blob: 3e06882128a3020086064fababce909cb75d53c3 [file] [log] [blame]
# Copyright 2017 - present Open Networking Foundation
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
# FIXME Can we use the same test against BBSim and Hardware?
*** Settings ***
Documentation Test various end-to-end scenarios
Suite Setup Setup Suite
Test Setup Setup
Test Teardown Teardown
Suite Teardown Teardown Suite
Library Collections
Library String
Library OperatingSystem
Library XML
Library RequestsLibrary
Library ../../libraries/DependencyLibrary.py
Resource ../../libraries/onos.robot
Resource ../../libraries/voltctl.robot
Resource ../../libraries/voltha.robot
Resource ../../libraries/utils.robot
Resource ../../libraries/k8s.robot
Resource ../../variables/variables.robot
*** Variables ***
${POD_NAME} flex-ocp-cord
${KUBERNETES_CONF} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf
${KUBERNETES_CONFIGS_DIR} ~/pod-configs/kubernetes-configs
#${KUBERNETES_CONFIGS_DIR} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf
${KUBERNETES_YAML} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.yml
${HELM_CHARTS_DIR} ~/helm-charts
${VOLTHA_POD_NUM} 8
${NAMESPACE} voltha
# For below variable value, using deployment name as using grep for
# parsing radius pod name, we can also use full radius pod name
${RESTART_POD_NAME} radius
${timeout} 60s
${of_id} 0
${logical_id} 0
${has_dataplane} True
${teardown_device} False
${scripts} ../../scripts
# Per-test logging on failure is turned off by default; set this variable to enable
${container_log_dir} ${None}
*** Test Cases ***
Sanity E2E Test for OLT/ONU on POD for DT
[Documentation] Validates E2E Ping Connectivity and object states for the given scenario:
... Validate successful DHCP/E2E ping (no EAPOL and DHCP flows) for the tech profile that is used
... Traffic sent with same vlan from different RGs,
... should reach the NNI port on the OLT with the expected double tagged vlan ids
... Inner vlans from the RG should not change
[Tags] sanityDt
[Setup] Run Keywords Announce Message START TEST SanityTestDt
... AND Start Logging SanityTestDt
... AND Setup
[Teardown] Run Keywords Collect Logs
... AND Stop Logging SanityTestDt
... AND Announce Message END TEST SanityTestDt
Run Keyword If ${has_dataplane} Clean Up Linux
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test DT
Test Subscriber Delete and Add for DT
[Documentation] Validates E2E Ping Connectivity and object states for the given scenario:
... Assuming that all the ONUs are DHCP/pingable (i.e. assuming sanityDt test was executed)
... Delete a subscriber and validate that the pings do not succeed and state is purged
... Disable and Enable the ONU (This is to replicate the existing DT behaviour)
... Re-add the subscriber, and validate that the flows are present and pings are successful
[Tags] functionalDt SubAddDeleteDt
[Setup] Run Keywords Announce Message START TEST SubAddDeleteDt
... AND Start Logging SubAddDeleteDt
[Teardown] Run Keywords Collect Logs
... AND Stop Logging SubAddDeleteDt
... AND Announce Message END TEST SubAddDeleteDt
FOR ${I} IN RANGE 0 ${num_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
${onu_device_id}= Get Device ID From SN ${src['onu']}
${onu_port}= Wait Until Keyword Succeeds ${timeout} 2s Get ONU Port in ONOS ${src['onu']}
... ${of_id}
# Remove Subscriber Access
Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-remove-subscriber-access ${of_id} ${onu_port}
Sleep 10s
# TODO: Yet to Verify on the GPON based Physical POD (VOL-2652)
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds 60s 2s
... Check Ping False ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
# Number of Access Flows on ONOS equals 4 * the Number of Active ONUs (2 for each downstream and upstream)
${onos_flows_count}= Evaluate 4 * ( ${num_onus} - 1 )
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Verify Subscriber Access Flows Added Count DT ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... ${of_id} ${onos_flows_count}
# Verify VOLTHA flows for OLT equals twice the number of ONUS (minus ONU under test) + 1 for LLDP
${olt_flows}= Evaluate 2 * ( ${num_onus} - 1 ) + 1
Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Flows ${olt_flows}
# Verify VOLTHA flows for ONU under test is Zero
Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate Device Flows
... ${onu_device_id} 0
# Disable and Re-Enable the ONU (To replicate DT current workflow)
# TODO: Delete and Auto-Discovery Add of ONU (not yet supported)
Disable Device ${onu_device_id}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Device DISABLED UNKNOWN
... REACHABLE ${src['onu']}
Enable Device ${onu_device_id}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Device ENABLED ACTIVE
... REACHABLE ${src['onu']}
# Add Subscriber Access
Wait Until Keyword Succeeds ${timeout} 2s Execute ONOS CLI Command ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-add-subscriber-access ${of_id} ${onu_port}
Sleep 10s
# Verify subscriber access flows are added for the ONU port
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Verify Subscriber Access Flows Added For ONU DT ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
... ${onu_port} ${nni_port} ${src['s_tag']}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Device ENABLED ACTIVE
... REACHABLE ${src['onu']} onu=True onu_reason=omci-flows-pushed
# TODO: Yet to Verify on the GPON based Physical POD (VOL-2652)
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds 60s 2s
... Check Ping True ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
Run Keyword and Ignore Error Get Device Output from Voltha ${onu_device_id}
Run Keyword and Ignore Error Collect Logs
END
# Verify ONOS Flows
# Number of Access Flows on ONOS equals 4 * the Number of Active ONUs (2 for each downstream and upstream)
${onos_flows_count}= Evaluate 4 * ${num_onus}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Verify Subscriber Access Flows Added Count DT ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... ${of_id} ${onos_flows_count}
# Verify VOLTHA Flows
# Number of per OLT Flows equals Twice the Number of Active ONUs (each for downstream and upstream) + 1 for LLDP
${olt_flows}= Evaluate 2 * ${num_onus} + 1
# Number of per ONU Flows equals 2 (one each for downstream and upstream)
${onu_flows}= Set Variable 2
Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Flows ${olt_flows}
${List_ONU_Serial} Create List
Set Suite Variable ${List_ONU_Serial}
Build ONU SN List ${List_ONU_Serial}
Log ${List_ONU_Serial}
Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate ONU Flows
... ${List_ONU_Serial} ${onu_flows}
Test Disable and Enable ONU for DT
[Documentation] Validates E2E Ping Connectivity and object states for the given scenario:
... Assuming that all the ONUs are DHCP/pingable (i.e. assuming sanityDt test was executed)
... Perform disable on the ONUs and validate that the pings do not succeed
... Perform enable on the ONUs and validate that the pings are successful
[Tags] functionalDt DisableEnableONUDt
[Setup] Run Keywords Announce Message START TEST DisableEnableONUDt
... AND Start Logging DisableEnableONUDt
[Teardown] Run Keywords Collect Logs
... AND Stop Logging DisableEnableONUDt
... AND Announce Message END TEST DisableEnableONUDt
FOR ${I} IN RANGE 0 ${num_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
${onu_device_id}= Get Device ID From SN ${src['onu']}
${onu_port}= Wait Until Keyword Succeeds ${timeout} 2s Get ONU Port in ONOS ${src['onu']}
... ${of_id}
Disable Device ${onu_device_id}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Device DISABLED UNKNOWN
... REACHABLE ${src['onu']} onu=True onu_reason=omci-admin-lock
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Verify ONU Port Is Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
# TODO: Yet to Verify on the GPON based Physical POD (VOL-2652)
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds 60s 2s
... Check Ping False ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
Sleep 5s
Enable Device ${onu_device_id}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Device ENABLED ACTIVE
... REACHABLE ${src['onu']} onu=True onu_reason=onu-reenabled
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Verify ONU Port Is Enabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
# TODO: Yet to Verify on the GPON based Physical POD (VOL-2652)
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds 60s 2s
... Check Ping True ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
Run Keyword and Ignore Error Get Device Output from Voltha ${onu_device_id}
Run Keyword and Ignore Error Collect Logs
END
Test Disable and Delete OLT for DT
[Documentation] Validates E2E Ping Connectivity and object states for the given scenario:
... Assuming that all the ONUs are DHCP/pingable (i.e. assuming sanityDt test was executed)
... Perform disable on the OLT and validate ONUs state and that the pings do not succeed
... Perform delete on the OLT, Re-do Setup (Recreate the OLT) and Perform Sanity Test DT
[Tags] functionalDt DisableDeleteOLTDt
[Setup] Run Keywords Announce Message START TEST DisableDeleteOLTDt
... AND Start Logging DisableDeleteOLTDt
[Teardown] Run Keywords Collect Logs
... AND Stop Logging DisableDeleteOLTDt
... AND Announce Message END TEST DisableDeleteOLTDt
# Disable and Validate OLT Device
Disable Device ${olt_device_id}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate OLT Device DISABLED UNKNOWN REACHABLE
... ${olt_serial_number}
# Validate ONUs
Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate ONUs After OLT Disable
# Verify ONOS Flows
# Number of Access Flows on ONOS equals 4 * the Number of Active ONUs (2 for each downstream and upstream)
${onos_flows_count}= Evaluate 4 * ${num_onus}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Verify Subscriber Access Flows Added Count DT ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... ${of_id} ${onos_flows_count}
# Verify VOLTHA Flows
# Number of per OLT Flows equals Twice the Number of Active ONUs (each for downstream and upstream) + 1 for LLDP
${olt_flows}= Evaluate 2 * ${num_onus} + 1
# Number of per ONU Flows equals 2 (one each for downstream and upstream)
${onu_flows}= Set Variable 2
Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Flows ${olt_flows}
${List_ONU_Serial} Create List
Set Suite Variable ${List_ONU_Serial}
Build ONU SN List ${List_ONU_Serial}
Log ${List_ONU_Serial}
Run Keyword Wait Until Keyword Succeeds ${timeout} 5s Validate ONU Flows
... ${List_ONU_Serial} ${onu_flows}
# Delete OLT and Validate Empty Device List
Delete Device ${olt_device_id}
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s Test Empty Device List
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Verify Device Flows Removed ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
Run Keyword and Ignore Error Collect Logs
# Re-do Setup (Recreate the OLT) and Perform Sanity Test DT
Run Keyword Setup
Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test DT
Run Keyword If ${has_dataplane} Clean Up Linux
*** Keywords ***
Setup Suite
[Documentation] Set up the test suite
Common Test Suite Setup
Clear All Devices Then Create New Device
[Documentation] Remove any devices from VOLTHA and ONOS
# Remove all devices from voltha and nos
Delete All Devices and Verify
# Execute normal test Setup Keyword
Setup