| # Copyright 2021 - present Open Networking Foundation |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| # FIXME Can we use the same test against BBSim and Hardware? |
| |
| *** Settings *** |
| Documentation Test of open ONU go adapter OMCI Get |
| Suite Setup Setup Suite |
| Test Setup Setup |
| Test Teardown Teardown |
| Suite Teardown Teardown Suite |
| Library Collections |
| Library String |
| Library OperatingSystem |
| Library XML |
| Library RequestsLibrary |
| Library ../../libraries/DependencyLibrary.py |
| Resource ../../libraries/onos.robot |
| Resource ../../libraries/voltctl.robot |
| Resource ../../libraries/voltha.robot |
| Resource ../../libraries/utils.robot |
| Resource ../../libraries/k8s.robot |
| Resource ../../variables/variables.robot |
| Resource ../../libraries/power_switch.robot |
| |
| *** Variables *** |
| ${NAMESPACE} voltha |
| ${INFRA_NAMESPACE} default |
| ${timeout} 60s |
| ${of_id} 0 |
| ${logical_id} 0 |
| ${has_dataplane} True |
| ${external_libs} True |
| ${teardown_device} True |
| ${scripts} ../../scripts |
| # Per-test logging on failure is turned off by default; set this variable to enable |
| ${container_log_dir} ${None} |
| # determines the environment workflow: DT, TT or ATT (default) |
| # example: -v workflow:DT |
| ${workflow} ATT |
| # logging flag to enable Collect Logs, can be passed via the command line too |
| # example: -v logging:True |
| ${logging} False |
| ${data_dir} ../data |
| |
| # flag to choose the subscriber provisioning command type in ONOS |
| # TT often provision a single services for a subscriber (eg: hsia, voip, ...) one after the other. |
| # if set to True, command used is "volt-add-subscriber-unitag" |
| # if set to False, comand used is "volt-add-subscriber-access" |
| ${unitag_sub} False |
| |
| *** Test Cases *** |
| ANI-G Test |
| [Documentation] Validates ANI-G output of ONU device(s): |
| [Tags] functionalOnuGo AniGTest |
| [Setup] Start Logging AniGTest |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| ${voltctl_commad} = Catenate SEPARATOR= |
| ... voltctl device getextval onu_pon_optical_info ${onu_device_id} |
| ${rc} ${output}= Run and Return Rc and Output ${voltctl_commad} |
| Should Be Equal As Integers ${rc} 0 |
| Should Contain ${output} POWER_FEED_VOLTAGE__VOLTS: |
| Should Contain ${output} 3.26 |
| Should Contain ${output} RECEIVED_OPTICAL_POWER__dBm: |
| Should Contain ${output} MEAN_OPTICAL_LAUNCH_POWER__dBm: |
| Should Contain ${output} LASER_BIAS_CURRENT__mA: |
| Should Contain ${output} TEMPERATURE__Celsius: |
| END |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Stop Logging SanityTestOnuGo |
| |
| *** Keywords *** |
| Setup Suite |
| [Documentation] Set up the test suite inclusive enable device and sanity test of given workflow |
| Start Logging Setup or Teardown Setup-${SUITE NAME} |
| Common Test Suite Setup |
| ${switch_type}= Get Variable Value ${web_power_switch.type} |
| Run Keyword If "${switch_type}"!="" Set Global Variable ${powerswitch_type} ${switch_type} |
| Setup |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT |
| ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT |
| ... ELSE Perform Sanity Test |
| Run Keyword If ${logging} Collect Logs |
| Stop Logging Setup or Teardown Setup-${SUITE NAME} |