blob: 260d0ab1a1541eafc563a38a0d9685d2bea2c3d9 [file] [log] [blame]
# Copyright 2022 - present Open Networking Foundation
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
# FIXME Can we use the same test against BBSim and Hardware?
*** Settings ***
Suite Setup Setup Suite
Test Setup Setup
Test Teardown Teardown
Suite Teardown Teardown Suite
Library XML
Library String
Library DateTime
Library Process
Library Collections
Library RequestsLibrary
Library OperatingSystem
Resource ../../libraries/bbf_adapter_utilities.robot
Library ../../libraries/DependencyLibrary.py
Resource ../../libraries/onos.robot
Resource ../../libraries/voltctl.robot
Resource ../../libraries/voltha.robot
Resource ../../libraries/utils.robot
Resource ../../libraries/k8s.robot
Resource ../../variables/variables.robot
Resource ../../libraries/power_switch.robot
*** Variables ***
${POD_NAME} flex-ocp-cord
${KUBERNETES_CONF} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf
${KUBERNETES_CONFIGS_DIR} ~/pod-configs/kubernetes-configs
${KUBERNETES_YAML} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.yml
${HELM_CHARTS_DIR} ~/helm-charts
${VOLTHA_POD_NUM} 8
${NAMESPACE} voltha
${INFRA_NAMESPACE} default
${timeout} 60s
${of_id} 0
${logical_id} 0
${has_dataplane} False
${teardown_device} True
${scripts} ../../scripts
# Per-test logging on failure is turned off by default; set this variable to enable
${container_log_dir} ${None}
# logging flag to enable Collect Logs, can be passed via the command line too
# example: -v logging:False
${logging} True
# Flag specific to Soak Jobs
${SOAK_TEST} False
${bbsim_port} 50060
#Suppress the subscribe phase
${supress_add_subscriber} False
#Enable or Disable the MacLearning verifier for MacLearning ONOS APP
${maclearningenabled} False #Not yet used but it is a placeholder
*** Test Cases ***
BBF Adapter Aggregation Test
[Documentation] Do a runtime test enabling all the device
... and verify if VOLTHA and BBF have the same view,
... with the correct translation, of the network
[Tags] sanityBbfAdapter
[Setup] Start Logging sanityBbfAdapter
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging sanityBbfAdapter
Run Keyword Setup ${SOAK_TEST}
Run Keyword If ${has_dataplane} Clean Up Linux
Get BBF Device Aggregation ${NAMESPACE} ${CURDIR}/data.xml ${scripts}
Log ${supress_add_subscriber}
Perform Sanity Test of BBFadapter Aggregation ./data.xml ${supress_add_subscriber}
Teardown Suite
Test Disable and Enable ONU for BBF
[Documentation] Disable ONUs from the BBF Adapter (PlaceHolder with VOLTHA)
... Verify all the states in voltha and in the BBF Adapter (like a compare).
... Enable the ONUs from the BBF adapter, verify the enable states in voltha
... and in BBF Adapter (like a compare).
... It is also possible to verify a connectivity, with a no block test.
[Tags] bbfAdapterFunctionality disableEnableONUBBF
[Setup] Start Logging disableEnableONUBBF
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging disableEnableONUBBF
# Create a single Setup for Multiple Test Case
Run Keyword Setup ${SOAK_TEST}
Run Keyword If ${has_dataplane} Clean Up Linux
# Disable, verify state, Enable and verify stato for each ONU
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
${of_id}= Get ofID From OLT List ${src['olt']}
${onu_port}= Wait Until Keyword Succeeds ${timeout} 2s Get ONU Port in ONOS ${src['onu']}
... ${of_id} ${src['uni_id']}
${onu_device_id}= Get Device ID From SN ${src['onu']}
# Subscribe the ONU if requested for the tests
Run Keyword If '${supress_add_subscriber}' == 'False' Wait Until Keyword Succeeds ${timeout} 2s
... Execute ONOS CLI Command use single connection ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-add-subscriber-access ${of_id} ${onu_port}
# Disbale the device (actually with voltha in future with BBF Adapter)
Disable Device ${onu_device_id}
Disable Device in BBF ${onu_device_id}
# Retrive from BBF Adapter an Update XML that contain the ONUs
ONU XML update From BBF ${CURDIR}/data.xml ${scripts}
# Define some states that the ONU reason can be
${onu_reasons}= Create List omci-flows-deleted
Run Keyword If ${supress_add_subscriber} Append To List ${onu_reasons} omci-admin-lock
Log ${onu_reasons}
# Verify in Voltha the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Device DISABLED UNKNOWN
... REACHABLE ${src['onu']} onu=True onu_reason=${onu_reasons}
# Verify in the BBF Adapter the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Onu in BBF DISABLED UNKNOWN
... REACHABLE ${src['onu']} ${onu_reasons}
# Verify if the disabling of the ONU desable also the UNI port
Wait Until Keyword Succeeds ${timeout} 2s
... Verify UNI Port Is Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${src['onu']} ${src['uni_id']}
# Verify if there are not connectivity to the ONU
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds ${timeout} 2s
... Check Ping False ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
# Enable the device (actually with voltha in future with BBF Adapter)
Enable Device ${onu_device_id}
Enable Device in BBF ${onu_device_id}
# Retrive from BBF Adapter an Update XML that contain the ONUs
ONU XML update From BBF ${CURDIR}/data.xml ${scripts}
# Define some states that the ONU reason can be
${onu_reasons}= Create List omci-flows-pushed
Run Keyword If ${supress_add_subscriber} Append To List ${onu_reasons} onu-reenabled
Log ${onu_reasons}
# Verify in the Voltha the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Device ENABLED ACTIVE
... REACHABLE ${src['onu']} onu=True onu_reason=${onu_reasons}
# Verify in the BBF Adapter the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Onu in BBF ENABLED ACTIVE
... REACHABLE ${src['onu']} ${onu_reasons}
# Verify if the disabling of the ONU desable also the UNI port
Wait Until Keyword Succeeds ${timeout} 2s
... Verify UNI Port Is Enabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${src['onu']} ${src['uni_id']}
# Verify if there are not connectivity to the ONU
Run Keyword If ${has_dataplane} Run Keyword And Continue On Failure
... Wait Until Keyword Succeeds ${timeout} 2s
... Check Ping True ${dst['dp_iface_ip_qinq']} ${src['dp_iface_name']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
END
Test Disable and Enable OLT for BBF
[Documentation] Disable OLTs from the BBF Adapter (Placeholder with Voltha).
... Verify the disable states of OLTs in Voltha and in the BBF Adapter (like a compare).
... Enable the OLTs from the BBF adapter, verify the states in voltha
... and in BBF Adapter (like a compare).
... It is also possible to verify a connectivity, with a no block test.
[Tags] bbfAdapterFunctionality disableEnableOLTBBF
[Setup] Start Logging disableEnableOLTBBF
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging disableEnableOLTBBF
# Disable each OLT and Validate it state
FOR ${I} IN RANGE 0 ${olt_count}
${olt_serial_number}= Get From Dictionary ${olt_ids}[${I}] sn
${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
${of_id}= Get ofID From OLT List ${olt_serial_number}
# Retrive from BBF Adapter an Update XML that contain the ONUs
OLT XML update From BBF ${CURDIR}/data.xml ${scripts}
# Verify in Voltha the State of the OLT
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate OLT Device ENABLED ACTIVE REACHABLE
... ${olt_serial_number}
# Verify in BBF Adapter the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Olt in BBF ENABLED ACTIVE REACHABLE
... ${olt_serial_number} ${olt_device_id}
# Disbale the device (actually with voltha in future with BBF Adapter)
Disable Device ${olt_device_id}
Disable Device in BBF ${olt_device_id}
# Retrive from BBF Adapter an Update XML that contain the ONUs
OLT XML update From BBF ${CURDIR}/data.xml ${scripts}
# Verify in Voltha the State of the OLT
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate OLT Device DISABLED UNKNOWN REACHABLE
... ${olt_serial_number}
# Verify in BBF Adapter the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Olt in BBF DISABLED UNKNOWN REACHABLE
... ${olt_serial_number} ${olt_device_id}
END
# Enable the OLT back and check OLT operstatus are back to "ACTIVE"
FOR ${I} IN RANGE 0 ${olt_count}
${olt_serial_number}= Get From Dictionary ${olt_ids}[${I}] sn
${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
${of_id}= Get ofID From OLT List ${olt_serial_number}
# Enable the device (actually with voltha in future with BBF Adapter)
Enable Device ${olt_device_id}
Enable Device in BBF ${olt_device_id}
# Retrive from BBF Adapter an Update XML that contain the ONUs
OLT XML update From BBF ${CURDIR}/data.xml ${scripts}
# Verify in Voltha the State of the OLT
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate OLT Device ENABLED ACTIVE REACHABLE
... ${olt_serial_number}
# Verify in BBF Adapter the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Olt in BBF ENABLED ACTIVE REACHABLE
... ${olt_serial_number} ${olt_device_id}
END
Test Disable and Delete OLT for BBF
[Documentation] Disable OLTs from the BBF Adapter (PlaceHolder with Voltha)
... Verify the disable state of the OLT in voltha and in the BBF Adapter,
... Delete the OLTs from the BBF adapter, verify if it was done correctly in voltha
... and in BBF Adapter.
[Tags] bbfAdapterFunctionality disableEnableOLTBBF
[Setup] Start Logging disableEnableOLTBBF
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging disableEnableOLTBBF
# Disable and Validate OLT Device
FOR ${I} IN RANGE 0 ${olt_count}
${olt_serial_number}= Get From Dictionary ${olt_ids}[${I}] sn
${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
Disable Device ${olt_device_id}
Disable Device in BBF ${olt_device_id}
${of_id}= Get ofID From OLT List ${olt_serial_number}
# Retrive from BBF Adapter an Update XML that contain the ONUs
ONU XML update From BBF ${CURDIR}/data.xml ${scripts}
# Retrive from BBF Adapter an Update XML that contain the ONUs
OLT XML update From BBF ${CURDIR}/data.xml ${scripts}
# Retrive from BBF Adapter an Update XML that contain all the devices
ALL DEVICES XML update From BBF ${CURDIR}/data.xml ${scripts}
# Verify in Voltha the State of the OLT
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate OLT Device DISABLED UNKNOWN REACHABLE
... ${olt_serial_number}
Validate Olt Disabled in BBF ${olt_serial_number} ${olt_device_id}
${num_onus}= Set Variable ${list_olts}[${I}][onucount]
# Validate ONUs
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate ONUs After OLT Disable
... ${num_onus} ${olt_serial_number}
Validate ONUs After OLT Disable in BBF ${olt_serial_number}
# Delete the device (actually with voltha in future with BBF Adapter)
Delete Device ${olt_device_id}
Delete Device in BBF ${olt_device_id}
# Retrive from BBF Adapter an Update XML that contain all the devices
ALL DEVICES XML update From BBF ${CURDIR}/data.xml ${scripts}
# Check that the OLT are actually removed from the system
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s Validate Device Removed
... ${olt_serial_number}
# Check if the OLT has been removed from the system
Validate Device Removed in BBF ${olt_serial_number}
# Validate if all the ONUS connected at the OLT revomed are also been removed in VOLTHA
Run Keyword and Continue On Failure Validate all ONUS for OLT Removed ${num_all_onus} ${hosts}
... ${olt_serial_number} ${timeout}
# Validate if all the ONUS connected at the OLT revomed are also been removed in BBF Adapter
Validate All Onus for OLT Removed in BBF ${olt_serial_number}
#Wait Until Keyword Succeeds ${timeout} 5s
#... Verify Device Flows Removed ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
END
Teardown Suite
Test Delete and ReAdd OLT for BBF
[Documentation] Delete OLTs from the BBF Adapter (PlaceHolder with Voltha)
... Verify if the OLT and ONUs connected was really delete in voltha and in the BBF Adapter.
... Readd all the OLTs from the BBF adapter, verify the enable state in voltha
... and in BBF Adapter and check the correct status after the readd.
[Tags] bbfAdapterFunctionality DeleteReAddOLTBBF
[Setup] Start Logging DeleteReAddOLTBBF
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging DeleteReAddOLTBBF
Run Keyword Setup ${SOAK_TEST}
Run Keyword If ${has_dataplane} Clean Up Linux
FOR ${I} IN RANGE 0 ${olt_count}
${olt_serial_number}= Get From Dictionary ${olt_ids}[${I}] sn
${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
# Delete the device (actually with voltha in future with BBF Adapter)
Delete Device ${olt_device_id}
Delete Device in BBF ${olt_device_id}
# Retrive from BBF Adapter an Update XML that contain all the devices
ALL DEVICES XML update From BBF ${CURDIR}/data.xml ${scripts}
# Check if the OLT has been removed from the system
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Device Removed ${olt_serial_number}
# Check if the OLT has been removed from the BBF Adapter
Validate Device Removed in BBF ${olt_serial_number}
# Validate if all the ONUS connected at the OLT revomed are also been removed in VOLTHA
Run Keyword and Continue On Failure Validate all ONUS for OLT Removed ${num_all_onus} ${hosts}
... ${olt_serial_number} ${timeout}
# Validate if all the ONUS connected at the OLT revomed are also been removed in BBF Adapter
Validate all ONUS for OLT Removed in BBF ${olt_serial_number}
#Wait Until Keyword Succeeds ${timeout} 5s
#... Verify Device Flows Removed ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
END
# Recreate the OLTs
Run Keyword Setup ${SOAK_TEST}
# Retrive from BBF Adapter an Update XML that contain the ONUs
OLT XML update From BBF ${CURDIR}/data.xml ${scripts}
FOR ${I} IN RANGE 0 ${olt_count}
${olt_serial_number}= Get From Dictionary ${olt_ids}[${I}] sn
${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
# Verify in Voltha the State of the OLT
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate OLT Device ENABLED ACTIVE REACHABLE
... ${olt_serial_number}
# Verify in BBF Adapter the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Olt in BBF ENABLED ACTIVE REACHABLE
... ${olt_serial_number} ${olt_device_id}
END
Teardown Suite
Test Disable ONUs and OLT for BBF
[Documentation] Disable ONUs and OLTs, verify if the OLT and ONUs connected
... was really disable in voltha and in the BBF Adapter.
... Delete ONUs and OLTs, verify if the ONUs and OLT was really deleted
... in voltha and BBF Adapter.
[Tags] bbfAdapterFunctionality DisableONUOLTBBF
[Setup] Start Logging DisableONUOLTBBF
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging DisableONUOLTBBF
Run Keyword Setup ${SOAK_TEST}
Run Keyword If ${has_dataplane} Clean Up Linux
# Define some states that the ONU reason can be
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
${onu_device_id}= Get Device ID From SN ${src['onu']}
${of_id}= Get ofID From OLT List ${src['olt']}
${onu_port}= Wait Until Keyword Succeeds ${timeout} 2s
... Get ONU Port in ONOS ${src['onu']} ${of_id} ${src['uni_id']}
${olt_device_id}= Get OLTDeviceID From OLT List ${src['olt']}
# Subscribe the ONU if requested for the tests
Run Keyword If '${supress_add_subscriber}' == 'False' Wait Until Keyword Succeeds ${timeout} 2s
... Execute ONOS CLI Command use single connection ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-add-subscriber-access ${of_id} ${onu_port}
# Onu reasons selection
@{onu_reasons}= Create List omci-flows-pushed
Run Keyword If ${supress_add_subscriber} Append To List ${onu_reasons} initial-mib-downloaded
# Retrive from BBF Adapter an Update XML that contain the ONUs
ONU XML update From BBF ${CURDIR}/data.xml ${scripts}
# Verify in the Voltha the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Device ENABLED ACTIVE
... REACHABLE ${src['onu']} onu=True onu_reason=${onu_reasons}
# Verify in the BBF Adapter the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Onu in BBF ENABLED ACTIVE
... REACHABLE ${src['onu']} ${onu_reasons}
# Retrive from BBF Adapter an Update XML that contain the ONUs
OLT XML update From BBF ${CURDIR}/data.xml ${scripts}
# Verify in Voltha the State of the OLT
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate OLT Device ENABLED ACTIVE
... REACHABLE ${src['olt']}
# Verify in BBF Adapter the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Olt in BBF ENABLED ACTIVE REACHABLE
... ${src['olt']} ${olt_device_id}
# Disbale the device (actually with voltha in future with BBF Adapter)
Disable Device ${onu_device_id}
Disable Device in BBF ${onu_device_id}
# Onu reasons selection
${onu_reasons}= Create List omci-flows-deleted
Run Keyword If ${supress_add_subscriber} Append To List ${onu_reasons} omci-admin-lock
Log ${onu_reasons}
# Retrive from BBF Adapter an Update XML that contain the ONUs
ONU XML update From BBF ${CURDIR}/data.xml ${scripts}
# Verify in the Voltha the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Device DISABLED UNKNOWN
... REACHABLE ${src['onu']} ${onu_reasons} onu=True
# Verify in the BBF Adapter the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Onu in BBF DISABLED UNKNOWN
... REACHABLE ${src['onu']} ${onu_reasons}
# Check if the OLT where the ONU is connected have the correct state
# after the disbaling one ONU connected
# Retrive from BBF Adapter an Update XML that contain the ONUs
OLT XML update From BBF ${CURDIR}/data.xml ${scripts}
# Verify in Voltha the State of the OLT
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate OLT Device ENABLED ACTIVE
... REACHABLE ${src['olt']}
# Verify in BBF Adapter the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Olt in BBF ENABLED ACTIVE REACHABLE
... ${src['olt']} ${olt_device_id}
END
# Disable all OLTs and check if the state after disable are correct
FOR ${I} IN RANGE 0 ${olt_count}
${olt_serial_number}= Get From Dictionary ${olt_ids}[${I}] sn
${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
Disable Device ${olt_device_id}
Disable Device in BBF ${olt_device_id}
# Retrive from BBF Adapter an Update XML that contain the ONUs
OLT XML update From BBF ${CURDIR}/data.xml ${scripts}
# Verify in Voltha the State of the OLT
Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Device DISABLED UNKNOWN REACHABLE
... ${olt_serial_number}
# Verify in BBF Adapter the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Olt in BBF DISABLED UNKNOWN REACHABLE
... ${olt_serial_number} ${olt_device_id}
END
Delete Disabled ONUs and OLT for BBF
[Documentation] Continue of the before test.
... Validate the Disble state of ONUs and Oltes,
... Delete Disabled Onus and Disabled Olts and verify the correct
... elimination of all devices from Voltha and BBF Adapter.
[Tags] bbfAdapterFunctionality DeleteONUOLTBBF
[Setup] Start Logging DeleteONUOLTBBF
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging DeleteONUOLTBBF
# Validate ONUs states after OLT disable
${onu_reasons}= Create List stopping-openomci
Run Keyword If ${supress_add_subscriber} Append To List ${onu_reasons} stopping-openomci
Log ${onu_reasons}
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
${onu_device_id}= Get Device ID From SN ${src['onu']}
${olt_device_id}= Get OLTDeviceID From OLT List ${src['olt']}
# Retrive from BBF Adapter an Update XML that contain the ONUs
ONU XML update From BBF ${CURDIR}/data.xml ${scripts}
# Verify in the Voltha the State of the ONU
Wait Until Keyword Succeeds ${timeout} 5s
... Validate Device DISABLED DISCOVERED
... UNREACHABLE ${src['onu']} ${onu_reasons} onu=True
# Verify in the BBF Adapter the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Onu in BBF DISABLED DISCOVERED
... UNREACHABLE ${src['onu']} ${onu_reasons}
# Delete the device (actually with voltha in future with BBF Adapter)
Delete Device ${onu_device_id}
Delete Device in BBF ${onu_device_id}
# Retrive from BBF Adapter an Update XML that contain all the devices
ALL DEVICES XML update From BBF ${CURDIR}/data.xml ${scripts}
Validate Device Removed in BBF ${src['onu']}
# Retrive from BBF Adapter an Update XML that contain the ONUs
OLT XML update From BBF ${CURDIR}/data.xml ${scripts}
# Verify in Voltha the State of the OLT
Wait Until Keyword Succeeds ${timeout} 5s
... Validate OLT Device DISABLED UNKNOWN
... REACHABLE ${src['olt']}
# Verify in BBF Adapter the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
... Validate Olt in BBF DISABLED UNKNOWN REACHABLE
... ${src['olt']} ${olt_device_id}
END
# Delete all OLTs
# Delete All Devices and Verify
FOR ${I} IN RANGE 0 ${olt_count}
${olt_serial_number}= Get From Dictionary ${olt_ids}[${I}] sn
${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
# Delete the device (actually with voltha in future with BBF Adapter)
Delete Device ${olt_device_id}
Delete Device in BBF ${olt_device_id}
# Retrive from BBF Adapter an Update XML that contain all the devices
ALL DEVICES XML update From BBF ${CURDIR}/data.xml ${scripts}
# Check that the OLT and the ONUs are actually removed from the system
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s Validate Device Removed
... ${olt_serial_number}
# Check if the OLT has been removed from the system
Validate Device Removed in BBF ${olt_serial_number}
# Validate if all the ONUS connected at the OLT revomed are also been removed in VOLTHA
Run Keyword and Continue On Failure Validate all ONUS for OLT Removed ${num_all_onus} ${hosts}
... ${olt_serial_number} ${timeout}
# Validate if all the ONUS connected at the OLT revomed are also been removed in BBF Adapter
Validate all ONUS for OLT Removed in BBF ${olt_serial_number}
#Wait Until Keyword Succeeds ${timeout} 5s
#... Verify Device Flows Removed ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
END
Teardown Suite
Test ONU Delete and Auto-Discovery for BBF
[Documentation] Validate the Autodiscory of an ONUs in case of Delete.
... Delete the device and verify if them was really deleted.
... Verify if all the Onus are re discovered in the correct way.
... Verify the state after and before a subscription if needed.
... Verify the connectivity if needed.
[Tags] bbfAdapterFunctionality ONUAutoDiscoveryBBF
[Setup] Start Logging ONUAutoDiscoveryBBF
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging ONUAutoDiscoveryBBF
Clear All Devices Then Create New Device
# Performing Sanity Test to make sure subscribers are all AUTH+DHCP and pingable
Run Keyword If ${has_dataplane} Clean Up Linux
FOR ${I} IN RANGE 0 ${num_all_onus}
${src}= Set Variable ${hosts.src[${I}]}
${dst}= Set Variable ${hosts.dst[${I}]}
${of_id}= Get ofID From OLT List ${src['olt']}
${onu_port}= Wait Until Keyword Succeeds ${timeout} 2s
... Get ONU Port in ONOS ${src['onu']} ${of_id}
${onu_device_id}= Get Device ID From SN ${src['onu']}
${nni_port}= Wait Until Keyword Succeeds ${timeout} 2s Get NNI Port in ONOS ${of_id}
# Subscribe the ONU if requested for the tests
Run Keyword If '${supress_add_subscriber}' == 'False' Wait Until Keyword Succeeds ${timeout} 2s
... Execute ONOS CLI Command use single connection ${ONOS_SSH_IP}
... ${ONOS_SSH_PORT} volt-add-subscriber-access ${of_id} ${onu_port}
# Verify ONU state in voltha
# Retrive from BBF Adapter an Update XML that contain the ONUs
ONU XML update From BBF ${CURDIR}/data.xml ${scripts}
@{onu_reasons}= Create List omci-flows-pushed
Run Keyword If ${supress_add_subscriber} Append To List ${onu_reasons} initial-mib-downloaded
# Verify in the Voltha the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Validate Device ENABLED ACTIVE REACHABLE
... ${src['onu']} onu=True onu_reason=${onu_reasons}
# Verify in the BBF Adapter the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Validate Onu in BBF ENABLED ACTIVE
... REACHABLE ${src['onu']} ${onu_reasons}
# Delete ONU and Verify Ping Fails
# Delete the device (actually with voltha in future with BBF Adapter)
Delete Device ${onu_device_id}
Delete Device in BBF ${onu_device_id}
# Retrive from BBF Adapter an Update XML that contain all the devices
ALL DEVICES XML update From BBF ${CURDIR}/data.xml ${scripts}
# Verify if the ONU has been removed from the system
Validate Device Removed in BBF ${src['onu']}
Run Keyword If ${has_dataplane} Verify ping is successful except for given device
... ${num_all_onus} ${src['onu']}
# Verify that no pending flows exist for the ONU port
Wait Until Keyword Succeeds ${timeout} 2s
... Verify No Pending Flows For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
# ONU Auto-Discovery
${onu_port}= Wait Until Keyword Succeeds ${timeout} 2s
... Get ONU Port in ONOS ${src['onu']} ${of_id} ${src['uni_id']}
# Check ONU port is Enabled in ONOS
Wait Until Keyword Succeeds ${timeout} 2s
... Verify UNI Port Is Enabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${src['onu']} ${src['uni_id']}
${onu_device_id}= Get Device ID From SN ${src['onu']}
Run Keyword If ${has_dataplane} Clean Up Linux ${onu_device_id}
# Re-Add Subscriber
Run Keyword If '${supress_add_subscriber}' == 'False' Wait Until Keyword Succeeds ${timeout} 2s
... Execute ONOS CLI Command use single connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
... volt-add-subscriber-access ${of_id} ${onu_port}
# Verify that no pending flows exist for the ONU port
Wait Until Keyword Succeeds ${timeout} 2s
... Verify No Pending Flows For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${onu_port}
# Verify ONU state in voltha
# Retrive from BBF Adapter an Update XML that contain the ONUs
ONU XML update From BBF ${CURDIR}/data.xml ${scripts}
@{onu_reasons}= Create List omci-flows-pushed
Run Keyword If ${supress_add_subscriber} Append To List ${onu_reasons} initial-mib-downloaded
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Validate Device ENABLED ACTIVE REACHABLE
... ${src['onu']} onu=True onu_reason=${onu_reasons}
# Verify in the BBF Adapter the State of the ONU
Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
... Validate Onu in BBF ENABLED ACTIVE
... REACHABLE ${src['onu']} ${onu_reasons}
# Verify Meters in ONOS
#Wait Until Keyword Succeeds ${timeout} 5s
#... Verify Meters in ONOS Ietf ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id} ${onu_port}
Run Keyword If ${has_dataplane} Validate DHCP and Ping True
... True ${src['dp_iface_name']} ${src['s_tag']} ${src['c_tag']} ${dst['dp_iface_ip_qinq']}
... ${src['ip']} ${src['user']} ${src['pass']} ${src['container_type']} ${src['container_name']}
... ${dst['dp_iface_name']} ${dst['ip']} ${dst['user']} ${dst['pass']} ${dst['container_type']}
... ${dst['container_name']}
END
# Verify flows for all OLTs
#Wait Until Keyword Succeeds ${timeout} 5s Validate All OLT Flows
*** Keywords ***
Setup Suite
[Documentation] Set up the test suite
Common Test Suite Setup
#power_switch.robot needs it to support different vendor's power switch
${switch_type}= Get Variable Value ${web_power_switch.type}
Run Keyword If "${switch_type}"!="" Set Global Variable ${powerswitch_type} ${switch_type}
Clear All Devices Then Create New Device
[Documentation] Remove any devices from VOLTHA and ONOS
# Remove all devices from voltha and nos
Run Keyword Delete All Devices and Verify
# Execute normal test Setup Keyword
Run Keyword Setup ${SOAK_TEST}