blob: 14c7964d073681d8e7d6b2ad4d4d54f76d633913 [file] [log] [blame]
# Copyright 2020 - present Open Networking Foundation
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
*** Settings ***
Documentation Test different Reconcile scenarios of ONU Go adapter with all three workflows ATT, DT and TT.
... Test suite is dedicated for only one ONU! Run robot with bbsim-kind.yaml only!
... Not for DT/TT workflow!
... Hint: default timeout in BBSim to mimic OLT reboot is 60 seconds!
... This behaviour of BBSim can be modified by 'oltRebootDelay: 60' in BBSim section of helm chart or
... used values.yaml during 'voltha up'.
Suite Setup Setup Suite
Suite Teardown Teardown Suite
Test Setup Setup
Test Teardown Teardown
Library Collections
Library String
Library OperatingSystem
Library XML
Library RequestsLibrary
Library ../../libraries/DependencyLibrary.py
Resource ../../libraries/onos.robot
Resource ../../libraries/voltctl.robot
Resource ../../libraries/voltha.robot
Resource ../../libraries/utils.robot
Resource ../../libraries/k8s.robot
Resource ../../libraries/onu_utilities.robot
Resource ../../variables/variables.robot
*** Variables ***
${namespace} voltha
${timeout} 60s
${of_id} 0
${logical_id} 0
${has_dataplane} True
${external_libs} True
${teardown_device} True
${scripts} ../../scripts
# Per-test logging on failure is turned off by default; set this variable to enable
${container_log_dir} ${None}
# flag for first test, needed due default timeout in BBSim to mimic OLT reboot of 60 seconds
${firsttest} True
# determines the environment workflow: DT, TT or ATT (default)
# example: -v workflow:DT
${workflow} ATT
# KV Store Prefix
# example: -v kvstoreprefix:voltha_voltha
${kvstoreprefix} voltha_voltha
# flag debugmode is used, if true timeout calculation various, can be passed via the command line too
# example: -v debugmode:True
${debugmode} False
# logging flag to enable Collect Logs, can be passed via the command line too
# example: -v logging:True
${logging} False
# if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline!
# example: -v pausebeforecleanup:True
${pausebeforecleanup} False
# if True some outputs to console are done during running tests e.g. long duration flow test
# example: -v print2console:True
${print2console} False
# if True (hard) kill will be used to restart onu adapter, else (soft) restart mechanism of k8s will be used
# example: -v usekill2restart:True
${usekill2restart} False
# if True etcd check will be executed in test case teardown, if False etcd check will be executed in suite teardown
# example: -v etcdcheckintestteardown:False
${etcdcheckintestteardown} True
${data_dir} ../data
${suppressaddsubscriber} True
*** Test Cases ***
Reconcile In Starting-OpenOmci
[Documentation] Validates the Reconcile in Starting-OpenOmci
... Reconcile test during starting-openomci in AT&T-workflow:
... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store)
... - wait for device reason starting-openomci
... - kill the open-onu-adapter-go
... - wait for open-onu-adapter-go to restart
... - perform sanity test include add subscriber
... - delete ONU and MIB-template in KV-store
[Tags] functionalOnuGo ReconcileStartingOpenOmciOnuGo
[Setup] Run Keywords Start Logging ReconcileStartingOpenOmciOnuGo
... AND Setup Test
Run Keyword If ${has_dataplane} Clean Up Linux
Do Reconcile In Determined State starting-openomci
[Teardown] Run Keywords Run Keyword If ${logging} Get Logical Id of OLT
... AND Run Keyword If ${logging} Collect Logs
... AND Teardown Test
... AND Stop Logging ReconcileStartingOpenOmciOnuGo
Reconcile In Initial-Mib-Downloaded
[Documentation] Validates the Reconcile in initial-mib-downloaded
... Reconcile test during initial-mib-downloaded in AT&T-workflow:
... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store)
... - wait for device reason initial-mib-downloaded
... - kill the open-onu-adapter-go
... - wait for open-onu-adapter-go to restart
... - perform sanity test include add subscriber
... - delete ONU and MIB-template in KV-store
[Tags] functionalOnuGo ReconcileInitialMibDownloadedOnuGo
[Setup] Run Keywords Start Logging ReconcileInitialMibDownloadedOnuGo
... AND Setup Test
Run Keyword If ${has_dataplane} Clean Up Linux
Do Reconcile In Determined State initial-mib-downloaded
[Teardown] Run Keywords Run Keyword If ${logging} Get Logical Id of OLT
... AND Run Keyword If ${logging} Collect Logs
... AND Teardown Test
... AND Stop Logging ReconcileInitialMibDownloadedOnuGo
Reconcile In Omci-Flows-Pushed
[Documentation] Validates the Reconcile in omci-flows-pushed
... Former testcase: Reconcile Onu Device in Testsuite Voltha_ONUStateTest.robot
... Reconcile test during omci-flows-pushed in AT&T-workflow:
... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store)
... - perform sanity test include add subscriber
... - kill the open-onu-adapter-go
... - wait for open-onu-adapter-go to restart
... - perform sanity test suppress add subscriber
... - disable onu device
... - wait for device corresponding onu reason e.g. tech-profile-config-delete-success
... - check UNI-ports disabled in ONOS
... - enable onu device
... - perform sanity test suppress add subscriber
... - delete ONU and MIB-template in KV-store
[Tags] functionalOnuGo ReconcileOmciFlowsPushedOnuGo
[Setup] Run Keywords Start Logging ReconcileOmciFlowsPushedOnuGo
... AND Setup Test
Run Keyword If ${has_dataplane} Clean Up Linux
Do Reconcile In Omci-Flows-Pushed
[Teardown] Run Keywords Run Keyword If ${logging} Get Logical Id of OLT
... AND Run Keyword If ${logging} Collect Logs
... AND Teardown Test
... AND Stop Logging ReconcileOmciFlowsPushedOnuGo
Reconcile For Disabled Onu Device
[Documentation] Validates the Reconcile for disabled Onu device
... Reconcile test for disabled Onu device in AT&T-workflow:
... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store)
... - perform sanity test include add subscriber
... - disable onu device
... - wait for device corresponding onu reason e.g. tech-profile-config-delete-success
... - check UNI-ports disabled in ONOS
... - kill the open-onu-adapter-go
... - wait for open-onu-adapter-go to restart
... - check device reason is still the same before restart
... - enable onu device
... - perform sanity test suppress add subscriber
... - delete ONU and MIB-template in KV-store
[Tags] functionalOnuGo ReconcileDisabledOnuDeviceOnuGo
[Setup] Run Keywords Start Logging ReconcileDisabledOnuDeviceOnuGo
... AND Setup Test
Run Keyword If ${has_dataplane} Clean Up Linux
Do Reconcile For Disabled Onu Device
[Teardown] Run Keywords Run Keyword If ${logging} Get Logical Id of OLT
... AND Run Keyword If ${logging} Collect Logs
... AND Teardown Test
... AND Stop Logging ReconcileDisabledOnuDeviceOnuGo
*** Keywords ***
Setup Suite
[Documentation] Set up the test suite
${LogInfo}= Catenate
... \r\nPassed arguments:
... debugmode:${debugmode}, logging:${logging}, pausebeforecleanup:${pausebeforecleanup},
... print2console:${print2console}, usekill2restart:${usekill2restart}, workflow:${workflow},
... kvstoreprefix:${kvstoreprefix}
Log ${LogInfo} console=yes
Common Test Suite Setup
# delete etcd MIB Template Data
Delete MIB Template Data
# delete etcd onu data
Delete ONU Go Adapter ETCD Data validate=True
Teardown Suite
[Documentation] Replaces the Suite Teardown in utils.robot.
... Cleans up and checks all ONU ports disabled in ONOS.
... Furthermore gives the possibility to pause the execution.
Run Keyword If ${pausebeforecleanup} Import Library Dialogs
Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up!
Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes
Run Keyword If ${teardown_device} Delete All Devices and Verify
Run Keyword If ${usekill2restart} Restart Pod ${namespace} open-onu
Run Keyword Unless ${etcdcheckintestteardown} Wait Until Keyword Succeeds ${timeout} 1s
... Validate Onu Data In Etcd 0 ${kvstoreprefix} without_pm_data=False
Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} 0 BBSM ${timeout}
Close All ONOS SSH Connections
Setup Test
[Documentation] Pre-test Setup
#test for empty device list
Test Empty Device List
Run Keyword If ${has_dataplane} Wait Until Keyword Succeeds 120s 10s Openolt is Up
... ${olt_ssh_ip} ${olt_user} ${olt_pass}
Run Keyword If ${has_dataplane} Sleep 60s
#restart open-onu pod to reset crash loop back off mechansim of kubenetes
Run Keyword If "${firsttest}"=="False" and "${usekill2restart}"=="True" Restart Pod ${namespace} open-onu
Run Keyword If "${firsttest}"=="False" Sleep 35s
${firsttest} Set Variable False
Set Suite Variable ${firsttest}
# Create a list of olt ids (logical and device_id)
${olt_ids} Create List
FOR ${I} IN RANGE 0 ${num_olts}
#create/preprovision device
${olt_device_id}= Run Keyword If "${list_olts}[${I}][type]" == "${None}"
... Create Device ${list_olts}[${I}][ip] ${list_olts}[${I}][oltport]
... ELSE Create Device ${list_olts}[${I}][ip] ${list_olts}[${I}][oltport] ${list_olts}[${I}][type]
${olt_serial_number}= Set Variable ${list_olts}[${I}][sn]
#validate olt states
Wait Until Keyword Succeeds ${timeout} 5s
... Validate OLT Device PREPROVISIONED UNKNOWN UNKNOWN ${olt_device_id} by_dev_id=True
Sleep 5s
${logical_id}= Get Logical Device ID From SN ${olt_serial_number}
${olt} Create Dictionary device_id ${olt_device_id} logical_id ${logical_id}
... of_id ${of_id} sn ${olt_serial_number}
Append To List ${olt_ids} ${olt}
END
Set Global Variable ${olt_ids}
Teardown Test
[Documentation] Post-test Teardown
Run Keyword If ${pausebeforecleanup} Import Library Dialogs
Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up!
Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes
Run Keyword If ${teardown_device} Delete All Devices and Verify
# delete etcd MIB Template Data
Delete MIB Template Data
# check etcd data are empty
Run Keyword If ${etcdcheckintestteardown} Wait Until Keyword Succeeds ${timeout} 1s
... Validate Onu Data In Etcd 0 ${kvstoreprefix} without_pm_data=False
Sleep 5s
Do Reconcile In Determined State
[Documentation] This keyword reconciles ONU device when passed reason is reached and
... check the state afterwards.
... Following steps will be executed:
... - enable OLT device
... - wait for passed openonu reason
... - restart openonu adaptor
... - perform sanity test include add subscriber
[Arguments] ${expected_onu_reason}
${admin_state} ${oper_status} ${connect_status} ${onu_state_nb} ${onu_state}= Map State
... ${expected_onu_reason}
Should Be True ${onu_state_nb}<=5
... Wrong expected onu reason ${expected_onu_reason}, must be lower than 'omci-flows-pushed'!
FOR ${I} IN RANGE 0 ${num_olts}
#get olt serial number
${olt_serial_number}= Set Variable ${list_olts}[${I}][sn]
#validate olt states
${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
Enable Device ${olt_device_id}
END
Current State Test All Onus ${expected_onu_reason}
Run Keyword If ${usekill2restart} Kill And Check Onu Adaptor ${namespace}
... ELSE Restart And Check Onu Adaptor ${namespace}
Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT
... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT
... ELSE Perform Sanity Test
Do Reconcile For Disabled Onu Device
[Documentation] This keyword reconciles ONU device for a disabled onu device and
... check the state afterwards.
... Following steps will be executed:
... - enable OLT device
... - perform sanity test include add subscriber
... - disable onu device
... - wait for corresponding openonu reason
... - check UNI-ports disabled in ONOS
... - restart openonu adaptor
... - check openonu adaptor is ready again
... - check device reason is still before restart
... - enable onu device
... - perform sanity test suppress add subscriber
FOR ${I} IN RANGE 0 ${num_olts}
#get olt serial number
${olt_serial_number}= Set Variable ${list_olts}[${I}][sn]
#validate olt states
${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
Enable Device ${olt_device_id}
END
Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT
... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT
... ELSE Perform Sanity Test
Disable Onu Device
${alternativeonustates}= Create List omci-flows-deleted
Run Keyword If "${workflow}"=="DT" Current State Test All Onus omci-admin-lock
... ELSE IF "${workflow}"=="TT" Current State Test All Onus omci-admin-lock
... ELSE Current State Test All Onus omci-admin-lock alternativeonustate=${alternativeonustates}
Run Keyword If ${usekill2restart} Kill And Check Onu Adaptor ${namespace}
... ELSE Restart And Check Onu Adaptor ${namespace}
Run Keyword If "${workflow}"=="DT" Current State Test All Onus omci-admin-lock
... ELSE IF "${workflow}"=="TT" Current State Test All Onus omci-admin-lock
... ELSE Current State Test All Onus omci-admin-lock alternativeonustate=${alternativeonustates}
Wait for all ONU Ports in ONOS Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
Enable Onu Device
Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT ${suppressaddsubscriber}
... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT ${suppressaddsubscriber}
... ELSE Perform Sanity Test ${suppressaddsubscriber}
Do Reconcile In Omci-Flows-Pushed
[Documentation] This keyword reconciles ONU device in omci-flows-pushed and check the state afterwards.
... Reconcile test during omci-flows-pushed in AT&T-workflow:
... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store)
... - perform sanity test include add subscriber
... - kill the open-onu-adapter-go
... - wait for open-onu-adapter-go to restart
... - perform sanity test suppress add subscriber
... - disable onu device
... - wait for corresponding device reason
... - check UNI-ports disabled in ONOS
... - enable onu device
... - perform sanity test supress add subscriber
FOR ${I} IN RANGE 0 ${num_olts}
#get olt serial number
${olt_serial_number}= Set Variable ${list_olts}[${I}][sn]
#validate olt states
${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
Enable Device ${olt_device_id}
END
Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT
... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT
... ELSE Perform Sanity Test
Run Keyword If ${usekill2restart} Kill And Check Onu Adaptor ${namespace}
... ELSE Restart And Check Onu Adaptor ${namespace}
Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT ${suppressaddsubscriber}
... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT ${suppressaddsubscriber}
... ELSE Perform Sanity Test ${suppressaddsubscriber}
Disable Onu Device
${alternativeonustates}= Create List omci-flows-deleted
Run Keyword If "${workflow}"=="DT" Current State Test All Onus omci-admin-lock
... ELSE IF "${workflow}"=="TT" Current State Test All Onus omci-admin-lock
... ELSE Current State Test All Onus omci-admin-lock alternativeonustate=${alternativeonustates}
Wait for all ONU Ports in ONOS Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
Enable Onu Device
Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT ${suppressaddsubscriber}
... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT ${suppressaddsubscriber}
... ELSE Perform Sanity Test ${suppressaddsubscriber}