| /* |
| * Copyright 2020-2024 Open Networking Foundation (ONF) and the ONF Contributors |
| * |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| * |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| * |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| |
| // Package uniprt provides the utilities for uni port configuration |
| package uniprt |
| |
| import ( |
| "context" |
| "fmt" |
| "sync" |
| "time" |
| |
| "github.com/looplab/fsm" |
| |
| "github.com/opencord/omci-lib-go/v2" |
| me "github.com/opencord/omci-lib-go/v2/generated" |
| "github.com/opencord/voltha-lib-go/v7/pkg/log" |
| cmn "github.com/opencord/voltha-openonu-adapter-go/internal/pkg/common" |
| ) |
| |
| // LockStateFsm defines the structure for the state machine to lock/unlock the ONU UNI ports via OMCI |
| type LockStateFsm struct { |
| deviceID string |
| pDeviceHandler cmn.IdeviceHandler |
| pOnuDeviceEntry cmn.IonuDeviceEntry |
| pOmciCC *cmn.OmciCC |
| mutexAdminState sync.RWMutex |
| adminState bool |
| requestEvent cmn.OnuDeviceEvent |
| omciLockResponseReceived chan bool //seperate channel needed for checking UNI port OMCi message responses |
| PAdaptFsm *cmn.AdapterFsm |
| mutexPLastTxMeInstance sync.RWMutex |
| pLastTxMeInstance *me.ManagedEntity |
| } |
| |
| // events of lock/unlock UNI port FSM |
| const ( |
| UniEvStart = "UniEvStart" |
| UniEvStartAdmin = "UniEvStartAdmin" |
| UniEvRxUnisResp = "UniEvRxUnisResp" |
| UniEvRxOnugResp = "UniEvRxOnugResp" |
| UniEvTimeoutSimple = "UniEvTimeoutSimple" |
| UniEvTimeoutUnis = "UniEvTimeoutUnis" |
| UniEvReset = "UniEvReset" |
| UniEvRestart = "UniEvRestart" |
| ) |
| |
| // states of lock/unlock UNI port FSM |
| const ( |
| UniStDisabled = "UniStDisabled" |
| UniStStarting = "UniStStarting" |
| UniStSettingUnis = "UniStSettingUnis" |
| UniStSettingOnuG = "UniStSettingOnuG" |
| UniStAdminDone = "UniStAdminDone" |
| UniStResetting = "UniStResetting" |
| ) |
| |
| // CUniFsmIdleState - TODO: add comment |
| const CUniFsmIdleState = UniStDisabled |
| |
| // NewLockStateFsm is the 'constructor' for the state machine to lock/unlock the ONU UNI ports via OMCI |
| func NewLockStateFsm(ctx context.Context, aAdminState bool, aRequestEvent cmn.OnuDeviceEvent, |
| aName string, apDeviceHandler cmn.IdeviceHandler, apOnuDeviceEntry cmn.IonuDeviceEntry, aCommChannel chan cmn.Message) *LockStateFsm { |
| instFsm := &LockStateFsm{ |
| deviceID: apDeviceHandler.GetDeviceID(), |
| pDeviceHandler: apDeviceHandler, |
| pOnuDeviceEntry: apOnuDeviceEntry, |
| pOmciCC: apOnuDeviceEntry.GetDevOmciCC(), |
| adminState: aAdminState, |
| requestEvent: aRequestEvent, |
| } |
| instFsm.PAdaptFsm = cmn.NewAdapterFsm(aName, instFsm.deviceID, aCommChannel) |
| if instFsm.PAdaptFsm == nil { |
| logger.Errorw(ctx, "LockStateFsm's cmn.AdapterFsm could not be instantiated!!", log.Fields{ |
| "device-id": instFsm.deviceID}) |
| return nil |
| } |
| if aAdminState { //port locking requested |
| instFsm.PAdaptFsm.PFsm = fsm.NewFSM( |
| UniStDisabled, |
| fsm.Events{ |
| |
| {Name: UniEvStart, Src: []string{UniStDisabled}, Dst: UniStStarting}, |
| |
| {Name: UniEvStartAdmin, Src: []string{UniStStarting}, Dst: UniStSettingUnis}, |
| // the settingUnis state is used for multi ME config for all UNI related ports |
| // maybe such could be reflected in the state machine as well (port number parametrized) |
| // but that looks not straightforward here - so we keep it simple here for the beginning(?) |
| {Name: UniEvRxUnisResp, Src: []string{UniStSettingUnis}, Dst: UniStSettingOnuG}, |
| {Name: UniEvRxOnugResp, Src: []string{UniStSettingOnuG}, Dst: UniStAdminDone}, |
| |
| {Name: UniEvTimeoutSimple, Src: []string{UniStSettingOnuG}, Dst: UniStStarting}, |
| {Name: UniEvTimeoutUnis, Src: []string{UniStSettingUnis}, Dst: UniStStarting}, |
| |
| {Name: UniEvReset, Src: []string{UniStStarting, UniStSettingOnuG, UniStSettingUnis, |
| UniStAdminDone}, Dst: UniStResetting}, |
| // exceptional treatment for all states except UniStResetting |
| {Name: UniEvRestart, Src: []string{UniStStarting, UniStSettingOnuG, UniStSettingUnis, |
| UniStAdminDone, UniStResetting}, Dst: UniStDisabled}, |
| }, |
| |
| fsm.Callbacks{ |
| "enter_state": func(e *fsm.Event) { instFsm.PAdaptFsm.LogFsmStateChange(ctx, e) }, |
| ("enter_" + UniStStarting): func(e *fsm.Event) { instFsm.enterAdminStartingState(ctx, e) }, |
| ("enter_" + UniStSettingOnuG): func(e *fsm.Event) { instFsm.enterSettingOnuGState(ctx, e) }, |
| ("enter_" + UniStSettingUnis): func(e *fsm.Event) { instFsm.enterSettingUnisState(ctx, e) }, |
| ("enter_" + UniStAdminDone): func(e *fsm.Event) { instFsm.enterAdminDoneState(ctx, e) }, |
| ("enter_" + UniStResetting): func(e *fsm.Event) { instFsm.enterResettingState(ctx, e) }, |
| }, |
| ) |
| } else { //port unlocking requested |
| instFsm.PAdaptFsm.PFsm = fsm.NewFSM( |
| UniStDisabled, |
| fsm.Events{ |
| |
| {Name: UniEvStart, Src: []string{UniStDisabled}, Dst: UniStStarting}, |
| |
| {Name: UniEvStartAdmin, Src: []string{UniStStarting}, Dst: UniStSettingOnuG}, |
| {Name: UniEvRxOnugResp, Src: []string{UniStSettingOnuG}, Dst: UniStSettingUnis}, |
| // the settingUnis state is used for multi ME config for all UNI related ports |
| // maybe such could be reflected in the state machine as well (port number parametrized) |
| // but that looks not straightforward here - so we keep it simple here for the beginning(?) |
| {Name: UniEvRxUnisResp, Src: []string{UniStSettingUnis}, Dst: UniStAdminDone}, |
| |
| {Name: UniEvTimeoutSimple, Src: []string{UniStSettingOnuG}, Dst: UniStStarting}, |
| {Name: UniEvTimeoutUnis, Src: []string{UniStSettingUnis}, Dst: UniStStarting}, |
| |
| {Name: UniEvReset, Src: []string{UniStStarting, UniStSettingOnuG, UniStSettingUnis, |
| UniStAdminDone}, Dst: UniStResetting}, |
| // exceptional treatment for all states except UniStResetting |
| {Name: UniEvRestart, Src: []string{UniStStarting, UniStSettingOnuG, UniStSettingUnis, |
| UniStAdminDone, UniStResetting}, Dst: UniStDisabled}, |
| }, |
| |
| fsm.Callbacks{ |
| "enter_state": func(e *fsm.Event) { instFsm.PAdaptFsm.LogFsmStateChange(ctx, e) }, |
| ("enter_" + UniStStarting): func(e *fsm.Event) { instFsm.enterAdminStartingState(ctx, e) }, |
| ("enter_" + UniStSettingOnuG): func(e *fsm.Event) { instFsm.enterSettingOnuGState(ctx, e) }, |
| ("enter_" + UniStSettingUnis): func(e *fsm.Event) { instFsm.enterSettingUnisState(ctx, e) }, |
| ("enter_" + UniStAdminDone): func(e *fsm.Event) { instFsm.enterAdminDoneState(ctx, e) }, |
| ("enter_" + UniStResetting): func(e *fsm.Event) { instFsm.enterResettingState(ctx, e) }, |
| }, |
| ) |
| } |
| if instFsm.PAdaptFsm.PFsm == nil { |
| logger.Errorw(ctx, "LockStateFsm's Base FSM could not be instantiated!!", log.Fields{ |
| "device-id": instFsm.deviceID}) |
| return nil |
| } |
| |
| logger.Debugw(ctx, "LockStateFsm created", log.Fields{"device-id": instFsm.deviceID}) |
| return instFsm |
| } |
| |
| // SetSuccessEvent modifies the requested event notified on success |
| // assumption is that this is only called in the disabled (idle) state of the FSM, hence no sem protection required |
| func (oFsm *LockStateFsm) SetSuccessEvent(aEvent cmn.OnuDeviceEvent) { |
| oFsm.requestEvent = aEvent |
| } |
| |
| func (oFsm *LockStateFsm) enterAdminStartingState(ctx context.Context, e *fsm.Event) { |
| logger.Debugw(ctx, "LockStateFSM start", log.Fields{"in state": e.FSM.Current(), |
| "device-id": oFsm.deviceID}) |
| // in case the used channel is not yet defined (can be re-used after restarts) |
| if oFsm.omciLockResponseReceived == nil { |
| oFsm.omciLockResponseReceived = make(chan bool) |
| logger.Debug(ctx, "LockStateFSM - OMCI UniLock RxChannel defined") |
| } else { |
| // as we may 're-use' this instance of FSM and the connected channel |
| // make sure there is no 'lingering' request in the already existing channels: |
| // (simple loop sufficient as we are the only receiver) |
| for len(oFsm.omciLockResponseReceived) > 0 { |
| <-oFsm.omciLockResponseReceived |
| } |
| for len(oFsm.PAdaptFsm.CommChan) > 0 { |
| <-oFsm.PAdaptFsm.CommChan |
| } |
| } |
| // start go routine for processing of LockState messages |
| go oFsm.processOmciLockMessages(ctx) |
| |
| //let the state machine run forward from here directly |
| pLockStateAFsm := oFsm.PAdaptFsm |
| if pLockStateAFsm != nil { |
| // obviously calling some FSM event here directly does not work - so trying to decouple it ... |
| go func(a_pAFsm *cmn.AdapterFsm) { |
| if a_pAFsm != nil && a_pAFsm.PFsm != nil { |
| _ = a_pAFsm.PFsm.Event(UniEvStartAdmin) |
| } |
| }(pLockStateAFsm) |
| } |
| } |
| |
| func (oFsm *LockStateFsm) enterSettingOnuGState(ctx context.Context, e *fsm.Event) { |
| var omciAdminState uint8 = 1 //default locked |
| oFsm.mutexAdminState.RLock() |
| if !oFsm.adminState { |
| omciAdminState = 0 |
| } |
| oFsm.mutexAdminState.RUnlock() |
| logger.Debugw(ctx, "LockStateFSM Tx Set::ONU-G:admin", log.Fields{ |
| "omciAdmin": omciAdminState, "in state": e.FSM.Current(), "device-id": oFsm.deviceID}) |
| requestedAttributes := me.AttributeValueMap{me.OnuG_AdministrativeState: omciAdminState} |
| oFsm.mutexPLastTxMeInstance.Lock() |
| meInstance, err := oFsm.pOmciCC.SendSetOnuGLS(log.WithSpanFromContext(context.TODO(), ctx), oFsm.pDeviceHandler.GetOmciTimeout(), true, |
| requestedAttributes, oFsm.PAdaptFsm.CommChan) |
| if err != nil { |
| //Indicate the failure in UnLock case |
| if omciAdminState == 0 { |
| oFsm.SetSuccessEvent(cmn.UniEnableStateFailed) |
| } |
| oFsm.mutexPLastTxMeInstance.Unlock() |
| logger.Errorw(ctx, "OnuGLS set failed, aborting LockStateFSM", log.Fields{"device-id": oFsm.deviceID}) |
| pLockStateAFsm := oFsm.PAdaptFsm |
| if pLockStateAFsm != nil { |
| go func(a_pAFsm *cmn.AdapterFsm) { |
| if a_pAFsm != nil && a_pAFsm.PFsm != nil { |
| _ = a_pAFsm.PFsm.Event(UniEvReset) |
| } |
| }(pLockStateAFsm) |
| } |
| return |
| } |
| //accept also nil as (error) return value for writing to LastTx |
| // - this avoids misinterpretation of new received OMCI messages |
| oFsm.pLastTxMeInstance = meInstance |
| if oFsm.pLastTxMeInstance == nil { |
| //Indicate the failure in UnLock case |
| if omciAdminState == 0 { |
| oFsm.SetSuccessEvent(cmn.UniEnableStateFailed) |
| } |
| oFsm.mutexPLastTxMeInstance.Unlock() |
| logger.Errorw(ctx, "could not send OMCI message from LockStateFsm", log.Fields{ |
| "device-id": oFsm.deviceID}) |
| //some more sophisticated approach is possible, e.g. repeating once, by now let's reset the state machine in order to release all resources now |
| pLockStateAFsm := oFsm.PAdaptFsm |
| if pLockStateAFsm != nil { |
| |
| // obviously calling some FSM event here directly does not work - so trying to decouple it ... |
| go func(a_pAFsm *cmn.AdapterFsm) { |
| if a_pAFsm != nil && a_pAFsm.PFsm != nil { |
| _ = a_pAFsm.PFsm.Event(UniEvReset) |
| } |
| }(pLockStateAFsm) |
| } |
| return |
| } |
| oFsm.mutexPLastTxMeInstance.Unlock() |
| } |
| |
| func (oFsm *LockStateFsm) enterSettingUnisState(ctx context.Context, e *fsm.Event) { |
| oFsm.mutexAdminState.RLock() |
| logger.Debugw(ctx, "LockStateFSM - starting UniTP adminState loop", log.Fields{ |
| "in state": e.FSM.Current(), "device-id": oFsm.deviceID, "LockState": oFsm.adminState}) |
| oFsm.mutexAdminState.RUnlock() |
| go oFsm.performUniPortAdminSet(ctx) |
| } |
| |
| func (oFsm *LockStateFsm) enterAdminDoneState(ctx context.Context, e *fsm.Event) { |
| logger.Debugw(ctx, "LockStateFSM", log.Fields{"send notification to core in State": e.FSM.Current(), "device-id": oFsm.deviceID}) |
| //use DeviceHandler event notification directly, no need/support to update DeviceEntryState for lock/unlock |
| oFsm.pDeviceHandler.DeviceProcStatusUpdate(ctx, oFsm.requestEvent) |
| |
| //let's reset the state machine in order to release all resources now |
| pLockStateAFsm := oFsm.PAdaptFsm |
| if pLockStateAFsm != nil { |
| // obviously calling some FSM event here directly does not work - so trying to decouple it ... |
| go func(a_pAFsm *cmn.AdapterFsm) { |
| if a_pAFsm != nil && a_pAFsm.PFsm != nil { |
| _ = a_pAFsm.PFsm.Event(UniEvReset) |
| } |
| }(pLockStateAFsm) |
| } |
| } |
| |
| func (oFsm *LockStateFsm) enterResettingState(ctx context.Context, e *fsm.Event) { |
| logger.Debugw(ctx, "LockStateFSM resetting", log.Fields{"device-id": oFsm.deviceID}) |
| //If the fsm is reseted because of a failure during reenable, then issue the fail event. |
| if oFsm.requestEvent == cmn.UniEnableStateFailed { |
| logger.Debugw(ctx, "LockStateFSM send notification to core", log.Fields{"state": e.FSM.Current(), "device-id": oFsm.deviceID}) |
| //use DeviceHandler event notification directly, no need/support to update DeviceEntryState for lock/unlock |
| oFsm.pDeviceHandler.DeviceProcStatusUpdate(ctx, oFsm.requestEvent) |
| } |
| |
| pLockStateAFsm := oFsm.PAdaptFsm |
| if pLockStateAFsm != nil { |
| // abort running message processing |
| fsmAbortMsg := cmn.Message{ |
| Type: cmn.TestMsg, |
| Data: cmn.TestMessage{ |
| TestMessageVal: cmn.AbortMessageProcessing, |
| }, |
| } |
| pLockStateAFsm.CommChan <- fsmAbortMsg |
| |
| //try to restart the FSM to 'disabled' |
| // see DownloadedState: decouple event transfer |
| go func(a_pAFsm *cmn.AdapterFsm) { |
| if a_pAFsm != nil && a_pAFsm.PFsm != nil { |
| _ = a_pAFsm.PFsm.Event(UniEvRestart) |
| } |
| }(pLockStateAFsm) |
| oFsm.mutexPLastTxMeInstance.Lock() |
| oFsm.pLastTxMeInstance = nil |
| oFsm.mutexPLastTxMeInstance.Unlock() |
| } |
| } |
| |
| func (oFsm *LockStateFsm) processOmciLockMessages(ctx context.Context) { |
| logger.Debugw(ctx, "Start LockStateFsm Msg processing", log.Fields{"for device-id": oFsm.deviceID}) |
| loop: |
| for { |
| // case <-ctx.Done(): |
| // logger.Info(ctx,"MibSync Msg", log.Fields{"Message handling canceled via context for device-id": oFsm.deviceID}) |
| // break loop |
| message, ok := <-oFsm.PAdaptFsm.CommChan |
| if !ok { |
| logger.Info(ctx, "LockStateFsm Rx Msg - could not read from channel", log.Fields{"device-id": oFsm.deviceID}) |
| // but then we have to ensure a restart of the FSM as well - as exceptional procedure |
| _ = oFsm.PAdaptFsm.PFsm.Event(UniEvRestart) |
| break loop |
| } |
| logger.Debugw(ctx, "LockStateFsm Rx Msg", log.Fields{"device-id": oFsm.deviceID}) |
| |
| switch message.Type { |
| case cmn.TestMsg: |
| msg, _ := message.Data.(cmn.TestMessage) |
| if msg.TestMessageVal == cmn.AbortMessageProcessing { |
| logger.Debugw(ctx, "LockStateFsm abort ProcessMsg", log.Fields{"for device-id": oFsm.deviceID}) |
| break loop |
| } |
| logger.Warnw(ctx, "LockStateFsm unknown TestMessage", log.Fields{"device-id": oFsm.deviceID, "MessageVal": msg.TestMessageVal}) |
| case cmn.OMCI: |
| msg, _ := message.Data.(cmn.OmciMessage) |
| oFsm.handleOmciLockStateMessage(ctx, msg) |
| default: |
| logger.Warn(ctx, "LockStateFsm Rx unknown message", log.Fields{"device-id": oFsm.deviceID, |
| "message.Type": message.Type}) |
| } |
| } |
| logger.Debugw(ctx, "End LockStateFsm Msg processing", log.Fields{"device-id": oFsm.deviceID}) |
| } |
| |
| func (oFsm *LockStateFsm) handleOmciLockStateMessage(ctx context.Context, msg cmn.OmciMessage) { |
| logger.Debugw(ctx, "Rx OMCI LockStateFsm Msg", log.Fields{"device-id": oFsm.deviceID, |
| "msgType": msg.OmciMsg.MessageType}) |
| |
| if msg.OmciMsg.MessageType == omci.SetResponseType { |
| msgLayer := (*msg.OmciPacket).Layer(omci.LayerTypeSetResponse) |
| if msgLayer == nil { |
| logger.Errorw(ctx, "LockStateFsm - Omci Msg layer could not be detected for SetResponse", |
| log.Fields{"device-id": oFsm.deviceID}) |
| return |
| } |
| msgObj, msgOk := msgLayer.(*omci.SetResponse) |
| if !msgOk { |
| logger.Errorw(ctx, "LockStateFsm - Omci Msg layer could not be assigned for SetResponse", |
| log.Fields{"device-id": oFsm.deviceID}) |
| return |
| } |
| logger.Debugw(ctx, "LockStateFsm SetResponse Data", log.Fields{"device-id": oFsm.deviceID, "data-fields": msgObj}) |
| if msgObj.Result != me.Success { |
| logger.Errorw(ctx, "LockStateFsm - Omci SetResponse Error - later: drive FSM to abort state ?", |
| log.Fields{"Error": msgObj.Result, "EntityClass": msgObj.EntityClass, "EntityInstance": msgObj.EntityInstance, "device-id": oFsm.deviceID}) |
| // possibly force FSM into abort or ignore some errors for some messages? store error for mgmt display? |
| return |
| } |
| |
| //should never appear, left here for robustness |
| oFsm.mutexPLastTxMeInstance.RLock() |
| if oFsm.pLastTxMeInstance != nil { |
| // compare comments above for CreateResponse (apply also here ...) |
| if msgObj.EntityClass == oFsm.pLastTxMeInstance.GetClassID() && |
| msgObj.EntityInstance == oFsm.pLastTxMeInstance.GetEntityID() { |
| //store the created ME into DB //TODO??? obviously the Python code does not store the config ... |
| // if, then something like: |
| //oFsm.pOnuDB.StoreMe(msgObj) |
| |
| switch oFsm.pLastTxMeInstance.GetName() { |
| case "OnuG": |
| { // let the FSM proceed ... |
| oFsm.mutexPLastTxMeInstance.RUnlock() |
| _ = oFsm.PAdaptFsm.PFsm.Event(UniEvRxOnugResp) |
| } |
| case "PhysicalPathTerminationPointEthernetUni", "VirtualEthernetInterfacePoint": |
| { // let the PPTP init proceed by stopping the wait function |
| oFsm.mutexPLastTxMeInstance.RUnlock() |
| oFsm.omciLockResponseReceived <- true |
| } |
| default: |
| { |
| logger.Warnw(ctx, "Unsupported ME name received!", |
| log.Fields{"ME name": oFsm.pLastTxMeInstance.GetName(), "device-id": oFsm.deviceID}) |
| oFsm.mutexPLastTxMeInstance.RUnlock() |
| } |
| } |
| } else { |
| oFsm.mutexPLastTxMeInstance.RUnlock() |
| logger.Warnf(ctx, "LockStateFsm - Received SetResponse Data for %s with wrong classID or entityID ", |
| log.Fields{"device-id": oFsm.deviceID, "data-fields": msgObj}, msgObj.EntityClass) |
| } |
| } else { |
| oFsm.mutexPLastTxMeInstance.RUnlock() |
| logger.Errorw(ctx, "pLastTxMeInstance is nil", log.Fields{"device-id": oFsm.deviceID}) |
| return |
| } |
| } else { |
| logger.Errorw(ctx, "LockStateFsm - Rx OMCI unhandled MsgType", log.Fields{"device-id": oFsm.deviceID, "omciMsgType": msg.OmciMsg.MessageType}) |
| return |
| } |
| } |
| |
| func (oFsm *LockStateFsm) performUniPortAdminSet(ctx context.Context) { |
| var omciAdminState uint8 = 1 //default locked |
| oFsm.mutexAdminState.RLock() |
| if !oFsm.adminState { |
| omciAdminState = 0 |
| } |
| oFsm.mutexAdminState.RUnlock() |
| //set PPTPEthUni or VEIP AdminState |
| requestedAttributes := me.AttributeValueMap{me.PhysicalPathTerminationPointEthernetUni_AdministrativeState: omciAdminState} |
| |
| for uniNo, uniPort := range *oFsm.pDeviceHandler.GetUniEntityMap() { |
| // only unlock the UniPort in case it is defined for usage (R2.6 limit only one port), |
| // compare also limitation for logical voltha port in dh.EnableUniPortStateUpdate() |
| |
| if (omciAdminState == 1) || (1<<uniPort.UniID)&oFsm.pDeviceHandler.GetUniPortMask() == (1<<uniPort.UniID) { |
| var meInstance *me.ManagedEntity |
| if uniPort.PortType == cmn.UniPPTP { |
| logger.Debugw(ctx, "Setting PPTP admin state", log.Fields{ |
| "device-id": oFsm.deviceID, "for PortNo": uniNo, "state (0-unlock)": omciAdminState}) |
| oFsm.mutexPLastTxMeInstance.Lock() |
| meInstance, err := oFsm.pOmciCC.SendSetPptpEthUniLS(log.WithSpanFromContext(context.TODO(), ctx), |
| uniPort.EntityID, oFsm.pDeviceHandler.GetOmciTimeout(), |
| true, requestedAttributes, oFsm.PAdaptFsm.CommChan) |
| if err != nil { |
| oFsm.mutexPLastTxMeInstance.Unlock() |
| logger.Errorw(ctx, "SetPptpEthUniLS set failed, aborting LockStateFsm!", |
| log.Fields{"device-id": oFsm.deviceID}) |
| //Indicate the failure in UnLock case |
| if omciAdminState == 0 { |
| oFsm.SetSuccessEvent(cmn.UniEnableStateFailed) |
| } |
| _ = oFsm.PAdaptFsm.PFsm.Event(UniEvReset) |
| return |
| } |
| oFsm.pLastTxMeInstance = meInstance |
| oFsm.mutexPLastTxMeInstance.Unlock() |
| } else if uniPort.PortType == cmn.UniVEIP { |
| logger.Debugw(ctx, "Setting VEIP admin state", log.Fields{ |
| "device-id": oFsm.deviceID, "for PortNo": uniNo, "state (0-unlock)": omciAdminState}) |
| oFsm.mutexPLastTxMeInstance.Lock() |
| meInstance, err := oFsm.pOmciCC.SendSetVeipLS(log.WithSpanFromContext(context.TODO(), ctx), |
| uniPort.EntityID, oFsm.pDeviceHandler.GetOmciTimeout(), |
| true, requestedAttributes, oFsm.PAdaptFsm.CommChan) |
| if err != nil { |
| oFsm.mutexPLastTxMeInstance.Unlock() |
| logger.Errorw(ctx, "SetVeipLS set failed, aborting LockStateFsm!", |
| log.Fields{"device-id": oFsm.deviceID}) |
| //Indicate the failure in UnLock case |
| if omciAdminState == 0 { |
| oFsm.SetSuccessEvent(cmn.UniEnableStateFailed) |
| } |
| _ = oFsm.PAdaptFsm.PFsm.Event(UniEvReset) |
| return |
| } |
| oFsm.pLastTxMeInstance = meInstance |
| oFsm.mutexPLastTxMeInstance.Unlock() |
| } else { |
| //TODO: Discuss on the uni port type POTS . |
| logger.Warnw(ctx, "Unsupported UniTP type - skip", |
| log.Fields{"device-id": oFsm.deviceID, "Port": uniNo}) |
| continue |
| } |
| oFsm.mutexPLastTxMeInstance.RLock() |
| if oFsm.pLastTxMeInstance == nil { |
| oFsm.mutexPLastTxMeInstance.RUnlock() |
| logger.Errorw(ctx, "could not send PortAdmin OMCI message from LockStateFsm", log.Fields{ |
| "device-id": oFsm.deviceID, "Port": uniNo}) |
| //Indicate the failure in UnLock case |
| if omciAdminState == 0 { |
| oFsm.SetSuccessEvent(cmn.UniEnableStateFailed) |
| } |
| //some more sophisticated approach is possible, e.g. repeating once, by now let's reset the state machine in order to release all resources now |
| _ = oFsm.PAdaptFsm.PFsm.Event(UniEvReset) |
| return |
| } |
| oFsm.mutexPLastTxMeInstance.RUnlock() |
| |
| //verify response |
| err := oFsm.waitforOmciResponse(ctx, meInstance) |
| if err != nil { |
| logger.Errorw(ctx, "UniTP Admin State set failed, aborting LockState set!", |
| log.Fields{"device-id": oFsm.deviceID, "Port": uniNo}) |
| //Indicate the failure in UnLock case |
| if omciAdminState == 0 { |
| oFsm.SetSuccessEvent(cmn.UniEnableStateFailed) |
| } |
| _ = oFsm.PAdaptFsm.PFsm.Event(UniEvReset) |
| return |
| } |
| } |
| } //for all UNI ports |
| // if Config has been done for all UNI related instances let the FSM proceed |
| // while we did not check here, if there is some port at all - !? |
| logger.Infow(ctx, "UniTP adminState loop finished", log.Fields{"device-id": oFsm.deviceID}) |
| _ = oFsm.PAdaptFsm.PFsm.Event(UniEvRxUnisResp) |
| } |
| |
| func (oFsm *LockStateFsm) waitforOmciResponse(ctx context.Context, apMeInstance *me.ManagedEntity) error { |
| select { |
| // maybe be also some outside cancel (but no context modeled for the moment ...) |
| // case <-ctx.Done(): |
| // logger.Infow(ctx,"LockState-bridge-init message reception canceled", log.Fields{"for device-id": oFsm.deviceID}) |
| case <-time.After(oFsm.pOmciCC.GetMaxOmciTimeoutWithRetries() * time.Second): //3s was detected to be to less in 8*8 bbsim test with debug Info/Debug |
| logger.Warnw(ctx, "lockStateFSM uni-set timeout", log.Fields{"for device-id": oFsm.deviceID}) |
| return fmt.Errorf("lockStateFsm uni-set timeout for device-id %s", oFsm.deviceID) |
| case success := <-oFsm.omciLockResponseReceived: |
| if success { |
| logger.Debug(ctx, "LockStateFSM uni-set response received") |
| return nil |
| } |
| // should not happen so far |
| logger.Warnw(ctx, "lockStateFSM uni-set response error", log.Fields{"for device-id": oFsm.deviceID}) |
| return fmt.Errorf("lockStateFsm uni-set responseError for device-id %s", oFsm.deviceID) |
| } |
| } |
| |
| // PrepareForGarbageCollection - remove references to prepare for garbage collection |
| func (oFsm *LockStateFsm) PrepareForGarbageCollection(ctx context.Context, aDeviceID string) { |
| logger.Debugw(ctx, "prepare for garbage collection", log.Fields{"device-id": aDeviceID}) |
| oFsm.pDeviceHandler = nil |
| oFsm.pOnuDeviceEntry = nil |
| oFsm.pOmciCC = nil |
| } |