| # Copyright 2022 - present Open Networking Foundation |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| |
| *** Settings *** |
| Documentation Test of try to catch memory leak in voltha components. |
| Suite Setup Setup Suite |
| Suite Teardown Teardown Suite |
| Test Setup Setup |
| Test Teardown Teardown |
| Library Collections |
| Library String |
| Library OperatingSystem |
| Library XML |
| Library RequestsLibrary |
| Library ../../libraries/DependencyLibrary.py |
| Resource ../../libraries/onos.robot |
| Resource ../../libraries/voltctl.robot |
| Resource ../../libraries/voltha.robot |
| Resource ../../libraries/utils.robot |
| Resource ../../libraries/k8s.robot |
| Resource ../../libraries/onu_utilities.robot |
| Resource ../../variables/variables.robot |
| |
| *** Variables *** |
| ${NAMESPACE} voltha |
| ${INFRA_NAMESPACE} default |
| ${timeout} 60s |
| ${of_id} 0 |
| ${logical_id} 0 |
| ${has_dataplane} True |
| ${external_libs} True |
| ${teardown_device} True |
| ${scripts} ../../scripts |
| # Per-test logging on failure is turned off by default; set this variable to enable |
| ${container_log_dir} ${None} |
| # determines the environment workflow: DT, TT or ATT (default) |
| # example: -v workflow:DT |
| ${workflow} ATT |
| # KV Store Prefix |
| # example: -v kvstoreprefix:voltha/voltha_voltha |
| ${kvstoreprefix} voltha/voltha_voltha |
| # flag debugmode is used, if true timeout calculation various, can be passed via the command line too |
| # example: -v debugmode:True |
| ${debugmode} False |
| # logging flag to enable Collect Logs, can be passed via the command line too |
| # example: -v logging:True |
| ${logging} False |
| # if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline! |
| # example: -v pausebeforecleanup:True |
| ${pausebeforecleanup} False |
| # if True some outputs to console are done during running tests e.g. long duration flow test |
| # example: -v print2console:True |
| ${print2console} False |
| # if True etcd check will be executed in test case teardown, if False etcd check will be executed in suite teardown |
| # example: -v etcdcheckintestteardown:False |
| ${etcdcheckintestteardown} True |
| ${data_dir} ../data |
| # number of iterations |
| # example: -v iterations:10 |
| ${iterations} 200 |
| |
| # flag to choose the subscriber provisioning command type in ONOS |
| # TT often provision a single services for a subscriber (eg: hsia, voip, ...) one after the other. |
| # if set to True, command used is "volt-add-subscriber-unitag" |
| # if set to False, comand used is "volt-add-subscriber-access" |
| ${unitag_sub} False |
| |
| *** Test Cases *** |
| Memory Leak Test Openonu Go Adapter |
| [Documentation] Test of try to catch memory leak in Openonu Go Adapter for all three workflows, ATT, DT and TT |
| ... Multiple run of Flow and ONU setup and teardown to try to catch memory leak. |
| ... - do workflow related sanity test (bring up onu to omci flows pushed and setup flows) |
| ... - remove flows |
| ... - delete ONU devices |
| ... - wait for onu auto detect |
| [Tags] functionalMemoryLeak MemoryLeakTestOnuGo |
| [Setup] Run Keywords Start Logging MemoryLeakTestOnuGo |
| ... AND Setup |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| Run Keyword If ${print2console} Log \r\nStart ${iterations} iterations. console=yes |
| FOR ${I} IN RANGE 1 ${iterations} + 1 |
| Run Keyword If ${print2console} Log \r\nStart iteration ${I} of ${iterations}. console=yes |
| Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT |
| ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT |
| ... ELSE Perform Sanity Test |
| Sleep 5s |
| Run Keyword If ${print2console} Log Remove Flows. console=yes |
| Remove Flows all ONUs |
| Run Keyword If ${print2console} Log Check Flows removed. console=yes |
| Check All Flows Removed |
| Run Keyword If ${print2console} Log Get ONU Device IDs. console=yes |
| ${onu_device_id_list}= Get ONUs Device IDs from Voltha |
| Run Keyword If ${print2console} Log Delete ONUs. console=yes |
| Delete Devices In Voltha Type=brcm_openomci_onu |
| Run Keyword If ${print2console} Log Wait for ONUs come back. console=yes |
| Wait Until Keyword Succeeds ${timeout} 1s Check for new ONU Device IDs ${onu_device_id_list} |
| ${list_onus} Create List |
| Build ONU SN List ${list_onus} |
| Wait Until Keyword Succeeds ${timeout} 1s Check all ONU OperStatus ${list_onus} ACTIVE |
| Build ONU SN List ${list_onus} |
| ${onu_reason}= Set Variable If "${workflow}"=="DT" initial-mib-downloaded |
| ... "${workflow}"=="TT" initial-mib-downloaded |
| ... "${workflow}"=="ATT" omci-flows-pushed |
| Wait Until Keyword Succeeds ${timeout} 1s Validate ONU Devices ENABLED ACTIVE REACHABLE |
| ... ${list_onus} onu_reason=${onu_reason} |
| Run Keyword If ${print2console} Log End iteration ${I} of ${iterations}. console=yes |
| END |
| [Teardown] Run Keywords Printout ONU Serial Number and Device Id print2console=${print2console} |
| ... AND Run Keyword If ${logging} Get Logical Id of OLT |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Teardown Test |
| ... AND Stop Logging MemoryLeakTestOnuGo |
| |
| *** Keywords *** |
| Setup Suite |
| [Documentation] Set up the test suite |
| Start Logging Setup or Teardown Setup-${SUITE NAME} |
| ${LogInfo}= Catenate |
| ... \r\nPassed arguments: |
| ... debugmode:${debugmode}, logging:${logging}, pausebeforecleanup:${pausebeforecleanup}, |
| ... print2console:${print2console}, workflow:${workflow}, kvstoreprefix:${kvstoreprefix}, |
| ... iterations:${iterations} |
| Log ${LogInfo} console=yes |
| Common Test Suite Setup |
| # set tech profiles |
| ${preload_tech_profile}= Set Variable If ${unitag_sub} and "${workflow}"=="TT" and not ${has_dataplane} True False |
| Set Suite Variable ${preload_tech_profile} |
| Run Keyword If ${preload_tech_profile} Set Tech Profile TT-HSIA ${INFRA_NAMESPACE} 64 |
| Run Keyword If ${preload_tech_profile} Set Tech Profile TT-VoIP ${INFRA_NAMESPACE} 65 |
| Run Keyword If ${preload_tech_profile} Set Tech Profile TT-multi-uni-MCAST-AdditionalBW-None ${INFRA_NAMESPACE} 66 |
| # delete etcd MIB Template Data |
| Delete MIB Template Data ${INFRA_NAMESPACE} |
| # delete etcd onu data |
| Delete ONU Go Adapter ETCD Data namespace=${INFRA_NAMESPACE} validate=True |
| Run Keyword If ${logging} Collect Logs |
| Stop Logging Setup or Teardown Setup-${SUITE NAME} |
| |
| |
| Teardown Suite |
| [Documentation] Replaces the Suite Teardown in utils.robot. |
| ... Cleans up and checks all ONU ports disabled in ONOS. |
| ... Furthermore gives the possibility to pause the execution. |
| Start Logging Setup or Teardown Teardown-${SUITE NAME} |
| Run Keyword If ${pausebeforecleanup} Import Library Dialogs |
| Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up! |
| Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes |
| Run Keyword If ${teardown_device} Delete All Devices and Verify |
| Run Keyword Unless ${etcdcheckintestteardown} Wait Until Keyword Succeeds ${timeout} 1s |
| ... Validate Onu Data In Etcd ${INFRA_NAMESPACE} 0 ${kvstoreprefix} without_pm_data=False |
| Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} 0 BBSM ${timeout} |
| Run Keyword If ${logging} Collect Logs |
| Stop Logging Setup or Teardown Teardown-${SUITE NAME} |
| Close All ONOS SSH Connections |
| Set Suite Variable ${TechProfile} ${EMPTY} |
| Run Keyword If ${preload_tech_profile} Remove Tech Profile ${INFRA_NAMESPACE} 64 |
| Run Keyword If ${preload_tech_profile} Remove Tech Profile ${INFRA_NAMESPACE} 65 |
| Run Keyword If ${preload_tech_profile} Remove Tech Profile ${INFRA_NAMESPACE} 66 |
| |
| Teardown Test |
| [Documentation] Post-test Teardown |
| # log ONOS flows after remove check |
| ${flow}= Run Keyword If "${TEST STATUS}"=="FAIL" Execute ONOS CLI Command use single connection |
| ... ${ONOS_SSH_IP} ${ONOS_SSH_PORT} flows -s any ${of_id} |
| Run Keyword If "${TEST STATUS}"=="FAIL" Log ${flow} |
| Run Keyword If ${pausebeforecleanup} Import Library Dialogs |
| Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up! |
| Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes |
| Run Keyword If ${teardown_device} Delete All Devices and Verify |
| # delete etcd MIB Template Data |
| Delete MIB Template Data ${INFRA_NAMESPACE} |
| # check etcd data are empty |
| Run Keyword If ${etcdcheckintestteardown} Wait Until Keyword Succeeds ${timeout} 1s |
| ... Validate Onu Data In Etcd ${INFRA_NAMESPACE} 0 ${kvstoreprefix} without_pm_data=False |
| Sleep 5s |
| |
| Check for new ONU Device IDs |
| [Documentation] Checks that no old onu device ids stay |
| [Arguments] ${old_device_ids} |
| ${new_device_ids}= Get ONUs Device IDs from Voltha |
| Should Not Be Empty ${new_device_ids} No new ONU device IDs |
| FOR ${item} IN @{old_device_ids} |
| List Should Not Contain Value ${new_device_ids} ${item} Old device id ${item} still present. |
| END |