blob: ac6bbf8049276b0ab2d21089b585eaef5311e850 [file] [log] [blame]
Holger Hildebrandtfa074992020-03-27 15:42:06 +00001/*
2 * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
3 * Copyright 2020-present Open Networking Foundation
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +00004 *
Holger Hildebrandtfa074992020-03-27 15:42:06 +00005 * Licensed under the Apache License, Version 2.0 (the "License");
6 * you may not use this file except in compliance with the License.
7 * You may obtain a copy of the License at
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +00008 *
Holger Hildebrandtfa074992020-03-27 15:42:06 +00009 * http://www.apache.org/licenses/LICENSE-2.0
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +000010 *
Holger Hildebrandtfa074992020-03-27 15:42:06 +000011 * Unless required by applicable law or agreed to in writing, software
12 * distributed under the License is distributed on an "AS IS" BASIS,
13 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
14 * See the License for the specific language governing permissions and
15 * limitations under the License.
16 */
Himani Chawlaac1f5ad2021-02-04 21:21:54 +053017/*
Holger Hildebrandtfa074992020-03-27 15:42:06 +000018 * NOTE: This file was generated, manual edits will be overwritten!
19 *
20 * Generated by 'goCodeGenerator.py':
21 * https://github.com/cboling/OMCI-parser/README.md
22 */
23
24package generated
25
26import "github.com/deckarep/golang-set"
27
28// CallControlPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
29// Managed entity Call control performance monitoring history data
mpagenko836a1fd2021-11-01 16:12:42 +000030const CallControlPerformanceMonitoringHistoryDataClassID = ClassID(140) // 0x008c
Holger Hildebrandtfa074992020-03-27 15:42:06 +000031
32var callcontrolperformancemonitoringhistorydataBME *ManagedEntityDefinition
33
mpagenko836a1fd2021-11-01 16:12:42 +000034// CallControlPerformanceMonitoringHistoryData (Class ID: #140 / 0x008c)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000035// This ME collects PM data related to the call control channel. Instances of this ME are created
36// and deleted by the OLT.
37//
38// For a complete discussion of generic PM architecture, refer to clause I.4.
39//
40// Relationships
41// An instance of this ME is associated with an instance of the PPTP POTS UNI ME.
42//
43// Attributes
44// Managed Entity Id
mpagenko836a1fd2021-11-01 16:12:42 +000045// This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
46// implicitly linked to an instance of the PPTP POTS UNI. (R, setbycreate) (mandatory) (2-bytes)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000047//
48// Interval End Time
mpagenko836a1fd2021-11-01 16:12:42 +000049// This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1-byte)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000050//
51// Threshold Data 1_2 Id
52// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that
53// contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold
54// data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes)
55//
56// Call Setup Failures
mpagenko836a1fd2021-11-01 16:12:42 +000057// This attribute counts call set-up failures. (R) (mandatory) (4-bytes)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000058//
59// Call Setup Timer
mpagenko836a1fd2021-11-01 16:12:42 +000060// This attribute is a high water-mark that records the longest duration of a single call set-up
61// detected during this interval. Time is measured in milliseconds from the time an initial set-up
62// was requested by the subscriber until the time at which a response was provided to the
63// subscriber in the form of busy tone, audible ring tone, etc. (R) (mandatory) (4-bytes)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000064//
65// Call Terminate Failures
mpagenko836a1fd2021-11-01 16:12:42 +000066// This attribute counts the number of calls that were terminated with cause. (R) (mandatory)
67// (4-bytes)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000068//
69// Analog Port Releases
mpagenko836a1fd2021-11-01 16:12:42 +000070// This attribute counts the number of analogue port releases without dialling detected (abandoned
71// calls). (R) (mandatory) (4-bytes)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000072//
73// Analog Port Off_Hook Timer
74// Analog port off-hook timer: This attribute is a high water-mark that records the longest period
75// of a single off-hook detected on the analogue port. Time is measured in milliseconds. (R)
76// (mandatory) (4-bytes)
77//
78type CallControlPerformanceMonitoringHistoryData struct {
79 ManagedEntityDefinition
80 Attributes AttributeValueMap
81}
82
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +000083// Attribute name constants
84
85const CallControlPerformanceMonitoringHistoryData_IntervalEndTime = "IntervalEndTime"
86const CallControlPerformanceMonitoringHistoryData_ThresholdData12Id = "ThresholdData12Id"
87const CallControlPerformanceMonitoringHistoryData_CallSetupFailures = "CallSetupFailures"
88const CallControlPerformanceMonitoringHistoryData_CallSetupTimer = "CallSetupTimer"
89const CallControlPerformanceMonitoringHistoryData_CallTerminateFailures = "CallTerminateFailures"
90const CallControlPerformanceMonitoringHistoryData_AnalogPortReleases = "AnalogPortReleases"
91const CallControlPerformanceMonitoringHistoryData_AnalogPortOffHookTimer = "AnalogPortOffHookTimer"
92
Holger Hildebrandtfa074992020-03-27 15:42:06 +000093func init() {
94 callcontrolperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
95 Name: "CallControlPerformanceMonitoringHistoryData",
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +000096 ClassID: CallControlPerformanceMonitoringHistoryDataClassID,
Holger Hildebrandtfa074992020-03-27 15:42:06 +000097 MessageTypes: mapset.NewSetWith(
98 Create,
99 Delete,
100 Get,
101 Set,
Girish Gowdra5c5aaf42021-02-17 19:40:50 -0800102 GetCurrentData,
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000103 ),
104 AllowedAttributeMask: 0xfe00,
105 AttributeDefinitions: AttributeDefinitionMap{
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +0000106 0: Uint16Field(ManagedEntityID, PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
107 1: ByteField(CallControlPerformanceMonitoringHistoryData_IntervalEndTime, UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
108 2: Uint16Field(CallControlPerformanceMonitoringHistoryData_ThresholdData12Id, UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
109 3: Uint32Field(CallControlPerformanceMonitoringHistoryData_CallSetupFailures, CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
110 4: Uint32Field(CallControlPerformanceMonitoringHistoryData_CallSetupTimer, CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4),
111 5: Uint32Field(CallControlPerformanceMonitoringHistoryData_CallTerminateFailures, CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
112 6: Uint32Field(CallControlPerformanceMonitoringHistoryData_AnalogPortReleases, CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6),
113 7: Uint32Field(CallControlPerformanceMonitoringHistoryData_AnalogPortOffHookTimer, CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7),
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000114 },
115 Access: CreatedByOlt,
116 Support: UnknownSupport,
Himani Chawlaac1f5ad2021-02-04 21:21:54 +0530117 Alarms: AlarmMap{
118 0: "CCPM call set-up fail",
119 1: "CCPM set-up timeout",
120 2: "CCPM call terminate",
121 3: "CCPM port release with no dialling",
122 4: "CCPM port offhook timeout",
123 },
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000124 }
125}
126
127// NewCallControlPerformanceMonitoringHistoryData (class ID 140) creates the basic
128// Managed Entity definition that is used to validate an ME of this type that
129// is received from or transmitted to the OMCC.
130func NewCallControlPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {
131 return NewManagedEntity(*callcontrolperformancemonitoringhistorydataBME, params...)
132}