| # Copyright 2022-2024 Open Networking Foundation (ONF) and the ONF Contributors |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| |
| *** Settings *** |
| Documentation Test of open ONU error cases |
| ... The test suite validates special error scenarios of openonu_go_adapter |
| ... -- power off during mib download |
| ... -- power of during flow configuration |
| ... -- onu capabilities against configuration requirements priority queues |
| ... -- onu capabilities against configuration requirements tconts |
| ... see also VOL-4796 |
| ... In case of kafka pod runs in k8s cluster - kafka has to deploy with following EXTRA_HELM_FLAGS |
| ... --set externalAccess.enabled=true, |
| ... --set externalAccess.service.type=NodePort, |
| ... --set externalAccess.service.nodePorts[0]=${KAFKA_PORT}, |
| ... --set externalAccess.service.domain=${KAFKA_IP} |
| ... with e.g. service.domain=10.0.02.15 or 127.0.0.1 and service.nodePorts[0]=30201! |
| ... For voltha-infra prefix kafka. is needed e.g.: --set kafka.externalAccess.enabled=true |
| Suite Setup Setup Suite |
| Suite Teardown Teardown Suite |
| Test Setup Setup |
| Test Teardown Teardown |
| Library Collections |
| Library String |
| Library OperatingSystem |
| Library XML |
| Library RequestsLibrary |
| Library ../../libraries/DependencyLibrary.py |
| Resource ../../libraries/onos.robot |
| Resource ../../libraries/voltctl.robot |
| Resource ../../libraries/voltha.robot |
| Resource ../../libraries/utils.robot |
| Resource ../../libraries/k8s.robot |
| Resource ../../libraries/onu_utilities.robot |
| Resource ../../libraries/bbsim.robot |
| Resource ../../variables/variables.robot |
| |
| Library kafka_robot.KafkaClient log_level=DEBUG WITH NAME kafka |
| Library grpc_robot.VolthaTools WITH NAME volthatools |
| |
| |
| *** Variables *** |
| ${NAMESPACE} voltha |
| ${INFRA_NAMESPACE} default |
| ${timeout} 60s |
| ${of_id} 0 |
| ${logical_id} 0 |
| ${has_dataplane} True |
| ${external_libs} True |
| ${teardown_device} True |
| ${scripts} ../../scripts |
| # Per-test logging on failure is turned off by default; set this variable to enable |
| ${container_log_dir} ${None} |
| |
| # logging flag to enable Collect Logs, can be passed via the command line too |
| # example: -v logging:True |
| ${logging} False |
| # if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline! |
| # example: -v pausebeforecleanup:True |
| ${pausebeforecleanup} False |
| # flag for first test, needed due default timeout in BBSim to mimic OLT reboot of 60 seconds |
| ${firsttest} True |
| # determines the environment workflow: DT, TT or ATT (default) |
| # example: -v workflow:DT |
| ${workflow} ATT |
| # KV Store Prefix |
| # example: -v kvstoreprefix:voltha/voltha_voltha |
| ${kvstoreprefix} voltha/voltha_voltha |
| # when voltha is running in k8s port forwarding is needed |
| # example: -v PORT_FORWARDING:False |
| ${PORT_FORWARDING} True |
| # kafka ip e.g. ip of master host where k8s is running |
| # example: -v KAFKA_IP:10.0.2.15 |
| ${KAFKA_IP} 127.0.0.1 |
| # kafka port: port of kafka nodeport |
| # example: -v KAFKA_PORT:30201 |
| ${KAFKA_PORT} 30201 |
| # kafka service port: service port of kafka nodeport |
| # example: -v KAFKA_SVC_PORT:9094 |
| ${KAFKA_SVC_PORT} 9094 |
| # onu MIB audit interval |
| # example: -v ONU_MIB_AUDIT_INTERVAL:50s |
| ${ONU_MIB_AUDIT_INTERVAL} 60s |
| # MDS mitsmatches per ONU |
| # example: -v MDS_MISMATCHES_PER_ONU:2 |
| ${MDS_MISMATCHES_PER_ONU} 3 |
| # if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline! |
| # example: -v pausebeforecleanup:True |
| ${pausebeforecleanup} False |
| # if True some outputs to console are done during running tests e.g. long duration flow test |
| # example: -v print2console:True |
| ${print2console} False |
| ${suppressaddsubscriber} True |
| ${data_dir} ../data |
| |
| # flag to choose the subscriber provisioning command type in ONOS |
| # TT often provision a single services for a subscriber (eg: hsia, voip, ...) one after the other. |
| # if set to True, command used is "volt-add-subscriber-unitag" |
| # if set to False, comand used is "volt-add-subscriber-access" |
| ${unitag_sub} False |
| |
| *** Test Cases *** |
| Verify Power Off During MIB Downloading |
| [Documentation] Validates the ONU Go adapter regarding robustness in case of ONU power-off during MIB downloading |
| [Tags] functional PowerOffWhileMibDownload |
| [Setup] Run Keywords Start Logging PowerOffWhileMibDownload |
| ... AND Setup Test |
| FOR ${I} IN RANGE 0 ${num_olts} |
| #get olt serial number |
| ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| #validate olt states |
| ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number} |
| Enable Device ${olt_device_id} |
| END |
| Current State Test All Onus starting-openomci |
| Power Off ONU Device ${namespace} |
| Current State Test All Onus stopping-openomci |
| Power On ONU Device ${namespace} |
| Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT |
| ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT |
| ... ELSE Perform Sanity Test |
| [Teardown] Run Keywords Printout ONU Serial Number and Device Id print2console=${print2console} |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Delete All Devices and Verify |
| ... AND Delete MIB Template Data ${INFRA_NAMESPACE} |
| ... AND Stop Logging PowerOffWhileMibDownload |
| |
| Verify Power Off During Flow Configuration |
| [Documentation] Validates the ONU Go adapter regarding robustness in case of ONU power-off during flow configuration |
| ... see VOL-4828 |
| [Tags] functional PowerOffWhileFlowConfig |
| [Setup] Run Keywords Start Logging PowerOffWhileFlowConfig |
| ... AND Setup Test |
| FOR ${I} IN RANGE 0 ${num_olts} |
| #get olt serial number |
| ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| #validate olt states |
| ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number} |
| Enable Device ${olt_device_id} |
| END |
| ${state2test}= Set Variable If |
| ... "${workflow}"=="DT" initial-mib-downloaded |
| ... "${workflow}"=="TT" initial-mib-downloaded |
| ... "${workflow}"=="ATT" omci-flows-pushed |
| ... initial-mib-downloaded |
| Current State Test All Onus ${state2test} |
| FOR ${J} IN RANGE 0 ${num_olts} |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS |
| ... ${olt_serial_number} |
| Do Onu Subscriber Add Per OLT ${of_id} ${olt_serial_number} ${print2console} |
| END |
| Power Off ONU Device ${namespace} |
| Current State Test All Onus stopping-openomci |
| Power On ONU Device ${namespace} |
| Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT ${suppressaddsubscriber} |
| ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT ${suppressaddsubscriber} |
| ... ELSE Perform Sanity Test ${suppressaddsubscriber} |
| [Teardown] Run Keywords Printout ONU Serial Number and Device Id print2console=${print2console} |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Delete All Devices and Verify |
| ... AND Delete MIB Template Data ${INFRA_NAMESPACE} |
| ... AND Stop Logging PowerOffWhileFlowConfig |
| |
| Verify ONU capabilities against configuration requirements Priority Queues |
| [Documentation] Validates the ONU capabilities against configuration requirements regarding number of priority queues. |
| ... Require more priority queues than ONU capabilities. Check for correct reason/state of ONU and kafka |
| ... message. |
| ... see VOL-4827 |
| [Tags] functional ONUCapabilitiesVsConfigReqPrioQueues |
| [Setup] Run Keywords Start Logging ONUCapabilitiesVsConfigReqPrioQueues |
| ... AND Set Tech Profile 1T65GEM-error-case-priority-queues |
| ... AND Setup Test |
| kafka.Records Clear |
| FOR ${I} IN RANGE 0 ${num_olts} |
| #get olt serial number |
| ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| #validate olt states |
| ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number} |
| Enable Device ${olt_device_id} |
| END |
| ${state2test}= Set Variable If |
| ... "${workflow}"=="DT" initial-mib-downloaded |
| ... "${workflow}"=="TT" initial-mib-downloaded |
| ... "${workflow}"=="ATT" stopping-openomci |
| ... initial-mib-downloaded |
| Current State Test All Onus ${state2test} |
| FOR ${J} IN RANGE 0 ${num_olts} |
| #in case of ATT no flows have to configured. leave loop |
| Exit For Loop If "${workflow}"=="ATT" |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS |
| ... ${olt_serial_number} |
| Do Onu Subscriber Add Per OLT ${of_id} ${olt_serial_number} ${print2console} |
| END |
| ${alternativeonustates}= Create List omci-flows-deleted |
| Current State Test All Onus stopping-openomci alternativeonustate=${alternativeonustates} |
| ${list_onu_device_id} Create List |
| Build ONU Device Id List ${list_onu_device_id} |
| ${event}= Set Variable ONU_CONFIG_FAILURE_MISSING_US_PRIORITY_QUEUE |
| Wait Until Keyword Succeeds ${timeout} 5s Validate Events All ONUs ${list_onu_device_id} ${event} |
| [Teardown] Run Keywords Printout ONU Serial Number and Device Id print2console=${print2console} |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Run Keyword If ${pausebeforecleanup} Import Library Dialogs |
| ... AND Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up! |
| ... AND Set Suite Variable ${TechProfile} ${EMPTY} |
| ... AND Remove Tech Profile ${INFRA_NAMESPACE} |
| ... AND Delete All Devices and Verify |
| ... AND Get ONU Go Adapter ETCD Data ${INFRA_NAMESPACE} ${kvstoreprefix} |
| ... AND Delete MIB Template Data ${INFRA_NAMESPACE} |
| ... AND Stop Logging ONUCapabilitiesVsConfigReqPrioQueues |
| |
| Verify ONU capabilities against configuration requirements TConts |
| [Documentation] Validates the ONU capabilities against configuration requirements regarding number of tconts. |
| ... Require more tconts than ONU capabilities. Check for correct reason/state of ONU and kafka message |
| ... VOL-4826 |
| ... Hint: Run this test case using bbsim-kind-multi-uni-tt.yaml! |
| [Tags] functionalMultiUni ONUCapabilitiesVsConfigReqTConts |
| [Setup] Run Keywords Start Logging ONUCapabilitiesVsConfigReqTConts |
| ... AND Set Tech Profile 1T1GEM-multi-instances ${INFRA_NAMESPACE} 64 |
| ... AND Set Tech Profile 1T1GEM-multi-instances ${INFRA_NAMESPACE} 65 |
| ... AND Set Tech Profile 1T1GEM-multi-instances ${INFRA_NAMESPACE} 66 |
| ... AND Setup Test |
| kafka.Records Clear |
| FOR ${I} IN RANGE 0 ${num_olts} |
| #get olt serial number |
| ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| #validate olt states |
| ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number} |
| Enable Device ${olt_device_id} |
| END |
| ${state2test}= Set Variable If |
| ... "${workflow}"=="DT" initial-mib-downloaded |
| ... "${workflow}"=="TT" initial-mib-downloaded |
| ... "${workflow}"=="ATT" omci-flows-pushed |
| ... initial-mib-downloaded |
| Current State Test All Onus ${state2test} |
| FOR ${J} IN RANGE 0 ${num_olts} |
| ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS |
| ... ${olt_serial_number} |
| Do Onu Subscriber Add Per OLT ${of_id} ${olt_serial_number} ${print2console} |
| END |
| ${alternativeonustates}= Create List omci-flows-deleted |
| Current State Test All Onus stopping-openomci alternativeonustate=${alternativeonustates} |
| ${list_onu_device_id} Create List |
| Build ONU Device Id List ${list_onu_device_id} |
| ${list_onu_device_id} Create List |
| Build ONU Device Id List ${list_onu_device_id} |
| ${event}= Set Variable ONU_CONFIG_FAILURE_MISSING_TCONT |
| Wait Until Keyword Succeeds ${timeout} 5s Validate Events All ONUs ${list_onu_device_id} ${event} |
| [Teardown] Run Keywords Printout ONU Serial Number and Device Id print2console=${print2console} |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Run Keyword If ${pausebeforecleanup} Import Library Dialogs |
| ... AND Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up! |
| ... AND Set Suite Variable ${TechProfile} ${EMPTY} |
| ... AND Remove Tech Profile ${INFRA_NAMESPACE} |
| ... AND Remove Tech Profile ${INFRA_NAMESPACE} 65 |
| ... AND Remove Tech Profile ${INFRA_NAMESPACE} 66 |
| ... AND Delete All Devices and Verify |
| ... AND Get ONU Go Adapter ETCD Data ${INFRA_NAMESPACE} ${kvstoreprefix} |
| ... AND Delete MIB Template Data ${INFRA_NAMESPACE} |
| ... AND Stop Logging ONUCapabilitiesVsConfigReqTConts |
| |
| *** Keywords *** |
| Setup Suite |
| [Documentation] Set up the test suite |
| Start Logging Setup or Teardown Setup-${SUITE NAME} |
| Common Test Suite Setup |
| ${switch_type}= Get Variable Value ${web_power_switch.type} |
| Run Keyword If "${switch_type}"!="" Set Global Variable ${powerswitch_type} ${switch_type} |
| # set ${kafka} depending on environment in case of port-forward is needed |
| ${rc} ${kafka}= Run Keyword If ${PORT_FORWARDING} Run and Return Rc and Output |
| ... kubectl get svc -n ${INFRA_NAMESPACE} | grep kafka-0-external | awk '{print $1}' |
| Run Keyword If ${PORT_FORWARDING} Should Not Be Empty ${kafka} Service kafka-0-external not found |
| # start port forwarding if needed (when voltha runs in k8s) |
| ${portFwdHandle} = Run Keyword If ${PORT_FORWARDING} Start Process |
| ... kubectl port-forward --address 0.0.0.0 --namespace default svc/${kafka} ${KAFKA_PORT}:${KAFKA_SVC_PORT} & |
| ... shell=true |
| Set Suite Variable ${portFwdHandle} |
| Sleep 5s |
| # open connection to read kafka bus |
| Wait Until Keyword Succeeds 3x 5s |
| ... kafka.Connection Open ${KAFKA_IP} ${KAFKA_PORT} voltha.events timestamp_from=0 |
| # delete etcd MIB Template Data |
| Delete MIB Template Data ${INFRA_NAMESPACE} |
| # delete etcd onu data |
| Delete ONU Go Adapter ETCD Data namespace=${INFRA_NAMESPACE} validate=True |
| Stop Logging Setup or Teardown Setup-${SUITE NAME} |
| |
| Teardown Suite |
| [Documentation] tear down the test suite |
| Run Keyword If ${pausebeforecleanup} Import Library Dialogs |
| Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up! |
| Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes |
| # close connection to kafka |
| kafka.Connection Close |
| # stop port forwarding if started |
| Run Keyword If ${PORT_FORWARDING} Terminate Process ${portFwdHandle} kill=true |
| # call common suite teardown |
| utils.Teardown Suite |
| # delete etcd MIB Template Data |
| Delete MIB Template Data ${INFRA_NAMESPACE} |
| # delete etcd onu data |
| Delete ONU Go Adapter ETCD Data namespace=${INFRA_NAMESPACE} validate=True |
| Close All ONOS SSH Connections |
| |
| Setup Test |
| [Documentation] Pre-test Setup |
| #test for empty device list |
| Test Empty Device List |
| Run Keyword If ${has_dataplane} Wait Until Keyword Succeeds 120s 10s Openolt is Up |
| ... ${olt_ssh_ip} ${olt_user} ${olt_pass} |
| Run Keyword If ${has_dataplane} Sleep 60s |
| Run Keyword If "${firsttest}"=="False" Sleep 35s |
| ${firsttest} Set Variable False |
| Set Suite Variable ${firsttest} |
| # Create a list of olt ids (logical and device_id) |
| ${olt_ids} Create List |
| FOR ${I} IN RANGE 0 ${num_olts} |
| #create/preprovision device |
| ${olt_device_id}= Run Keyword If "${list_olts}[${I}][type]" == "${None}" |
| ... Create Device ${list_olts}[${I}][ip] ${list_olts}[${I}][oltport] |
| ... ELSE Create Device ${list_olts}[${I}][ip] ${list_olts}[${I}][oltport] ${list_olts}[${I}][type] |
| ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| #validate olt states |
| Wait Until Keyword Succeeds ${timeout} 5s |
| ... Validate OLT Device PREPROVISIONED UNKNOWN UNKNOWN ${olt_device_id} by_dev_id=True |
| Sleep 5s |
| ${logical_id}= Get Logical Device ID From SN ${olt_serial_number} |
| ${olt} Create Dictionary device_id ${olt_device_id} logical_id ${logical_id} |
| ... of_id ${of_id} sn ${olt_serial_number} |
| Append To List ${olt_ids} ${olt} |
| END |
| Set Global Variable ${olt_ids} |