| # Copyright 2020 - present Open Networking Foundation |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| |
| *** Settings *** |
| Documentation Test different Reconcile scenarios of ONU Go adapter with all three workflows ATT, DT and TT. |
| ... Test suite is dedicated for only one ONU! Run robot with bbsim-kind.yaml only! |
| ... Not for DT/TT workflow! |
| ... Hint: default timeout in BBSim to mimic OLT reboot is 60 seconds! |
| ... This behaviour of BBSim can be modified by 'oltRebootDelay: 60' in BBSim section of helm chart or |
| ... used values.yaml during 'voltha up'. |
| Suite Setup Setup Suite |
| Suite Teardown Teardown Suite |
| Test Setup Setup |
| Test Teardown Teardown |
| Library Collections |
| Library String |
| Library OperatingSystem |
| Library XML |
| Library RequestsLibrary |
| Library ../../libraries/DependencyLibrary.py |
| Resource ../../libraries/onos.robot |
| Resource ../../libraries/voltctl.robot |
| Resource ../../libraries/voltha.robot |
| Resource ../../libraries/utils.robot |
| Resource ../../libraries/k8s.robot |
| Resource ../../libraries/onu_utilities.robot |
| Resource ../../variables/variables.robot |
| |
| *** Variables *** |
| ${namespace} voltha |
| ${timeout} 60s |
| ${of_id} 0 |
| ${logical_id} 0 |
| ${has_dataplane} True |
| ${external_libs} True |
| ${teardown_device} True |
| ${scripts} ../../scripts |
| # Per-test logging on failure is turned off by default; set this variable to enable |
| ${container_log_dir} ${None} |
| # flag for first test, needed due default timeout in BBSim to mimic OLT reboot of 60 seconds |
| ${firsttest} True |
| # determines the environment workflow: DT, TT or ATT (default) |
| # example: -v workflow:DT |
| ${workflow} ATT |
| # KV Store Prefix |
| # example: -v kvstoreprefix:voltha_voltha |
| ${kvstoreprefix} voltha_voltha |
| # flag debugmode is used, if true timeout calculation various, can be passed via the command line too |
| # example: -v debugmode:True |
| ${debugmode} False |
| # logging flag to enable Collect Logs, can be passed via the command line too |
| # example: -v logging:True |
| ${logging} False |
| # if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline! |
| # example: -v pausebeforecleanup:True |
| ${pausebeforecleanup} False |
| # if True some outputs to console are done during running tests e.g. long duration flow test |
| # example: -v print2console:True |
| ${print2console} False |
| # if True (hard) kill will be used to restart onu adapter, else (soft) restart mechanism of k8s will be used |
| # example: -v usekill2restart:True |
| ${usekill2restart} False |
| # if True etcd check will be executed in test case teardown, if False etcd check will be executed in suite teardown |
| # example: -v etcdcheckintestteardown:False |
| ${etcdcheckintestteardown} True |
| ${data_dir} ../data |
| ${suppressaddsubscriber} True |
| |
| |
| *** Test Cases *** |
| Reconcile In Starting-OpenOmci |
| [Documentation] Validates the Reconcile in Starting-OpenOmci |
| ... Reconcile test during “starting-openomci” in AT&T-workflow: |
| ... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store) |
| ... - wait for device reason “starting-openomci” |
| ... - kill the open-onu-adapter-go |
| ... - wait for open-onu-adapter-go to restart |
| ... - perform sanity test include add subscriber |
| ... - delete ONU and MIB-template in KV-store |
| [Tags] functionalOnuGo ReconcileStartingOpenOmciOnuGo |
| [Setup] Run Keywords Start Logging ReconcileStartingOpenOmciOnuGo |
| ... AND Setup Test |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Do Reconcile In Determined State starting-openomci |
| [Teardown] Run Keywords Run Keyword If ${logging} Get Logical Id of OLT |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Teardown Test |
| ... AND Stop Logging ReconcileStartingOpenOmciOnuGo |
| |
| Reconcile In Initial-Mib-Downloaded |
| [Documentation] Validates the Reconcile in initial-mib-downloaded |
| ... Reconcile test during “initial-mib-downloaded” in AT&T-workflow: |
| ... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store) |
| ... - wait for device reason “initial-mib-downloaded” |
| ... - kill the open-onu-adapter-go |
| ... - wait for open-onu-adapter-go to restart |
| ... - perform sanity test include add subscriber |
| ... - delete ONU and MIB-template in KV-store |
| [Tags] functionalOnuGo ReconcileInitialMibDownloadedOnuGo |
| [Setup] Run Keywords Start Logging ReconcileInitialMibDownloadedOnuGo |
| ... AND Setup Test |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Do Reconcile In Determined State initial-mib-downloaded |
| [Teardown] Run Keywords Run Keyword If ${logging} Get Logical Id of OLT |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Teardown Test |
| ... AND Stop Logging ReconcileInitialMibDownloadedOnuGo |
| |
| Reconcile In Omci-Flows-Pushed |
| [Documentation] Validates the Reconcile in omci-flows-pushed |
| ... Former testcase: Reconcile Onu Device in Testsuite Voltha_ONUStateTest.robot |
| ... Reconcile test during “omci-flows-pushed” in AT&T-workflow: |
| ... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store) |
| ... - perform sanity test include add subscriber |
| ... - kill the open-onu-adapter-go |
| ... - wait for open-onu-adapter-go to restart |
| ... - perform sanity test suppress add subscriber |
| ... - disable onu device |
| ... - wait for device corresponding onu reason e.g. “tech-profile-config-delete-success” |
| ... - check UNI-ports disabled in ONOS |
| ... - enable onu device |
| ... - perform sanity test suppress add subscriber |
| ... - delete ONU and MIB-template in KV-store |
| [Tags] functionalOnuGo ReconcileOmciFlowsPushedOnuGo |
| [Setup] Run Keywords Start Logging ReconcileOmciFlowsPushedOnuGo |
| ... AND Setup Test |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Do Reconcile In Omci-Flows-Pushed |
| [Teardown] Run Keywords Run Keyword If ${logging} Get Logical Id of OLT |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Teardown Test |
| ... AND Stop Logging ReconcileOmciFlowsPushedOnuGo |
| |
| Reconcile For Disabled Onu Device |
| [Documentation] Validates the Reconcile for disabled Onu device |
| ... Reconcile test for disabled Onu device in AT&T-workflow: |
| ... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store) |
| ... - perform sanity test include add subscriber |
| ... - disable onu device |
| ... - wait for device corresponding onu reason e.g. “tech-profile-config-delete-success” |
| ... - check UNI-ports disabled in ONOS |
| ... - kill the open-onu-adapter-go |
| ... - wait for open-onu-adapter-go to restart |
| ... - check device reason is still the same before restart |
| ... - enable onu device |
| ... - perform sanity test suppress add subscriber |
| ... - delete ONU and MIB-template in KV-store |
| [Tags] functionalOnuGo ReconcileDisabledOnuDeviceOnuGo |
| [Setup] Run Keywords Start Logging ReconcileDisabledOnuDeviceOnuGo |
| ... AND Setup Test |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Do Reconcile For Disabled Onu Device |
| [Teardown] Run Keywords Run Keyword If ${logging} Get Logical Id of OLT |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Teardown Test |
| ... AND Stop Logging ReconcileDisabledOnuDeviceOnuGo |
| |
| *** Keywords *** |
| Setup Suite |
| [Documentation] Set up the test suite |
| ${LogInfo}= Catenate |
| ... \r\nPassed arguments: |
| ... debugmode:${debugmode}, logging:${logging}, pausebeforecleanup:${pausebeforecleanup}, |
| ... print2console:${print2console}, usekill2restart:${usekill2restart}, workflow:${workflow}, |
| ... kvstoreprefix:${kvstoreprefix} |
| Log ${LogInfo} console=yes |
| Common Test Suite Setup |
| # delete etcd MIB Template Data |
| Delete MIB Template Data |
| # delete etcd onu data |
| Delete ONU Go Adapter ETCD Data validate=True |
| |
| |
| Teardown Suite |
| [Documentation] Replaces the Suite Teardown in utils.robot. |
| ... Cleans up and checks all ONU ports disabled in ONOS. |
| ... Furthermore gives the possibility to pause the execution. |
| Run Keyword If ${pausebeforecleanup} Import Library Dialogs |
| Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up! |
| Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes |
| Run Keyword If ${teardown_device} Delete All Devices and Verify |
| Run Keyword If ${usekill2restart} Restart Pod ${namespace} open-onu |
| Run Keyword Unless ${etcdcheckintestteardown} Wait Until Keyword Succeeds ${timeout} 1s |
| ... Validate Onu Data In Etcd 0 ${kvstoreprefix} without_pm_data=False |
| Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} 0 BBSM ${timeout} |
| Close All ONOS SSH Connections |
| |
| Setup Test |
| [Documentation] Pre-test Setup |
| #test for empty device list |
| Test Empty Device List |
| Run Keyword If ${has_dataplane} Wait Until Keyword Succeeds 120s 10s Openolt is Up |
| ... ${olt_ssh_ip} ${olt_user} ${olt_pass} |
| Run Keyword If ${has_dataplane} Sleep 60s |
| #restart open-onu pod to reset crash loop back off mechansim of kubenetes |
| Run Keyword If "${firsttest}"=="False" and "${usekill2restart}"=="True" Restart Pod ${namespace} open-onu |
| Run Keyword If "${firsttest}"=="False" Sleep 35s |
| ${firsttest} Set Variable False |
| Set Suite Variable ${firsttest} |
| # Create a list of olt ids (logical and device_id) |
| ${olt_ids} Create List |
| FOR ${I} IN RANGE 0 ${num_olts} |
| #create/preprovision device |
| ${olt_device_id}= Run Keyword If "${list_olts}[${I}][type]" == "${None}" |
| ... Create Device ${list_olts}[${I}][ip] ${list_olts}[${I}][oltport] |
| ... ELSE Create Device ${list_olts}[${I}][ip] ${list_olts}[${I}][oltport] ${list_olts}[${I}][type] |
| ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| #validate olt states |
| Wait Until Keyword Succeeds ${timeout} 5s |
| ... Validate OLT Device PREPROVISIONED UNKNOWN UNKNOWN ${olt_device_id} by_dev_id=True |
| Sleep 5s |
| ${logical_id}= Get Logical Device ID From SN ${olt_serial_number} |
| ${olt} Create Dictionary device_id ${olt_device_id} logical_id ${logical_id} |
| ... of_id ${of_id} sn ${olt_serial_number} |
| Append To List ${olt_ids} ${olt} |
| END |
| Set Global Variable ${olt_ids} |
| |
| Teardown Test |
| [Documentation] Post-test Teardown |
| Run Keyword If ${pausebeforecleanup} Import Library Dialogs |
| Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up! |
| Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes |
| Run Keyword If ${teardown_device} Delete All Devices and Verify |
| # delete etcd MIB Template Data |
| Delete MIB Template Data |
| # check etcd data are empty |
| Run Keyword If ${etcdcheckintestteardown} Wait Until Keyword Succeeds ${timeout} 1s |
| ... Validate Onu Data In Etcd 0 ${kvstoreprefix} without_pm_data=False |
| Sleep 5s |
| |
| Do Reconcile In Determined State |
| [Documentation] This keyword reconciles ONU device when passed reason is reached and |
| ... check the state afterwards. |
| ... Following steps will be executed: |
| ... - enable OLT device |
| ... - wait for passed openonu reason |
| ... - restart openonu adaptor |
| ... - perform sanity test include add subscriber |
| [Arguments] ${expected_onu_reason} |
| ${admin_state} ${oper_status} ${connect_status} ${onu_state_nb} ${onu_state}= Map State |
| ... ${expected_onu_reason} |
| Should Be True ${onu_state_nb}<=5 |
| ... Wrong expected onu reason ${expected_onu_reason}, must be lower than 'omci-flows-pushed'! |
| FOR ${I} IN RANGE 0 ${num_olts} |
| #get olt serial number |
| ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| #validate olt states |
| ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number} |
| Enable Device ${olt_device_id} |
| END |
| Current State Test All Onus ${expected_onu_reason} |
| Run Keyword If ${usekill2restart} Kill And Check Onu Adaptor ${namespace} |
| ... ELSE Restart And Check Onu Adaptor ${namespace} |
| Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT |
| ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT |
| ... ELSE Perform Sanity Test |
| |
| Do Reconcile For Disabled Onu Device |
| [Documentation] This keyword reconciles ONU device for a disabled onu device and |
| ... check the state afterwards. |
| ... Following steps will be executed: |
| ... - enable OLT device |
| ... - perform sanity test include add subscriber |
| ... - disable onu device |
| ... - wait for corresponding openonu reason |
| ... - check UNI-ports disabled in ONOS |
| ... - restart openonu adaptor |
| ... - check openonu adaptor is ready again |
| ... - check device reason is still before restart |
| ... - enable onu device |
| ... - perform sanity test suppress add subscriber |
| FOR ${I} IN RANGE 0 ${num_olts} |
| #get olt serial number |
| ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| #validate olt states |
| ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number} |
| Enable Device ${olt_device_id} |
| END |
| Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT |
| ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT |
| ... ELSE Perform Sanity Test |
| Disable Onu Device |
| ${alternativeonustates}= Create List omci-flows-deleted |
| Run Keyword If "${workflow}"=="DT" Current State Test All Onus omci-admin-lock |
| ... ELSE IF "${workflow}"=="TT" Current State Test All Onus omci-admin-lock |
| ... ELSE Current State Test All Onus omci-admin-lock alternativeonustate=${alternativeonustates} |
| Run Keyword If ${usekill2restart} Kill And Check Onu Adaptor ${namespace} |
| ... ELSE Restart And Check Onu Adaptor ${namespace} |
| Run Keyword If "${workflow}"=="DT" Current State Test All Onus omci-admin-lock |
| ... ELSE IF "${workflow}"=="TT" Current State Test All Onus omci-admin-lock |
| ... ELSE Current State Test All Onus omci-admin-lock alternativeonustate=${alternativeonustates} |
| Wait for all ONU Ports in ONOS Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} |
| Enable Onu Device |
| Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT ${suppressaddsubscriber} |
| ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT ${suppressaddsubscriber} |
| ... ELSE Perform Sanity Test ${suppressaddsubscriber} |
| |
| Do Reconcile In Omci-Flows-Pushed |
| [Documentation] This keyword reconciles ONU device in omci-flows-pushed and check the state afterwards. |
| ... Reconcile test during “omci-flows-pushed” in AT&T-workflow: |
| ... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store) |
| ... - perform sanity test include add subscriber |
| ... - kill the open-onu-adapter-go |
| ... - wait for open-onu-adapter-go to restart |
| ... - perform sanity test suppress add subscriber |
| ... - disable onu device |
| ... - wait for corresponding device reason |
| ... - check UNI-ports disabled in ONOS |
| ... - enable onu device |
| ... - perform sanity test supress add subscriber |
| FOR ${I} IN RANGE 0 ${num_olts} |
| #get olt serial number |
| ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| #validate olt states |
| ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number} |
| Enable Device ${olt_device_id} |
| END |
| Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT |
| ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT |
| ... ELSE Perform Sanity Test |
| Run Keyword If ${usekill2restart} Kill And Check Onu Adaptor ${namespace} |
| ... ELSE Restart And Check Onu Adaptor ${namespace} |
| Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT ${suppressaddsubscriber} |
| ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT ${suppressaddsubscriber} |
| ... ELSE Perform Sanity Test ${suppressaddsubscriber} |
| Disable Onu Device |
| ${alternativeonustates}= Create List omci-flows-deleted |
| Run Keyword If "${workflow}"=="DT" Current State Test All Onus omci-admin-lock |
| ... ELSE IF "${workflow}"=="TT" Current State Test All Onus omci-admin-lock |
| ... ELSE Current State Test All Onus omci-admin-lock alternativeonustate=${alternativeonustates} |
| Wait for all ONU Ports in ONOS Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} |
| Enable Onu Device |
| Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT ${suppressaddsubscriber} |
| ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT ${suppressaddsubscriber} |
| ... ELSE Perform Sanity Test ${suppressaddsubscriber} |