blob: 7d3930ec8353749f66880a6864f18cb8e8f9eb0c [file] [log] [blame]
# Copyright 2021 - present Open Networking Foundation
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
# FIXME Can we use the same test against BBSim and Hardware?
*** Settings ***
Documentation Tests ONU Software Upgrade
Suite Setup Setup Suite
Test Setup Setup
Test Teardown Teardown
Suite Teardown Teardown Suite
Library Collections
Library String
Library OperatingSystem
Library XML
Library RequestsLibrary
Library ../../libraries/DependencyLibrary.py
Resource ../../libraries/onos.robot
Resource ../../libraries/voltctl.robot
Resource ../../libraries/voltha.robot
Resource ../../libraries/utils.robot
Resource ../../libraries/k8s.robot
Resource ../../libraries/onu_utilities.robot
Resource ../../libraries/bbsim.robot
Resource ../../variables/variables.robot
*** Variables ***
${POD_NAME} flex-ocp-cord
${KUBERNETES_CONF} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf
${KUBERNETES_CONFIGS_DIR} ~/pod-configs/kubernetes-configs
#${KUBERNETES_CONFIGS_DIR} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf
${KUBERNETES_YAML} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.yml
${HELM_CHARTS_DIR} ~/helm-charts
${VOLTHA_POD_NUM} 8
${NAMESPACE} voltha
${INFRA_NAMESPACE} default
# For below variable value, using deployment name as using grep for
# parsing radius pod name, we can also use full radius pod name
${RESTART_POD_NAME} radius
${timeout} 60s
${of_id} 0
${logical_id} 0
${has_dataplane} True
${teardown_device} False
${scripts} ../../scripts
# Per-test logging on failure is turned off by default; set this variable to enable
${container_log_dir} ${None}
${suppressaddsubscriber} True
# logging flag to enable Collect Logs, can be passed via the command line too
# example: -v logging:False
${logging} True
# ONU Image to test for Upgrade needs to be passed in the following format:
${image_version} ${EMPTY}
# Example value: BBSM_IMG_00002
${image_url} ${EMPTY}
# Example value: http://bbsim0:50074/images/software-image.img
${image_vendor} ${EMPTY}
# Example value: BBSM
${image_activate_on_success} ${EMPTY}
# Example value: false
${image_commit_on_success} ${EMPTY}
# Example value: false
${image_crc} ${EMPTY}
# Example value: 0
# when voltha is running in k8s port forwarding is needed
# example: -v PORT_FORWARDING:False
${PORT_FORWARDING} True
# Next values are default values for port forward, do not need to be passed, will be overwritten by values taken from image-url
# bbsim webserver port
# example: -v BBSIM_WEBSERVER_PORT:50074
${BBSIM_WEBSERVER_PORT} 50074
# bbsim instance
# example: -v BBSIM_INSTANCE:bbsim0
${BBSIM_INSTANCE} bbsim0
# port forward handle
${portFwdHandle} None
# Log Level of Helm chart
# example: -v helmloglevel:WARN
${helmloglevel} DEBUG
*** Test Cases ***
Test ONU Upgrade
[Documentation] Validates the ONU Upgrade doesn't affect the system functionality
... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable
... Requirement: Pass image details in following parameters in the robot command
... onu_image_name, onu_image_url, onu_image_version, onu_image_crc, onu_image_local_dir
... Note: The TC expects the image url and other parameters to be common for all ONUs on all BBSim
... Check [VOL-3903] for more details
[Tags] functional ONUUpgrade
[Setup] Start Logging ONUUpgrade
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Delete All Devices and Verify
... AND Restart And Check BBSIM ${NAMESPACE}
... AND Stop Logging ONUUpgrade
Do ONU Upgrade All OLTs
Test ONU Upgrade All Activate and Commit Combinations
[Documentation] Validates the ONU Upgrade doesn't affect the system functionality by use all combinations of
... flags activate_on_success and commit_on_success
... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable
... Requirement: Pass image details in following parameters in the robot command
... onu_image_name, onu_image_url, onu_image_version, onu_image_crc, onu_image_local_dir
... Note: The TC expects the image url and other parameters to be common for all ONUs on all BBSim
... Check [VOL-4250] for more details
[Tags] functional ONUUpgradeAllCombies
[Setup] Start Logging ONUUpgradeAllCombies
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Delete All Devices and Verify
... AND Restart And Check BBSIM ${NAMESPACE}
... AND Stop Logging ONUUpgradeAllCombies
${false_false}= Create Dictionary activate false commit false
${true_false}= Create Dictionary activate true commit false
${false_true}= Create Dictionary activate false commit true
${true_true}= Create Dictionary activate true commit true
${flag_list}= Create List ${false_false} ${true_false} ${false_true} ${true_true}
FOR ${item} IN @{flag_list}
Do ONU Upgrade All OLTs ${item['activate']} ${item['commit']}
Delete All Devices and Verify
Restart And Check BBSIM ${NAMESPACE}
END
Test ONU Upgrade Correct Indication of Download Wrong Url
[Documentation] Validates the ONU Upgrade download from wrong URL failure will be indicated correctly
... and doesn't affect the system functionality
... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable
... Check [VOL-4257] for more details
[Tags] functional ONUUpgradeDownloadWrongUrl
[Setup] Start Logging ONUUpgradeDownloadWrongUrl
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Delete All Devices and Verify
... AND Restart And Check BBSIM ${NAMESPACE}
... AND Stop Logging ONUUpgradeDownloadWrongUrl
# Add OLT device
Setup
# Performing Sanity Test to make sure subscribers are all DHCP and pingable
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
FOR ${J} IN RANGE 0 ${num_olts}
${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
${bbsim_rel}= Catenate SEPARATOR= bbsim ${J}
${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel}
Do ONU Upgrade Download Failure Per OLT ${bbsim_pod} ${olt_serial_number}
... url=http://bbsim0:50074/images/wrong-image.img$
... dwl_dwlstate=DOWNLOAD_FAILED dwl_reason=INVALID_URL dwl_imgstate=IMAGE_UNKNOWN
... dwlstate=DOWNLOAD_UNKNOWN reason=NO_ERROR imgstate=IMAGE_UNKNOWN
List ONUs ${NAMESPACE} ${bbsim_pod}
END
# Additional Verification
Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify
Setup
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
Test ONU Upgrade Correct Indication of Download Failure
[Documentation] Validates the ONU Upgrade download failure will be indicated correctly and
... doesn't affect the system functionality
... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable
... Check [VOL-3935] for more details
[Tags] functional ONUUpgradeDownloadFailure
[Setup] Start Logging ONUUpgradeDownloadFailure
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Delete All Devices and Verify
... AND Restart And Check BBSIM ${NAMESPACE}
... AND Stop Logging ONUUpgradeDownloadFailure
# Add OLT device
Setup
# Performing Sanity Test to make sure subscribers are all DHCP and pingable
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
FOR ${J} IN RANGE 0 ${num_olts}
${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
${bbsim_rel}= Catenate SEPARATOR= bbsim ${J}
${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel}
Do ONU Upgrade Download Failure Per OLT ${bbsim_pod} ${olt_serial_number}
... dwlstate=DOWNLOAD_FAILED reason=CANCELLED_ON_ONU_STATE imgstate=IMAGE_UNKNOWN
List ONUs ${NAMESPACE} ${bbsim_pod}
END
# Additional Verification
Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify
Setup
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
Test ONU Upgrade Correct Indication of Downloading Abort
[Documentation] Validates the ONU Upgrade downloading abort will be indicated correctly and
... doesn't affect the system functionality
... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable
... Check [VOL-4318] for more details
[Tags] functional ONUUpgradeDownloadingAbort
[Setup] Start Logging ONUUpgradeDownloadingAbort
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Delete All Devices and Verify
... AND Restart And Check BBSIM ${NAMESPACE}
... AND Stop Logging ONUUpgradeDownloadingAbort
# Add OLT device
Setup
# Performing Sanity Test to make sure subscribers are all DHCP and pingable
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
FOR ${J} IN RANGE 0 ${num_olts}
${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
${bbsim_rel}= Catenate SEPARATOR= bbsim ${J}
${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel}
Do ONU Upgrade Downloading Abort Per OLT ${bbsim_pod} ${olt_serial_number}
List ONUs ${NAMESPACE} ${bbsim_pod}
END
# Additional Verification
Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify
Setup
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
Test ONU Upgrade Correct Indication of Downloaded Abort
[Documentation] Validates the ONU Upgrade downloaded abort will be indicated correctly and
... doesn't affect the system functionality
... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable
... Check [VOL-4320] for more details
[Tags] functional ONUUpgradeDownloadedAbort
[Setup] Start Logging ONUUpgradeDownloadedAbort
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Delete All Devices and Verify
... AND Restart And Check BBSIM ${NAMESPACE}
... AND Stop Logging ONUUpgradeDownloadedAbort
# Add OLT device
Setup
# Performing Sanity Test to make sure subscribers are all DHCP and pingable
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
FOR ${J} IN RANGE 0 ${num_olts}
${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
${bbsim_rel}= Catenate SEPARATOR= bbsim ${J}
${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel}
Do ONU Upgrade Downloaded Abort Per OLT ${bbsim_pod} ${olt_serial_number}
List ONUs ${NAMESPACE} ${bbsim_pod}
END
# Additional Verification
Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify
Setup
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
Test ONU Upgrade Correct Indication of Activating Abort
[Documentation] Validates the ONU Upgrade activating abort will be indicated correctly and
... doesn't affect the system functionality
... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable
... Check [VOL-4319] for more details
[Tags] functional ONUUpgradeActivatingAbort
[Setup] Start Logging ONUUpgradeActivatingAbort
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Delete All Devices and Verify
... AND Restart And Check BBSIM ${NAMESPACE}
... AND Stop Logging ONUUpgradeActivatingAbort
# Add OLT device
Setup
# Performing Sanity Test to make sure subscribers are all DHCP and pingable
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
FOR ${J} IN RANGE 0 ${num_olts}
${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
${bbsim_rel}= Catenate SEPARATOR= bbsim ${J}
${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel}
Do ONU Upgrade Activating Abort Per OLT ${bbsim_pod} ${olt_serial_number}
List ONUs ${NAMESPACE} ${bbsim_pod}
END
# Additional Verification
Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify
Setup
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
Test ONU Upgrade Correct Indication of Active Abort
[Documentation] Validates the ONU Upgrade active abort will be indicated correctly and
... doesn't affect the system functionality
... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable
... Check [VOL-4320] for more details
[Tags] functional ONUUpgradeActiveAbort
[Setup] Start Logging ONUUpgradeActiveAbort
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Delete All Devices and Verify
... AND Restart And Check BBSIM ${NAMESPACE}
... AND Stop Logging ONUUpgradeActiveAbort
# Add OLT device
Setup
# Performing Sanity Test to make sure subscribers are all DHCP and pingable
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
FOR ${J} IN RANGE 0 ${num_olts}
${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
${bbsim_rel}= Catenate SEPARATOR= bbsim ${J}
${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel}
Do ONU Upgrade Active Abort Per OLT ${bbsim_pod} ${olt_serial_number}
List ONUs ${NAMESPACE} ${bbsim_pod}
END
# Additional Verification
Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify
Setup
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
Test ONU Upgrade Correct Indication of Committed Abort
[Documentation] Validates the ONU Upgrade committed abort will be indicated correctly and
... doesn't affect the system functionality. Check BBSIM server transfer image counter after further download,
... counter should be incremented.
... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable
... Check [VOL-4320] for more details
[Tags] functional ONUUpgradeCommittedAbort
[Setup] Start Logging ONUUpgradeCommittedAbort
[Teardown] Run Keywords Run Keyword If ${portFwdHandle}!=None Terminate Process ${portFwdHandle} kill=true
... AND Set Suite Variable ${portFwdHandle} None
... AND Run Keyword If ${logging} Collect Logs
... AND Delete All Devices and Verify
... AND Restart And Check BBSIM ${NAMESPACE}
... AND Stop Logging ONUUpgradeCommittedAbort
# Add OLT device
Setup
# Performing Sanity Test to make sure subscribers are all DHCP and pingable
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
# in case of bbsim is running in k8s port forwarding of WEBSERVER is needed
${BBSIM_INSTANCE} ${BBSIM_WEBSERVER_PORT}= Run Keyword If '${image_url}'!='${EMPTY}' Get BBSIM Svc and Webserver Port
${cmd} Catenate
... kubectl port-forward --address 0.0.0.0 -n ${NAMESPACE} svc/${BBSIM_INSTANCE}
... ${BBSIM_WEBSERVER_PORT}:${BBSIM_WEBSERVER_PORT} &
${portFwdHandle}= Run Keyword If ${PORT_FORWARDING} Start Process ${cmd} shell=true
Set Suite Variable ${portFwdHandle}
Sleep 5s
FOR ${J} IN RANGE 0 ${num_olts}
${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
${bbsim_rel}= Catenate SEPARATOR= bbsim ${J}
${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel}
Do ONU Upgrade Committed Abort Per OLT ${bbsim_pod} ${olt_serial_number}
List ONUs ${NAMESPACE} ${bbsim_pod}
END
# Additional Verification
Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify
Setup
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
Test ONU Upgrade Correct Indication Multiple Image Download
[Documentation] Validates the ONU Upgrade multiple Image Download will be indicated correctly,
... In case of (re-) download the same image without aborting the cached one in openonu-adapter should taken,
... no further download from server has executed. Check BBSIM server transfer image counter after further download,
... counter should NOT be incremented.
... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable
... Check [VOL-4320] for more details
[Tags] functional ONUUpgradeMultipleImageDownload
[Setup] Start Logging ONUUpgradeMultipleImageDownload
[Teardown] Run Keywords Run Keyword If ${portFwdHandle}!=None Terminate Process ${portFwdHandle} kill=true
... AND Set Suite Variable ${portFwdHandle} None
... AND Run Keyword If ${logging} Collect Logs
... AND Delete All Devices and Verify
... AND Restart And Check BBSIM ${NAMESPACE}
... AND Stop Logging ONUUpgradeMultipleImageDownload
# Add OLT device
Setup
# Performing Sanity Test to make sure subscribers are all DHCP and pingable
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
# in case of bbsim is running in k8s port forwarding of WEBSERVER is needed
${BBSIM_INSTANCE} ${BBSIM_WEBSERVER_PORT}= Run Keyword If '${image_url}'!='${EMPTY}' Get BBSIM Svc and Webserver Port
${cmd} Catenate
... kubectl port-forward --address 0.0.0.0 -n ${NAMESPACE} svc/${BBSIM_INSTANCE}
... ${BBSIM_WEBSERVER_PORT}:${BBSIM_WEBSERVER_PORT} &
${portFwdHandle}= Run Keyword If ${PORT_FORWARDING} Start Process ${cmd} shell=true
Set Suite Variable ${portFwdHandle}
Sleep 5s
FOR ${J} IN RANGE 0 ${num_olts}
${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
${bbsim_rel}= Catenate SEPARATOR= bbsim ${J}
${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel}
Do ONU Upgrade Multiple Image Download Per OLT ${bbsim_pod} ${olt_serial_number}
List ONUs ${NAMESPACE} ${bbsim_pod}
END
# Additional Verification
Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify
Setup
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
Test ONU Upgrade Compare OMCI Message Version
[Documentation] Validates the ONU Upgrade duration depending on OMCI message version
... - setup one ONU with baseline OMCI message (EXTRA_HELM_FLAGS=" --set omccVersion=163)
... - perform a SW upgrade
... - store SW upgrade duration
... - delete all devices
... - setup one ONU with extended OMCI message (EXTRA_HELM_FLAGS=" --set omccVersion=180)
... - perform a SW upgrade
... - store SW upgrade duration
... - compare both duration
... - duration of extended msg ONU should be at least less than 80% of the baseline one
... Check [VOL-4733] for more details
[Tags] functional ONUUpgradeOmciBaselineVersusExtendedOnuGo
[Setup] Start Logging ONUUpgradeOmciBaselineVersusExtendedOnuGo
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Delete All Devices and Verify
... AND Restart And Check BBSIM ${NAMESPACE}
... AND Stop Logging ONUUpgradeOmciBaselineVersusExtendedOnuGo
Do ONU Upgrade Compare OMCI Message Version
Test ONU Upgrade Image Download Simultaneously
[Documentation] Validates the ONU Upgrade Image Download to all ONUs simultaneously.
... Test case should executed in multiple ONU (OLT) environment!
... Performs the sanity and verifies all the ONUs are authenticated/DHCP/pingable
... Check [VOL-4320] for more details
[Tags] functionalMultipleONUs ONUUpgradeImageDownloadSimultaneously
[Setup] Start Logging ONUUpgradeImageDownloadSimultaneously
[Teardown] Run Keywords Run Keyword If ${portFwdHandle}!=None Terminate Process ${portFwdHandle} kill=true
... AND Set Suite Variable ${portFwdHandle} None
... AND Run Keyword If ${logging} Collect Logs
... AND Delete All Devices and Verify
... AND Restart And Check BBSIM ${NAMESPACE}
... AND Stop Logging ONUUpgradeImageDownloadSimultaneously
# Add OLT device
Setup
# Performing Sanity Test to make sure subscribers are all DHCP and pingable
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
# in case of bbsim is running in k8s port forwarding of WEBSERVER is needed
${BBSIM_INSTANCE} ${BBSIM_WEBSERVER_PORT}= Run Keyword If '${image_url}'!='${EMPTY}' Get BBSIM Svc and Webserver Port
${cmd} Catenate
... kubectl port-forward --address 0.0.0.0 -n ${NAMESPACE} svc/${BBSIM_INSTANCE}
... ${BBSIM_WEBSERVER_PORT}:${BBSIM_WEBSERVER_PORT} &
${portFwdHandle}= Run Keyword If ${PORT_FORWARDING} Start Process ${cmd} shell=true
Set Suite Variable ${portFwdHandle}
Sleep 5s
Do ONU Upgrade Image Download Simultaneously
# Additional Verification
Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify
Setup
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
*** Keywords ***
Do ONU Upgrade All OLTs
[Documentation] This keyword performs the ONU Upgrade test on all OLTs
[Arguments] ${activate_on_success}=${image_activate_on_success} ${commit_on_success}=${image_commit_on_success}
# Add OLT device
Setup
# Performing Sanity Test to make sure subscribers are all DHCP and pingable
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
FOR ${J} IN RANGE 0 ${num_olts}
${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
${bbsim_rel}= Catenate SEPARATOR= bbsim ${J}
${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel}
Do ONU Upgrade Per OLT ${bbsim_pod} ${olt_serial_number} ${activate_on_success} ${commit_on_success}
List ONUs ${NAMESPACE} ${bbsim_pod}
END
# Additional Verification
Wait Until Keyword Succeeds ${timeout} 2s Delete All Devices and Verify
Setup
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
Do ONU Upgrade Per OLT
[Documentation] This keyword performs the ONU Upgrade test on single OLT
[Arguments] ${bbsim_pod} ${olt_serial_number} ${activate_on_success}=${image_activate_on_success}
... ${commit_on_success}=${image_commit_on_success}
[Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image ${image_version} ${onu_device_id}
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
${onu_device_id}= Get Device ID From SN ${src['onu']}
# Download Image
Download ONU Device Image ${image_version} ${image_url} ${image_vendor}
... ${activate_on_success} ${commit_on_success}
... ${image_crc} ${onu_device_id}
${imageState}= Run Keyword If '${activate_on_success}'=='true' and '${commit_on_success}'=='false'
... Set Variable IMAGE_ACTIVE
... ELSE IF '${activate_on_success}'=='true' and '${commit_on_success}'=='true'
... Set Variable IMAGE_COMMITTED
... ELSE Set Variable IMAGE_INACTIVE
${activated}= Set Variable If '${activate_on_success}'=='true' True False
${committed}= Set Variable If '${activate_on_success}'=='true' and '${commit_on_success}'=='true'
... True False
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR ${imageState}
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id}
... ${image_version} ${committed} ${activated} True
# Activate Image
${imageState}= Set Variable If '${commit_on_success}'=='true' IMAGE_COMMITTED IMAGE_ACTIVE
${committed}= Set Variable If '${commit_on_success}'=='true' True False
Run Keyword If '${activate_on_success}'=='false' Run Keywords
... Activate ONU Device Image ${image_version} ${commit_on_success} ${onu_device_id}
... AND Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR ${imageState}
... AND Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id}
... ${image_version} ${committed} True True
# Commit Image
Run Keyword If '${commit_on_success}'=='false' Run Keywords
... Commit ONU Device Image ${image_version} ${onu_device_id}
... AND Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_COMMITTED
... AND Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id}
... ${image_version} True True True
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image On BBSim ${NAMESPACE} ${bbsim_pod}
... ${src['onu']} software_image_committed
Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber}
# to remove the image again from adapter, Multi-Onu tests could be restructured - not yet in focus
Remove Adapter Image ${image_version} ${onu_device_id}
END
Do ONU Upgrade Download Failure Per OLT
[Documentation] This keyword performs the ONU Upgrade Dowload Failure test on single OLT
[Arguments] ${bbsim_pod} ${olt_serial_number} ${url}=${image_url}
... ${dwl_dwlstate}=DOWNLOAD_STARTED ${dwl_reason}=NO_ERROR ${dwl_imgstate}=IMAGE_UNKNOWN
... ${dwlstate}=DOWNLOAD_SUCCEEDED ${reason}=NO_ERROR ${imgstate}=IMAGE_INACTIVE
[Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image INVALID_IMAGE ${onu_device_id}
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
${onu_device_id}= Get Device ID From SN ${src['onu']}
# Download Image
Download ONU Device Image INVALID_IMAGE ${url} ${image_vendor}
... ${image_activate_on_success} ${image_commit_on_success} ${image_crc} ${onu_device_id}
... download_state=${dwl_dwlstate} expected_reason=${dwl_reason} image_state=${dwl_imgstate}
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status INVALID_IMAGE
... ${onu_device_id} ${dwlstate} ${reason} ${imgstate}
Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber}
# to remove the image again from adapter, Multi-Onu tests could be restructured - not yet in focus
Remove Adapter Image INVALID_IMAGE ${onu_device_id}
END
Do ONU Upgrade Downloading Abort Per OLT
[Documentation] This keyword performs the ONU Upgrade Downloading Abort test on single OLT
[Arguments] ${bbsim_pod} ${olt_serial_number} ${url}=${image_url}
[Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image ${image_version} ${onu_device_id}
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
${onu_device_id}= Get Device ID From SN ${src['onu']}
# Download Image
Download ONU Device Image ${image_version} ${url} ${image_vendor}
... ${image_activate_on_success} ${image_commit_on_success} ${image_crc} ${onu_device_id}
Abort ONU Device Image ${image_version} ${onu_device_id}
... DOWNLOAD_STARTED CANCELLED_ON_REQUEST IMAGE_DOWNLOADING
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_CANCELLED CANCELLED_ON_REQUEST IMAGE_UNKNOWN
# !!! Expected is image is not visible in list !!!
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id}
... ${image_version} False False False image_should_not_in_list=True
Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber}
END
Do ONU Upgrade Downloaded Abort Per OLT
[Documentation] This keyword performs the ONU Upgrade Downloaded Abort test on single OLT
[Arguments] ${bbsim_pod} ${olt_serial_number} ${url}=${image_url}
[Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image ${image_version} ${onu_device_id}
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
${onu_device_id}= Get Device ID From SN ${src['onu']}
# Download Image
Download ONU Device Image ${image_version} ${url} ${image_vendor}
... false false ${image_crc} ${onu_device_id}
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_INACTIVE
Abort ONU Device Image ${image_version} ${onu_device_id}
... DOWNLOAD_SUCCEEDED CANCELLED_ON_REQUEST IMAGE_INACTIVE
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED CANCELLED_ON_REQUEST IMAGE_INACTIVE
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id}
... ${image_version} False False True
Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber}
END
Do ONU Upgrade Activating Abort Per OLT
[Documentation] This keyword performs the ONU Upgrade Activating Abort test on single OLT
[Arguments] ${bbsim_pod} ${olt_serial_number} ${url}=${image_url}
[Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image ${image_version} ${onu_device_id}
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
${onu_device_id}= Get Device ID From SN ${src['onu']}
# Download Image
Download ONU Device Image ${image_version} ${url} ${image_vendor}
... false false ${image_crc} ${onu_device_id}
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_INACTIVE
Activate ONU Device Image ${image_version} false ${onu_device_id}
Abort ONU Device Image ${image_version} ${onu_device_id}
... DOWNLOAD_SUCCEEDED CANCELLED_ON_REQUEST IMAGE_ACTIVATING
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED CANCELLED_ON_REQUEST IMAGE_ACTIVATION_ABORTED
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id}
... ${image_version} False True True
Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber}
END
Do ONU Upgrade Active Abort Per OLT
[Documentation] This keyword performs the ONU Upgrade Active Abort test on single OLT
[Arguments] ${bbsim_pod} ${olt_serial_number} ${url}=${image_url}
[Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image ${image_version} ${onu_device_id}
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
${onu_device_id}= Get Device ID From SN ${src['onu']}
# Download Image
Download ONU Device Image ${image_version} ${url} ${image_vendor}
... false false ${image_crc} ${onu_device_id}
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_INACTIVE
Activate ONU Device Image ${image_version} false ${onu_device_id}
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_ACTIVE
Abort ONU Device Image ${image_version} ${onu_device_id}
... DOWNLOAD_SUCCEEDED CANCELLED_ON_REQUEST IMAGE_ACTIVE
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED CANCELLED_ON_REQUEST IMAGE_ACTIVE
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id}
... ${image_version} False True True
Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber}
END
Do ONU Upgrade Committed Abort Per OLT
[Documentation] This keyword performs the ONU Upgrade Committed Abort test on single OLT
[Arguments] ${bbsim_pod} ${olt_serial_number} ${url}=${image_url}
[Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image ${image_version} ${onu_device_id}
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
${onu_device_id}= Get Device ID From SN ${src['onu']}
${Images_Count_Start}= Get Images Count
# Download Image
Download ONU Device Image ${image_version} ${url} ${image_vendor}
... false false ${image_crc} ${onu_device_id}
# After download of image, check image counter of BBSIM, has to be incremented by 2, because bbsim increments counter
# whenever openonu adapter touch the image, so one increment for check image is available and one for downloading
${Images_Count_First}= Get Images Count
${Images_Count_Start}= Evaluate ${Images_Count_Start}+2
Should Be Equal as Integers ${Images_Count_First} ${Images_Count_Start} Count of image download not correct!
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_INACTIVE
Activate ONU Device Image ${image_version} false ${onu_device_id}
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_ACTIVE
Commit ONU Device Image ${image_version} ${onu_device_id}
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_COMMITTED
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id}
... ${image_version} True True True
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image On BBSim ${NAMESPACE} ${bbsim_pod}
... ${src['onu']} software_image_committed
Abort ONU Device Image ${image_version} ${onu_device_id}
... DOWNLOAD_UNKNOWN NO_ERROR IMAGE_UNKNOWN
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_UNKNOWN NO_ERROR IMAGE_UNKNOWN
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id}
... ${image_version} True True True
Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber}
${Images_Count_Intermediate}= Get Images Count
# Repeat download of aborted image, check image counter of BBSIM, has to be incremented by 2, because bbsim increments
# whenever openonu adapter touch the image, so one increment for check image is available and one for downloading
Download ONU Device Image ${image_version} ${url} ${image_vendor}
... false false ${image_crc} ${onu_device_id}
${Images_Count_End}= Get Images Count
${Images_Count_Intermediate}= Evaluate ${Images_Count_Intermediate}+2
Should Be Equal as Integers ${Images_Count_End} ${Images_Count_Intermediate} Count of image download not correct!
Remove Adapter Image ${image_version} ${onu_device_id}
END
Do ONU Upgrade Multiple Image Download Per OLT
[Documentation] This keyword performs the ONU Upgrade Image Download test on single OLT
[Arguments] ${bbsim_pod} ${olt_serial_number} ${url}=${image_url}
[Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' Remove Adapter Image ${image_version} ${onu_device_id}
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
${onu_device_id}= Get Device ID From SN ${src['onu']}
${Images_Count_Start}= Get Images Count
# Download Image
Download ONU Device Image ${image_version} ${url} ${image_vendor}
... true true ${image_crc} ${onu_device_id}
# After download of image, check image counter of BBSIM, has to be incremented by 2, because bbsim increments counter
# whenever openonu adapter touch the image, so one increment for check image is available and one for downloading
${Images_Count_First}= Get Images Count
${Images_Count_Start}= Evaluate ${Images_Count_Start}+2
Should Be Equal as Integers ${Images_Count_First} ${Images_Count_Start} Count of image download not correct!
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_COMMITTED
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id}
... ${image_version} True True True
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image On BBSim ${NAMESPACE} ${bbsim_pod}
... ${src['onu']} software_image_committed
Wait Until Keyword Succeeds ${timeout} 5s Perform Sanity Test ${suppressaddsubscriber}
${Images_Count_Intermediate}= Get Images Count
# Repeat download of same image, check image counter of BBSIM, has to be not incremented, because no download from
# server will be executed, the cached one from openonu-adapter will taken
Download ONU Device Image ${image_version} ${url} ${image_vendor}
... false false ${image_crc} ${onu_device_id}
${Images_Count_End}= Get Images Count
Should Be Equal as Integers ${Images_Count_End} ${Images_Count_Intermediate} Count of image download not correct!
Remove Adapter Image ${image_version} ${onu_device_id}
END
Do ONU Upgrade Compare OMCI Message Version
[Documentation] This keyword performs the ONU Upgrade Compare OMCI Message Version test for the first OLT/ONU
[Arguments] ${activate_on_success}=${image_activate_on_success} ${commit_on_success}=${image_commit_on_success}
[Teardown] Run Keyword If '${KEYWORD STATUS}'=='FAIL' and '${onu_device_id}'!='${EMPTY}'
... Remove Adapter Image ${image_version} ${onu_device_id}
${onu_device_id}= Set Variable ${EMPTY}
${firstonu}= Set Variable 0
${outputfile}= Set variable ${OUTPUTDIR}/ONU_SW_Upgrade_Time.txt
${omcc_version} ${is_omcc_extended}= Get BBSIM OMCC Version ${NAMESPACE}
# Restart BBSIM with OMCI Baseline Message if needed
Create File ${outputfile} This file contains the SW Upgrade download durations
${extra_helm_flags} Catenate --set omccVersion=163
Run Keyword If ${is_omcc_extended} Restart BBSIM by Helm Charts ${NAMESPACE} extra_helm_flags=${extra_helm_flags}
# Add OLT device
Setup
${src}= Set Variable ${hosts.src[${firstonu}]}
${onu_device_id}= Get Device ID From SN ${src['onu']}
${admin_state} ${oper_status} ${connect_status} ${onu_state_nb} ${onu_state}=
... Map State omci-flows-pushed
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 1s
... Validate Device ${admin_state} ${oper_status} ${connect_status}
... ${src['onu']} onu=True onu_reason=${onu_state}
${baselineonu}= Get ONU SW Upgrade Duration ${firstonu} ${activate_on_success} ${commit_on_success}
Log ONU ${src['onu']}: downloaded SW upgrade in ${baselineonu} sec for OMCI baseline message. console=yes
Append To File ${outputfile}
... \r\nONU ${src['onu']} downloaded SW upgrade in ${baselineonu} sec for OMCI baseline message.
Delete All Devices and Verify
# Restart BBSIM with OMCI Extended Message
${extra_helm_flags}= Run Keyword If ${is_omcc_extended} Catenate --set omccVersion=${omcc_version}
... ELSE Catenate --set omccVersion=180
Restart BBSIM by Helm Charts ${NAMESPACE} extra_helm_flags=${extra_helm_flags}
# Start Onu again with OMCI Extended Message
Setup
${onu_device_id}= Get Device ID From SN ${src['onu']}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 1s
... Validate Device ${admin_state} ${oper_status} ${connect_status}
... ${src['onu']} onu=True onu_reason=${onu_state}
${extendedonu}= Get ONU SW Upgrade Duration ${firstonu} ${activate_on_success} ${commit_on_success}
Log ONU ${src['onu']}: downloaded SW upgrade in ${extendedonu} sec for OMCI extended message. console=yes
Append To File ${outputfile}
... \r\nONU ${src['onu']} downloaded SW upgrade in ${extendedonu} sec for OMCI extended message.
${duration_compare}= Evaluate ${baselineonu}*0.8 > ${extendedonu}
Should Be True ${duration_compare} SW Upgrade too slow for OMCI extended message!
# Restart BBSIM with OMCI Message Version read at begin of test
${extra_helm_flags}= Catenate --set omccVersion=${omcc_version}
Run Keyword Unless ${is_omcc_extended} Restart BBSIM by Helm Charts ${NAMESPACE} extra_helm_flags=${extra_helm_flags}
Get ONU SW Upgrade Duration
[Documentation] This keyword delivers SW Upgrade duration of onu
[Arguments] ${onu} ${activate_on_success} ${commit_on_success}
${src}= Set Variable ${hosts.src[${onu}]}
${onu_device_id}= Get Device ID From SN ${src['onu']}
${timeStart}= Get Current Date
Download ONU Device Image ${image_version} ${image_url} ${image_vendor}
... ${activate_on_success} ${commit_on_success}
... ${image_crc} ${onu_device_id}
${imageState}= Run Keyword If '${activate_on_success}'=='true' and '${commit_on_success}'=='false'
... Set Variable IMAGE_ACTIVE
... ELSE IF '${activate_on_success}'=='true' and '${commit_on_success}'=='true'
... Set Variable IMAGE_COMMITTED
... ELSE Set Variable IMAGE_INACTIVE
${activated}= Set Variable If '${activate_on_success}'=='true' True False
${committed}= Set Variable If '${activate_on_success}'=='true' and '${commit_on_success}'=='true'
... True False
Wait Until Keyword Succeeds ${timeout} 0s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR ${imageState}
${timeCurrent} = Get Current Date
${timeTotalMs} = Subtract Date From Date ${timeCurrent} ${timeStart} result_format=number
Remove Adapter Image ${image_version} ${onu_device_id}
[Return] ${timeTotalMs}
Do ONU Upgrade Image Download Simultaneously
[Documentation] This keyword performs the ONU Upgrade Image Download Simultaneously on all ONUs test
[Arguments] ${url}=${image_url}
[Teardown] Remove Adapter Image from ONUs ${image_version} ${list_onus}
# collect all ONU's device ids
${list_onus} Create List
Build ONU Device Id List ${list_onus}
# prepare OLT-SN BBSIM-POD releation dictionary for later fast access
${olt_bbsim_dict}= Create Dictionary
FOR ${J} IN RANGE 0 ${num_olts}
${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
${bbsim_rel}= Catenate SEPARATOR= bbsim ${J}
${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release ${bbsim_rel}
Set To Dictionary ${olt_bbsim_dict} ${olt_serial_number} ${bbsim_pod}
END
${Images_Count_Start}= Get Images Count
# Download Image to all ONUs simultaneously
${onu_device_ids} = Catenate @{list_onus}
Download ONU Device Image ${image_version} ${url} ${image_vendor}
... true true ${image_crc} ${onu_device_ids}
# do all the check stuff
FOR ${onu_device_id} IN @{list_onus}
Log ${onu_device_id}
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image Status ${image_version}
... ${onu_device_id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_COMMITTED
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image List ${onu_device_id}
... ${image_version} True True True
END
# last but not least check bbsim
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${bbsim_pod}= Get From Dictionary ${olt_bbsim_dict} ${src['olt']}
Wait Until Keyword Succeeds ${timeout} 2s Verify ONU Device Image On BBSim ${NAMESPACE} ${bbsim_pod}
... ${src['onu']} software_image_committed
END
${Images_Count_End}= Get Images Count
${Images_Count_Start}= Evaluate ${Images_Count_Start}+2
Should Be Equal as Integers ${Images_Count_End} ${Images_Count_Start} Count of image download not correct!
Setup Suite
[Documentation] Set up the test suite
Start Logging Setup or Teardown Setup-${SUITE NAME}
Common Test Suite Setup
# set log level for org.onosproject.store.device.impl.GossipDeviceStore to TRACE to get reason for hanging ONOS resources
${LogLevelGossipDeviceStore}= Wait Until Keyword Succeeds ${timeout} 2s
... Execute ONOS CLI Command use single connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... log:get org.onosproject.store.device.impl.GossipDeviceStore
Set Suite Variable ${LogLevelGossipDeviceStore}
Log Old Log Level of GossipDeviceStore is ${LogLevelGossipDeviceStore}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Execute ONOS CLI Command use single connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... log:set TRACE org.onosproject.store.device.impl.GossipDeviceStore
${NewLogLevelGossipDeviceStore}= Wait Until Keyword Succeeds ${timeout} 2s
... Execute ONOS CLI Command use single connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... log:get org.onosproject.store.device.impl.GossipDeviceStore
Log New Log Level of GossipDeviceStore is ${NewLogLevelGossipDeviceStore}
Run Keyword If ${logging} Collect Logs
Stop Logging Setup or Teardown Setup-${SUITE NAME}
Teardown Suite
[Documentation] Tear down steps for the suite
Start Logging Setup or Teardown Teardown-${SUITE NAME}
# stop port forwarding if still running
Run Keyword If ${portFwdHandle}!=None Terminate Process ${portFwdHandle} kill=true
Run Keyword If ${has_dataplane} Clean Up Linux
Run Keyword If ${logging} Collect Logs
# reset log level for org.onosproject.store.device.impl.GossipDeviceStore to to previous level
${NewLogLevelGossipDeviceStore}= Wait Until Keyword Succeeds ${timeout} 2s
... Execute ONOS CLI Command use single connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... log:get org.onosproject.store.device.impl.GossipDeviceStore
Log Log Level of GossipDeviceStore is ${NewLogLevelGossipDeviceStore}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Execute ONOS CLI Command use single connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... log:set ${LogLevelGossipDeviceStore} org.onosproject.store.device.impl.GossipDeviceStore
${LogLevelGossipDeviceStore}= Wait Until Keyword Succeeds ${timeout} 2s
... Execute ONOS CLI Command use single connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... log:get org.onosproject.store.device.impl.GossipDeviceStore
Log New Log Level of GossipDeviceStore is ${LogLevelGossipDeviceStore}
Stop Logging Setup or Teardown Teardown-${SUITE NAME}
Close All ONOS SSH Connections