blob: 593a9641555c367443aec0535f7af78826eccd42 [file] [log] [blame]
TorstenThiemed4f48962020-12-08 12:17:19 +00001# Copyright 2020 - present Open Networking Foundation
TorstenThiemefd7e7ba2020-11-06 13:57:57 +00002#
3# Licensed under the Apache License, Version 2.0 (the "License");
4# you may not use this file except in compliance with the License.
5# You may obtain a copy of the License at
6#
7# http://www.apache.org/licenses/LICENSE-2.0
8#
9# Unless required by applicable law or agreed to in writing, software
10# distributed under the License is distributed on an "AS IS" BASIS,
11# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
12# See the License for the specific language governing permissions and
13# limitations under the License.
TorstenThiemefd7e7ba2020-11-06 13:57:57 +000014
15*** Settings ***
16Documentation Library for various openonu-go-adpter utilities
TorstenThieme7c397d72021-07-14 11:51:09 +000017Library grpc_robot.VolthaTools WITH NAME volthatools
TorstenThiemefd7e7ba2020-11-06 13:57:57 +000018
TorstenThiemed4f48962020-12-08 12:17:19 +000019
TorstenThiemefd7e7ba2020-11-06 13:57:57 +000020*** Keywords ***
TorstenThieme440b7c02020-12-18 15:42:57 +000021Calculate Timeout
22 [Documentation] Calculates the timeout regarding num-onus in case of more than 4 onus
23 [Arguments] ${basetimeout}=60s
24 ${new_timeout} Fetch From Left ${basetimeout} s
25 ${new_timeout}= evaluate ${new_timeout}+((${num_all_onus}-4)*10)
26 ${new_timeout}= Set Variable If (not ${debugmode}) and (${new_timeout}>300)
27 ... 300 ${new_timeout}
28 ${new_timeout}= Catenate SEPARATOR= ${new_timeout} s
29 [Return] ${new_timeout}
30
TorstenThieme3494ceb2021-07-19 09:47:24 +000031Get Logical Id of OLT
32 [Documentation] Fills the logical id of OLT(s) if missing
33 FOR ${I} IN RANGE 0 ${num_olts}
34 # exit loop if logical id already known
35 Exit For Loop IF "${olt_ids}[${I}][logical_id]" != "${EMPTY}"
36 #read current device values
37 ${olt}= Get From List ${olt_ids} ${I}
38 ${olt_serial_number}= Get From Dictionary ${olt} sn
39 # read logical id and store it
40 ${logical_id}= Get Logical Device ID From SN ${olt_serial_number}
41 Set To Dictionary ${olt} logical_id ${logical_id}
42 Set List Value ${olt_ids} ${I} ${olt}
43 END
44 Set Global Variable ${olt_ids}
45
TorstenThieme440b7c02020-12-18 15:42:57 +000046Power On ONU Device
47 [Documentation] This keyword turns on the power for all onus.
48 [Arguments] ${namespace}
TorstenThiemefe7099e2021-01-29 08:41:04 +000049 FOR ${J} IN RANGE 0 ${num_olts}
50 ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
51 ${bbsim}= Catenate SEPARATOR= bbsim ${J}
52 ${bbsim_pod}= Get Pod Name By Label ${namespace} release ${bbsim}
53 Power On ONU Device per OLT ${namespace} ${olt_serial_number} ${bbsim_pod}
54 END
55
56Power On ONU Device per OLT
57 [Documentation] This keyword turns on the power for all onus.
58 [Arguments] ${namespace} ${olt_serial_number} ${bbsim_pod}
TorstenThiemefd7e7ba2020-11-06 13:57:57 +000059 FOR ${I} IN RANGE 0 ${num_all_onus}
60 ${src}= Set Variable ${hosts.src[${I}]}
TorstenThiemefe7099e2021-01-29 08:41:04 +000061 Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
62 Power On ONU ${namespace} ${bbsim_pod} ${src['onu']}
TorstenThiemefd7e7ba2020-11-06 13:57:57 +000063 END
64
TorstenThieme440b7c02020-12-18 15:42:57 +000065Power Off ONU Device
TorstenThiemefe7099e2021-01-29 08:41:04 +000066 [Documentation] This keyword turns off the power for all onus per olt.
TorstenThieme440b7c02020-12-18 15:42:57 +000067 [Arguments] ${namespace}
TorstenThiemefe7099e2021-01-29 08:41:04 +000068 FOR ${J} IN RANGE 0 ${num_olts}
69 ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
70 ${bbsim}= Catenate SEPARATOR= bbsim ${J}
71 ${bbsim_pod}= Get Pod Name By Label ${namespace} release ${bbsim}
72 Power Off ONU Device per OLT ${namespace} ${olt_serial_number} ${bbsim_pod}
73 END
74
75Power Off ONU Device per OLT
76 [Documentation] This keyword turns off the power for all onus per olt.
77 [Arguments] ${namespace} ${olt_serial_number} ${bbsim_pod}
TorstenThieme440b7c02020-12-18 15:42:57 +000078 FOR ${I} IN RANGE 0 ${num_all_onus}
79 ${src}= Set Variable ${hosts.src[${I}]}
TorstenThiemefe7099e2021-01-29 08:41:04 +000080 Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
81 Power Off ONU ${namespace} ${bbsim_pod} ${src['onu']}
TorstenThieme440b7c02020-12-18 15:42:57 +000082 END
83
84Current State Test
TorstenThiemefd7e7ba2020-11-06 13:57:57 +000085 [Documentation] This keyword checks the passed state of the given onu.
86 [Arguments] ${state} ${onu} ${reqadminstate}=${EMPTY} ${reqoperstatus}=${EMPTY}
87 ... ${reqconnectstatus}=${EMPTY}
88 ${admin_state} ${oper_status} ${connect_status} ${onu_state_nb} ${onu_state}= Map State ${state}
89 ${admin_state}= Set Variable If '${reqadminstate}'!='${EMPTY}' ${reqadminstate} ${admin_state}
90 ${oper_status}= Set Variable If '${reqoperstatus}'!='${EMPTY}' ${reqoperstatus} ${oper_status}
91 ${connect_status}= Set Variable If '${reqconnectstatus}'!='${EMPTY}' ${reqconnectstatus}
92 ... ${connect_status}
93 Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 50ms
94 ... Validate Device ${admin_state} ${oper_status} ${connect_status}
95 ... ${onu} onu=True onu_reason=${onu_state}
96
TorstenThieme440b7c02020-12-18 15:42:57 +000097Current State Test All Onus
TorstenThiemefd7e7ba2020-11-06 13:57:57 +000098 [Documentation] This keyword checks the passed state of all onus.
99 ... Hint: ${timeStart} will be not evaluated here!
100 [Arguments] ${state} ${reqadminstate}=${EMPTY} ${reqoperstatus}=${EMPTY} ${reqconnectstatus}=${EMPTY}
TorstenThieme53450ff2021-05-11 09:44:33 +0000101 ... ${alternativeonustate}=${EMPTY} ${timeout}=${timeout}
TorstenThieme440b7c02020-12-18 15:42:57 +0000102 ${timeStart}= Get Current Date
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000103 ${list_onus} Create List
104 Build ONU SN List ${list_onus}
105 ${admin_state} ${oper_status} ${connect_status} ${onu_state_nb} ${onu_state}= Map State ${state}
106 ${admin_state}= Set Variable If '${reqadminstate}'!='${EMPTY}' ${reqadminstate} ${admin_state}
107 ${oper_status}= Set Variable If '${reqoperstatus}'!='${EMPTY}' ${reqoperstatus} ${oper_status}
108 ${connect_status}= Set Variable If '${reqconnectstatus}'!='${EMPTY}' ${reqconnectstatus}
109 ... ${connect_status}
110 Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 50ms
111 ... Validate ONU Devices With Duration
112 ... ${admin_state} ${oper_status} ${connect_status}
TorstenThieme52ef8392020-11-10 13:42:26 +0000113 ... ${onu_state} ${list_onus} ${timeStart} alternate_reason=${alternativeonustate}
TorstenThieme53450ff2021-05-11 09:44:33 +0000114 # teardown is used as 'return' for result of Validate ONU Devices With Duration (used for ONUNegativeStateTests)
115 [Teardown] Run Keyword If "${KEYWORD STATUS}"=="FAIL" Set Suite Variable ${StateTestAllONUs} False
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000116
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000117Log Ports
118 [Documentation] This keyword logs all port data available in ONOS of first port per ONU
119 [Arguments] ${onlyenabled}=False
120 ${cmd} Set Variable If ${onlyenabled} ports -e ports
TorstenThieme731a7592021-07-01 14:26:54 +0000121 ${onu_ports}= Execute ONOS CLI Command use single connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${cmd}
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000122 ${lines} = Get Lines Matching Regexp ${onu_ports} .*portName=BBSM[0-9]{8}-1
123 Log ${lines}
124
125Kill Adaptor
126 [Documentation] This keyword kills the passed adaptor.
127 [Arguments] ${namespace} ${name}
128 ${cmd} Catenate
129 ... kubectl exec -it -n voltha $(kubectl get pods -n ${namespace} | grep ${name} | awk 'NR==1{print $1}')
130 ... -- /bin/sh -c "kill 1"
131 ${rc} ${output}= Run and Return Rc and Output ${cmd}
132 Log ${output}
133
TorstenThieme440b7c02020-12-18 15:42:57 +0000134Kill And Check Onu Adaptor
135 [Documentation] This keyword kills ONU Adaptor and waits for it to come up again
136 ... Following steps will be executed:
137 ... - kill openonu adaptor
138 ... - check openonu adaptor is ready again
139 [Arguments] ${namespace}
140 ${list_openonu_apps} Create List adapter-open-onu
141 ${adaptorname}= Set Variable open-onu
142 Kill Adaptor ${namespace} ${adaptorname}
143 Sleep 5s
144 Wait For Pods Ready ${namespace} ${list_openonu_apps}
145
146Restart And Check Onu Adaptor
147 [Documentation] This keyword restarts ONU Adaptor and waits for it to come up again
148 ... Following steps will be executed:
149 ... - restart openonu adaptor
150 ... - check openonu adaptor is ready again
151 [Arguments] ${namespace}
152 ${list_openonu_apps} Create List adapter-open-onu
Matteo Scandolo6f24ea92021-04-29 11:55:50 -0700153 ${openonu_label_key} Set Variable app
154 ${openonu_label_value} Set Variable adapter-open-onu
155 Restart Pod By Label ${namespace} ${openonu_label_key} ${openonu_label_value}
TorstenThieme440b7c02020-12-18 15:42:57 +0000156 Sleep 5s
157 Wait For Pods Ready ${namespace} ${list_openonu_apps}
158
159Disable Onu Device
160 [Documentation] This keyword disables all onus.
TorstenThieme70bc5262021-01-19 12:12:55 +0000161 ${onu_list} Create List
TorstenThieme440b7c02020-12-18 15:42:57 +0000162 FOR ${I} IN RANGE 0 ${num_all_onus}
163 ${src}= Set Variable ${hosts.src[${I}]}
164 ${onu_device_id}= Get Device ID From SN ${src['onu']}
TorstenThieme70bc5262021-01-19 12:12:55 +0000165 ${onu_id}= Get Index From List ${onu_list} ${onu_device_id}
166 Continue For Loop If -1 != ${onu_id}
167 Append To List ${onu_list} ${onu_device_id}
TorstenThieme440b7c02020-12-18 15:42:57 +0000168 Disable Device ${onu_device_id}
169 Wait Until Keyword Succeeds 20s 2s Test Devices Disabled in VOLTHA Id=${onu_device_id}
170 END
171
172Enable Onu Device
173 [Documentation] This keyword enables all onus.
TorstenThieme70bc5262021-01-19 12:12:55 +0000174 ${onu_list} Create List
TorstenThieme440b7c02020-12-18 15:42:57 +0000175 FOR ${I} IN RANGE 0 ${num_all_onus}
176 ${src}= Set Variable ${hosts.src[${I}]}
177 ${onu_device_id}= Get Device ID From SN ${src['onu']}
TorstenThieme70bc5262021-01-19 12:12:55 +0000178 ${onu_id}= Get Index From List ${onu_list} ${onu_device_id}
179 Continue For Loop If -1 != ${onu_id}
180 Append To List ${onu_list} ${onu_device_id}
TorstenThieme440b7c02020-12-18 15:42:57 +0000181 Enable Device ${onu_device_id}
182 END
183
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000184Verify MIB Template Data Available
185 [Documentation] This keyword verifies MIB Template Data stored in etcd
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000186 [Arguments] ${namespace}=default
TorstenThiemed4f48962020-12-08 12:17:19 +0000187 ${podname}= Set Variable etcd
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000188 ${commandget} Catenate
Matteo Scandolo341b9372020-12-09 14:15:06 -0800189 ... /bin/sh -c 'ETCDCTL_API=3 etcdctl get --prefix service/voltha/omci_mibs/go_templates/'
Holger Hildebrandt23147742020-11-16 10:13:21 +0000190 ${result}= Exec Pod In Kube ${namespace} ${podname} ${commandget}
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000191 Should Not Be Empty ${result} No MIB Template Data stored in etcd!
192
193Delete MIB Template Data
194 [Documentation] This keyword deletes MIB Template Data stored in etcd
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000195 [Arguments] ${namespace}=default
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000196 ${podname}= Set Variable etcd
197 ${commanddel} Catenate
Matteo Scandolo341b9372020-12-09 14:15:06 -0800198 ... /bin/sh -c 'ETCDCTL_API=3 etcdctl del --prefix service/voltha/omci_mibs/go_templates/'
Holger Hildebrandt23147742020-11-16 10:13:21 +0000199 ${result}= Exec Pod In Kube ${namespace} ${podname} ${commanddel}
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000200 Sleep 3s
201 ${commandget} Catenate
Matteo Scandolo341b9372020-12-09 14:15:06 -0800202 ... /bin/sh -c 'ETCDCTL_API=3 etcdctl get --prefix service/voltha/omci_mibs/go_templates/'
Holger Hildebrandt23147742020-11-16 10:13:21 +0000203 ${result}= Exec Pod In Kube ${namespace} ${podname} ${commandget}
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000204 Should Be Empty ${result} Could not delete MIB Template Data stored in etcd!
205
TorstenThieme440b7c02020-12-18 15:42:57 +0000206Set Tech Profile
207 [Documentation] This keyword sets the passed TechProfile for the test
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000208 [Arguments] ${TechProfile} ${namespace}=default
TorstenThieme440b7c02020-12-18 15:42:57 +0000209 Log To Console \nTechProfile:${TechProfile}
TorstenThieme440b7c02020-12-18 15:42:57 +0000210 ${podname}= Set Variable etcd
Andrea Campanella0aa21d62021-07-22 10:44:32 +0200211 ${label}= Set Variable app.kubernetes.io/name=${podname}
TorstenThieme440b7c02020-12-18 15:42:57 +0000212 ${src}= Set Variable ${data_dir}/TechProfile-${TechProfile}.json
213 ${dest}= Set Variable /tmp/flexpod.json
214 ${command} Catenate
215 ... /bin/sh -c 'cat ${dest} | ETCDCTL_API=3 etcdctl put service/voltha/technology_profiles/XGS-PON/64'
Andrea Campanella0aa21d62021-07-22 10:44:32 +0200216 Copy File To Pod ${namespace} ${label} ${src} ${dest}
TorstenThieme440b7c02020-12-18 15:42:57 +0000217 Exec Pod In Kube ${namespace} ${podname} ${command}
218 ${commandget} Catenate
219 ... /bin/sh -c 'ETCDCTL_API=3 etcdctl get --prefix service/voltha/technology_profiles/XGS-PON/64'
Andrea Campanella0aa21d62021-07-22 10:44:32 +0200220 ${result}= Exec Pod In Kube ${namespace} ${podname} ${commandget}
221 Should Not Be Empty ${result} No Tech Profile stored in etcd!
TorstenThieme440b7c02020-12-18 15:42:57 +0000222
223Remove Tech Profile
224 [Documentation] This keyword removes TechProfile
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000225 [Arguments] ${namespace}=default
TorstenThieme440b7c02020-12-18 15:42:57 +0000226 Log To Console \nTechProfile:${TechProfile}
TorstenThieme440b7c02020-12-18 15:42:57 +0000227 ${podname}= Set Variable etcd
228 ${command} Catenate
229 ... /bin/sh -c 'ETCDCTL_API=3 etcdctl del --prefix service/voltha/technology_profiles/XGS-PON/64'
230 Exec Pod In Kube ${namespace} ${podname} ${command}
231 ${commandget} Catenate
232 ... /bin/sh -c 'ETCDCTL_API=3 etcdctl get --prefix service/voltha/technology_profiles/XGS-PON/64'
233 Exec Pod In Kube ${namespace} ${podname} ${commandget}
234
TorstenThiemea7315f12021-07-23 11:56:34 +0000235Do Onu Subscriber Add Per OLT
236 [Documentation] Add Subscriber per OLT
237 [Arguments] ${of_id} ${olt_serial_number} ${print2console}=False
238 FOR ${I} IN RANGE 0 ${num_all_onus}
239 ${src}= Set Variable ${hosts.src[${I}]}
240 Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
241 ${onu_device_id}= Get Device ID From SN ${src['onu']}
242 ${onu_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
243 ... Get ONU Port in ONOS ${src['onu']} ${of_id}
244 Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2
245 ... Execute ONOS CLI Command use single connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
246 ... volt-add-subscriber-access ${of_id} ${onu_port}
247 Run Keyword If ${print2console} Log \r\n[${I}] volt-add-subscriber-access ${of_id} ${onu_port}.
248 ... console=yes
249 END
250
251Do Onu Flow Check Per OLT
252 [Documentation] Checks all ONU flows show up in ONOS and Voltha
253 [Arguments] ${of_id} ${nni_port} ${olt_serial_number} ${print2console}=False
254 FOR ${I} IN RANGE 0 ${num_all_onus}
255 ${src}= Set Variable ${hosts.src[${I}]}
256 Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
257 ${onu_device_id}= Get Device ID From SN ${src['onu']}
258 ${onu_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
259 ... Get ONU Port in ONOS ${src['onu']} ${of_id}
260 # Verify subscriber access flows are added for the ONU port
261 Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
262 ... Verify Subscriber Access Flows Added For ONU ${ONOS_SSH_IP} ${ONOS_SSH_PORT} ${of_id}
263 ... ${onu_port} ${nni_port} ${src['c_tag']} ${src['s_tag']}
264 ${logoutput} Catenate \r\n[${I}] Verify Subscriber Access Flows Added For
265 ... ONU ${of_id} ${onu_port} ${src['c_tag']} ${src['s_tag']}.
266 Run Keyword If ${print2console} Log ${logoutput} console=yes
267 END
268
269Do Onu Subscriber Remove Per OLT
270 [Documentation] Removes per OLT subscribers in ONOS and Voltha
271 [Arguments] ${of_id} ${olt_serial_number} ${print2console}=False
272 FOR ${I} IN RANGE 0 ${num_all_onus}
273 ${src}= Set Variable ${hosts.src[${I}]}
274 ${dst}= Set Variable ${hosts.dst[${I}]}
275 Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
276 ${onu_device_id}= Get Device ID From SN ${src['onu']}
277 ${onu_port}= Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2s
278 ... Get ONU Port in ONOS ${src['onu']} ${of_id}
279 Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 2
280 ... Execute ONOS CLI Command use single connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
281 ... volt-remove-subscriber-access ${of_id} ${onu_port}
282 Run Keyword If ${print2console} Log \r\n[${I}] volt-remove-subscriber-access ${of_id} ${onu_port}.
283 ... console=yes
284 END
285
TorstenThieme7c397d72021-07-14 11:51:09 +0000286Validate Resource Instances Used Gem Ports
287 [Documentation] This keyword validates resource instances data stored in etcd.
288 ... It checks checks the number of gemport-ids which has matched with used Tech Profile
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000289 [Arguments] ${nbofgemports} ${namespace}=default ${defaultkvstoreprefix}=voltha_voltha
TorstenThieme7c397d72021-07-14 11:51:09 +0000290 ${kvstoreprefix}= Get Kv Store Prefix ${defaultkvstoreprefix}
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000291 ${etcddata}= Get ONU Go Adapter ETCD Data namespace=${namespace} defaultkvstoreprefix=${kvstoreprefix}
TorstenThieme7c397d72021-07-14 11:51:09 +0000292 #prepare result for json convert
293 ${result}= Prepare ONU Go Adapter ETCD Data For Json ${etcddata}
294 ${jsondata}= To Json ${result}
295 ${length}= Get Length ${jsondata}
296 log ${jsondata}
297 FOR ${INDEX} IN RANGE 0 ${length}
298 ${value}= Get From List ${jsondata} ${INDEX}
299 # TODO: The TP ID is hardcoded to 64 below. It is fine when testing single-tcont workflow.
300 # When testing multi-tcont this may need some adjustment.
301 Exit For Loop If not ('uni_config' in $value)
302 ${tp_path}= Get From Dictionary ${value['uni_config'][0]['PersTpPathMap']} 64
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000303 ${resourcedata}= Get Resource Instances ETCD Data ${tp_path} namespace=${namespace}
304 ... defaultkvstoreprefix=${kvstoreprefix}
TorstenThieme7c397d72021-07-14 11:51:09 +0000305 log ${resourcedata}
306 ${decoderesult}= volthatools.Tech Profile Decode Resource Instance ${resourcedata} return_default=true
307 log ${decoderesult}
308 ${gemportids}= Get From Dictionary ${decoderesult} gemport_ids
309 ${length}= Get Length ${gemportids}
310 Should Be Equal As Integers ${nbofgemports} ${length}
311 ... msg=Number of gem ports (${length}) does not match with techprofile ${techprofile}/${nbofgemports}
312 END
313
314Get Resource Instances ETCD Data
315 [Documentation] This keyword delivers Resource Instances Data stored in etcd
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000316 [Arguments] ${tppath} ${namespace}=default ${defaultkvstoreprefix}=voltha_voltha
TorstenThieme7c397d72021-07-14 11:51:09 +0000317 ${podname}= Set Variable etcd
318 ${kvstoreprefix}= Get Kv Store Prefix ${defaultkvstoreprefix}
319 ${commandget}= Catenate
320 ... /bin/sh -c 'ETCDCTL_API=3 etcdctl get --prefix service/${kvstoreprefix}/resource_instances/${tppath}
321 ... --print-value-only --hex'
322 ${result}= Exec Pod In Kube ${namespace} ${podname} ${commandget}
323 log ${result}
324 [Return] ${result}
325
326
TorstenThieme17756ea2020-11-11 14:09:47 +0000327Validate Onu Data In Etcd
328 [Documentation] This keyword validates openonu-go-adapter Data stored in etcd.
329 ... It checks unique of serial_number and combination of pon, onu and uni in tp_path.
330 ... Furthermore it evaluates the values of onu_id and uni_id with values read from tp_path.
331 ... Number of etcd entries has to match with the passed number.
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000332 [Arguments] ${namespace}=default ${nbofetcddata}=${num_all_onus} ${defaultkvstoreprefix}=voltha_voltha
TorstenThiemefa29a892021-03-11 14:11:29 +0000333 ... ${without_prefix}=True ${without_pm_data}=True
TorstenThieme3385cdc2021-02-04 13:50:50 +0000334 ${kvstoreprefix}= Get Kv Store Prefix ${defaultkvstoreprefix}
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000335 ${etcddata}= Get ONU Go Adapter ETCD Data ${namespace} ${kvstoreprefix} ${without_prefix} ${without_pm_data}
TorstenThieme17756ea2020-11-11 14:09:47 +0000336 #prepare result for json convert
337 ${result}= Prepare ONU Go Adapter ETCD Data For Json ${etcddata}
338 ${jsondata}= To Json ${result}
339 ${length}= Get Length ${jsondata}
340 log ${jsondata}
341 Run Keyword And Continue On Failure Should Be Equal As Integers ${length} ${nbofetcddata}
342 ... msg=Number etcd data (${length}) does not match required (${nbofetcddata})!
TorstenThiemefe7099e2021-01-29 08:41:04 +0000343 ${oltpononuuniidlist}= Create List
TorstenThieme17756ea2020-11-11 14:09:47 +0000344 ${serialnumberlist}= Create List
345 FOR ${INDEX} IN RANGE 0 ${length}
346 ${value}= Get From List ${jsondata} ${INDEX}
Girish Gowdra97f8d062020-11-17 15:48:23 -0800347 # TODO: The TP ID is hardcoded to 64 below. It is fine when testing single-tcont workflow.
348 # When testing multi-tcont this may need some adjustment.
TorstenThieme45071602021-03-16 12:14:37 +0000349 Exit For Loop If not ('uni_config' in $value)
Girish Gowdra97f8d062020-11-17 15:48:23 -0800350 ${tp_path}= Get From Dictionary ${value['uni_config'][0]['PersTpPathMap']} 64
TorstenThiemefe7099e2021-01-29 08:41:04 +0000351 ${oltpononuuniid}= Read Pon Onu Uni String ${tp_path}
352 ${list_id}= Get Index From List ${oltpononuuniidlist} ${oltpononuuniid}
TorstenThieme17756ea2020-11-11 14:09:47 +0000353 Should Be Equal As Integers ${list_id} -1
TorstenThiemefe7099e2021-01-29 08:41:04 +0000354 ... msg=Combination of Pon, Onu and Uni (${oltpononuuniid}) exist multiple in etcd data!
355 Append To List ${oltpononuuniidlist} ${oltpononuuniid}
TorstenThieme17756ea2020-11-11 14:09:47 +0000356 Validate Onu Id ${value}
357 Validate Uni Id ${value}
358 ${serial_number}= Get From Dictionary ${value} serial_number
359 ${list_id}= Get Index From List ${serialnumberlist} ${serial_number}
360 Should Be Equal As Integers ${list_id} -1
361 ... msg=Serial number (${serial_number}) exists multiple in etcd data!
362 Append To List ${serialnumberlist} ${serial_number}
363 END
364
TorstenThieme52ef8392020-11-10 13:42:26 +0000365Validate Vlan Rules In Etcd
366 [Documentation] This keyword validates Vlan rules of openonu-go-adapter Data stored in etcd.
367 ... It checks the given number of cookie_slice, match_vid (=4096) and set_vid.
368 ... Furthermore it returns a list of all set_vid.
369 ... In case of a passed dictionary containing set_vids these will be checked for to
370 ... current set-vid depending on setvidequal (True=equal, False=not equal).
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000371 [Arguments] ${namespace}=default ${nbofcookieslice}=1 ${reqmatchvid}=4096 ${prevvlanrules}=${NONE}
372 ... ${setvidequal}=False ${defaultkvstoreprefix}=voltha_voltha ${without_prefix}=True ${without_pm_data}=True
TorstenThieme3385cdc2021-02-04 13:50:50 +0000373 ${kvstoreprefix}= Get Kv Store Prefix ${defaultkvstoreprefix}
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000374 ${etcddata}= Get ONU Go Adapter ETCD Data ${namespace} ${kvstoreprefix} ${without_prefix} ${without_pm_data}
TorstenThieme52ef8392020-11-10 13:42:26 +0000375 #prepare result for json convert
376 ${result}= Prepare ONU Go Adapter ETCD Data For Json ${etcddata}
377 ${jsondata}= To Json ${result}
378 ${length}= Get Length ${jsondata}
379 log ${jsondata}
380 ${vlan_rules}= Create Dictionary
381 FOR ${INDEX} IN RANGE 0 ${length}
382 ${value}= Get From List ${jsondata} ${INDEX}
Girish Gowdra295c1692020-11-19 10:51:53 -0800383 # TODO: The TP ID is hardcoded to 64 below. It is fine when testing single-tcont workflow.
384 # When testing multi-tcont this may need some adjustment.
385 ${tp_path}= Get From Dictionary ${value['uni_config'][0]['PersTpPathMap']} 64
TorstenThiemefe7099e2021-01-29 08:41:04 +0000386 ${oltpononuuniid}= Read Pon Onu Uni String ${tp_path}
TorstenThieme52ef8392020-11-10 13:42:26 +0000387 ${cookieslice}= Get From Dictionary ${value['uni_config'][0]['flow_params'][0]} cookie_slice
388 #@{cookieslicelist}= Split String ${cookieslice} ,
389 ${foundcookieslices}= Get Length ${cookieslice}
390 Should Be Equal As Integers ${foundcookieslices} ${nbofcookieslice}
391 ${matchvid}= Get From Dictionary ${value['uni_config'][0]['flow_params'][0]['vlan_rule_params']}
392 ... match_vid
393 Should Be Equal As Integers ${matchvid} ${reqmatchvid}
394 ${setvid}= Get From Dictionary ${value['uni_config'][0]['flow_params'][0]['vlan_rule_params']}
395 ... set_vid
396 ${evalresult}= Evaluate 2 <= ${setvid} <= 4095
397 Should Be True ${evalresult} msg=set_vid out of range (${setvid})!
TorstenThiemefe7099e2021-01-29 08:41:04 +0000398 Set To Dictionary ${vlan_rules} ${oltpononuuniid} ${setvid}
TorstenThieme52ef8392020-11-10 13:42:26 +0000399 ${oldsetvidvalid} Set Variable If ${prevvlanrules} is ${NONE} False True
TorstenThiemefe7099e2021-01-29 08:41:04 +0000400 ${prevsetvid}= Set Variable If ${oldsetvidvalid} ${prevvlanrules['${oltpononuuniid}']}
TorstenThieme52ef8392020-11-10 13:42:26 +0000401 Run Keyword If ${oldsetvidvalid} and ${setvidequal}
402 ... Should Be Equal As Integers ${prevsetvid} ${setvid}
403 ... ELSE IF ${oldsetvidvalid} and not ${setvidequal}
404 ... Should Not Be Equal As Integers ${prevsetvid} ${setvid}
405 END
TorstenThieme440b7c02020-12-18 15:42:57 +0000406 log Many ${vlan_rules}
TorstenThieme52ef8392020-11-10 13:42:26 +0000407 [Return] ${vlan_rules}
408
409Get ONU Go Adapter ETCD Data
410 [Documentation] This keyword delivers openonu-go-adapter Data stored in etcd
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000411 [Arguments] ${namespace}=default ${defaultkvstoreprefix}=voltha_voltha ${without_prefix}=True
412 ... ${without_pm_data}=True
TorstenThieme52ef8392020-11-10 13:42:26 +0000413 ${podname}= Set Variable etcd
TorstenThieme3385cdc2021-02-04 13:50:50 +0000414 ${kvstoreprefix}= Get Kv Store Prefix ${defaultkvstoreprefix}
TorstenThieme3af12312021-03-10 16:15:24 +0000415 ${commandget}= Catenate
416 ... /bin/sh -c 'ETCDCTL_API=3 etcdctl get --prefix service/${kvstoreprefix}/openonu'
417 ${commandget}= Run Keyword If ${without_prefix} Catenate ${commandget}
418 ... | grep -v service/${kvstoreprefix}/openonu
TorstenThiemefa29a892021-03-11 14:11:29 +0000419 ... ELSE Set Variable ${commandget}
TorstenThieme3af12312021-03-10 16:15:24 +0000420 ${commandget}= Run Keyword If ${without_pm_data} Catenate ${commandget} | grep -v instances_active
TorstenThiemefa29a892021-03-11 14:11:29 +0000421 ... ELSE Set Variable ${commandget}
Holger Hildebrandt23147742020-11-16 10:13:21 +0000422 ${result}= Exec Pod In Kube ${namespace} ${podname} ${commandget}
TorstenThieme52ef8392020-11-10 13:42:26 +0000423 log ${result}
424 [Return] ${result}
425
426Prepare ONU Go Adapter ETCD Data For Json
427 [Documentation] This keyword prepares openonu-go-adapter Data stored in etcd for converting
428 ... to json
429 [Arguments] ${etcddata}
430 #prepare result for json convert
431 ${prepresult}= Replace String ${etcddata} \n ,
432 ${prepresult}= Strip String ${prepresult} mode=right characters=,
433 ${prepresult}= Set Variable [${prepresult}]
434 log ${prepresult}
435 [Return] ${prepresult}
436
TorstenThieme52ef8392020-11-10 13:42:26 +0000437Read Pon Onu Uni String
TorstenThiemefe7099e2021-01-29 08:41:04 +0000438 [Documentation] This keyword builds a four digit string using Olt, Pon, Onu and Uni value of given tp-path taken
TorstenThieme52ef8392020-11-10 13:42:26 +0000439 ... taken from etcd data of onu go adapter
440 [Arguments] ${tp_path}
TorstenThieme52ef8392020-11-10 13:42:26 +0000441 ${tppathlines}= Replace String ${tp_path} / \n
TorstenThiemefe7099e2021-01-29 08:41:04 +0000442 ${olt}= Get Value Of Tp Path Element ${tppathlines} olt
TorstenThieme52ef8392020-11-10 13:42:26 +0000443 ${pon}= Get Value Of Tp Path Element ${tppathlines} pon
444 ${onu}= Get Value Of Tp Path Element ${tppathlines} onu
445 ${uni}= Get Value Of Tp Path Element ${tppathlines} uni
TorstenThiemefe7099e2021-01-29 08:41:04 +0000446 ${valuesid}= Set Variable ${olt}/${pon}/${onu}/${uni}
TorstenThieme52ef8392020-11-10 13:42:26 +0000447 log ${valuesid}
448 [Return] ${valuesid}
449
450Get Value Of Tp Path Element
TorstenThieme17756ea2020-11-11 14:09:47 +0000451 [Documentation] This keyword delivers numeric value of given tp path element.
TorstenThieme52ef8392020-11-10 13:42:26 +0000452 [Arguments] ${tp_path_lines} ${element}
453 ${value}= Get Lines Containing String ${tp_path_lines} ${element}-\{
454 ${value}= Remove String ${value} ${element}-\{
455 ${value}= Remove String ${value} \}
456 log ${value}
457 [Return] ${value}
458
TorstenThieme17756ea2020-11-11 14:09:47 +0000459Validate Onu Id
460 [Documentation] This keyword validates ONU Id of passed etcd data.
461 [Arguments] ${value}
Girish Gowdra295c1692020-11-19 10:51:53 -0800462 # TODO: The TP ID is hardcoded to 64 below. It is fine when testing single-tcont workflow.
463 # When testing multi-tcont this may need some adjustment.
464 ${tp_path}= Get From Dictionary ${value['uni_config'][0]['PersTpPathMap']} 64
TorstenThieme17756ea2020-11-11 14:09:47 +0000465 ${tppathlines}= Replace String ${tp_path} / \n
466 ${onu}= Get Value Of Tp Path Element ${tppathlines} onu
467 ${onu_id}= Get From Dictionary ${value} onu_id
468 Should Be Equal As Integers ${onu} ${onu_id}
469 ... msg=Onu-Id (${onu_id}) does not match onu (${onu}) from tp_path in etcd data!
470 Should Be True ${onu_id}>=1
471
472Validate Uni Id
473 [Documentation] This keyword validates UNI Id of passed etcd data.
474 [Arguments] ${value}
Girish Gowdra295c1692020-11-19 10:51:53 -0800475 # TODO: The TP ID is hardcoded to 64 below. It is fine when testing single-tcont workflow.
476 # When testing multi-tcont this may need some adjustment.
477 ${tp_path}= Get From Dictionary ${value['uni_config'][0]['PersTpPathMap']} 64
TorstenThieme17756ea2020-11-11 14:09:47 +0000478 ${tppathlines}= Replace String ${tp_path} / \n
479 ${uni}= Get Value Of Tp Path Element ${tppathlines} uni
480 ${uni_id}= Get From Dictionary ${value['uni_config'][0]} uni_id
481 Should Be Equal As Integers ${uni} ${uni_id}
482 ... msg=Uni-Id (${uni_id}) does not match onu (${uni}) from tp_path in etcd data!
TorstenThieme52ef8392020-11-10 13:42:26 +0000483
TorstenThieme45071602021-03-16 12:14:37 +0000484Delete ONU Go Adapter ETCD Data
485 [Documentation] This keyword deletes openonu-go-adapter Data stored in etcd
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000486 [Arguments] ${namespace}=default ${defaultkvstoreprefix}=voltha_voltha ${validate}=False
TorstenThieme45071602021-03-16 12:14:37 +0000487 ${podname}= Set Variable etcd
488 ${kvstoreprefix}= Get Kv Store Prefix ${defaultkvstoreprefix}
489 ${commandget}= Catenate
490 ... /bin/sh -c 'ETCDCTL_API=3 etcdctl del --prefix service/${kvstoreprefix}/openonu'
491 ${result}= Exec Pod In Kube ${namespace} ${podname} ${commandget}
492 log ${result}
493 Run Keyword If ${validate} Wait Until Keyword Succeeds ${timeout} 1s
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000494 ... Validate Onu Data In Etcd namespace=${namespace} nbofetcddata=0 without_pm_data=False
TorstenThieme45071602021-03-16 12:14:37 +0000495 [Return] ${result}
496
TorstenThiemed4f48962020-12-08 12:17:19 +0000497Wait for Ports in ONOS for all OLTs
TorstenThieme440b7c02020-12-18 15:42:57 +0000498 [Documentation] Waits untill a certain number of ports are enabled in all OLTs
TorstenThieme731a7592021-07-01 14:26:54 +0000499 [Arguments] ${host} ${port} ${count} ${filter} ${max_wait_time}=10m ${determine_number}=False
TorstenThiemed4f48962020-12-08 12:17:19 +0000500 FOR ${J} IN RANGE 0 ${num_olts}
501 ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn]
502 ${onu_count}= Set Variable ${list_olts}[${J}][onucount]
503 ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS
504 ... ${olt_serial_number}
505 Set Global Variable ${of_id}
TorstenThiemeff9c9142021-04-08 07:21:34 +0000506 ${count2check}= Set Variable If ${count}==${num_all_onus} ${onu_count} ${count}
507 # if flag determine_number is set to True, always determine the number of real ONUs (overwrite previous value)
508 ${count2check}= Run Keyword If ${determine_number} Determine Number Of ONU ${olt_serial_number}
509 ... ELSE Set Variable ${count2check}
TorstenThieme731a7592021-07-01 14:26:54 +0000510 Wait for Ports in ONOS ${host} ${port} ${count2check} ${of_id} BBSM ${max_wait_time}
TorstenThiemed4f48962020-12-08 12:17:19 +0000511 END
512
TorstenThieme440b7c02020-12-18 15:42:57 +0000513Wait for all ONU Ports in ONOS Disabled
514 [Documentation] Waits untill a all ONU ports are disabled in all ONOS
TorstenThieme731a7592021-07-01 14:26:54 +0000515 [Arguments] ${host} ${port}
TorstenThieme440b7c02020-12-18 15:42:57 +0000516 FOR ${I} IN RANGE 0 ${num_all_onus}
517 ${src}= Set Variable ${hosts.src[${I}]}
518 ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS
519 ... ${src['olt']}
520 ${onu_port}= Wait Until Keyword Succeeds ${timeout} 2s Get ONU Port in ONOS ${src['onu']} ${of_id}
TorstenThieme731a7592021-07-01 14:26:54 +0000521 Wait Until Keyword Succeeds ${timeout} 2s Assert ONU Port Is Disabled ${host} ${port} ${of_id}
TorstenThieme440b7c02020-12-18 15:42:57 +0000522 ... ${onu_port}
523 END
524
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000525Map State
526 [Documentation] This keyword converts the passed numeric value or name of a onu state to its state values.
527 [Arguments] ${state}
528 # create state lists with corresponding return values
529 # ADMIN-STATE OPER-STATUS CONNECT-STATUS ONU-STATE (number/name)
530 ${state1} Create List ENABLED ACTIVATING REACHABLE 1 activating-onu
531 ${state2} Create List ENABLED ACTIVATING REACHABLE 2 starting-openomci
532 ${state3} Create List ENABLED ACTIVATING REACHABLE 3 discovery-mibsync-complete
533 ${state4} Create List ENABLED ACTIVE REACHABLE 4 initial-mib-downloaded
534 ${state5} Create List ENABLED ACTIVE REACHABLE 5 tech-profile-config-download-success
535 ${state6} Create List ENABLED ACTIVE REACHABLE 6 omci-flows-pushed
536 ${state7} Create List DISABLED UNKNOWN REACHABLE 7 omci-admin-lock
537 ${state8} Create List ENABLED ACTIVE REACHABLE 8 onu-reenabled
538 ${state9} Create List ENABLED DISCOVERED UNREACHABLE 9 stopping-openomci
539 ${state10} Create List ENABLED DISCOVERED REACHABLE 10 rebooting
540 ${state11} Create List ENABLED DISCOVERED REACHABLE 11 omci-flows-deleted
541 ${state12} Create List DISABLED UNKNOWN REACHABLE 12 tech-profile-config-delete-success
542 ${admin_state} ${oper_status} ${connect_status} ${onu_state_nb} ${onu_state}= Set Variable If
543 ... '${state}'=='1' or '${state}'=='activating-onu' ${state1}
544 ... '${state}'=='2' or '${state}'=='starting-openomci' ${state2}
545 ... '${state}'=='3' or '${state}'=='discovery-mibsync-complete' ${state3}
546 ... '${state}'=='4' or '${state}'=='initial-mib-downloaded' ${state4}
547 ... '${state}'=='5' or '${state}'=='tech-profile-config-download-success' ${state5}
548 ... '${state}'=='6' or '${state}'=='omci-flows-pushed' ${state6}
549 ... '${state}'=='7' or '${state}'=='omci-admin-lock' ${state7}
550 ... '${state}'=='8' or '${state}'=='onu-reenabled' ${state8}
551 ... '${state}'=='9' or '${state}'=='stopping-openomci' ${state9}
552 ... '${state}'=='10' or '${state}'=='rebooting' ${state10}
553 ... '${state}'=='11' or '${state}'=='omci-flows-deleted' ${state11}
554 ... '${state}'=='12' or '${state}'=='tech-profile-config-delete-success' ${state12}