| # Copyright 2020 - present Open Networking Foundation |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| |
| *** Settings *** |
| Documentation Test states of ONU Go adapter with ATT workflows only (not for DT/TT workflow!) |
| Suite Setup Setup Suite |
| Suite Teardown Teardown Suite |
| Test Setup Setup |
| Test Teardown Teardown |
| Library Collections |
| Library String |
| Library OperatingSystem |
| Library XML |
| Library RequestsLibrary |
| Library ../../libraries/DependencyLibrary.py |
| Resource ../../libraries/onos.robot |
| Resource ../../libraries/voltctl.robot |
| Resource ../../libraries/voltha.robot |
| Resource ../../libraries/utils.robot |
| Resource ../../libraries/k8s.robot |
| Resource ../../libraries/onu_utilities.robot |
| Resource ../../libraries/bbsim.robot |
| Resource ../../variables/variables.robot |
| |
| *** Variables *** |
| ${namespace} voltha |
| ${INFRA_NAMESPACE} default |
| ${timeout} 60s |
| ${of_id} 0 |
| ${logical_id} 0 |
| ${has_dataplane} True |
| ${external_libs} True |
| ${teardown_device} True |
| ${scripts} ../../scripts |
| # Per-test logging on failure is turned off by default; set this variable to enable |
| ${container_log_dir} ${None} |
| # KV Store Prefix |
| # example: -v kvstoreprefix:voltha_voltha |
| ${kvstoreprefix} voltha_voltha |
| # state to test variable, can be passed via the command line too, valid values: 1-6 |
| # 1 -> activating-onu |
| # 2 -> starting-openomci |
| # 3 -> discovery-mibsync-complete |
| # 4 -> initial-mib-downloaded |
| # 5 -> tech-profile-config-download-success |
| # 6 -> omci-flows-pushed |
| # example: -v state2test:5 |
| # example: -v state2test:omci-flows-pushed |
| ${state2test} 6 |
| # test mode variable, can be passed via the command line too, valid values: SingleState, Up2State, SingleStateTime |
| # example: -v testmode:SingleStateTime |
| ${testmode} SingleState |
| # used tech profile, can be passed via the command line too, valid values: default (=1T1GEM), 1T4GEM, 1T8GEM |
| # example: -v techprofile:1T4GEM |
| ${techprofile} default |
| # flag debugmode is used, if true timeout calculation various, can be passed via the command line too |
| # example: -v debugmode:True |
| ${debugmode} False |
| # logging flag to enable Collect Logs, can be passed via the command line too |
| # example: -v logging:True |
| ${logging} False |
| # if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline! |
| # example: -v pausebeforecleanup:True |
| ${pausebeforecleanup} False |
| # if True some outputs to console are done during running tests e.g. long duration flow test |
| # example: -v print2console:True |
| ${print2console} False |
| ${data_dir} ../data |
| |
| |
| *** Test Cases *** |
| ONU State Test |
| [Documentation] Validates the ONU Go adapter states |
| [Tags] sanityOnuGo StateTestOnuGo |
| [Setup] Run Keywords Start Logging ONUStateTest |
| ... AND Setup Test |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| FOR ${I} IN RANGE 0 ${num_olts} |
| #get olt serial number |
| ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| #validate olt states |
| ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number} |
| Enable Device ${olt_device_id} |
| END |
| ${timeStart} = Get Current Date |
| Set Global Variable ${timeStart} |
| Run Keyword If "${testmode}"=="SingleState" Do ONU Single State Test |
| ... ELSE IF "${testmode}"=="Up2State" Do ONU Up To State Test |
| ... ELSE IF "${testmode}"=="SingleStateTime" Do ONU Single State Test Time |
| ... ELSE Fail The testmode (${testmode}) is not valid! |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Stop Logging ONUStateTest |
| |
| Check Loaded Tech Profile |
| [Documentation] Validates the loaded Tech Profile |
| ... Assuming that ONU State Test was executed where all the ONUs are reached the expected state! |
| ... Check will be executed only the reached ONU state is 5 (tech-profile-config-download-success) or higher |
| [Tags] functionalOnuGo CheckTechProfileOnuGo |
| [Setup] Start Logging ONUCheckTechProfile |
| Run Keyword If '${onu_state}'=='tech-profile-config-download-success' or '${onu_state}'=='omci-flows-pushed' |
| ... Do Check Tech Profile |
| ... ELSE Pass Execution ${skip_message} skipped |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Stop Logging ONUCheckTechProfile |
| |
| Onu Port Check |
| [Documentation] Validates that all the UNI ports show up in ONOS |
| ... Assuming that ONU State Test was executed where all the ONUs are reached the expected state! |
| [Tags] functionalOnuGo PortTestOnuGo |
| [Setup] Start Logging ONUPortTest |
| Run Keyword If '${onu_state}'=='tech-profile-config-download-success' or '${onu_state}'=='omci-flows-pushed' |
| ... Do Onu Port Check |
| ... ELSE Pass Execution ${skip_message} skipped |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Stop Logging ONUPortTest |
| |
| Onu Etcd Data Check |
| [Documentation] Validates ONU data stored in ETCD |
| ... Assuming that ONU State Test was executed where all the ONUs are reached the expected state! |
| [Tags] functionalOnuGo EtcdDataOnuGo |
| [Setup] Start Logging ONUEtcdDataTest |
| Run Keyword If '${onu_state}'=='tech-profile-config-download-success' or '${onu_state}'=='omci-flows-pushed' |
| ... Do Onu Etcd Data Check |
| ... ELSE Pass Execution ${skip_message} skipped |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Stop Logging ONUEtcdDataTest |
| |
| Onu Flow Check |
| [Documentation] Validates the onu flows in ONOS and Voltha |
| ... Assuming that ONU State Test was executed where all the ONUs are reached the expected state! |
| [Tags] functionalOnuGo FlowTestOnuGo |
| [Setup] Start Logging ONUFlowTest |
| Run Keyword If '${onu_state}'=='omci-flows-pushed' Do Onu Flow Check |
| ... ELSE Pass Execution ${skip_message} skipped |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Stop Logging ONUFlowTest |
| |
| Disable Enable Onu Device |
| [Documentation] Disables/enables ONU Device and check states |
| ... Assuming that ONU State Test was executed where all the ONUs are reached the expected state! |
| [Tags] functionalOnuGo DisableEnableOnuGo |
| [Setup] Start Logging DisableEnableONUDevice |
| Run Keyword If '${onu_state}'=='tech-profile-config-download-success' or '${onu_state}'=='omci-flows-pushed' |
| ... Do Disable Enable Onu Test |
| ... ELSE Pass Execution ${skip_message} skipped |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Stop Logging DisableEnableONUDevice |
| |
| Power Off Power On Onu Device |
| [Documentation] Power off and Power on of all ONU Devices and check state |
| ... Assuming that ONU State Test was executed where all the ONUs are reached the expected state! |
| [Tags] functionalOnuGo PowerOffPowerOnOnuGo |
| [Setup] Start Logging PowerOffPowerOnONUDevice |
| Run Keyword If '${onu_state}'=='tech-profile-config-download-success' or '${onu_state}'=='omci-flows-pushed' |
| ... Do Power Off Power On Onu Device |
| ... ELSE Pass Execution ${skip_message} skipped |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Stop Logging PowerOffPowerOnONUDevice |
| |
| Soft Reboot Onu Device |
| [Documentation] Reboots softly all ONU Devices and check state |
| ... Assuming that ONU State Test was executed where all the ONUs are reached the expected state! |
| [Tags] functionalOnuGo SoftRebootOnuGo |
| [Setup] Start Logging SoftRebootONUDevice |
| Run Keyword If '${onu_state}'=='tech-profile-config-download-success' or '${onu_state}'=='omci-flows-pushed' |
| ... Do Soft Reboot Onu Device |
| ... ELSE Pass Execution ${skip_message} skipped |
| [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs |
| ... AND Stop Logging SoftRebootONUDevice |
| |
| *** Keywords *** |
| Setup Suite |
| [Documentation] Set up the test suite |
| Start Logging Setup or Teardown Setup-${SUITE NAME} |
| ${LogInfo}= Catenate |
| ... \r\nPassed arguments: |
| ... state2test:${state2test}, testmode:${testmode}, techprofile:${techprofile}, |
| ... debugmode:${debugmode}, logging:${logging}, pausebeforecleanup:${pausebeforecleanup}, |
| ... print2console:${print2console}, kvstoreprefix:${kvstoreprefix} |
| Log ${LogInfo} console=yes |
| Common Test Suite Setup |
| # prepare skip message in yellow for console log |
| ${skip}= Evaluate "\\033[33mSKIP\\033[0m" |
| ${skipped}= Evaluate "\\033[33m${SPACE*14} ===> Test case above was skipped! <=== ${SPACE*15}\\033[0m" |
| ${skip_message} Catenate ${skipped} | ${skip} | |
| Set Suite Variable ${skip_message} |
| ${all_onu_timeout}= Run Keyword If ${num_all_onus}>4 Calculate Timeout ${timeout} |
| ... ELSE Set Variable ${timeout} |
| Set Suite Variable ${all_onu_timeout} |
| ${techprofile}= Set Variable If "${techprofile}"=="1T1GEM" default ${techprofile} |
| Set Suite Variable ${techprofile} |
| Run Keyword If "${techprofile}"=="default" Log To Console \nTechProfile:default (1T1GEM) |
| ... ELSE IF "${techprofile}"=="1T4GEM" Set Tech Profile 1T4GEM |
| ... ELSE IF "${techprofile}"=="1T8GEM" Set Tech Profile 1T8GEM |
| ... ELSE Fail The TechProfile (${techprofile}) is not valid! |
| # map the passed onu state to reached and make it visible for test suite |
| ${admin_state} ${oper_status} ${connect_status} ${onu_state_nb} ${onu_state}= |
| ... Map State ${state2test} |
| Set Suite Variable ${admin_state} |
| Set Suite Variable ${oper_status} |
| Set Suite Variable ${connect_status} |
| Set Suite Variable ${onu_state_nb} |
| Set Suite Variable ${onu_state} |
| # delete etcd MIB Template Data |
| Delete MIB Template Data |
| # delete etcd onu data |
| Delete ONU Go Adapter ETCD Data validate=True |
| Run Keyword If ${logging} Collect Logs |
| Stop Logging Setup or Teardown Setup-${SUITE NAME} |
| |
| Teardown Suite |
| [Documentation] Replaces the Suite Teardown in utils.robot. |
| ... Cleans up and checks all ONU ports disabled in ONOS. |
| ... Furthermore gives the possibility to pause the execution. |
| Start Logging Setup or Teardown Teardown-${SUITE NAME} |
| Run Keyword If ${pausebeforecleanup} Import Library Dialogs |
| Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up! |
| Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes |
| Run Keyword If ${teardown_device} Delete All Devices and Verify |
| Wait Until Keyword Succeeds ${timeout} 1s Validate Onu Data In Etcd 0 ${kvstoreprefix} without_pm_data=False |
| Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} 0 BBSM ${timeout} |
| Run Keyword If ${logging} Collect Logs |
| Close All ONOS SSH Connections |
| Remove Tech Profile |
| Stop Logging Setup or Teardown Teardown-${SUITE NAME} |
| |
| Setup Test |
| [Documentation] Pre-test Setup |
| #test for empty device list |
| Test Empty Device List |
| Run Keyword If ${has_dataplane} Wait Until Keyword Succeeds 120s 10s Openolt is Up |
| ... ${olt_ssh_ip} ${olt_user} ${olt_pass} |
| Run Keyword If ${has_dataplane} Sleep 60s |
| # Create a list of olt ids (logical and device_id) |
| ${olt_ids} Create List |
| FOR ${I} IN RANGE 0 ${num_olts} |
| #create/preprovision device |
| ${olt_device_id}= Run Keyword If "${list_olts}[${I}][type]" == "${None}" |
| ... Create Device ${list_olts}[${I}][ip] ${list_olts}[${I}][oltport] |
| ... ELSE Create Device ${list_olts}[${I}][ip] ${list_olts}[${I}][oltport] ${list_olts}[${I}][type] |
| ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| #validate olt states |
| Wait Until Keyword Succeeds ${timeout} 5s |
| ... Validate OLT Device PREPROVISIONED UNKNOWN UNKNOWN ${olt_device_id} by_dev_id=True |
| Sleep 5s |
| ${logical_id}= Get Logical Device ID From SN ${olt_serial_number} |
| ${olt} Create Dictionary device_id ${olt_device_id} logical_id ${logical_id} |
| ... of_id ${of_id} sn ${olt_serial_number} |
| Append To List ${olt_ids} ${olt} |
| END |
| Set Global Variable ${olt_ids} |
| |
| Do ONU Up To State Test |
| [Documentation] This keyword performs Up2State Test |
| ... All states up to the passed have to be checked |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${dst}= Set Variable ${hosts.dst[${I}]} |
| Run Keyword If ${onu_state_nb}>=1 |
| ... Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms |
| ... Validate Device ENABLED ACTIVATING REACHABLE |
| ... ${src['onu']} onu=True onu_reason=activating-onu |
| Run Keyword If ${onu_state_nb}>=2 |
| ... Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms |
| ... Validate Device ENABLED ACTIVATING REACHABLE |
| ... ${src['onu']} onu=True onu_reason=starting-openomci |
| Run Keyword If ${onu_state_nb}>=3 |
| ... Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms |
| ... Validate Device ENABLED ACTIVATING REACHABLE |
| ... ${src['onu']} onu=True onu_reason=discovery-mibsync-complete |
| Run Keyword If ${onu_state_nb}>=4 |
| ... Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms |
| ... Validate Device ENABLED ACTIVE REACHABLE |
| ... ${src['onu']} onu=True onu_reason=initial-mib-downloaded |
| Run Keyword If ${onu_state_nb}>=5 |
| ... Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms |
| ... Validate Device ENABLED ACTIVE REACHABLE |
| ... ${src['onu']} onu=True onu_reason=tech-profile-config-download-success |
| Run Keyword If ${onu_state_nb}>=6 |
| ... Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms |
| ... Validate Device ENABLED ACTIVE REACHABLE |
| ... ${src['onu']} onu=True onu_reason=omci-flows-pushed |
| END |
| |
| Do ONU Single State Test |
| [Documentation] This keyword performs SingleState Test |
| ... Only the passed state has to be checked |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${dst}= Set Variable ${hosts.dst[${I}]} |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms |
| ... Validate Device ${admin_state} ${oper_status} ${connect_status} |
| ... ${src['onu']} onu=True onu_reason=${onu_state} |
| END |
| |
| Do ONU Single State Test Time |
| [Documentation] This keyword performs SingleState Test with calculate running time |
| ... Only the passed state has to be checked and the duration each single onu adapter needed |
| ... will be calculated and printed out |
| #${ListfinishedONUs} Create List |
| #Set Global Variable ${ListfinishedONUs} |
| Create File ONU_Startup_Time.txt This file contains the startup times of all ONUs. |
| ${list_onus} Create List |
| Build ONU SN List ${list_onus} |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${all_onu_timeout} 50ms |
| ... Validate ONU Devices MIB State With Duration |
| ... ${onu_state} ${list_onus} ${timeStart} print2console=${print2console} |
| ... output_file=ONU_Startup_Time.txt |
| |
| Do Onu Port Check |
| [Documentation] Check that all the UNI ports show up in ONOS |
| Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${num_all_onus} BBSM ${timeout} |
| |
| Do Onu Etcd Data Check |
| [Documentation] Check Onu data stored in etcd |
| Validate Onu Data In Etcd defaultkvstoreprefix=${kvstoreprefix} |
| |
| Do Onu Flow Check |
| [Documentation] This keyword iterate all OLTs and performs Do Onu Flow Checks Per OLT |
| # Check and store vlan rules |
| ${firstvlanrules}= Run Keyword And Continue On Failure Validate Vlan Rules In Etcd |
| ... defaultkvstoreprefix=${kvstoreprefix} |
| FOR ${J} IN RANGE 0 ${num_olts} |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${onu_count}= Set Variable ${list_olts}[${J}][onucount] |
| ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS |
| ... ${olt_serial_number} |
| Set Global Variable ${of_id} |
| # Verify Default Meter in ONOS (valid only for ATT) |
| Do Onu Subscriber Add Per OLT ${of_id} ${olt_serial_number} ${onu_count} |
| END |
| FOR ${J} IN RANGE 0 ${num_olts} |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${onu_count}= Set Variable ${list_olts}[${J}][onucount] |
| ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS |
| ... ${olt_serial_number} |
| Set Global Variable ${of_id} |
| ${nni_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s |
| ... Get NNI Port in ONOS ${of_id} |
| Set Global Variable ${nni_port} |
| # Verify Default Meter in ONOS (valid only for ATT) |
| Do Onu Flow Check Per OLT ${of_id} ${nni_port} ${olt_serial_number} ${onu_count} |
| END |
| #log flows for verification |
| ${flowsresult}= Execute ONOS CLI Command use single connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT} flows -s |
| log ${flowsresult} |
| #check for previous state is kept (normally omci-flows-pushed) |
| Sleep 10s |
| Run Keyword And Continue On Failure Current State Test All Onus ${state2test} |
| ${secondvlanrules}= Run Keyword And Continue On Failure Validate Vlan Rules In Etcd nbofcookieslice=3 |
| ... prevvlanrules=${firstvlanrules} defaultkvstoreprefix=${kvstoreprefix} |
| FOR ${J} IN RANGE 0 ${num_olts} |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${onu_count}= Set Variable ${list_olts}[${J}][onucount] |
| ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS |
| ... ${olt_serial_number} |
| Set Global Variable ${of_id} |
| ${nni_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s |
| ... Get NNI Port in ONOS ${of_id} |
| Set Global Variable ${nni_port} |
| # Verify Default Meter in ONOS (valid only for ATT) |
| Do Onu Subscriber Remove Per OLT ${of_id} ${nni_port} ${olt_serial_number} ${onu_count} |
| END |
| #check for previous state is kept (normally omci-flows-pushed) |
| Sleep 10s |
| Run Keyword If ${print2console} Log \r\nStart State Test All Onus. console=yes |
| Run Keyword And Continue On Failure Current State Test All Onus ${state2test} |
| Run Keyword If ${print2console} Log \r\nFinished State Test All Onus. console=yes |
| Run Keyword And Continue On Failure Validate Vlan Rules In Etcd prevvlanrules=${firstvlanrules} |
| ... setvidequal=True defaultkvstoreprefix=${kvstoreprefix} |
| |
| Do Onu Subscriber Add Per OLT |
| [Documentation] Add Subscriber per OLT |
| [Arguments] ${of_id} ${olt_serial_number} ${num_onus} |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| Continue For Loop If "${olt_serial_number}"!="${src['olt']}" |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| ${onu_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s |
| ... Get ONU Port in ONOS ${src['onu']} ${of_id} |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2 |
| ... Execute ONOS CLI Command use single connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT} |
| ... volt-add-subscriber-access ${of_id} ${onu_port} |
| Run Keyword If ${print2console} Log \r\n[${I}] volt-add-subscriber-access ${of_id} ${onu_port}. |
| ... console=yes |
| END |
| |
| Do Onu Flow Check Per OLT |
| [Documentation] Checks all ONU flows show up in ONOS and Voltha |
| [Arguments] ${of_id} ${nni_port} ${olt_serial_number} ${num_onus} |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| Continue For Loop If "${olt_serial_number}"!="${src['olt']}" |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| ${onu_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s |
| ... Get ONU Port in ONOS ${src['onu']} ${of_id} |
| # Verify subscriber access flows are added for the ONU port |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s |
| ... Verify Subscriber Access Flows Added For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id} |
| ... ${onu_port} ${nni_port} ${src['c_tag']} ${src['s_tag']} |
| ${logoutput} Catenate \r\n[${I}] Verify Subscriber Access Flows Added For |
| ... ONU ${of_id} ${onu_port} ${src['c_tag']} ${src['s_tag']}. |
| Run Keyword If ${print2console} Log ${logoutput} console=yes |
| END |
| |
| Do Onu Subscriber Remove Per OLT |
| [Documentation] Removes per OLT subscribers in ONOS and Voltha |
| [Arguments] ${of_id} ${nni_port} ${olt_serial_number} ${num_onus} |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${dst}= Set Variable ${hosts.dst[${I}]} |
| Continue For Loop If "${olt_serial_number}"!="${src['olt']}" |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| ${onu_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s |
| ... Get ONU Port in ONOS ${src['onu']} ${of_id} |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2 |
| ... Execute ONOS CLI Command use single connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT} |
| ... volt-remove-subscriber-access ${of_id} ${onu_port} |
| Run Keyword If ${print2console} Log \r\n[${I}] volt-remove-subscriber-access ${of_id} ${onu_port}. |
| ... console=yes |
| END |
| |
| Do Check Tech Profile |
| [Documentation] This keyword checks the loaded TechProfile |
| ${namespace}= Set Variable default |
| ${podname}= Set Variable etcd |
| ${commandget} Catenate |
| ... /bin/sh -c 'ETCDCTL_API=3 etcdctl get --prefix service/voltha/technology_profiles/XGS-PON/64' |
| ${result}= Exec Pod In Kube ${namespace} ${podname} ${commandget} |
| ${num_gem_ports}= Set Variable 1 |
| ${num_gem_ports}= Set Variable If |
| ... "${techprofile}"=="default" 1 |
| ... "${techprofile}"=="1T4GEM" 4 |
| ... "${techprofile}"=="1T8GEM" 8 |
| ${length}= Get Length ${result} |
| @{resultList} Split String ${result} separator=, |
| ${num_of_count_matches}= Get Match Count ${resultList} "num_gem_ports": ${num_gem_ports} |
| ... whitespace_insensitive=True |
| # In case of default tech profile (1T1GEM) no file have to exist, so no entry will be found, but in case of a file is |
| # available corresponding entry has to be found! |
| ${num_of_expected_matches}= Set Variable If "${techprofile}"!="default" or ${length}>0 1 0 |
| Should Be Equal As Integers ${num_of_expected_matches} ${num_of_count_matches} |
| ... TechProfile (${TechProfile}) not loaded correctly: found(${num_of_count_matches}) expected(${num_of_expected_matches}) |
| |
| Do Disable Enable Onu Test |
| [Documentation] This keyword disables/enables all onus and checks the states. |
| [Arguments] ${state2check}=${state2test} ${checkstatebeforedisable}=True |
| ... ${state2checkafterdisable}=tech-profile-config-delete-success |
| Run Keyword If ${checkstatebeforedisable} Current State Test All Onus ${state2check} |
| Disable Onu Device |
| ${alternative_onu_reason}= Set Variable If |
| ... '${state2checkafterdisable}'=='tech-profile-config-delete-success' omci-flows-deleted |
| ... '${state2checkafterdisable}'=='omci-admin-lock' tech-profile-config-delete-success ${EMPTY} |
| ${alternativeonustates}= Create List ${alternative_onu_reason} |
| Current State Test All Onus ${state2checkafterdisable} alternativeonustate=${alternativeonustates} |
| Log Ports |
| #check no port is enabled in ONOS |
| Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} 0 BBSM |
| Enable Onu Device |
| Current State Test All Onus ${state2check} |
| Log Ports onlyenabled=True |
| #check that all the UNI ports show up in ONOS again |
| Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${num_all_onus} BBSM |
| |
| Do Power Off Power On Onu Device |
| [Documentation] This keyword power off/on all onus and checks the states. |
| Power Off ONU Device ${namespace} |
| Sleep 5s |
| ${alternativeonustates}= Create List omci-flows-deleted |
| Current State Test All Onus tech-profile-config-delete-success |
| ... ENABLED DISCOVERED UNREACHABLE alternativeonustate=${alternativeonustates} |
| Power On ONU Device ${namespace} |
| Current State Test All Onus ${state2test} |
| |
| Do Soft Reboot Onu Device |
| [Documentation] This keyword reboots softly all onus and checks the states. |
| ${device_list}= Set Variable ${EMPTY} |
| FOR ${I} IN RANGE 0 ${num_all_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| ${device_list}= Catenate ${device_list} ${onu_device_id} |
| END |
| Reboot ONU ${device_list} False |
| ${alternativeonustates}= Create List stopping-openomci |
| Current State Test All Onus omci-flows-deleted |
| ... ENABLED DISCOVERED UNREACHABLE alternativeonustate=${alternativeonustates} |
| Sleep 5s |
| Current State Test All Onus omci-flows-pushed |
| Do Onu Port Check |