |
| case "uni_admin_state": |
| if val, ok := meAttributes["AdministrativeState"]; ok && val != nil { |
| pptpMetrics[k] = float32(val.(byte)) |
| } |
| default: |
| // do nothing |
| } |
| } |
| } |
| var entityID uint32 |
| if val, ok := meAttributes["ManagedEntityId"]; ok && val != nil { |
| entityID = uint32(val.(uint16)) |
| } |
| // TODO: Rlock needed for reading uniEntityMap? |
| if uniPort, ok := mm.pDeviceHandler.uniEntityMap[entityID]; ok && uniPort != nil { |
| pptpMetrics["uni_port_no"] = float32(uniPort.portNo) |
| } |
| |
| // create slice of metrics given that there could be more than one PPTP instance and |
| metricInfo := voltha.MetricInformation{Metadata: &mmd, Metrics: pptpMetrics} |
| metricInfoSlice = append(metricInfoSlice, &metricInfo) |
| } |
| |
| // get the VEIP instance IDs |
| veipInstKeys := mm.pDeviceHandler.pOnuOmciDevice.pOnuDB.getSortedInstKeys(ctx, me.VirtualEthernetInterfacePointClassID) |
| loop3: |
| for _, veipInstID := range veipInstKeys { |
| // TODO: Include additional information in the voltha.MetricMetaData - like portno, uni-id, instance-id |
| // to uniquely identify this ME instance and also to correlate the ME instance to physical instance |
| var meAttributes me.AttributeValueMap |
| veipMetrics := make(map[string]float32) |
| |
| requestedAttributes := me.AttributeValueMap{"OperationalState": 0, "AdministrativeState": 0} |
| if meInstance := mm.pDeviceHandler.pOnuOmciDevice.PDevOmciCC.sendGetMe(ctx, me.VirtualEthernetInterfacePointClassID, veipInstID, requestedAttributes, ConstDefaultOmciTimeout, true, mm.commMetricsChan); meInstance != nil { |
| // Wait for metrics or timeout |
| select { |
| case meAttributes = <-mm.uniStatusMetricsChan: |
| logger.Debugw(ctx, "received veip metrics", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| case <-time.After(time.Duration(ConstDefaultOmciTimeout) * time.Second): |
| logger.Errorw(ctx, "timeout waiting for omci-get response for uni status", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| // The metrics could be empty in this case |
| break loop3 |
| } |
| |
| // Populate metric only if it was enabled. |
| for k := range UniStatusGroupMetrics { |
| switch k { |
| case "oper_status": |
| if val, ok := meAttributes["OperationalState"]; ok && val != nil { |
| veipMetrics[k] = float32(val.(byte)) |
| } |
| case "uni_admin_state": |
| if val, ok := meAttributes["AdministrativeState"]; ok && val != nil { |
| veipMetrics[k] = float32(val.(byte)) |
| } |
| default: |
| // do nothing |
| } |
| } |
| } |
| |
| var entityID uint32 |
| if val, ok := meAttributes["ManagedEntityId"]; ok && val != nil { |
| entityID = uint32(meAttributes["ManagedEntityId"].(uint16)) |
| } |
| // TODO: Rlock needed for reading uniEntityMap? |
| if uniPort, ok := mm.pDeviceHandler.uniEntityMap[entityID]; ok && uniPort != nil { |
| veipMetrics["uni_port_no"] = float32(uniPort.portNo) |
| } |
| |
| // create slice of metrics given that there could be more than one VEIP instance |
| metricInfo := voltha.MetricInformation{Metadata: &mmd, Metrics: veipMetrics} |
| metricInfoSlice = append(metricInfoSlice, &metricInfo) |
| } |
| |
| return metricInfoSlice |
| } |
| |
| // publishMetrics publishes the metrics on kafka |
| func (mm *onuMetricsManager) publishMetrics(ctx context.Context, metricInfo []*voltha.MetricInformation) { |
| var ke voltha.KpiEvent2 |
| ts := time.Now().Unix() |
| ke.SliceData = metricInfo |
| ke.Type = voltha.KpiEventType_slice |
| ke.Ts = float64(ts) |
| |
| if err := mm.pDeviceHandler.EventProxy.SendKpiEvent(ctx, "STATS_EVENT", &ke, voltha.EventCategory_EQUIPMENT, voltha.EventSubCategory_ONU, ts); err != nil { |
| logger.Errorw(ctx, "failed-to-send-pon-stats", log.Fields{"err": err}) |
| } |
| } |
| |
| func (mm *onuMetricsManager) processOmciMessages(ctx context.Context) { |
| logger.Infow(ctx, "Start routine to process OMCI-GET messages for device-id", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| // Flush metric collection channels to be safe. |
| // It is possible that there is stale data on this channel if the processOmciMessages routine |
| // is stopped right after issuing a OMCI-GET request and started again. |
| // The processOmciMessages routine will get stopped if startCollector routine (in device_handler.go) |
| // is stopped - as a result of ONU going down. |
| mm.flushMetricCollectionChannels(ctx) |
| |
| for { |
| select { |
| case <-mm.stopProcessingOmciResponses: // stop this routine |
| logger.Infow(ctx, "Stop routine to process OMCI-GET messages for device-id", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| return |
| case message, ok := <-mm.commMetricsChan: |
| if !ok { |
| logger.Errorw(ctx, "Message couldn't be read from channel", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| continue |
| } |
| logger.Debugw(ctx, "Received message on ONU metrics channel", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| |
| switch message.Type { |
| case OMCI: |
| msg, _ := message.Data.(OmciMessage) |
| mm.handleOmciMessage(ctx, msg) |
| default: |
| logger.Warn(ctx, "Unknown message type received", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "message.Type": message.Type}) |
| } |
| } |
| } |
| } |
| |
| func (mm *onuMetricsManager) handleOmciMessage(ctx context.Context, msg OmciMessage) { |
| logger.Debugw(ctx, "omci Msg", log.Fields{"device-id": mm.pDeviceHandler.deviceID, |
| "msgType": msg.OmciMsg.MessageType, "msg": msg}) |
| switch msg.OmciMsg.MessageType { |
| case omci.GetResponseType: |
| //TODO: error handling |
| _ = mm.handleOmciGetResponseMessage(ctx, msg) |
| |
| default: |
| logger.Warnw(ctx, "Unknown Message Type", log.Fields{"msgType": msg.OmciMsg.MessageType}) |
| |
| } |
| } |
| |
| func (mm *onuMetricsManager) handleOmciGetResponseMessage(ctx context.Context, msg OmciMessage) error { |
| msgLayer := (*msg.OmciPacket).Layer(omci.LayerTypeGetResponse) |
| if msgLayer == nil { |
| logger.Errorw(ctx, "omci Msg layer could not be detected for GetResponse - handling stopped", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| return fmt.Errorf("omci Msg layer could not be detected for GetResponse - handling stopped: %s", mm.pDeviceHandler.deviceID) |
| } |
| msgObj, msgOk := msgLayer.(*omci.GetResponse) |
| if !msgOk { |
| logger.Errorw(ctx, "omci Msg layer could not be assigned for GetResponse - handling stopped", log.Fields{"device-id": mm.pDeviceHandler.deviceID}) |
| return fmt.Errorf("omci Msg layer could not be assigned for GetResponse - handling stopped: %s", mm.pDeviceHandler.deviceID) |
| } |
| logger.Debugw(ctx, "OMCI GetResponse Data", log.Fields{"device-id": mm.pDeviceHandler.deviceID, "data-fields": msgObj}) |
| if msgObj.Result == me.Success { |
| meAttributes := msgObj.Attributes |
| switch msgObj.EntityClass { |
| case me.AniGClassID: |
| mm.opticalMetricsChan <- meAttributes |
| return nil |
| case me.UniGClassID: |
| mm.uniStatusMetricsChan <- meAttributes |
| return nil |
| case me.PhysicalPathTerminationPointEthernetUniClassID: |
| mm.uniStatusMetricsChan <- meAttributes |
| return nil |
| case me.VirtualEthernetInterfacePointClassID: |
| mm.uniStatusMetricsChan <- meAttributes |
| return nil |
| default: |
| logger.Errorw(ctx, "unhandled omci get response message", |
| log.Fields{"device-id": mm.pDeviceHandler.deviceID, "class-id": msgObj.EntityClass}) |
| } |
| } |
| |
| return errors.New("unhandled-omci-get-response-message") |
| } |
| |
| // flushMetricCollectionChannels flushes all metric collection channels for any stale OMCI responses |
| func (mm *onuMetricsManager) flushMetricCollectionChannels(ctx context.Context) { |
| // flush commMetricsChan |
| select { |
| case <-mm.commMetricsChan: |
| logger.Debug(ctx, "flushed common metrics channel") |
| default: |
| } |
| |
| // flush opticalMetricsChan |
| select { |
| case <-mm.opticalMetricsChan: |
| logger.Debug(ctx, "flushed optical metrics channel") |
| default: |
| } |
| |
| // flush uniStatusMetricsChan |
| select { |
| case <-mm.uniStatusMetricsChan: |
| logger.Debug(ctx, "flushed uni status metrics channel") |
| default: |
| } |
| } |