blob: 9dc979330b045c8a94f1d4e89757fc202fdb3f2f [file] [log] [blame]
# Copyright 2021 - present Open Networking Foundation
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
*** Settings ***
Documentation Negative test states of ONU Go adapter with ATT workflows only (not for DT/TT workflow!)
Suite Setup Setup Suite
Suite Teardown Teardown Suite
Test Setup Setup
Test Teardown Teardown
Library Collections
Library String
Library OperatingSystem
Library XML
Library RequestsLibrary
Library ../../libraries/DependencyLibrary.py
Resource ../../libraries/onos.robot
Resource ../../libraries/voltctl.robot
Resource ../../libraries/voltha.robot
Resource ../../libraries/utils.robot
Resource ../../libraries/k8s.robot
Resource ../../libraries/onu_utilities.robot
Resource ../../libraries/bbsim.robot
Resource ../../variables/variables.robot
*** Variables ***
${namespace} voltha
${timeout} 300s
${of_id} 0
${logical_id} 0
${has_dataplane} True
${external_libs} True
${teardown_device} True
${scripts} ../../scripts
# Per-test logging on failure is turned off by default; set this variable to enable
${container_log_dir} ${None}
# KV Store Prefix
# example: -v kvstoreprefix:voltha_voltha
${kvstoreprefix} voltha_voltha
# used tech profile, can be passed via the command line too, valid values: default (=1T1GEM), 1T4GEM, 1T8GEM
# example: -v techprofile:1T4GEM
${techprofile} default
# flag debugmode is used, if true timeout calculation various, can be passed via the command line too
# example: -v debugmode:True
${debugmode} False
# logging flag to enable Collect Logs, can be passed via the command line too
# example: -v logging:True
${logging} False
# if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline!
# example: -v pausebeforecleanup:True
${pausebeforecleanup} False
# if True some outputs to console are done during running tests e.g. long duration flow test
# example: -v print2console:True
${print2console} False
${data_dir} ../data
*** Test Cases ***
ONU Negative State Test
[Documentation] Validates the ONU Go adapter states will never leave starting-openomci
... Due to a 'omci-response-rate' lower than 8 more OMCI messages will be through away by BBSIM than
... repeated by openonu-go-adapter. So ONU will never leave starting-openomci state.
... Timeout has to set at least to 300s (or more)
[Tags] NegativeStateTestOnuGo
[Setup] Run Keywords Start Logging ONUNegativeStateTest
... AND Setup
# Suite Variable will be overwritten by Teardown of Current State Test All Onus
Set Suite Variable ${StateTestAllONUs} True
${seconds}= Convert Time ${timeout}
${seconds}= Convert To String ${seconds}
${seconds}= Get Substring ${seconds} 0 -2
FOR ${I} IN RANGE ${seconds}
Sleep 1s
Current State Test All Onus starting-openomci timeout=1x
Exit For Loop If not ${StateTestAllONUs}
END
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging ONUStateTest
*** Keywords ***
Setup Suite
[Documentation] Set up the test suite
${LogInfo}= Catenate
... \r\nPassed arguments:
... techprofile:${techprofile},
... debugmode:${debugmode}, logging:${logging}, pausebeforecleanup:${pausebeforecleanup},
... print2console:${print2console}
Log ${LogInfo} console=yes
Common Test Suite Setup
${techprofile}= Set Variable If "${techprofile}"=="1T1GEM" default ${techprofile}
Set Suite Variable ${techprofile}
Run Keyword If "${techprofile}"=="default" Log To Console \nTechProfile:default (1T1GEM)
... ELSE IF "${techprofile}"=="1T4GEM" Set Tech Profile 1T4GEM
... ELSE IF "${techprofile}"=="1T8GEM" Set Tech Profile 1T8GEM
... ELSE Fail The TechProfile (${techprofile}) is not valid!
${onos_ssh_connection} Open ONOS SSH Connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
Set Suite Variable ${onos_ssh_connection}
# delete etcd MIB Template Data
Delete MIB Template Data
# delete etcd onu data
Delete ONU Go Adapter ETCD Data validate=True
Teardown Suite
[Documentation] Replaces the Suite Teardown in utils.robot.
... Cleans up and checks all ONU ports disabled in ONOS.
... Furthermore gives the possibility to pause the execution.
Run Keyword If ${pausebeforecleanup} Import Library Dialogs
Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up!
Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes
Run Keyword If ${teardown_device} Delete All Devices and Verify
Wait Until Keyword Succeeds ${timeout} 1s Validate Onu Data In Etcd 0 ${kvstoreprefix} without_pm_data=False
Wait for Ports in ONOS for all OLTs ${onos_ssh_connection} 0 BBSM ${timeout}
Close All ONOS SSH Connections
Remove Tech Profile