*** Settings ***
Documentation Negative test states of ONU Go adapter with ATT workflows only (not for DT/TT workflow!)
Suite Setup Setup Suite
Suite Teardown Teardown Suite
Test Setup Setup
Test Teardown Teardown
Library Collections
Library String
Library OperatingSystem
Library XML
Library RequestsLibrary
Library ../../libraries/DependencyLibrary.py
Resource ../../libraries/onos.robot
Resource ../../libraries/voltctl.robot
Resource ../../libraries/voltha.robot
Resource ../../libraries/utils.robot
Resource ../../libraries/k8s.robot
Resource ../../libraries/onu_utilities.robot
Resource ../../libraries/bbsim.robot
Resource ../../variables/variables.robot
Library kafka_robot.KafkaClient log_level=DEBUG WITH NAME kafka
Library grpc_robot.VolthaTools WITH NAME volthatools
*** Variables ***
${NAMESPACE} voltha
${INFRA_NAMESPACE} default
${timeout} 300s
${of_id} 0
${logical_id} 0
${has_dataplane} True
${external_libs} True
${teardown_device} True
${scripts} ../../scripts
# Per-test logging on failure is turned off by default; set this variable to enable
${container_log_dir} ${None}
# KV Store Prefix
# example: -v kvstoreprefix:voltha/voltha_voltha
${kvstoreprefix} voltha/voltha_voltha
# used tech profile, can be passed via the command line too, valid values: default (=1T1GEM), 1T4GEM, 1T8GEM
# example: -v techprofile:1T4GEM
${techprofile} default
# when voltha is running in k8s port forwarding is needed
# example: -v PORT_FORWARDING:False
${PORT_FORWARDING} True
# kafka ip e.g. ip of master host where k8s is running
# example: -v KAFKA_IP:10.0.2.15
${KAFKA_IP} 127.0.0.1
# kafka port: port of kafka nodeport
# example: -v KAFKA_PORT:30201
${KAFKA_PORT} 30201
# kafka service port: service port of kafka nodeport
# example: -v KAFKA_SVC_PORT:9094
${KAFKA_SVC_PORT} 9094
# flag debugmode is used, if true timeout calculation various, can be passed via the command line too
# example: -v debugmode:True
${debugmode} False
# logging flag to enable Collect Logs, can be passed via the command line too
# example: -v logging:True
${logging} False
# if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline!
# example: -v pausebeforecleanup:True
${pausebeforecleanup} False
# if True some outputs to console are done during running tests e.g. long duration flow test
# example: -v print2console:True
${print2console} False
${data_dir} ../data
# flag to choose the subscriber provisioning command type in ONOS
# TT often provision a single services for a subscriber (eg: hsia, voip, ...) one after the other.
# if set to True, command used is "volt-add-subscriber-unitag"
# if set to False, comand used is "volt-add-subscriber-access"
${unitag_sub} False
*** Test Cases ***
ONU Negative State Test
[Documentation] Validates the ONU Go adapter states will never leave starting-openomci
... Due to a 'omci-response-rate' lower than 8 more OMCI messages will be through away by BBSIM than
... repeated by openonu-go-adapter. So ONU will never leave starting-openomci state.
... Timeout has to set at least to 300s (or more)
[Tags] NegativeStateTestOnuGo
[Setup] Run Keywords Start Logging ONUNegativeStateTest
... AND kafka.Records Clear
... AND Setup
# Suite Variable will be overwritten by Teardown of Current State Test All Onus
Set Suite Variable ${StateTestAllONUs} True
${seconds}= Convert Time ${timeout}
${seconds}= Convert To String ${seconds}
${seconds}= Get Substring ${seconds} 0 -2
FOR ${I} IN RANGE ${seconds}
Sleep 1s
Current State Test All Onus starting-openomci timeout=1x
Exit For Loop If not ${StateTestAllONUs}
END
${list_onu_device_id} Create List
Build ONU Device Id List ${list_onu_device_id}
Run Keyword If ${print2console} Log Check for device events that indicate a failed OMCI communication. console=yes
Wait Until Keyword Succeeds ${timeout} 5s Validate Failed OMCI Communication All ONUs ${list_onu_device_id}
# Validate OMCI counter statistics
Build ONU Device Id List ${list_onu_device_id}
FOR ${onu_device_id} IN @{list_onu_device_id}
# get ONU OMCI counter statistics per ONU
${rc} ${OMCI_counter_dict}= Get OMCI counter statistics dictionary ${onu_device_id}
${onu_sn}= Run Keyword If ${rc} != 0 Get SN From Device ID ${onu_device_id}
Run Keyword If ${rc} != 0 FAIL Could not get ONU OMCI counter statistic of ONU ${onu_sn}!
${TxOmciCounterRetries}= Get From Dictionary ${OMCI_counter_dict} TxOmciCounterRetries
${TxOmciCounterTimeouts}= Get From Dictionary ${OMCI_counter_dict} TxOmciCounterTimeouts
Should Be True 0 < ${TxOmciCounterRetries} No TxOmciCounterRetries found in baseline OMCI!
Should Be True 0 < ${TxOmciCounterTimeouts} No TxOmciCounterTimeouts found in baseline OMCI!
END
[Teardown] Run Keywords Printout ONU Serial Number and Device Id print2console=${print2console}
... AND Run Keyword If ${logging} Collect Logs
... AND Stop Logging ONUStateTest
*** Keywords ***
Setup Suite
[Documentation] Set up the test suite
Start Logging Setup or Teardown Setup-${SUITE NAME}
${LogInfo}= Catenate
... \r\nPassed arguments:
... techprofile:${techprofile},
... debugmode:${debugmode}, logging:${logging}, pausebeforecleanup:${pausebeforecleanup},
... print2console:${print2console}
Log ${LogInfo} console=yes
Common Test Suite Setup
${techprofile}= Set Variable If "${techprofile}"=="1T1GEM" default ${techprofile}
Set Suite Variable ${techprofile}
Run Keyword If "${techprofile}"=="default" Log To Console \nTechProfile:default (1T1GEM)
... ELSE IF "${techprofile}"=="1T4GEM" Set Tech Profile 1T4GEM ${INFRA_NAMESPACE}
... ELSE IF "${techprofile}"=="1T8GEM" Set Tech Profile 1T8GEM ${INFRA_NAMESPACE}
... ELSE Fail The TechProfile (${techprofile}) is not valid!
# delete etcd MIB Template Data
Delete MIB Template Data ${INFRA_NAMESPACE}
# delete etcd onu data
Delete ONU Go Adapter ETCD Data namespace=${INFRA_NAMESPACE} validate=True
# set ${kafka} depending on environment in case of port-forward is needed
${rc} ${kafka}= Run Keyword If ${PORT_FORWARDING} Run and Return Rc and Output
... kubectl get svc -n ${INFRA_NAMESPACE} | grep kafka-0-external | awk '{print $1}'
Run Keyword If ${PORT_FORWARDING} Should Not Be Empty ${kafka} Service kafka-0-external not found
# start port forwarding if needed (when voltha runs in k8s)
${portFwdHandle} = Run Keyword If ${PORT_FORWARDING} Start Process
... kubectl port-forward --address 0.0.0.0 --namespace default svc/${kafka} ${KAFKA_PORT}:${KAFKA_SVC_PORT} &
... shell=true
Set Suite Variable ${portFwdHandle}
Sleep 5s
# open connection to read kafka bus
Wait Until Keyword Succeeds 3x 5s
... kafka.Connection Open ${KAFKA_IP} ${KAFKA_PORT} voltha.events timestamp_from=0
Run Keyword If ${logging} Collect Logs
Stop Logging Setup or Teardown Setup-${SUITE NAME}
Teardown Suite
[Documentation] Replaces the Suite Teardown in utils.robot.
... Cleans up and checks all ONU ports disabled in ONOS.
... Furthermore gives the possibility to pause the execution.
Start Logging Setup or Teardown Teardown-${SUITE NAME}
Run Keyword If ${pausebeforecleanup} Import Library Dialogs
Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up!
Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes
Run Keyword If ${teardown_device} Delete All Devices and Verify
# close connection to kafka
kafka.Connection Close
# stop port forwarding if started
Run Keyword If ${PORT_FORWARDING} Terminate Process ${portFwdHandle} kill=true
Wait Until Keyword Succeeds ${timeout} 1s Validate Onu Data In Etcd ${INFRA_NAMESPACE} 0 ${kvstoreprefix}
... without_pm_data=False
Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} 0 BBSM ${timeout}
Run Keyword If ${logging} Collect Logs
Stop Logging Setup or Teardown Teardown-${SUITE NAME}
Close All ONOS SSH Connections
Remove Tech Profile ${INFRA_NAMESPACE}
Validate Failed OMCI Communication All ONUs
[Documentation] Validates Failed OMCI communication Events per ONU
[Arguments] ${list_onu_device_id}
${Kafka_Records}= kafka.Records Get voltha.events
${RecordsLength}= Get Length ${Kafka_Records}
FOR ${Index} IN RANGE 0 ${RecordsLength}
${metric}= Set Variable ${Kafka_Records[${Index}]}
${message}= Get From Dictionary ${metric} message
${event}= volthatools.Events Decode Event ${message} return_default=true
Continue For Loop If not 'device_event' in ${event}
${event_name}= Get From Dictionary ${event['device_event']} device_event_name
Continue For Loop If "${event_name}" != "ONU_OMCI_COMMUNICATION_FAILURE_CONFIG"
${resource_id}= Get From Dictionary ${event['device_event']} resource_id
Remove Values From List ${list_onu_device_id} ${resource_id}
END
Should Be Empty ${list_onu_device_id} Missing MIB Audits for ONUs ${list_onu_device_id}!