| # Copyright 2021 - present Open Networking Foundation |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| |
| *** Settings *** |
| Documentation Negative test states of ONU Go adapter with ATT workflows only (not for DT/TT workflow!) |
| Suite Setup Setup Suite |
| Suite Teardown Teardown Suite |
| Test Setup Setup |
| Test Teardown Teardown |
| Library Collections |
| Library String |
| Library OperatingSystem |
| Library XML |
| Library RequestsLibrary |
| Library ../../libraries/DependencyLibrary.py |
| Resource ../../libraries/onos.robot |
| Resource ../../libraries/voltctl.robot |
| Resource ../../libraries/voltha.robot |
| Resource ../../libraries/utils.robot |
| Resource ../../libraries/k8s.robot |
| Resource ../../libraries/onu_utilities.robot |
| Resource ../../libraries/bbsim.robot |
| Resource ../../variables/variables.robot |
| |
| *** Variables *** |
| ${namespace} voltha |
| ${timeout} 300s |
| ${of_id} 0 |
| ${logical_id} 0 |
| ${has_dataplane} True |
| ${external_libs} True |
| ${teardown_device} True |
| ${scripts} ../../scripts |
| # Per-test logging on failure is turned off by default; set this variable to enable |
| ${container_log_dir} ${None} |
| # KV Store Prefix |
| # example: -v kvstoreprefix:voltha_voltha |
| ${kvstoreprefix} voltha_voltha |
| # used tech profile, can be passed via the command line too, valid values: default (=1T1GEM), 1T4GEM, 1T8GEM |
| # example: -v techprofile:1T4GEM |
| ${techprofile} default |
| # flag debugmode is used, if true timeout calculation various, can be passed via the command line too |
| # example: -v debugmode:True |
| ${debugmode} False |
| # logging flag to enable Collect Logs, can be passed via the command line too |
| # example: -v logging:True |
| ${logging} False |
| # if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline! |
| # example: -v pausebeforecleanup:True |
| ${pausebeforecleanup} False |
| # if True some outputs to console are done during running tests e.g. long duration flow test |
| # example: -v print2console:True |
| ${print2console} False |
| ${data_dir} ../data |
| |
| |
| *** Test Cases *** |
| ONU Negative State Test |
| [Documentation] Validates the ONU Go adapter states will never leave starting-openomci |
| ... Due to a 'omci-response-rate' lower than 8 more OMCI messages will be through away by BBSIM than |
| ... repeated by openonu-go-adapter. So ONU will never leave starting-openomci state. |
| ... Timeout has to set at least to 300s (or more) |
| [Tags] NegativeStateTestOnuGo |
| [Setup] Run Keywords Start Logging ONUNegativeStateTest |
| ... AND Setup |
| # Suite Variable will be overwritten by Teardown of Current State Test All Onus |
| Set Suite Variable ${StateTestAllONUs} True |
| ${seconds}= Convert Time ${timeout} |
| ${seconds}= Convert To String ${seconds} |
| ${seconds}= Get Substring ${seconds} 0 -2 |
| FOR ${I} IN RANGE ${seconds} |
| Sleep 1s |
| Current State Test All Onus starting-openomci timeout=1x |
| Exit For Loop If not ${StateTestAllONUs} |
| END |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Stop Logging ONUStateTest |
| |
| |
| *** Keywords *** |
| Setup Suite |
| [Documentation] Set up the test suite |
| ${LogInfo}= Catenate |
| ... \r\nPassed arguments: |
| ... techprofile:${techprofile}, |
| ... debugmode:${debugmode}, logging:${logging}, pausebeforecleanup:${pausebeforecleanup}, |
| ... print2console:${print2console} |
| Log ${LogInfo} console=yes |
| Common Test Suite Setup |
| ${techprofile}= Set Variable If "${techprofile}"=="1T1GEM" default ${techprofile} |
| Set Suite Variable ${techprofile} |
| Run Keyword If "${techprofile}"=="default" Log To Console \nTechProfile:default (1T1GEM) |
| ... ELSE IF "${techprofile}"=="1T4GEM" Set Tech Profile 1T4GEM |
| ... ELSE IF "${techprofile}"=="1T8GEM" Set Tech Profile 1T8GEM |
| ... ELSE Fail The TechProfile (${techprofile}) is not valid! |
| ${onos_ssh_connection} Open ONOS SSH Connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT} |
| Set Suite Variable ${onos_ssh_connection} |
| # delete etcd MIB Template Data |
| Delete MIB Template Data |
| # delete etcd onu data |
| Delete ONU Go Adapter ETCD Data validate=True |
| |
| Teardown Suite |
| [Documentation] Replaces the Suite Teardown in utils.robot. |
| ... Cleans up and checks all ONU ports disabled in ONOS. |
| ... Furthermore gives the possibility to pause the execution. |
| Run Keyword If ${pausebeforecleanup} Import Library Dialogs |
| Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up! |
| Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes |
| Run Keyword If ${teardown_device} Delete All Devices and Verify |
| Wait Until Keyword Succeeds ${timeout} 1s Validate Onu Data In Etcd 0 ${kvstoreprefix} without_pm_data=False |
| Wait for Ports in ONOS for all OLTs ${onos_ssh_connection} 0 BBSM ${timeout} |
| Close All ONOS SSH Connections |
| Remove Tech Profile |