*** Settings ***
Documentation Negative test states of ONU Go adapter with ATT workflows only (not for DT/TT workflow!)
Suite Setup Setup Suite
Suite Teardown Teardown Suite
Test Setup Setup
Test Teardown Teardown
Library Collections
Library String
Library OperatingSystem
Library XML
Library RequestsLibrary
Library ../../libraries/DependencyLibrary.py
Resource ../../libraries/onos.robot
Resource ../../libraries/voltctl.robot
Resource ../../libraries/voltha.robot
Resource ../../libraries/utils.robot
Resource ../../libraries/k8s.robot
Resource ../../libraries/onu_utilities.robot
Resource ../../libraries/bbsim.robot
Resource ../../variables/variables.robot
*** Variables ***
${NAMESPACE} voltha
${INFRA_NAMESPACE} default
${timeout} 300s
${of_id} 0
${logical_id} 0
${has_dataplane} True
${external_libs} True
${teardown_device} True
${scripts} ../../scripts
# Per-test logging on failure is turned off by default; set this variable to enable
${container_log_dir} ${None}
# KV Store Prefix
# example: -v kvstoreprefix:voltha_voltha
${kvstoreprefix} voltha_voltha
# used tech profile, can be passed via the command line too, valid values: default (=1T1GEM), 1T4GEM, 1T8GEM
# example: -v techprofile:1T4GEM
${techprofile} default
# flag debugmode is used, if true timeout calculation various, can be passed via the command line too
# example: -v debugmode:True
${debugmode} False
# logging flag to enable Collect Logs, can be passed via the command line too
# example: -v logging:True
${logging} False
# if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline!
# example: -v pausebeforecleanup:True
${pausebeforecleanup} False
# if True some outputs to console are done during running tests e.g. long duration flow test
# example: -v print2console:True
${print2console} False
${data_dir} ../data
*** Test Cases ***
ONU Negative State Test
[Documentation] Validates the ONU Go adapter states will never leave starting-openomci
... Due to a 'omci-response-rate' lower than 8 more OMCI messages will be through away by BBSIM than
... repeated by openonu-go-adapter. So ONU will never leave starting-openomci state.
... Timeout has to set at least to 300s (or more)
[Tags] NegativeStateTestOnuGo
[Setup] Run Keywords Start Logging ONUNegativeStateTest
... AND Setup
# Suite Variable will be overwritten by Teardown of Current State Test All Onus
Set Suite Variable ${StateTestAllONUs} True
${seconds}= Convert Time ${timeout}
${seconds}= Convert To String ${seconds}
${seconds}= Get Substring ${seconds} 0 -2
FOR ${I} IN RANGE ${seconds}
Sleep 1s
Current State Test All Onus starting-openomci timeout=1x
Exit For Loop If not ${StateTestAllONUs}
END
[Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
... AND Stop Logging ONUStateTest
*** Keywords ***
Setup Suite
[Documentation] Set up the test suite
Start Logging Setup or Teardown Setup-${SUITE NAME}
${LogInfo}= Catenate
... \r\nPassed arguments:
... techprofile:${techprofile},
... debugmode:${debugmode}, logging:${logging}, pausebeforecleanup:${pausebeforecleanup},
... print2console:${print2console}
Log ${LogInfo} console=yes
Common Test Suite Setup
${techprofile}= Set Variable If "${techprofile}"=="1T1GEM" default ${techprofile}
Set Suite Variable ${techprofile}
Run Keyword If "${techprofile}"=="default" Log To Console \nTechProfile:default (1T1GEM)
... ELSE IF "${techprofile}"=="1T4GEM" Set Tech Profile 1T4GEM ${INFRA_NAMESPACE}
... ELSE IF "${techprofile}"=="1T8GEM" Set Tech Profile 1T8GEM ${INFRA_NAMESPACE}
... ELSE Fail The TechProfile (${techprofile}) is not valid!
# delete etcd MIB Template Data
Delete MIB Template Data ${INFRA_NAMESPACE}
# delete etcd onu data
Delete ONU Go Adapter ETCD Data namespace=${INFRA_NAMESPACE} validate=True
Run Keyword If ${logging} Collect Logs
Stop Logging Setup or Teardown Setup-${SUITE NAME}
Teardown Suite
[Documentation] Replaces the Suite Teardown in utils.robot.
... Cleans up and checks all ONU ports disabled in ONOS.
... Furthermore gives the possibility to pause the execution.
Start Logging Setup or Teardown Teardown-${SUITE NAME}
Run Keyword If ${pausebeforecleanup} Import Library Dialogs
Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up!
Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes
Run Keyword If ${teardown_device} Delete All Devices and Verify
Wait Until Keyword Succeeds ${timeout} 1s Validate Onu Data In Etcd ${INFRA_NAMESPACE} 0 ${kvstoreprefix}
... without_pm_data=False
Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} 0 BBSM ${timeout}
Run Keyword If ${logging} Collect Logs
Stop Logging Setup or Teardown Teardown-${SUITE NAME}
Close All ONOS SSH Connections
Remove Tech Profile ${INFRA_NAMESPACE}