| # Copyright 2017 - present Open Networking Foundation |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| # FIXME Can we use the same test against BBSim and Hardware? |
| |
| *** Settings *** |
| Documentation Test various functional end-to-end scenarios for TT workflow |
| Suite Setup Setup Suite |
| Test Setup Setup |
| Test Teardown Teardown |
| Suite Teardown Teardown Suite |
| Library Collections |
| Library String |
| Library OperatingSystem |
| Library XML |
| Library RequestsLibrary |
| Library ../../libraries/DependencyLibrary.py |
| Resource ../../libraries/onos.robot |
| Resource ../../libraries/voltctl.robot |
| Resource ../../libraries/voltha.robot |
| Resource ../../libraries/utils.robot |
| Resource ../../libraries/k8s.robot |
| Resource ../../variables/variables.robot |
| Resource ../../libraries/power_switch.robot |
| |
| *** Variables *** |
| ${POD_NAME} flex-ocp-cord |
| ${KUBERNETES_CONF} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf |
| ${KUBERNETES_CONFIGS_DIR} ~/pod-configs/kubernetes-configs |
| #${KUBERNETES_CONFIGS_DIR} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf |
| ${KUBERNETES_YAML} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.yml |
| ${HELM_CHARTS_DIR} ~/helm-charts |
| ${VOLTHA_POD_NUM} 8 |
| ${NAMESPACE} voltha |
| # For below variable value, using deployment name as using grep for |
| # parsing radius pod name, we can also use full radius pod name |
| ${RESTART_POD_NAME} radius |
| ${timeout} 60s |
| ${of_id} 0 |
| ${logical_id} 0 |
| ${has_dataplane} True |
| ${teardown_device} False |
| ${scripts} ../../scripts |
| |
| # Per-test logging on failure is turned off by default; set this variable to enable |
| ${container_log_dir} ${None} |
| |
| *** Test Cases *** |
| Reboot TT ONUs Physically - Clean Up |
| [Documentation] This test reboots ONUs physically before execution all the tests |
| ... Test case runs only on the PODs that are configured with PowerSwitch that |
| ... controls the power off/on ONUs/OLT remotely (simulating a physical reboot) |
| [Tags] functional PowerSwitch RebootAllTTONUs |
| [Setup] Start Logging RebootAllTTONUs |
| [Teardown] Run Keywords Collect Logs |
| ... AND Stop Logging RebootAllTTONUs |
| Power Switch Connection Suite ${web_power_switch.ip} ${web_power_switch.user} ${web_power_switch.password} |
| FOR ${I} IN RANGE 0 ${num_onus} |
| ${src}= Set Variable ${hosts.src[${I}]} |
| ${dst}= Set Variable ${hosts.dst[${I}]} |
| Disable Switch Outlet ${src['power_switch_port']} |
| Sleep 60s |
| Enable Switch Outlet ${src['power_switch_port']} |
| Sleep 60s |
| END |
| |
| Sanity E2E Test for TT (HSIA, VoD, VoIP) |
| [Documentation] Validates E2E Ping Connectivity and object states for the given scenario: |
| ... Validate successful DHCP/E2E ping (no EAPOL and DHCP flows) for the tech profile that is used |
| ... Traffic sent with same vlan from different RGs, |
| ... should reach the NNI port on the OLT with the expected double tagged vlan ids |
| ... Inner vlans from the RG should not change |
| [Tags] sanityTT |
| [Setup] Run Keywords Start Logging SanityTestTT |
| ... AND Setup |
| [Teardown] Run Keywords Collect Logs |
| ... AND Stop Logging SanityTestTT |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test TT |
| #Run Keyword If ${has_dataplane} Clean Up Linux |
| |
| Sanity E2E Test for TT (MCAST) |
| [Documentation] Validates E2E Ping Connectivity and object states for the given scenario: |
| ... Validate successful DHCP/E2E ping (no EAPOL and DHCP flows) for the tech profile that is used |
| ... Traffic sent with same vlan from different RGs, |
| ... should reach the NNI port on the OLT with the expected double tagged vlan ids |
| ... Inner vlans from the RG should not change |
| [Tags] sanityTT-MCAST |
| [Setup] Run Keyword Start Logging SanityTestTT-MCAST |
| [Teardown] Run Keywords Collect Logs |
| ... AND Stop Logging SanityTestTT-MCAST |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test TT MCAST |
| |
| *** Keywords *** |
| Setup Suite |
| [Documentation] Set up the test suite |
| Common Test Suite Setup |
| ${switch_type}= Get Variable Value ${web_power_switch.type} |
| Run Keyword If "${switch_type}"!="" Set Global Variable ${powerswitch_type} ${switch_type} |
| |
| |
| Clear All Devices Then Create New Device |
| [Documentation] Remove any devices from VOLTHA and ONOS |
| # Remove all devices from voltha and nos |
| Delete All Devices and Verify |
| # Execute normal test Setup Keyword |
| Setup |
| |
| |
| Teardown Suite |
| [Documentation] Tear down steps for the suite |
| Run Keyword If ${has_dataplane} Clean Up Linux |