| # Copyright 2021 - present Open Networking Foundation |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| # FIXME Can we use the same test against BBSim and Hardware? |
| |
| *** Settings *** |
| Documentation Tests ONU Software Upgrade |
| Suite Setup Setup Suite |
| Test Setup Setup |
| Test Teardown Teardown |
| Suite Teardown Teardown Suite |
| Library Collections |
| Library String |
| Library OperatingSystem |
| Library XML |
| Library RequestsLibrary |
| Library ../../libraries/DependencyLibrary.py |
| Resource ../../libraries/onos.robot |
| Resource ../../libraries/voltctl.robot |
| Resource ../../libraries/voltha.robot |
| Resource ../../libraries/utils.robot |
| Resource ../../libraries/k8s.robot |
| Resource ../../libraries/bbsim.robot |
| Resource ../../variables/variables.robot |
| |
| *** Variables *** |
| ${POD_NAME} flex-ocp-cord |
| ${KUBERNETES_CONF} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf |
| ${KUBERNETES_CONFIGS_DIR} ~/pod-configs/kubernetes-configs |
| #${KUBERNETES_CONFIGS_DIR} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf |
| ${KUBERNETES_YAML} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.yml |
| ${HELM_CHARTS_DIR} ~/helm-charts |
| ${VOLTHA_POD_NUM} 8 |
| ${NAMESPACE} voltha |
| ${INFRA_NAMESPACE} default |
| # For below variable value, using deployment name as using grep for |
| # parsing radius pod name, we can also use full radius pod name |
| ${RESTART_POD_NAME} radius |
| ${timeout} 60s |
| ${of_id} 0 |
| ${logical_id} 0 |
| ${has_dataplane} True |
| ${teardown_device} False |
| ${scripts} ../../scripts |
| |
| # Per-test logging on failure is turned off by default; set this variable to enable |
| ${container_log_dir} ${None} |
| |
| ${suppressaddsubscriber} True |
| |
| # logging flag to enable Collect Logs, can be passed via the command line too |
| # example: -v logging:False |
| ${logging} True |
| |
| # ONU Image to test for Upgrade needs to be passed in the following format: |
| ${image_version} ${EMPTY} |
| # Example value: BBSM_IMG_00002 |
| ${image_url} ${EMPTY} |
| # Example value: http://bbsim0:50074/images/software-image.img |
| ${image_vendor} ${EMPTY} |
| # Example value: BBSM |
| ${image_activate_on_success} ${EMPTY} |
| # Example value: false |
| ${image_commit_on_success} ${EMPTY} |
| # Example value: false |
| ${image_crc} ${EMPTY} |
| # Example value: 0 |
| |
| # when voltha is running in k8s port forwarding is needed |
| # example: -v PORT_FORWARDING:False |
| ${PORT_FORWARDING} True |
| |
| # Next values are default values for port forward, do not need to be passed, will be overwritten by values taken from image-url |
| # bbsim webserver port |
| # example: -v BBSIM_WEBSERVER_PORT:50074 |
| ${BBSIM_WEBSERVER_PORT} 50074 |
| # bbsim instance |
| # example: -v BBSIM_INSTANCE:bbsim0 |
| ${BBSIM_INSTANCE} bbsim0 |
| # port forward handle |
| ${portFwdHandle} None |
| |
| *** Test Cases *** |
| Test ONU Upgrade |
| [Documentation] Validates the ONU Upgrade doesn't affect the system functionality |
| ... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable |
| ... Requirement: Pass image details in following parameters in the robot command |
| ... onu_image_name, onu_image_url, onu_image_version, onu_image_crc, onu_image_local_dir |
| ... Note: The TC expects the image url and other parameters to be common for all ONUs on all BBSim |
| ... Check [VOL-3903] for more details |
| [Tags] functional ONUUpgrade |
| [Setup] Start Logging ONUUpgrade |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Delete All Devices and Verify |
| ... AND Restart And Check BBSIM ${NAMESPACE} |
| ... AND Stop Logging ONUUpgrade |
| Do ONU Upgrade All OLTs |
| |
| Test ONU Upgrade All Activate and Commit Combinations |
| [Documentation] Validates the ONU Upgrade doesn't affect the system functionality by use all combinations of |
| ... flags activate_on_success and commit_on_success |
| ... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable |
| ... Requirement: Pass image details in following parameters in the robot command |
| ... onu_image_name, onu_image_url, onu_image_version, onu_image_crc, onu_image_local_dir |
| ... Note: The TC expects the image url and other parameters to be common for all ONUs on all BBSim |
| ... Check [VOL-4250] for more details |
| [Tags] functional ONUUpgradeAllCombies |
| [Setup] Start Logging ONUUpgradeAllCombies |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Delete All Devices and Verify |
| ... AND Restart And Check BBSIM ${NAMESPACE} |
| ... AND Stop Logging ONUUpgradeAllCombies |
| ${false_false}= Create Dictionary activate false commit false |
| ${true_false}= Create Dictionary activate true commit false |
| ${false_true}= Create Dictionary activate false commit true |
| ${true_true}= Create Dictionary activate true commit true |
| ${flag_list}= Create List ${false_false} ${true_false} ${false_true} ${true_true} |
| FOR ${item} IN @{flag_list} |
| Do ONU Upgrade All OLTs ${item['activate']} ${item['commit']} |
| Delete All Devices and Verify |
| Restart And Check BBSIM ${NAMESPACE} |
| END |
| |
| Test ONU Upgrade Correct Indication of Download Wrong Url |
| [Documentation] Validates the ONU Upgrade download from wrong URL failure will be indicated correctly |
| ... and doesn't affect the system functionality |
| ... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable |
| ... Check [VOL-4257] for more details |
| [Tags] functional ONUUpgradeDownloadWrongUrl |
| [Setup] Start Logging ONUUpgradeDownloadWrongUrl |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Delete All Devices and Verify |
| ... AND Restart And Check BBSIM ${NAMESPACE} |
| ... AND Stop Logging ONUUpgradeDownloadWrongUrl |
| # Add OLT device |
| Setup |
| # Performing Sanity Test to make sure subscribers are all DHCP and pingable |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| FOR ${J} IN RANGE 0 ${num_olts} |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${bbsim_rel}= Catenate SEPARATOR= bbsim ${J} |
| ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel} |
| Do ONU Upgrade Download Failure Per OLT ${bbsim_pod} ${olt_serial_number} |
| ... url=http://bbsim0:50074/images/wrong-image.img$ |
| ... dwl_dwlstate=DOWNLOAD_FAILED dwl_reason=INVALID_URL dwl_imgstate=IMAGE_UNKNOWN |
| ... dwlstate=DOWNLOAD_UNKNOWN reason=NO_ERROR imgstate=IMAGE_UNKNOWN |
| List ONUs ${NAMESPACE} ${bbsim_pod} |
| END |
| # Additional Verification |
| Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify |
| Setup |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| |
| Test ONU Upgrade Correct Indication of Download Failure |
| [Documentation] Validates the ONU Upgrade download failure will be indicated correctly and |
| ... doesn't affect the system functionality |
| ... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable |
| ... Check [VOL-3935] for more details |
| [Tags] functional ONUUpgradeDownloadFailure |
| [Setup] Start Logging ONUUpgradeDownloadFailure |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Delete All Devices and Verify |
| ... AND Restart And Check BBSIM ${NAMESPACE} |
| ... AND Stop Logging ONUUpgradeDownloadFailure |
| # Add OLT device |
| Setup |
| # Performing Sanity Test to make sure subscribers are all DHCP and pingable |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| FOR ${J} IN RANGE 0 ${num_olts} |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${bbsim_rel}= Catenate SEPARATOR= bbsim ${J} |
| ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel} |
| Do ONU Upgrade Download Failure Per OLT ${bbsim_pod} ${olt_serial_number} |
| ... dwlstate=DOWNLOAD_FAILED reason=CANCELLED_ON_ONU_STATE imgstate=IMAGE_UNKNOWN |
| List ONUs ${NAMESPACE} ${bbsim_pod} |
| END |
| # Additional Verification |
| Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify |
| Setup |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| |
| Test ONU Upgrade Correct Indication of Downloading Abort |
| [Documentation] Validates the ONU Upgrade downloading abort will be indicated correctly and |
| ... doesn't affect the system functionality |
| ... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable |
| ... Check [VOL-4318] for more details |
| [Tags] functional ONUUpgradeDownloadingAbort |
| [Setup] Start Logging ONUUpgradeDownloadingAbort |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Delete All Devices and Verify |
| ... AND Restart And Check BBSIM ${NAMESPACE} |
| ... AND Stop Logging ONUUpgradeDownloadingAbort |
| # Add OLT device |
| Setup |
| # Performing Sanity Test to make sure subscribers are all DHCP and pingable |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| FOR ${J} IN RANGE 0 ${num_olts} |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${bbsim_rel}= Catenate SEPARATOR= bbsim ${J} |
| ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel} |
| Do ONU Upgrade Downloading Abort Per OLT ${bbsim_pod} ${olt_serial_number} |
| List ONUs ${NAMESPACE} ${bbsim_pod} |
| END |
| # Additional Verification |
| Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify |
| Setup |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| |
| Test ONU Upgrade Correct Indication of Downloaded Abort |
| [Documentation] Validates the ONU Upgrade downloaded abort will be indicated correctly and |
| ... doesn't affect the system functionality |
| ... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable |
| ... Check [VOL-4320] for more details |
| [Tags] functional ONUUpgradeDownloadedAbort |
| [Setup] Start Logging ONUUpgradeDownloadedAbort |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Delete All Devices and Verify |
| ... AND Restart And Check BBSIM ${NAMESPACE} |
| ... AND Stop Logging ONUUpgradeDownloadedAbort |
| # Add OLT device |
| Setup |
| # Performing Sanity Test to make sure subscribers are all DHCP and pingable |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| FOR ${J} IN RANGE 0 ${num_olts} |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${bbsim_rel}= Catenate SEPARATOR= bbsim ${J} |
| ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel} |
| Do ONU Upgrade Downloaded Abort Per OLT ${bbsim_pod} ${olt_serial_number} |
| List ONUs ${NAMESPACE} ${bbsim_pod} |
| END |
| # Additional Verification |
| Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify |
| Setup |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| |
| Test ONU Upgrade Correct Indication of Activating Abort |
| [Documentation] Validates the ONU Upgrade activating abort will be indicated correctly and |
| ... doesn't affect the system functionality |
| ... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable |
| ... Check [VOL-4319] for more details |
| [Tags] functional ONUUpgradeActivatingAbort |
| [Setup] Start Logging ONUUpgradeActivatingAbort |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Delete All Devices and Verify |
| ... AND Restart And Check BBSIM ${NAMESPACE} |
| ... AND Stop Logging ONUUpgradeActivatingAbort |
| # Add OLT device |
| Setup |
| # Performing Sanity Test to make sure subscribers are all DHCP and pingable |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| FOR ${J} IN RANGE 0 ${num_olts} |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${bbsim_rel}= Catenate SEPARATOR= bbsim ${J} |
| ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel} |
| Do ONU Upgrade Activating Abort Per OLT ${bbsim_pod} ${olt_serial_number} |
| List ONUs ${NAMESPACE} ${bbsim_pod} |
| END |
| # Additional Verification |
| Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify |
| Setup |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| |
| Test ONU Upgrade Correct Indication of Active Abort |
| [Documentation] Validates the ONU Upgrade active abort will be indicated correctly and |
| ... doesn't affect the system functionality |
| ... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable |
| ... Check [VOL-4320] for more details |
| [Tags] functional ONUUpgradeActiveAbort |
| [Setup] Start Logging ONUUpgradeActiveAbort |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Delete All Devices and Verify |
| ... AND Restart And Check BBSIM ${NAMESPACE} |
| ... AND Stop Logging ONUUpgradeActiveAbort |
| # Add OLT device |
| Setup |
| # Performing Sanity Test to make sure subscribers are all DHCP and pingable |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| FOR ${J} IN RANGE 0 ${num_olts} |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${bbsim_rel}= Catenate SEPARATOR= bbsim ${J} |
| ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel} |
| Do ONU Upgrade Active Abort Per OLT ${bbsim_pod} ${olt_serial_number} |
| List ONUs ${NAMESPACE} ${bbsim_pod} |
| END |
| # Additional Verification |
| Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify |
| Setup |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| |
| Test ONU Upgrade Correct Indication of Committed Abort |
| [Documentation] Validates the ONU Upgrade committed abort will be indicated correctly and |
| ... doesn't affect the system functionality. Check BBSIM server transfer image counter after further download, |
| ... counter should be incremented. |
| ... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable |
| ... Check [VOL-4320] for more details |
| [Tags] functional ONUUpgradeCommittedAbort |
| [Setup] Start Logging ONUUpgradeCommittedAbort |
| [Teardown] Run Keywords Run Keyword If ${portFwdHandle}!=None Terminate Process ${portFwdHandle} kill=true |
| ... AND Set Suite Variable ${portFwdHandle} None |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Delete All Devices and Verify |
| ... AND Restart And Check BBSIM ${NAMESPACE} |
| ... AND Stop Logging ONUUpgradeCommittedAbort |
| # Add OLT device |
| Setup |
| # Performing Sanity Test to make sure subscribers are all DHCP and pingable |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| # in case of bbsim is running in k8s port forwarding of WEBSERVER is needed |
| ${BBSIM_INSTANCE} ${BBSIM_WEBSERVER_PORT}= Run Keyword If '${image_url}'!='${EMPTY}' Get BBSIM Svc and Webserver Port |
| ${cmd} Catenate |
| ... kubectl port-forward --address 0.0.0.0 -n ${NAMESPACE} svc/${BBSIM_INSTANCE} |
| ... ${BBSIM_WEBSERVER_PORT}:${BBSIM_WEBSERVER_PORT} & |
| ${portFwdHandle}= Run Keyword If ${PORT_FORWARDING} Start Process ${cmd} shell=true |
| Set Suite Variable ${portFwdHandle} |
| Sleep 5s |
| FOR ${J} IN RANGE 0 ${num_olts} |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${bbsim_rel}= Catenate SEPARATOR= bbsim ${J} |
| ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel} |
| Do ONU Upgrade Committed Abort Per OLT ${bbsim_pod} ${olt_serial_number} |
| List ONUs ${NAMESPACE} ${bbsim_pod} |
| END |
| # Additional Verification |
| Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify |
| Setup |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| |
| Test ONU Upgrade Correct Indication Multiple Image Download |
| [Documentation] Validates the ONU Upgrade multiple Image Download will be indicated correctly, |
| ... In case of (re-) download the same image without aborting the cached one in openonu-adapter should taken, |
| ... no further download from server has executed. Check BBSIM server transfer image counter after further download, |
| ... counter should NOT be incremented. |
| ... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable |
| ... Check [VOL-4320] for more details |
| [Tags] functional ONUUpgradeMultipleImageDownload |
| [Setup] Start Logging ONUUpgradeMultipleImageDownload |
| [Teardown] Run Keywords Run Keyword If ${portFwdHandle}!=None Terminate Process ${portFwdHandle} kill=true |
| ... AND Set Suite Variable ${portFwdHandle} None |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Delete All Devices and Verify |
| ... AND Restart And Check BBSIM ${NAMESPACE} |
| ... AND Stop Logging ONUUpgradeMultipleImageDownload |
| # Add OLT device |
| Setup |
| # Performing Sanity Test to make sure subscribers are all DHCP and pingable |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| # in case of bbsim is running in k8s port forwarding of WEBSERVER is needed |
| ${BBSIM_INSTANCE} ${BBSIM_WEBSERVER_PORT}= Run Keyword If '${image_url}'!='${EMPTY}' Get BBSIM Svc and Webserver Port |
| ${cmd} Catenate |
| ... kubectl port-forward --address 0.0.0.0 -n ${NAMESPACE} svc/${BBSIM_INSTANCE} |
| ... ${BBSIM_WEBSERVER_PORT}:${BBSIM_WEBSERVER_PORT} & |
| ${portFwdHandle}= Run Keyword If ${PORT_FORWARDING} Start Process ${cmd} shell=true |
| Set Suite Variable ${portFwdHandle} |
| Sleep 5s |
| FOR ${J} IN RANGE 0 ${num_olts} |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${bbsim_rel}= Catenate SEPARATOR= bbsim ${J} |
| ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel} |
| Do ONU Upgrade Multiple Image Download Per OLT ${bbsim_pod} ${olt_serial_number} |
| List ONUs ${NAMESPACE} ${bbsim_pod} |
| END |
| # Additional Verification |
| Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify |
| Setup |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| |
| Test ONU Upgrade Image Download Simultaneously |
| [Documentation] Validates the ONU Upgrade Image Download to all ONUs simultaneously. |
| ... Test case should executed in multiple ONU (OLT) environment! |
| ... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable |
| ... Check [VOL-4320] for more details |
| [Tags] functionalMultipleONUs ONUUpgradeImageDownloadSimultaneously |
| [Setup] Start Logging ONUUpgradeImageDownloadSimultaneously |
| [Teardown] Run Keywords Run Keyword If ${portFwdHandle}!=None Terminate Process ${portFwdHandle} kill=true |
| ... AND Set Suite Variable ${portFwdHandle} None |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Delete All Devices and Verify |
| ... AND Restart And Check BBSIM ${NAMESPACE} |
| ... AND Stop Logging ONUUpgradeImageDownloadSimultaneously |
| # Add OLT device |
| Setup |
| # Performing Sanity Test to make sure subscribers are all DHCP and pingable |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| # in case of bbsim is running in k8s port forwarding of WEBSERVER is needed |
| ${BBSIM_INSTANCE} ${BBSIM_WEBSERVER_PORT}= Run Keyword If '${image_url}'!='${EMPTY}' Get BBSIM Svc and Webserver Port |
| ${cmd} Catenate |
| ... kubectl port-forward --address 0.0.0.0 -n ${NAMESPACE} svc/${BBSIM_INSTANCE} |
| ... ${BBSIM_WEBSERVER_PORT}:${BBSIM_WEBSERVER_PORT} & |
| ${portFwdHandle}= Run Keyword If ${PORT_FORWARDING} Start Process ${cmd} shell=true |
| Set Suite Variable ${portFwdHandle} |
| Sleep 5s |
| Do ONU Upgrade Image Download Simultaneously |
| # Additional Verification |
| Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify |
| Setup |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| |
| *** Keywords *** |
| Do ONU Upgrade All OLTs |
| [Documentation] This keyword performs the ONU Upgrade test on all OLTs |
| [Arguments] ${activate_on_success}=${image_activate_on_success} ${commit_on_success}=${image_commit_on_success} |
| # Add OLT device |
| Setup |
| # Performing Sanity Test to make sure subscribers are all DHCP and pingable |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| FOR ${J} IN RANGE 0 ${num_olts} |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${bbsim_rel}= Catenate SEPARATOR= bbsim ${J} |
| ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel} |
| Do ONU Upgrade Per OLT ${bbsim_pod} ${olt_serial_number} ${activate_on_success} ${commit_on_success} |
| List ONUs ${NAMESPACE} ${bbsim_pod} |
| END |
| # Additional Verification |
| Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify |
| Setup |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test |
| |
| Do ONU Upgrade Per OLT |
| [Documentation] This keyword performs the ONU Upgrade test on single OLT |
| [Arguments] ${bbsim_pod} ${olt_serial_number} ${activate_on_success}=${image_activate_on_success} |
| ... ${commit_on_success}=${image_commit_on_success} |
| [Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image ${image_version} ${onu_device_id} |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${dst}= Set Variable ${hosts.dst[${I}]} |
| Continue For Loop If "${olt_serial_number}"!="${src['olt']}" |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| # Download Image |
| Download ONU Device Image ${image_version} ${image_url} ${image_vendor} |
| ... ${activate_on_success} ${commit_on_success} |
| ... ${image_crc} ${onu_device_id} |
| ${imageState}= Run Keyword If '${activate_on_success}'=='true' and '${commit_on_success}'=='false' |
| ... Set Variable IMAGE_ACTIVE |
| ... ELSE IF '${activate_on_success}'=='true' and '${commit_on_success}'=='true' |
| ... Set Variable IMAGE_COMMITTED |
| ... ELSE Set Variable IMAGE_INACTIVE |
| ${activated}= Set Variable If '${activate_on_success}'=='true' True False |
| ${committed}= Set Variable If '${activate_on_success}'=='true' and '${commit_on_success}'=='true' |
| ... True False |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR ${imageState} |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id} |
| ... ${image_version} ${committed} ${activated} True |
| # Activate Image |
| ${imageState}= Set Variable If '${commit_on_success}'=='true' IMAGE_COMMITTED IMAGE_ACTIVE |
| ${committed}= Set Variable If '${commit_on_success}'=='true' True False |
| Run Keyword If '${activate_on_success}'=='false' Run Keywords |
| ... Activate ONU Device Image ${image_version} ${commit_on_success} ${onu_device_id} |
| ... AND Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR ${imageState} |
| ... AND Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id} |
| ... ${image_version} ${committed} True True |
| # Commit Image |
| Run Keyword If '${commit_on_success}'=='false' Run Keywords |
| ... Commit ONU Device Image ${image_version} ${onu_device_id} |
| ... AND Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_COMMITTED |
| ... AND Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id} |
| ... ${image_version} True True True |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image On BBSim ${NAMESPACE} ${bbsim_pod} |
| ... ${src['onu']} software_image_committed |
| Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber} |
| # to remove the image again from adapter, Multi-Onu tests could be restructured - not yet in focus |
| Remove Adapter Image ${image_version} ${onu_device_id} |
| END |
| |
| Do ONU Upgrade Download Failure Per OLT |
| [Documentation] This keyword performs the ONU Upgrade Dowload Failure test on single OLT |
| [Arguments] ${bbsim_pod} ${olt_serial_number} ${url}=${image_url} |
| ... ${dwl_dwlstate}=DOWNLOAD_STARTED ${dwl_reason}=NO_ERROR ${dwl_imgstate}=IMAGE_UNKNOWN |
| ... ${dwlstate}=DOWNLOAD_SUCCEEDED ${reason}=NO_ERROR ${imgstate}=IMAGE_INACTIVE |
| [Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image INVALID_IMAGE ${onu_device_id} |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${dst}= Set Variable ${hosts.dst[${I}]} |
| Continue For Loop If "${olt_serial_number}"!="${src['olt']}" |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| # Download Image |
| Download ONU Device Image INVALID_IMAGE ${url} ${image_vendor} |
| ... ${image_activate_on_success} ${image_commit_on_success} ${image_crc} ${onu_device_id} |
| ... download_state=${dwl_dwlstate} expected_reason=${dwl_reason} image_state=${dwl_imgstate} |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status INVALID_IMAGE |
| ... ${onu_device_id} ${dwlstate} ${reason} ${imgstate} |
| Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber} |
| # to remove the image again from adapter, Multi-Onu tests could be restructured - not yet in focus |
| Remove Adapter Image INVALID_IMAGE ${onu_device_id} |
| END |
| |
| Do ONU Upgrade Downloading Abort Per OLT |
| [Documentation] This keyword performs the ONU Upgrade Downloading Abort test on single OLT |
| [Arguments] ${bbsim_pod} ${olt_serial_number} ${url}=${image_url} |
| [Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image ${image_version} ${onu_device_id} |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${dst}= Set Variable ${hosts.dst[${I}]} |
| Continue For Loop If "${olt_serial_number}"!="${src['olt']}" |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| # Download Image |
| Download ONU Device Image ${image_version} ${url} ${image_vendor} |
| ... ${image_activate_on_success} ${image_commit_on_success} ${image_crc} ${onu_device_id} |
| Abort ONU Device Image ${image_version} ${onu_device_id} |
| ... DOWNLOAD_STARTED CANCELLED_ON_REQUEST IMAGE_DOWNLOADING |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_CANCELLED CANCELLED_ON_REQUEST IMAGE_UNKNOWN |
| # !!! Expected is image is not visible in list !!! |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id} |
| ... ${image_version} False False True |
| Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber} |
| END |
| |
| Do ONU Upgrade Downloaded Abort Per OLT |
| [Documentation] This keyword performs the ONU Upgrade Downloaded Abort test on single OLT |
| [Arguments] ${bbsim_pod} ${olt_serial_number} ${url}=${image_url} |
| [Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image ${image_version} ${onu_device_id} |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${dst}= Set Variable ${hosts.dst[${I}]} |
| Continue For Loop If "${olt_serial_number}"!="${src['olt']}" |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| # Download Image |
| Download ONU Device Image ${image_version} ${url} ${image_vendor} |
| ... false false ${image_crc} ${onu_device_id} |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_INACTIVE |
| Abort ONU Device Image ${image_version} ${onu_device_id} |
| ... DOWNLOAD_SUCCEEDED CANCELLED_ON_REQUEST IMAGE_INACTIVE |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_SUCCEEDED CANCELLED_ON_REQUEST IMAGE_INACTIVE |
| # !!! Expected is image is not visible in list !!! |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id} |
| ... ${image_version} False False True |
| Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber} |
| END |
| |
| Do ONU Upgrade Activating Abort Per OLT |
| [Documentation] This keyword performs the ONU Upgrade Activating Abort test on single OLT |
| [Arguments] ${bbsim_pod} ${olt_serial_number} ${url}=${image_url} |
| [Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image ${image_version} ${onu_device_id} |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${dst}= Set Variable ${hosts.dst[${I}]} |
| Continue For Loop If "${olt_serial_number}"!="${src['olt']}" |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| # Download Image |
| Download ONU Device Image ${image_version} ${url} ${image_vendor} |
| ... false false ${image_crc} ${onu_device_id} |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_INACTIVE |
| Activate ONU Device Image ${image_version} false ${onu_device_id} |
| Abort ONU Device Image ${image_version} ${onu_device_id} |
| ... DOWNLOAD_SUCCEEDED CANCELLED_ON_REQUEST IMAGE_ACTIVATING |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_SUCCEEDED CANCELLED_ON_REQUEST IMAGE_ACTIVATION_ABORTED |
| # !!! Expected is image is not visible in list !!! |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id} |
| ... ${image_version} False True True |
| Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber} |
| END |
| |
| Do ONU Upgrade Active Abort Per OLT |
| [Documentation] This keyword performs the ONU Upgrade Active Abort test on single OLT |
| [Arguments] ${bbsim_pod} ${olt_serial_number} ${url}=${image_url} |
| [Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image ${image_version} ${onu_device_id} |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${dst}= Set Variable ${hosts.dst[${I}]} |
| Continue For Loop If "${olt_serial_number}"!="${src['olt']}" |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| # Download Image |
| Download ONU Device Image ${image_version} ${url} ${image_vendor} |
| ... false false ${image_crc} ${onu_device_id} |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_INACTIVE |
| Activate ONU Device Image ${image_version} false ${onu_device_id} |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_ACTIVE |
| Abort ONU Device Image ${image_version} ${onu_device_id} |
| ... DOWNLOAD_SUCCEEDED CANCELLED_ON_REQUEST IMAGE_ACTIVE |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_SUCCEEDED CANCELLED_ON_REQUEST IMAGE_ACTIVE |
| # !!! Expected is image is not visible in list !!! |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id} |
| ... ${image_version} False True True |
| Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber} |
| END |
| |
| Do ONU Upgrade Committed Abort Per OLT |
| [Documentation] This keyword performs the ONU Upgrade Committed Abort test on single OLT |
| [Arguments] ${bbsim_pod} ${olt_serial_number} ${url}=${image_url} |
| [Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image ${image_version} ${onu_device_id} |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${dst}= Set Variable ${hosts.dst[${I}]} |
| Continue For Loop If "${olt_serial_number}"!="${src['olt']}" |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| ${Images_Count_Start}= Get Images Count |
| # Download Image |
| Download ONU Device Image ${image_version} ${url} ${image_vendor} |
| ... false false ${image_crc} ${onu_device_id} |
| # After download of image, check image counter of BBSIM, has to be incremented by 2, because bbsim increments counter |
| # whenever openonu adapter touch the image, so one increment for check image is available and one for downloading |
| ${Images_Count_First}= Get Images Count |
| ${Images_Count_Start}= Evaluate ${Images_Count_Start}+2 |
| Should Be Equal as Integers ${Images_Count_First} ${Images_Count_Start} Count of image download not correct! |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_INACTIVE |
| Activate ONU Device Image ${image_version} false ${onu_device_id} |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_ACTIVE |
| Commit ONU Device Image ${image_version} ${onu_device_id} |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_COMMITTED |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id} |
| ... ${image_version} True True True |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image On BBSim ${NAMESPACE} ${bbsim_pod} |
| ... ${src['onu']} software_image_committed |
| Abort ONU Device Image ${image_version} ${onu_device_id} |
| ... DOWNLOAD_UNKNOWN NO_ERROR IMAGE_UNKNOWN |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_UNKNOWN NO_ERROR IMAGE_UNKNOWN |
| # !!! Expected is image is not visible in list !!! |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id} |
| ... ${image_version} True True True |
| Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber} |
| ${Images_Count_Intermediate}= Get Images Count |
| # Repeat download of aborted image, check image counter of BBSIM, has to be incremented by 2, because bbsim increments |
| # whenever openonu adapter touch the image, so one increment for check image is available and one for downloading |
| Download ONU Device Image ${image_version} ${url} ${image_vendor} |
| ... false false ${image_crc} ${onu_device_id} |
| ${Images_Count_End}= Get Images Count |
| ${Images_Count_Intermediate}= Evaluate ${Images_Count_Intermediate}+2 |
| Should Be Equal as Integers ${Images_Count_End} ${Images_Count_Intermediate} Count of image download not correct! |
| Remove Adapter Image ${image_version} ${onu_device_id} |
| END |
| |
| Do ONU Upgrade Multiple Image Download Per OLT |
| [Documentation] This keyword performs the ONU Upgrade Image Download test on single OLT |
| [Arguments] ${bbsim_pod} ${olt_serial_number} ${url}=${image_url} |
| [Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image ${image_version} ${onu_device_id} |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${dst}= Set Variable ${hosts.dst[${I}]} |
| Continue For Loop If "${olt_serial_number}"!="${src['olt']}" |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| ${Images_Count_Start}= Get Images Count |
| # Download Image |
| Download ONU Device Image ${image_version} ${url} ${image_vendor} |
| ... true true ${image_crc} ${onu_device_id} |
| # After download of image, check image counter of BBSIM, has to be incremented by 2, because bbsim increments counter |
| # whenever openonu adapter touch the image, so one increment for check image is available and one for downloading |
| ${Images_Count_First}= Get Images Count |
| ${Images_Count_Start}= Evaluate ${Images_Count_Start}+2 |
| Should Be Equal as Integers ${Images_Count_First} ${Images_Count_Start} Count of image download not correct! |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_COMMITTED |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id} |
| ... ${image_version} True True True |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image On BBSim ${NAMESPACE} ${bbsim_pod} |
| ... ${src['onu']} software_image_committed |
| Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber} |
| ${Images_Count_Intermediate}= Get Images Count |
| # Repeat download of same image, check image counter of BBSIM, has to be not incremented, because no download from |
| # server will be executed, the cached one from openonu-adapter will taken |
| Download ONU Device Image ${image_version} ${url} ${image_vendor} |
| ... false false ${image_crc} ${onu_device_id} |
| ${Images_Count_End}= Get Images Count |
| Should Be Equal as Integers ${Images_Count_End} ${Images_Count_Intermediate} Count of image download not correct! |
| Remove Adapter Image ${image_version} ${onu_device_id} |
| END |
| |
| Do ONU Upgrade Image Download Simultaneously |
| [Documentation] This keyword performs the ONU Upgrade Image Download Simultaneously on all ONUs test |
| [Arguments] ${url}=${image_url} |
| [Teardown] Remove Adapter Image from ONUs ${image_version} ${list_onus} |
| # collect all ONU's device ids |
| ${list_onus} Create List |
| Build ONU Device Id List ${list_onus} |
| # prepare OLT-SN BBSIM-POD releation dictionary for later fast access |
| ${olt_bbsim_dict}= Create Dictionary |
| FOR ${J} IN RANGE 0 ${num_olts} |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${bbsim_rel}= Catenate SEPARATOR= bbsim ${J} |
| ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel} |
| Set To Dictionary ${olt_bbsim_dict} ${olt_serial_number} ${bbsim_pod} |
| END |
| ${Images_Count_Start}= Get Images Count |
| # Download Image to all ONUs simultaneously |
| ${onu_device_ids} = Catenate @{list_onus} |
| Download ONU Device Image ${image_version} ${url} ${image_vendor} |
| ... true true ${image_crc} ${onu_device_ids} |
| # do all the check stuff |
| FOR ${onu_device_id} IN @{list_onus} |
| Log ${onu_device_id} |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version} |
| ... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_COMMITTED |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id} |
| ... ${image_version} True True True |
| END |
| # last but not least check bbsim |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${bbsim_pod}= Get From Dictionary ${olt_bbsim_dict} ${src['olt']} |
| Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image On BBSim ${NAMESPACE} ${bbsim_pod} |
| ... ${src['onu']} software_image_committed |
| END |
| ${Images_Count_End}= Get Images Count |
| ${Images_Count_Start}= Evaluate ${Images_Count_Start}+2 |
| Should Be Equal as Integers ${Images_Count_End} ${Images_Count_Start} Count of image download not correct! |
| |
| Restart And Check BBSIM |
| [Documentation] This keyword restarts bbsim and waits for it to come up again |
| ... Following steps will be executed: |
| ... - restart bbsim adaptor |
| ... - check bbsim adaptor is ready again |
| [Arguments] ${namespace} |
| ${bbsim_apps} Create List bbsim |
| ${label_key} Set Variable app |
| ${bbsim_label_value} Set Variable bbsim |
| Restart Pod By Label ${namespace} ${label_key} ${bbsim_label_value} |
| Sleep 5s |
| Wait For Pods Ready ${namespace} ${bbsim_apps} |
| |
| Get BBSIM Svc and Webserver Port |
| [Documentation] This keyword gets bbsim instance and bbsim webserver port from image url |
| @{words}= Split String ${image_url} / |
| ${SvcAndPort} Set Variable @{words}[2] |
| ${bbsim_svc} ${webserver_port}= Split String ${SvcAndPort} : 1 |
| ${svc_return} Set Variable If '${bbsim_svc}'!='${EMPTY}' ${bbsim_svc} ${BBSIM_INSTANCE} |
| ${port_return} Set Variable If '${webserver_port}'!='${EMPTY}' ${webserver_port} ${BBSIM_WEBSERVER_PORT} |
| [Return] ${svc_return} ${port_return} |
| |
| Setup Suite |
| [Documentation] Set up the test suite |
| Start Logging Setup or Teardown Setup-${SUITE NAME} |
| Common Test Suite Setup |
| Run Keyword If ${logging} Collect Logs |
| Stop Logging Setup or Teardown Setup-${SUITE NAME} |
| |
| Teardown Suite |
| [Documentation] Tear down steps for the suite |
| Start Logging Setup or Teardown Teardown-${SUITE NAME} |
| # stop port forwarding if still running |
| Run Keyword If ${portFwdHandle}!=None Terminate Process ${portFwdHandle} kill=true |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Run Keyword If ${logging} Collect Logs |
| Stop Logging Setup or Teardown Teardown-${SUITE NAME} |
| Close All ONOS SSH Connections |