[VOL-4396] OMCI lib update to be incorporated into ONU adapter, make use of relaxed decoding
Signed-off-by: mpagenko <michael.pagenkopf@adtran.com>
Change-Id: Ic8bc15ae061af8e27d73879f27bb5b80637a8dea
diff --git a/vendor/github.com/opencord/omci-lib-go/v2/generated/xdsllineinventoryandstatusdatapart2.go b/vendor/github.com/opencord/omci-lib-go/v2/generated/xdsllineinventoryandstatusdatapart2.go
new file mode 100644
index 0000000..6385cfd
--- /dev/null
+++ b/vendor/github.com/opencord/omci-lib-go/v2/generated/xdsllineinventoryandstatusdatapart2.go
@@ -0,0 +1,257 @@
+/*
+ * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
+ * Copyright 2020-present Open Networking Foundation
+
+ * Licensed under the Apache License, Version 2.0 (the "License");
+ * you may not use this file except in compliance with the License.
+ * You may obtain a copy of the License at
+
+ * http://www.apache.org/licenses/LICENSE-2.0
+
+ * Unless required by applicable law or agreed to in writing, software
+ * distributed under the License is distributed on an "AS IS" BASIS,
+ * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+ * See the License for the specific language governing permissions and
+ * limitations under the License.
+ */
+/*
+ * NOTE: This file was generated, manual edits will be overwritten!
+ *
+ * Generated by 'goCodeGenerator.py':
+ * https://github.com/cboling/OMCI-parser/README.md
+ */
+
+package generated
+
+import "github.com/deckarep/golang-set"
+
+// XdslLineInventoryAndStatusDataPart2ClassID is the 16-bit ID for the OMCI
+// Managed entity xDSL line inventory and status data part 2
+const XdslLineInventoryAndStatusDataPart2ClassID = ClassID(101) // 0x0065
+
+var xdsllineinventoryandstatusdatapart2BME *ManagedEntityDefinition
+
+// XdslLineInventoryAndStatusDataPart2 (Class ID: #101 / 0x0065)
+// This ME contains part 2 of the line inventory and status data for an xDSL UNI. The ONU
+// automatically creates or deletes an instance of this ME upon the creation or deletion of a PPTP
+// xDSL UNI part 1.
+//
+// NOTE 1 - [ITU-T G.997.1] specifies that bit rate attributes have granularity of 1000-bit/s. If
+// ITUT-G.997.1 compliance is required, the ONU should only report values with this granularity.
+//
+// Relationships
+// An instance of this ME is associated with an xDSL UNI.
+//
+// Attributes
+// Managed Entity Id
+// This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
+// implicitly linked to an instance of the PPTP xDSL UNI part 1. (R) (mandatory) (2-bytes)
+//
+// Xdsl Transmission System
+// This parameter defines the transmission system in use. It is a bit map, defined in Table
+// 9.7.12-1. (R) (mandatory) (7-bytes)
+//
+// NOTE 2 - This attribute is only 7-bytes long. An eighth byte identifying VDSL2 capabilities in
+// use is defined in the VDSL2 line inventory and status data part 1 ME.
+//
+// Line Power Management State
+// The line has four possible power management states.
+//
+// 0 L0: Synchronized - This line state occurs when the line has full transmission (i.e.,
+// showtime).
+//
+// 1 L1: Power down data transmission - This line state occurs when there is transmission on the
+// line, but the net data rate is reduced (e.g., only for OAM and higher layer connection and
+// session control). This state applies to [ITU-T G.992.2] only.
+//
+// 2 L2: Power down data transmission - This line state occurs when there is transmission on the
+// line, but the net data rate is reduced (e.g., only for OAM and higher layer connection and
+// session control). This state applies to [ITU-T G.992.3] and [ITUT-G.992.4] only.
+//
+// 3 L3: No power - This line state occurs when no power is transmitted on the line at all.
+//
+// (R) (mandatory) (1-byte)
+//
+// Downstream Line Attenuation
+// The LATNds attribute is the squared magnitude of the channel characteristics function H(f)
+// averaged over this band, and measured during loop diagnostic mode and initialization. The exact
+// definition is included in the relevant xDSL Recommendation. The attribute value ranges from 0
+// (0.0-dB) to 1270 (127.0-dB) dB. The special value 0xFFFF indicates that line attenuation is out
+// of range. (R) (mandatory) (2-bytes)
+//
+// NOTE 3 - [ITU-T G.993.2] specifies a per-band array to represent this attribute. The array is
+// defined in the VDSL2 line inventory and status data part 3 ME. In an ITU-T G.993.2 context, the
+// downstream line attenuation attribute should be set to 0 here, and populated in the VDSL2 line
+// inventory and status data part 3 ME instead.
+//
+// Upstream Line Attenuation
+// NOTE 4 - [ITU-T G.993.2] specifies a per-band array to represent this attribute. The array is
+// defined in the VDSL2 line inventory and status data part 3 ME. In an ITU-T G.993.2 context, the
+// upstream line attenuation attribute should be set to 0 here, and populated in the VDSL2 line
+// inventory and status data part 3 ME instead.
+//
+// The LATNus attribute is the squared magnitude of the channel characteristics function H(f)
+// averaged over this band, and measured during loop diagnostic mode and initialization. The exact
+// definition is included in the relevant xDSL Recommendation. The attribute value ranges from 0
+// (0.0-dB) to 1270 (127.0-dB). The special value 0xFFFF indicates that line attenuation is out of
+// range. (R) (mandatory) (2-bytes)
+//
+// Downstream Signal Attenuation
+// The SATNds attribute is the measured difference in the total power transmitted in this band by
+// the xTUC and the total power received in this band by the xTUR during loop diagnostic mode,
+// initialization and showtime. The exact definition is included in the relevant xDSL
+// Recommendation. The attribute value ranges from 0 (0.0-dB) to 1270 (127.0-dB). The special value
+// 0xFFFF indicates that signal attenuation is out of range. (R) (mandatory) (2-bytes)
+//
+// NOTE 5 - During showtime, only a subset of the subcarriers may be transmitted by the xTU-C, as
+// compared to loop diagnostic mode and initialization. Therefore, the downstream signal
+// attenuation value during showtime may be significantly lower than the downstream signal
+// attenuation value during loop diagnostic mode and initialization.
+//
+// NOTE 6 - [ITU-T G.993.2] specifies a per-band array to represent this attribute. The array is
+// defined in the VDSL2 line inventory and status data part 3 ME. In an ITU-T G.993.2 context, the
+// downstream signal attenuation attribute should be set to 0 here, and populated in the VDSL2 line
+// inventory and status data part 3 ME instead.
+//
+// Upstream Signal Attenuation
+// The SATNus attribute is the measured difference in decibels in the total power transmitted in
+// this band by the xTUR and the total power received in this band by the xTUC during loop
+// diagnostic mode, initialization and showtime. The exact definition is included in the relevant
+// xDSL Recommendation. The attribute value ranges from 0 (0.0 dB) to 1270 (127.0-dB). The special
+// value 0xFFFF indicates that signal attenuation is out of range. (R) (mandatory) (2-bytes)
+//
+// NOTE 7 - During showtime, only a subset of the subcarriers may be transmitted by the xTU-R, as
+// compared to loop diagnostic mode and initialization. Therefore, the upstream signal attenuation
+// value during showtime may be significantly lower than the upstream signal attenuation value
+// during loop diagnostic mode and initialization.
+//
+// NOTE 8 - [ITU-T G.993.2] specifies a per-band array to represent this attribute. The array is
+// defined in the VDSL2 line inventory and status data part 3 ME. In an ITU-T G.993.2 context, the
+// upstream signal attenuation attribute should be set to 0 here, and populated in the VDSL2 line
+// inventory and status data part 3 ME instead.
+//
+// Downstream Snr Ratio Margin
+// The downstream SNR margin SNRMds is the maximum increase of noise power received at the xTUR,
+// such that the BER requirements can still be met for all downstream bearer channels. The
+// attribute value ranges from 0 (-64.0 dB) to 1270 (+63.0-dB). The special value 0xFFFF indicates
+// that the attribute is out of range (R) (mandatory) (2-bytes)
+//
+// Upstream Snr Margin
+// The upstream SNR margin SNRMus is the maximum increase of noise power received at the xTUC, such
+// that the BER requirements can still be met for all upstream bearer channels. The attribute value
+// ranges from 0 (-64.0 dB) to 1270 (+63.0 dB). The special value 0xFFFF indicates that the
+// attribute is out of range. (R) (mandatory) (2-bytes)
+//
+// Downstream Maximum Attainable Data Rate
+// The ATTNDRds attribute indicates the maximum downstream net data rate currently attainable. The
+// rate is coded in bits per second. (R) (mandatory) (4-bytes)
+//
+// Upstream Maximum Attainable Data Rate
+// The ATTNDRus attribute indicates the maximum upstream net data rate currently attainable. The
+// rate is coded in bits per second. (R) (mandatory) (4-bytes)
+//
+// Downstream Actual Power Spectrum Density
+// The ACTPSDds attribute is the average downstream transmit power spectrum density over the
+// subcarriers in use (subcarriers to which downstream user data are allocated) delivered by the
+// xTUC at the UC reference point, at the instant of measurement. The attribute value ranges from 0
+// (-90.0-dBm/Hz) to 900 (0.0-dBm/Hz). The special value (0xFFFF) indicates that the parameter is
+// out of range. (R) (mandatory) (2-bytes)
+//
+// Upstream Actual Power Spectrum Density
+// The ACTPSDus attribute is the average upstream transmit power spectrum density over the
+// subcarriers in use (subcarriers to which upstream user data are allocated) delivered by the xTUR
+// at the UR reference point, at the instant of measurement. The attribute value ranges from 0
+// (-90.0-dBm/Hz) to 900 (0.0-dBm/Hz). The special value 0xFFFF indicates that the attribute is out
+// of range. (R) (mandatory) (2-bytes)
+//
+// Downstream Actual Aggregate Transmit Power
+// The ACTATPds attribute is the total amount of transmit power delivered by the xTUC at the UC
+// reference point, at the instant of measurement. The attribute value ranges from 0 (-31.0-dBm) to
+// 620 (+31.0-dBm). The special value (0xFFFF) indicates that the parameter is out of range. (R)
+// (mandatory) (2-bytes)
+//
+// NOTE 9 - The downstream nominal aggregate transmit power may be taken as a best estimate of the
+// parameter.
+//
+// Upstream Actual Aggregate Transmit Power
+// NOTE 10 - The upstream nominal aggregate transmit power may be taken as a best estimate of the
+// parameter.
+//
+// The ACTATPus attribute is the total amount of transmit power delivered by the xTUR at the UR
+// reference point, at the instant of measurement. The attribute value ranges from 0 (-31.0-dBm) to
+// 620 (+31.0-dBm). The special value (0xFFFF) indicates that the parameter is out of range. (R)
+// (mandatory) (2-bytes)
+//
+// Initialization _ Last State Transmitted Downstream
+// Initialization - last state transmitted downstream: This attribute represents the last
+// successful transmitted initialization state in the downstream direction in the last full
+// initialization performed on the line. Initialization states are defined in the individual xDSL
+// Recommendations and are counted from 0 (if [ITUT-G.994.1] is used) or 1 (if [ITUT-G.994.1] is
+// not used) up to showtime. This parameter must be interpreted along with the xDSL transmission
+// system capabilities.
+//
+// This parameter is available only when, after a failed full initialization, line diagnostic
+// procedures are activated on the line. Line diagnostic procedures can be activated by the
+// operator of the system (through the loop diagnostics mode forced attribute of the xDSL line
+// configuration profile part 3) or autonomously by the xTU-C or xTU-R.
+//
+// (R) (mandatory) (1-byte)
+//
+// Initialization _ Last State Transmitted Upstream
+// Initialization - last state transmitted upstream: This attribute represents the last successful
+// transmitted initialization state in the upstream direction in the last full initialization
+// performed on the line. Initialization states are defined in the individual xDSL Recommendations
+// and are counted from 0 (if [ITUT-G.994.1] is used) or 1 (if [ITUT-G.994.1] is not used) up to
+// showtime. This parameter must be interpreted along with the xDSL transmission system
+// capabilities.
+//
+// This parameter is available only when, after a failed full initialization, line diagnostic
+// procedures are activated on the line. Line diagnostic procedures can be activated by the
+// operator of the system (through the loop diagnostics mode forced attribute of the xDSL line
+// configuration profile part 3) or autonomously by the xTU-C or xTU-R.
+//
+// (R) (mandatory) (1-byte)
+//
+type XdslLineInventoryAndStatusDataPart2 struct {
+ ManagedEntityDefinition
+ Attributes AttributeValueMap
+}
+
+func init() {
+ xdsllineinventoryandstatusdatapart2BME = &ManagedEntityDefinition{
+ Name: "XdslLineInventoryAndStatusDataPart2",
+ ClassID: 101,
+ MessageTypes: mapset.NewSetWith(
+ Get,
+ ),
+ AllowedAttributeMask: 0xffff,
+ AttributeDefinitions: AttributeDefinitionMap{
+ 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0),
+ 1: MultiByteField("XdslTransmissionSystem", OctetsAttributeType, 0x8000, 7, toOctets("AAAAAAAAAA=="), mapset.NewSetWith(Read), false, false, false, 1),
+ 2: ByteField("LinePowerManagementState", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read), false, false, false, 2),
+ 3: Uint16Field("DownstreamLineAttenuation", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
+ 4: Uint16Field("UpstreamLineAttenuation", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4),
+ 5: Uint16Field("DownstreamSignalAttenuation", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
+ 6: Uint16Field("UpstreamSignalAttenuation", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6),
+ 7: Uint16Field("DownstreamSnrRatioMargin", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7),
+ 8: Uint16Field("UpstreamSnrMargin", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8),
+ 9: Uint32Field("DownstreamMaximumAttainableDataRate", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, false, false, 9),
+ 10: Uint32Field("UpstreamMaximumAttainableDataRate", UnsignedIntegerAttributeType, 0x0040, 0, mapset.NewSetWith(Read), false, false, false, 10),
+ 11: Uint16Field("DownstreamActualPowerSpectrumDensity", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, false, false, 11),
+ 12: Uint16Field("UpstreamActualPowerSpectrumDensity", UnsignedIntegerAttributeType, 0x0010, 0, mapset.NewSetWith(Read), false, false, false, 12),
+ 13: Uint16Field("DownstreamActualAggregateTransmitPower", UnsignedIntegerAttributeType, 0x0008, 0, mapset.NewSetWith(Read), false, false, false, 13),
+ 14: Uint16Field("UpstreamActualAggregateTransmitPower", UnsignedIntegerAttributeType, 0x0004, 0, mapset.NewSetWith(Read), false, false, false, 14),
+ 15: ByteField("InitializationLastStateTransmittedDownstream", UnsignedIntegerAttributeType, 0x0002, 0, mapset.NewSetWith(Read), false, false, false, 15),
+ 16: ByteField("InitializationLastStateTransmittedUpstream", UnsignedIntegerAttributeType, 0x0001, 0, mapset.NewSetWith(Read), false, false, false, 16),
+ },
+ Access: CreatedByOnu,
+ Support: UnknownSupport,
+ }
+}
+
+// NewXdslLineInventoryAndStatusDataPart2 (class ID 101) creates the basic
+// Managed Entity definition that is used to validate an ME of this type that
+// is received from or transmitted to the OMCC.
+func NewXdslLineInventoryAndStatusDataPart2(params ...ParamData) (*ManagedEntity, OmciErrors) {
+ return NewManagedEntity(*xdsllineinventoryandstatusdatapart2BME, params...)
+}