blob: e6f1d43f733a3b88ad686bafe45054fd7483cdc9 [file] [log] [blame]
Holger Hildebrandtfa074992020-03-27 15:42:06 +00001/*
2 * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
3 * Copyright 2020-present Open Networking Foundation
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +00004 *
Holger Hildebrandtfa074992020-03-27 15:42:06 +00005 * Licensed under the Apache License, Version 2.0 (the "License");
6 * you may not use this file except in compliance with the License.
7 * You may obtain a copy of the License at
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +00008 *
Holger Hildebrandtfa074992020-03-27 15:42:06 +00009 * http://www.apache.org/licenses/LICENSE-2.0
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +000010 *
Holger Hildebrandtfa074992020-03-27 15:42:06 +000011 * Unless required by applicable law or agreed to in writing, software
12 * distributed under the License is distributed on an "AS IS" BASIS,
13 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
14 * See the License for the specific language governing permissions and
15 * limitations under the License.
16 */
mpagenko836a1fd2021-11-01 16:12:42 +000017/*
18 * NOTE: This file was generated, manual edits will be overwritten!
19 *
20 * Generated by 'goCodeGenerator.py':
21 * https://github.com/cboling/OMCI-parser/README.md
22 */
Holger Hildebrandtfa074992020-03-27 15:42:06 +000023
24package generated
25
26import "github.com/deckarep/golang-set"
27
28// SoftwareImageClassID is the 16-bit ID for the OMCI
29// Managed entity Software image
mpagenko836a1fd2021-11-01 16:12:42 +000030const SoftwareImageClassID = ClassID(7) // 0x0007
Holger Hildebrandtfa074992020-03-27 15:42:06 +000031
32var softwareimageBME *ManagedEntityDefinition
33
mpagenko836a1fd2021-11-01 16:12:42 +000034// SoftwareImage (Class ID: #7 / 0x0007)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000035// This ME models an executable software image stored in the ONU (documented here as its
36// fundamental usage). It may also be used to represent an opaque vendor-specific file
37// (vendorspecific usage).
38//
39// Fundamental usage
40//
41// The ONU automatically creates two instances of this ME upon the creation of each ME that
42// contains independently manageable software, either the ONU itself or an individual circuit pack.
43// It populates ME attributes according to data within the ONU or the circuit pack.
44//
45// Some pluggable equipment may not contain software. Others may contain software that is
46// intrinsically bound to the ONU's own software image. No software image ME need exist for such
47// equipment, though it may be convenient for the ONU to create them to support software version
48// audit from the OLT. In this case, the dependent MEs would support only the get action.
49//
50// A slot may contain various equipment over its lifetime, and if software image MEs exist, the ONU
51// must automatically create and delete them as the equipped configuration changes. The identity of
52// the software image is tied to the cardholder.
53//
54// When an ONU controller packs are duplicated, each can be expected to contain two software image
55// MEs, managed through reference to the individual controller packs themselves. When this occurs,
56// the ONU should not have a global pair of software images MEs (instance 0), since an action
57// (download, activate, commit) directed to instance 0 would be ambiguous.
58//
59// Relationships
60// Two instances of the software image ME are associated with each instance of the ONU or
61// cardholder whose software is independently managed.
62//
63// Attributes
64// Managed Entity Id
mpagenko836a1fd2021-11-01 16:12:42 +000065// This attribute uniquely identifies each instance of this ME. The first byte indicates the
66// physical location of the equipment hosting the software image, either the ONU (0) or a
67// cardholder (1..254). The second byte distinguishes between the two software image ME instances
68// (0..1). (R) (mandatory) (2-bytes)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000069//
70// Version
mpagenko836a1fd2021-11-01 16:12:42 +000071// This string attribute identifies the version of the software. (R) (mandatory) (14-bytes)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000072//
73// Is Committed
mpagenko836a1fd2021-11-01 16:12:42 +000074// This attribute indicates whether the associated software image is committed (1) or uncommitted
75// (0). By definition, the committed software image is loaded and executed upon reboot of the ONU
76// or circuit pack. During normal operation, one software image is always committed, while the
77// other is uncommitted. Under no circumstances are both software images allowed to be committed at
78// the same time. On the other hand, both software images could be uncommitted at the same time if
79// both were invalid. Upon ME instantiation, instance 0 is initialized to committed, while instance
80// 1 is initialized to uncommitted (i.e., the ONU ships from the factory with image 0 committed).
81// (R) (mandatory) (1-byte)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000082//
83// Is Active
mpagenko836a1fd2021-11-01 16:12:42 +000084// This attribute indicates whether the associated software image is active (1) or inactive (0). By
85// definition, the active software image is one that is currently loaded and executing in the ONU
86// or circuit pack. Under normal operation, one software image is always active while the other is
87// inactive. Under no circumstances are both software images allowed to be active at the same time.
88// On the other hand, both software images could be inactive at the same time if both were invalid.
89// (R) (mandatory) (1-byte)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000090//
91// Is Valid
mpagenko836a1fd2021-11-01 16:12:42 +000092// This attribute indicates whether the associated software image is valid (1) or invalid (0). By
93// definition, a software image is valid if it has been verified to be an executable code image.
94// The verification mechanism is not subject to standardization; however, it should include at
95// least a data integrity check [e.g., a cyclic redundancy check (CRC)] of the entire code image.
96// Upon ME instantiation or software download completion, the ONU validates the associated code
97// image and sets this attribute according to the result. (R) (mandatory) (1-byte)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000098//
99// Product Code
mpagenko836a1fd2021-11-01 16:12:42 +0000100// This attribute provides a way for a vendor to indicate product code information on a file. It is
101// a character string, padded with trailing nulls if it is shorter than 25 bytes. (R) (optional)
102// (25 bytes)
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000103//
104// Image Hash
mpagenko836a1fd2021-11-01 16:12:42 +0000105// This attribute is an MD5 hash of the software image. It is computed at completion of the end
106// download action. (R) (optional) (16-bytes)
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000107//
108type SoftwareImage struct {
109 ManagedEntityDefinition
110 Attributes AttributeValueMap
111}
112
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +0000113// Attribute name constants
114
115const SoftwareImage_Version = "Version"
116const SoftwareImage_IsCommitted = "IsCommitted"
117const SoftwareImage_IsActive = "IsActive"
118const SoftwareImage_IsValid = "IsValid"
119const SoftwareImage_ProductCode = "ProductCode"
120const SoftwareImage_ImageHash = "ImageHash"
121
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000122func init() {
123 softwareimageBME = &ManagedEntityDefinition{
124 Name: "SoftwareImage",
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +0000125 ClassID: SoftwareImageClassID,
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000126 MessageTypes: mapset.NewSetWith(
127 ActivateSoftware,
128 CommitSoftware,
129 DownloadSection,
130 EndSoftwareDownload,
131 Get,
132 StartSoftwareDownload,
133 ),
134 AllowedAttributeMask: 0xfc00,
135 AttributeDefinitions: AttributeDefinitionMap{
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +0000136 0: Uint16Field(ManagedEntityID, PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0),
137 1: MultiByteField(SoftwareImage_Version, StringAttributeType, 0x8000, 14, toOctets("ICAgICAgICAgICAgICA="), mapset.NewSetWith(Read), true, false, false, 1),
138 2: ByteField(SoftwareImage_IsCommitted, EnumerationAttributeType, 0x4000, 0, mapset.NewSetWith(Read), true, false, false, 2),
139 3: ByteField(SoftwareImage_IsActive, EnumerationAttributeType, 0x2000, 0, mapset.NewSetWith(Read), true, false, false, 3),
140 4: ByteField(SoftwareImage_IsValid, EnumerationAttributeType, 0x1000, 0, mapset.NewSetWith(Read), true, false, false, 4),
141 5: MultiByteField(SoftwareImage_ProductCode, OctetsAttributeType, 0x0800, 25, toOctets("AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA=="), mapset.NewSetWith(Read), true, true, false, 5),
142 6: MultiByteField(SoftwareImage_ImageHash, StringAttributeType, 0x0400, 16, toOctets("AAAAAAAAAAAAAAAAAAAAAA=="), mapset.NewSetWith(Read), true, true, false, 6),
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000143 },
144 Access: CreatedByOnu,
145 Support: UnknownSupport,
146 }
147}
148
149// NewSoftwareImage (class ID 7) creates the basic
150// Managed Entity definition that is used to validate an ME of this type that
151// is received from or transmitted to the OMCC.
152func NewSoftwareImage(params ...ParamData) (*ManagedEntity, OmciErrors) {
153 return NewManagedEntity(*softwareimageBME, params...)
154}