| # Copyright 2020-2024 Open Networking Foundation (ONF) and the ONF Contributors |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| |
| *** Settings *** |
| Documentation Test MIB Template handling of ONU Go adapter |
| ... with BBSIM controlledActivation: only-onu only! |
| ... Set up BBSIM with 'onu=2' (as well as 'pon=2') and 'controlledActivation=only-onu' e.g. with Extra Helm Flags! |
| ... Run robot with bbsim-kind-2x2.yaml (needed for test case ONU MIB Template Data Test) |
| ... For test cases Unknown ME/Attribute bbsim-kind.yaml would work too. |
| ... For Unknown ME set up BBSIM with injectOmciUnknownME=true e.g. with Extra Helm Flags! |
| ... For Unknown Attribute set up BBSIM with injectOmciUnknownAttributes=true e.g. with Extra Helm Flags! |
| Suite Setup Setup Suite |
| Suite Teardown Teardown Suite |
| Test Setup Setup |
| Test Teardown Teardown |
| Library Collections |
| Library String |
| Library OperatingSystem |
| Library XML |
| Library RequestsLibrary |
| Library ../../libraries/DependencyLibrary.py |
| Resource ../../libraries/onos.robot |
| Resource ../../libraries/voltctl.robot |
| Resource ../../libraries/voltha.robot |
| Resource ../../libraries/utils.robot |
| Resource ../../libraries/k8s.robot |
| Resource ../../libraries/onu_utilities.robot |
| Resource ../../libraries/bbsim.robot |
| Resource ../../variables/variables.robot |
| |
| *** Variables *** |
| ${NAMESPACE} voltha |
| ${INFRA_NAMESPACE} default |
| ${timeout} 60s |
| ${of_id} 0 |
| ${logical_id} 0 |
| ${has_dataplane} True |
| ${external_libs} True |
| ${teardown_device} True |
| ${scripts} ../../scripts |
| # Per-test logging on failure is turned off by default; set this variable to enable |
| ${container_log_dir} ${None} |
| |
| # flag debugmode is used, if true timeout calculation various, can be passed via the command line too |
| # example: -v debugmode:True |
| ${debugmode} False |
| # logging flag to enable Collect Logs, can be passed via the command line too |
| # example: -v logging:True |
| ${logging} False |
| # if True execution will be paused before clean up |
| # example: -v pausebeforecleanup:True |
| ${pausebeforecleanup} False |
| # Log Level of Helm chart |
| # example: -v helmloglevel:WARN |
| ${helmloglevel} DEBUG |
| ${data_dir} ../data |
| |
| # flag to choose the subscriber provisioning command type in ONOS |
| # TT often provision a single services for a subscriber (eg: hsia, voip, ...) one after the other. |
| # if set to True, command used is "volt-add-subscriber-unitag" |
| # if set to False, comand used is "volt-add-subscriber-access" |
| ${unitag_sub} False |
| |
| *** Test Cases *** |
| ONU MIB Template Data Test |
| [Documentation] Validates ONU Go adapter storage of MIB Template Data in etcd and checks the usage |
| ... - setup one ONU |
| ... - request MIB-Upload-Data by ONU via OMCI |
| ... - storage MIB-Upload-Data in etcd |
| ... - store setup duration of ONU |
| ... - check Template-Data in etcd stored (service/%{NAME}/omci_mibs/go_templates/) |
| ... - setup second ONU |
| ... - collect setup durationof second ONU |
| ... - compare both duration |
| ... - duration of second ONU should be at least 10 times faster than the first one |
| ... - MIB-Upload-Data should not requested via OMCI by second ONU |
| ... - MIB-Upload-Data should read from etcd |
| [Tags] functionalOnuGo MibTemplateOnuGo |
| [Setup] Run Keywords Start Logging ONUMibTemplateTest |
| ... AND Setup |
| Perform ONU MIB Template Data Test |
| [Teardown] Run Keywords Printout ONU Serial Number and Device Id |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Teardown Test |
| ... AND Stop Logging ONUMibTemplateTest |
| |
| ONU MIB Template Unknown ME Test |
| [Documentation] Validates ONU Go adapter storage of MIB Template Data in etcd in case of unknown ME |
| ... - setup one ONU |
| ... - request MIB-Upload-Data by ONU via OMCI |
| ... - storage MIB-Upload-Data in etcd |
| ... - check Template-Data in etcd stored (service/voltha/omci_mibs/go_templates/) |
| ... - Template-Data in etcd stored should contain "UnknownItuG988ManagedEntity" |
| [Tags] functionalOnuGo UnknownMeOnuGo |
| [Setup] Run Keywords Start Logging UnknownMeOnuGo |
| ... AND Setup |
| Bring Up ONU |
| ${MibTemplateData}= Get ONU MIB Template Data ${INFRA_NAMESPACE} |
| ${MibTemplatePrep}= Prepare ONU Go Adapter ETCD Data For Json ${MibTemplateData} |
| ${MibTemplateJson}= To Json ${MibTemplatePrep} |
| Dictionary Should Contain Key ${MibTemplateJson[0]} UnknownItuG988ManagedEntity |
| ${UnknownME}= Get From Dictionary ${MibTemplateJson[0]} UnknownItuG988ManagedEntity |
| Dictionary Should Contain Key ${UnknownME} 37 |
| ${Attributes}= Get From Dictionary ${UnknownME['37']} 1 |
| ${AttributeMask}= Get From Dictionary ${Attributes} AttributeMask |
| ${AttributeBytes}= Get From Dictionary ${Attributes} AttributeBytes |
| Should be Equal ${AttributeMask} 0x8000 |
| Should be Equal ${AttributeBytes} 0102030405060708090a0b0c0d0e0f101112131415161718191a |
| [Teardown] Run Keywords Printout ONU Serial Number and Device Id |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Teardown Test |
| ... AND Stop Logging UnknownMeOnuGo |
| |
| ONU MIB Template Unknown Attribute Test |
| [Documentation] Validates ONU Go adapter storage of MIB Template Data in etcd in case of unknown Attribute |
| ... - setup one ONU |
| ... - request MIB-Upload-Data by ONU via OMCI |
| ... - storage MIB-Upload-Data in etcd |
| ... - check Template-Data in etcd stored (service/voltha/omci_mibs/go_templates/) |
| ... - Template-Data in etcd stored should contain "UnknownAttributesManagedEntity" |
| [Tags] functionalOnuGo UnknownAttributeOnuGo |
| [Setup] Run Keywords Start Logging UnknownAttributeOnuGo |
| ... AND Setup |
| Bring Up ONU |
| ${MibTemplateData}= Get ONU MIB Template Data ${INFRA_NAMESPACE} |
| ${MibTemplatePrep}= Prepare ONU Go Adapter ETCD Data For Json ${MibTemplateData} |
| ${MibTemplateJson}= To Json ${MibTemplatePrep} |
| Dictionary Should Contain Key ${MibTemplateJson[0]} UnknownAttributesManagedEntity |
| ${UnknownME}= Get From Dictionary ${MibTemplateJson[0]} UnknownAttributesManagedEntity |
| Dictionary Should Contain Key ${UnknownME} 257 |
| ${Attributes}= Get From Dictionary ${UnknownME['257']} 0 |
| ${AttributeMask}= Get From Dictionary ${Attributes} AttributeMask |
| ${AttributeBytes}= Get From Dictionary ${Attributes} AttributeBytes |
| Should be Equal ${AttributeMask} 0x0001 |
| Should be Equal ${AttributeBytes} 000100010001000000 |
| [Teardown] Run Keywords Printout ONU Serial Number and Device Id |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Teardown Test |
| ... AND Stop Logging UnknownAttributeOnuGo |
| |
| |
| ONU MIB Template Data Compare OMCI Baseline and Extended Message |
| [Documentation] Compares ONU Go adapter storage of MIB Template Data in etcd according OMCI message format |
| ... - setup one ONU with baseline OMCI message (EXTRA_HELM_FLAGS=" --set omccVersion=163) |
| ... - request MIB-Upload-Data by ONU via OMCI |
| ... - storage MIB-Upload-Data in etcd |
| ... - store setup duration of ONU |
| ... - check Template-Data in etcd stored (service/%{NAME}/omci_mibs/go_templates/) |
| ... - store Template-Data |
| ... - delete all devices and etcd/mib data |
| ... - setup one ONU with extended OMCI message (EXTRA_HELM_FLAGS=" --set omccVersion=180) |
| ... - request MIB-Upload-Data by ONU via OMCI |
| ... - storage MIB-Upload-Data in etcd |
| ... - store setup duration of ONU |
| ... - check Template-Data in etcd stored (service/%{NAME}/omci_mibs/go_templates/) |
| ... - compare both duration |
| ... - duration of extended msg ONU should be at least less than 80% of the baseline one |
| ... - compare MIB-Data, should be the same |
| ... ================= !!! Attention!!! ====================== |
| ... Should be always the last test case in test suite! |
| ... It changes BBSIM configuration to OMCI extended messages. |
| ... ================= !!! Attention!!! ====================== |
| [Tags] functionalOnuGo MibTemplateOmciBaselineVersusExtendedOnuGo |
| [Setup] Start Logging MibTemplateOmciBaselineVersusExtendedOnuGo |
| Perform ONU MIB Template Compare OMCI Baseline and Extended Message |
| [Teardown] Run Keywords Printout ONU Serial Number and Device Id |
| ... AND Run Keyword If ${logging} Collect Logs |
| ... AND Teardown Test |
| ... AND Stop Logging MibTemplateOmciBaselineVersusExtendedOnuGo |
| |
| *** Keywords *** |
| Setup Suite |
| [Documentation] Set up the test suite |
| Start Logging Setup or Teardown Setup-${SUITE NAME} |
| ${LogInfo}= Catenate |
| ... \r\nPassed arguments: |
| ... debugmode:${debugmode}, logging:${logging}, pausebeforecleanup:${pausebeforecleanup}, |
| Log ${LogInfo} console=yes |
| Common Test Suite Setup |
| # delete etcd MIB Template Data |
| Delete MIB Template Data ${INFRA_NAMESPACE} |
| Run Keyword If ${logging} Collect Logs |
| Stop Logging Setup or Teardown Setup-${SUITE NAME} |
| |
| Teardown Suite |
| [Documentation] Replaces the Suite Teardown in utils.robot. |
| ... Cleans up and checks all ONU ports disabled in ONOS. |
| ... Furthermore gives the possibility to pause the execution. |
| Start Logging Setup or Teardown Teardown-${SUITE NAME} |
| Run Keyword If ${pausebeforecleanup} Import Library Dialogs |
| Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up! |
| Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes |
| Run Keyword If ${teardown_device} Delete All Devices and Verify |
| Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} 0 BBSM |
| # delete etcd MIB Template Data (for repeating test) |
| Delete MIB Template Data ${INFRA_NAMESPACE} |
| Run Keyword If ${logging} Collect Logs |
| Stop Logging Setup or Teardown Teardown-${SUITE NAME} |
| Close All ONOS SSH Connections |
| |
| Teardown Test |
| [Documentation] Post-test Teardown |
| Run Keyword If ${pausebeforecleanup} Import Library Dialogs |
| Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up! |
| Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes |
| Run Keyword If ${teardown_device} Delete All Devices and Verify |
| # delete etcd MIB Template Data |
| Delete MIB Template Data ${INFRA_NAMESPACE} |
| Sleep 5s |
| |
| Perform ONU MIB Template Data Test |
| [Documentation] This keyword performs ONU MIB Template Data Test |
| ${firstonu}= Set Variable 0 |
| ${secondonu}= Set Variable 1 |
| ${state2test}= Set Variable omci-flows-pushed |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| # Start first Onu |
| ${src}= Set Variable ${hosts.src[${0}]} |
| Log \r\nONU ${src['onu']}: startup with MIB upload cycle and storage of template data to etcd. console=yes |
| ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release bbsim0 |
| Power On ONU ${NAMESPACE} ${bbsim_pod} ${src['onu']} |
| ${timeStart}= Get Current Date |
| ${firstonustartup}= Get ONU Startup Duration ${state2test} ${firstonu} ${timeStart} |
| # check MIB Template data stored in etcd |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 3s |
| ... Verify MIB Template Data Available ${INFRA_NAMESPACE} |
| # Start second Onu |
| ${src}= Set Variable ${hosts.src[${1}]} |
| Log ONU ${src['onu']}: startup without MIB upload cycle by using of template data of etcd. console=yes |
| ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release bbsim0 |
| Power On ONU ${NAMESPACE} ${bbsim_pod} ${src['onu']} |
| ${timeStart}= Get Current Date |
| ${secondonustartup}= Get ONU Startup Duration ${state2test} ${secondonu} ${timeStart} |
| # compare both durations, second onu should be at least 3 times faster |
| ${status} Evaluate ${firstonustartup}>=${secondonustartup}*3 |
| Should Be True ${status} |
| ... Startup durations (${firstonustartup} and ${secondonustartup}) do not full fill the requirements of 1/10. |
| |
| Perform ONU MIB Template Compare OMCI Baseline and Extended Message |
| [Documentation] This keyword performs ONU MIB Template Data Compare OMCI Baseline and Extended Message |
| ${firstonu}= Set Variable 0 |
| ${waittime}= Set Variable 0ms |
| ${state2test}= Set Variable initial-mib-downloaded |
| Run Keyword If ${has_dataplane} Clean Up Linux |
| ${omcc_version} ${is_omcc_extended}= Get BBSIM OMCC Version ${NAMESPACE} |
| # Restart BBSIM with OMCI Baseline Message if needed |
| ${extra_helm_flags} Catenate |
| ... --set onu=2,pon=2,controlledActivation=only-onu,injectOmciUnknownAttributes=true,injectOmciUnknownMe=true |
| ... --set omccVersion=163 |
| Run Keyword If ${is_omcc_extended} Restart BBSIM by Helm Charts ${NAMESPACE} extra_helm_flags=${extra_helm_flags} |
| Setup |
| ${src}= Set Variable ${hosts.src[${firstonu}]} |
| Log \r\nONU ${src['onu']}: startup with MIB upload cycle and storage of template data to etcd. console=yes |
| ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release bbsim0 |
| Power On ONU ${NAMESPACE} ${bbsim_pod} ${src['onu']} |
| ${timeStart}= Get Current Date |
| ${baselineonustartup}= Get ONU Startup Duration ${state2test} ${firstonu} ${timeStart} ${waittime} |
| # check MIB Template data stored in etcd |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 3s |
| ... Verify MIB Template Data Available ${INFRA_NAMESPACE} |
| ${MibTemplateDataBaseline}= Get ONU MIB Template Data ${INFRA_NAMESPACE} |
| # get ONU OMCI counter statistics |
| # Validation is commented due to onu_omci_stats is not supported by getextval |
| #${onu_device_id}= Get Device ID From SN ${src['onu']} |
| #${rc} ${OMCI_counter_dict}= Get OMCI counter statistics dictionary ${onu_device_id} |
| #Run Keyword If ${rc} != 0 FAIL Could not get baseline ONU OMCI counter statistic of ONU ${src['onu']}! |
| #${BaseTxArFrames}= Get From Dictionary ${OMCI_counter_dict} BaseTxArFrames |
| #${BaseRxAkFrames}= Get From Dictionary ${OMCI_counter_dict} BaseRxAkFrames |
| #Should Be Equal As Integers ${BaseTxArFrames} ${BaseRxAkFrames} Number of baseline Rx and Tx frames do not match! |
| # some additional checks |
| #${ExtRxAkFrames}= Get From Dictionary ${OMCI_counter_dict} ExtRxAkFrames |
| #${ExtRxNoAkFrames}= Get From Dictionary ${OMCI_counter_dict} ExtRxNoAkFrames |
| #${ExtTxArFrames}= Get From Dictionary ${OMCI_counter_dict} ExtTxArFrames |
| #${ExtTxNoArFrames}= Get From Dictionary ${OMCI_counter_dict} ExtTxNoArFrames |
| #${TxOmciCounterRetries}= Get From Dictionary ${OMCI_counter_dict} TxOmciCounterRetries |
| #${TxOmciCounterTimeouts}= Get From Dictionary ${OMCI_counter_dict} TxOmciCounterTimeouts |
| #Should Be Equal 0 ${ExtRxAkFrames} ExtRxAkFrames found in baseline OMCI! |
| #Should Be Equal 0 ${ExtRxNoAkFrames} ExtRxNoAkFrames found in baseline OMCI! |
| #Should Be Equal 0 ${ExtTxArFrames} ExtTxArFrames found in baseline OMCI! |
| #Should Be Equal 0 ${ExtTxNoArFrames} ExtTxNoArFrames found in baseline OMCI! |
| #Should Be Equal 0 ${TxOmciCounterRetries} TxOmciCounterRetries found in baseline OMCI! |
| #Should Be Equal 0 ${TxOmciCounterTimeouts} TxOmciCounterTimeouts found in baseline OMCI! |
| Delete All Devices and Verify |
| Delete MIB Template Data ${INFRA_NAMESPACE} |
| # Restart BBSIM with OMCI Extended Message |
| ${extra_helm_flags} Catenate |
| ... --set onu=2,pon=2,controlledActivation=only-onu,injectOmciUnknownAttributes=true,injectOmciUnknownMe=true |
| ${extra_helm_flags}= Run Keyword If ${is_omcc_extended} |
| ... Catenate ${extra_helm_flags} --set omccVersion=${omcc_version} |
| ... ELSE Catenate ${extra_helm_flags} --set omccVersion=180 |
| Restart BBSIM by Helm Charts ${NAMESPACE} extra_helm_flags=${extra_helm_flags} |
| # Start Onu again with OMCI Extended Message |
| Setup |
| ${src}= Set Variable ${hosts.src[${firstonu}]} |
| Log \r\nONU ${src['onu']}: startup with MIB upload cycle and storage of template data to etcd. console=yes |
| ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release bbsim0 |
| Power On ONU ${NAMESPACE} ${bbsim_pod} ${src['onu']} |
| ${timeStart}= Get Current Date |
| ${extendedonustartup}= Get ONU Startup Duration ${state2test} ${firstonu} ${timeStart} ${waittime} |
| # check MIB Template data stored in etcd |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 3s |
| ... Verify MIB Template Data Available ${INFRA_NAMESPACE} |
| ${MibTemplateDataExtended}= Get ONU MIB Template Data ${INFRA_NAMESPACE} |
| # Checks: |
| # - compare durations of MIB download, OMCI extended message duration should be less than %60 of baseline |
| # - both stored MIB tenmplates in ETCD should be equal |
| ${duration_compare}= Evaluate ${baselineonustartup}*0.8 > ${extendedonustartup} |
| Should Be True ${duration_compare} MIB Template download too slow for OMCI extended message! |
| # remove "TemplateCreated" e.g. "TemplateCreated":"2022-06-15 11:23:47.306519", |
| ${remove_regexp} Set Variable (?ms)"TemplateCreated":"[^"]*", |
| ${MibTemplateDataBaseline}= Remove String Using Regexp ${MibTemplateDataBaseline} ${remove_regexp} |
| ${MibTemplateDataExtended}= Remove String Using Regexp ${MibTemplateDataExtended} ${remove_regexp} |
| # Due to VOL-4721 comparison of MIB templates has to be executed without unknown ME! |
| # After correction of Jira remove the following lines and this comment |
| ${remove_regexp} Set Variable (?ms)"UnknownItuG988ManagedEntity":[^}]*}}} |
| ${MibTemplateDataBaseline}= Remove String Using Regexp ${MibTemplateDataBaseline} ${remove_regexp} |
| ${MibTemplateDataExtended}= Remove String Using Regexp ${MibTemplateDataExtended} ${remove_regexp} |
| # end of handling for VOL-4721 |
| Should Be Equal As Strings ${MibTemplateDataBaseline} ${MibTemplateDataExtended} MIB Templates not equal! |
| # get ONU OMCI counter statistics |
| ${onu_device_id}= Get Device ID From SN ${src['onu']} |
| #${rc} ${OMCI_counter_dict}= Get OMCI counter statistics dictionary ${onu_device_id} |
| #Run Keyword If ${rc} != 0 FAIL Could not get extended ONU OMCI counter statistic of ONU ${src['onu']}! |
| #${ExtTxArFrames}= Get From Dictionary ${OMCI_counter_dict} ExtTxArFrames |
| #${ExtRxAkFrames}= Get From Dictionary ${OMCI_counter_dict} ExtRxAkFrames |
| #Should Be Equal As Integers ${ExtTxArFrames} ${ExtRxAkFrames} Number of extended Rx and Tx frames do not match! |
| # check baseline and extended OMCI frames counter |
| #${TxArFrames_compare}= Evaluate ${BaseTxArFrames}*0.05 > ${ExtTxArFrames} |
| #Should Be True ${TxArFrames_compare} Comparison of TxArFrames failed (${BaseTxArFrames}:${ExtTxArFrames})! |
| #${RxAkFrames_compare}= Evaluate ${BaseRxAkFrames}*0.05 > ${ExtRxAkFrames} |
| #Should Be True ${RxAkFrames_compare} Comparison of RxAkFrames failed (${BaseRxAkFrames}:${ExtRxAkFrames})! |
| # some additional checks |
| #${TxOmciCounterRetries}= Get From Dictionary ${OMCI_counter_dict} TxOmciCounterRetries |
| #${TxOmciCounterTimeouts}= Get From Dictionary ${OMCI_counter_dict} TxOmciCounterTimeouts |
| #Should Be Equal 0 ${TxOmciCounterRetries} TxOmciCounterRetries found in extended OMCI! |
| #Should Be Equal 0 ${TxOmciCounterTimeouts} TxOmciCounterTimeouts found in extended OMCI! |
| # Restart BBSIM with OMCI Message Version read at begin of test |
| ${extra_helm_flags}= Catenate |
| ... --set onu=2,pon=2,controlledActivation=only-onu,injectOmciUnknownAttributes=true,injectOmciUnknownMe=true |
| ... --set omccVersion=${omcc_version} |
| Run Keyword Unless ${is_omcc_extended} Restart BBSIM by Helm Charts ${NAMESPACE} extra_helm_flags=${extra_helm_flags} |
| |
| Get ONU Startup Duration |
| [Documentation] This keyword delivers startup duration of onu |
| [Arguments] ${state2test} ${onu} ${starttime} ${waittime}=50ms |
| ${src}= Set Variable ${hosts.src[${onu}]} |
| ${admin_state} ${oper_status} ${connect_status} ${onu_state_nb} ${onu_state}= |
| ... Map State ${state2test} |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} ${waittime} |
| ... Validate Device ${admin_state} ${oper_status} ${connect_status} |
| ... ${src['onu']} onu=True onu_reason=${onu_state} |
| ${timeCurrent} = Get Current Date |
| ${timeTotalMs} = Subtract Date From Date ${timeCurrent} ${startTime} result_format=number |
| Log ONU ${src['onu']}: reached the state ${onu_state} after ${timeTotalMs} sec. console=yes |
| [Return] ${timeTotalMs} |
| |
| Bring Up ONU |
| [Documentation] This keyword brings up onu |
| [Arguments] ${onu}=0 ${state2reach}=omci-flows-pushed |
| ${src}= Set Variable ${hosts.src[${onu}]} |
| ${admin_state} ${oper_status} ${connect_status} ${onu_state_nb} ${onu_state}= |
| ... Map State ${state2reach} |
| ${bbsim_pod}= Get Pod Name By Label ${NAMESPACE} release bbsim0 |
| Power On ONU ${NAMESPACE} ${bbsim_pod} ${src['onu']} |
| Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 1s |
| ... Validate Device ${admin_state} ${oper_status} ${connect_status} |
| ... ${src['onu']} onu=True onu_reason=${onu_state} |