blob: 11bfdb15c7521ae64b98791be71ce80b9b82e481 [file] [log] [blame]
TorstenThieme440b7c02020-12-18 15:42:57 +00001# Copyright 2020 - present Open Networking Foundation
2#
3# Licensed under the Apache License, Version 2.0 (the "License");
4# you may not use this file except in compliance with the License.
5# You may obtain a copy of the License at
6#
7# http://www.apache.org/licenses/LICENSE-2.0
8#
9# Unless required by applicable law or agreed to in writing, software
10# distributed under the License is distributed on an "AS IS" BASIS,
11# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
12# See the License for the specific language governing permissions and
13# limitations under the License.
14
15*** Settings ***
TorstenThiemec3c23232021-01-13 13:06:31 +000016Documentation Test different Reconcile scenarios of ONU Go adapter with all three workflows ATT, DT and TT.
TorstenThieme440b7c02020-12-18 15:42:57 +000017... Test suite is dedicated for only one ONU! Run robot with bbsim-kind.yaml only!
18... Not for DT/TT workflow!
19... Hint: default timeout in BBSim to mimic OLT reboot is 60 seconds!
20... This behaviour of BBSim can be modified by 'oltRebootDelay: 60' in BBSim section of helm chart or
21... used values.yaml during 'voltha up'.
22Suite Setup Setup Suite
23Suite Teardown Teardown Suite
24Test Setup Setup
25Test Teardown Teardown
26Library Collections
27Library String
28Library OperatingSystem
29Library XML
30Library RequestsLibrary
31Library ../../libraries/DependencyLibrary.py
32Resource ../../libraries/onos.robot
33Resource ../../libraries/voltctl.robot
34Resource ../../libraries/voltha.robot
35Resource ../../libraries/utils.robot
36Resource ../../libraries/k8s.robot
37Resource ../../libraries/onu_utilities.robot
38Resource ../../variables/variables.robot
39
40*** Variables ***
Hardik Windlass4288c6a2021-09-28 07:22:06 +000041${NAMESPACE} voltha
42${INFRA_NAMESPACE} default
TorstenThieme440b7c02020-12-18 15:42:57 +000043${timeout} 60s
44${of_id} 0
45${logical_id} 0
46${has_dataplane} True
47${external_libs} True
48${teardown_device} True
49${scripts} ../../scripts
50# Per-test logging on failure is turned off by default; set this variable to enable
51${container_log_dir} ${None}
52# flag for first test, needed due default timeout in BBSim to mimic OLT reboot of 60 seconds
53${firsttest} True
TorstenThiemec3c23232021-01-13 13:06:31 +000054# determines the environment workflow: DT, TT or ATT (default)
55# example: -v workflow:DT
56${workflow} ATT
TorstenThieme47983692021-06-17 10:43:35 +000057# KV Store Prefix
58# example: -v kvstoreprefix:voltha_voltha
59${kvstoreprefix} voltha_voltha
TorstenThieme440b7c02020-12-18 15:42:57 +000060# flag debugmode is used, if true timeout calculation various, can be passed via the command line too
61# example: -v debugmode:True
62${debugmode} False
63# logging flag to enable Collect Logs, can be passed via the command line too
64# example: -v logging:True
65${logging} False
66# if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline!
67# example: -v pausebeforecleanup:True
68${pausebeforecleanup} False
69# if True some outputs to console are done during running tests e.g. long duration flow test
70# example: -v print2console:True
71${print2console} False
72# if True (hard) kill will be used to restart onu adapter, else (soft) restart mechanism of k8s will be used
73# example: -v usekill2restart:True
74${usekill2restart} False
TorstenThieme45071602021-03-16 12:14:37 +000075# if True etcd check will be executed in test case teardown, if False etcd check will be executed in suite teardown
76# example: -v etcdcheckintestteardown:False
77${etcdcheckintestteardown} True
TorstenThieme440b7c02020-12-18 15:42:57 +000078${data_dir} ../data
TorstenThieme70bc5262021-01-19 12:12:55 +000079${suppressaddsubscriber} True
TorstenThieme440b7c02020-12-18 15:42:57 +000080
81
82*** Test Cases ***
83Reconcile In Starting-OpenOmci
84 [Documentation] Validates the Reconcile in Starting-OpenOmci
85 ... Reconcile test during starting-openomci in AT&T-workflow:
86 ... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store)
TorstenThiemec3c23232021-01-13 13:06:31 +000087 ... - wait for device reason starting-openomci
TorstenThieme440b7c02020-12-18 15:42:57 +000088 ... - kill the open-onu-adapter-go
TorstenThiemec3c23232021-01-13 13:06:31 +000089 ... - wait for open-onu-adapter-go to restart
90 ... - perform sanity test include add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +000091 ... - delete ONU and MIB-template in KV-store
92 [Tags] functionalOnuGo ReconcileStartingOpenOmciOnuGo
93 [Setup] Run Keywords Start Logging ReconcileStartingOpenOmciOnuGo
94 ... AND Setup Test
95 Run Keyword If ${has_dataplane} Clean Up Linux
TorstenThiemee9017be2021-03-05 16:59:31 +000096 Do Reconcile In Determined State starting-openomci
TorstenThieme3494ceb2021-07-19 09:47:24 +000097 [Teardown] Run Keywords Run Keyword If ${logging} Get Logical Id of OLT
98 ... AND Run Keyword If ${logging} Collect Logs
TorstenThieme440b7c02020-12-18 15:42:57 +000099 ... AND Teardown Test
100 ... AND Stop Logging ReconcileStartingOpenOmciOnuGo
101
102Reconcile In Initial-Mib-Downloaded
103 [Documentation] Validates the Reconcile in initial-mib-downloaded
104 ... Reconcile test during initial-mib-downloaded in AT&T-workflow:
105 ... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store)
TorstenThiemec3c23232021-01-13 13:06:31 +0000106 ... - wait for device reason initial-mib-downloaded
TorstenThieme440b7c02020-12-18 15:42:57 +0000107 ... - kill the open-onu-adapter-go
TorstenThiemec3c23232021-01-13 13:06:31 +0000108 ... - wait for open-onu-adapter-go to restart
109 ... - perform sanity test include add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000110 ... - delete ONU and MIB-template in KV-store
111 [Tags] functionalOnuGo ReconcileInitialMibDownloadedOnuGo
112 [Setup] Run Keywords Start Logging ReconcileInitialMibDownloadedOnuGo
113 ... AND Setup Test
114 Run Keyword If ${has_dataplane} Clean Up Linux
TorstenThiemee9017be2021-03-05 16:59:31 +0000115 Do Reconcile In Determined State initial-mib-downloaded
TorstenThieme3494ceb2021-07-19 09:47:24 +0000116 [Teardown] Run Keywords Run Keyword If ${logging} Get Logical Id of OLT
117 ... AND Run Keyword If ${logging} Collect Logs
TorstenThieme440b7c02020-12-18 15:42:57 +0000118 ... AND Teardown Test
119 ... AND Stop Logging ReconcileInitialMibDownloadedOnuGo
120
121Reconcile In Omci-Flows-Pushed
122 [Documentation] Validates the Reconcile in omci-flows-pushed
123 ... Former testcase: Reconcile Onu Device in Testsuite Voltha_ONUStateTest.robot
124 ... Reconcile test during omci-flows-pushed in AT&T-workflow:
125 ... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store)
TorstenThiemec3c23232021-01-13 13:06:31 +0000126 ... - perform sanity test include add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000127 ... - kill the open-onu-adapter-go
TorstenThiemec3c23232021-01-13 13:06:31 +0000128 ... - wait for open-onu-adapter-go to restart
129 ... - perform sanity test suppress add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000130 ... - disable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000131 ... - wait for device corresponding onu reason e.g. tech-profile-config-delete-success
132 ... - check UNI-ports disabled in ONOS
TorstenThieme440b7c02020-12-18 15:42:57 +0000133 ... - enable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000134 ... - perform sanity test suppress add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000135 ... - delete ONU and MIB-template in KV-store
136 [Tags] functionalOnuGo ReconcileOmciFlowsPushedOnuGo
137 [Setup] Run Keywords Start Logging ReconcileOmciFlowsPushedOnuGo
138 ... AND Setup Test
139 Run Keyword If ${has_dataplane} Clean Up Linux
TorstenThiemee9017be2021-03-05 16:59:31 +0000140 Do Reconcile In Omci-Flows-Pushed
TorstenThieme3494ceb2021-07-19 09:47:24 +0000141 [Teardown] Run Keywords Run Keyword If ${logging} Get Logical Id of OLT
142 ... AND Run Keyword If ${logging} Collect Logs
TorstenThieme440b7c02020-12-18 15:42:57 +0000143 ... AND Teardown Test
144 ... AND Stop Logging ReconcileOmciFlowsPushedOnuGo
145
146Reconcile For Disabled Onu Device
147 [Documentation] Validates the Reconcile for disabled Onu device
148 ... Reconcile test for disabled Onu device in AT&T-workflow:
149 ... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store)
TorstenThiemec3c23232021-01-13 13:06:31 +0000150 ... - perform sanity test include add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000151 ... - disable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000152 ... - wait for device corresponding onu reason e.g. tech-profile-config-delete-success
153 ... - check UNI-ports disabled in ONOS
154 ... - kill the open-onu-adapter-go
155 ... - wait for open-onu-adapter-go to restart
156 ... - check device reason is still the same before restart
TorstenThieme440b7c02020-12-18 15:42:57 +0000157 ... - enable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000158 ... - perform sanity test suppress add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000159 ... - delete ONU and MIB-template in KV-store
160 [Tags] functionalOnuGo ReconcileDisabledOnuDeviceOnuGo
161 [Setup] Run Keywords Start Logging ReconcileDisabledOnuDeviceOnuGo
162 ... AND Setup Test
163 Run Keyword If ${has_dataplane} Clean Up Linux
TorstenThiemee9017be2021-03-05 16:59:31 +0000164 Do Reconcile For Disabled Onu Device
TorstenThieme3494ceb2021-07-19 09:47:24 +0000165 [Teardown] Run Keywords Run Keyword If ${logging} Get Logical Id of OLT
166 ... AND Run Keyword If ${logging} Collect Logs
TorstenThieme440b7c02020-12-18 15:42:57 +0000167 ... AND Teardown Test
168 ... AND Stop Logging ReconcileDisabledOnuDeviceOnuGo
169
170*** Keywords ***
171Setup Suite
172 [Documentation] Set up the test suite
173 ${LogInfo}= Catenate
174 ... \r\nPassed arguments:
175 ... debugmode:${debugmode}, logging:${logging}, pausebeforecleanup:${pausebeforecleanup},
TorstenThieme47983692021-06-17 10:43:35 +0000176 ... print2console:${print2console}, usekill2restart:${usekill2restart}, workflow:${workflow},
177 ... kvstoreprefix:${kvstoreprefix}
TorstenThieme440b7c02020-12-18 15:42:57 +0000178 Log ${LogInfo} console=yes
179 Common Test Suite Setup
TorstenThieme440b7c02020-12-18 15:42:57 +0000180 # delete etcd MIB Template Data
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000181 Delete MIB Template Data ${INFRA_NAMESPACE}
TorstenThieme45071602021-03-16 12:14:37 +0000182 # delete etcd onu data
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000183 Delete ONU Go Adapter ETCD Data namespace=${INFRA_NAMESPACE} validate=True
TorstenThieme440b7c02020-12-18 15:42:57 +0000184
TorstenThieme70bc5262021-01-19 12:12:55 +0000185
TorstenThieme440b7c02020-12-18 15:42:57 +0000186Teardown Suite
187 [Documentation] Replaces the Suite Teardown in utils.robot.
188 ... Cleans up and checks all ONU ports disabled in ONOS.
189 ... Furthermore gives the possibility to pause the execution.
190 Run Keyword If ${pausebeforecleanup} Import Library Dialogs
191 Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up!
192 Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes
193 Run Keyword If ${teardown_device} Delete All Devices and Verify
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000194 Run Keyword If ${usekill2restart} Restart Pod By Label ${NAMESPACE} app adapter-open-onu
TorstenThieme45071602021-03-16 12:14:37 +0000195 Run Keyword Unless ${etcdcheckintestteardown} Wait Until Keyword Succeeds ${timeout} 1s
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000196 ... Validate Onu Data In Etcd ${INFRA_NAMESPACE} 0 ${kvstoreprefix} without_pm_data=False
TorstenThieme731a7592021-07-01 14:26:54 +0000197 Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} 0 BBSM ${timeout}
TorstenThieme440b7c02020-12-18 15:42:57 +0000198 Close All ONOS SSH Connections
199
200Setup Test
201 [Documentation] Pre-test Setup
202 #test for empty device list
203 Test Empty Device List
204 Run Keyword If ${has_dataplane} Wait Until Keyword Succeeds 120s 10s Openolt is Up
205 ... ${olt_ssh_ip} ${olt_user} ${olt_pass}
206 Run Keyword If ${has_dataplane} Sleep 60s
207 #restart open-onu pod to reset crash loop back off mechansim of kubenetes
TorstenThieme37165402021-09-03 11:39:40 +0000208 Run Keyword If "${firsttest}"=="False" and "${usekill2restart}"=="True"
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000209 ... Restart Pod By Label ${NAMESPACE} app adapter-open-onu
TorstenThieme440b7c02020-12-18 15:42:57 +0000210 Run Keyword If "${firsttest}"=="False" Sleep 35s
211 ${firsttest} Set Variable False
212 Set Suite Variable ${firsttest}
213 # Create a list of olt ids (logical and device_id)
214 ${olt_ids} Create List
215 FOR ${I} IN RANGE 0 ${num_olts}
216 #create/preprovision device
Andrea Campanella3dcce272021-01-15 16:04:47 +0100217 ${olt_device_id}= Run Keyword If "${list_olts}[${I}][type]" == "${None}"
TorstenThieme44136642021-02-12 13:41:17 +0000218 ... Create Device ${list_olts}[${I}][ip] ${list_olts}[${I}][oltport]
219 ... ELSE Create Device ${list_olts}[${I}][ip] ${list_olts}[${I}][oltport] ${list_olts}[${I}][type]
TorstenThieme440b7c02020-12-18 15:42:57 +0000220 ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn]
221 #validate olt states
222 Wait Until Keyword Succeeds ${timeout} 5s
Hardik Windlass8b446492021-06-10 06:25:23 +0000223 ... Validate OLT Device PREPROVISIONED UNKNOWN UNKNOWN ${olt_device_id} by_dev_id=True
TorstenThieme440b7c02020-12-18 15:42:57 +0000224 Sleep 5s
225 ${logical_id}= Get Logical Device ID From SN ${olt_serial_number}
226 ${olt} Create Dictionary device_id ${olt_device_id} logical_id ${logical_id}
227 ... of_id ${of_id} sn ${olt_serial_number}
228 Append To List ${olt_ids} ${olt}
229 END
230 Set Global Variable ${olt_ids}
231
232Teardown Test
233 [Documentation] Post-test Teardown
TorstenThieme45071602021-03-16 12:14:37 +0000234 Run Keyword If ${pausebeforecleanup} Import Library Dialogs
235 Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up!
236 Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes
TorstenThiemee9017be2021-03-05 16:59:31 +0000237 Run Keyword If ${teardown_device} Delete All Devices and Verify
TorstenThieme440b7c02020-12-18 15:42:57 +0000238 # delete etcd MIB Template Data
239 Delete MIB Template Data
TorstenThiemeb355eb62021-03-09 14:04:55 +0000240 # check etcd data are empty
TorstenThieme45071602021-03-16 12:14:37 +0000241 Run Keyword If ${etcdcheckintestteardown} Wait Until Keyword Succeeds ${timeout} 1s
Hardik Windlass4288c6a2021-09-28 07:22:06 +0000242 ... Validate Onu Data In Etcd ${INFRA_NAMESPACE} 0 ${kvstoreprefix} without_pm_data=False
TorstenThieme440b7c02020-12-18 15:42:57 +0000243 Sleep 5s
244
245Do Reconcile In Determined State
246 [Documentation] This keyword reconciles ONU device when passed reason is reached and
247 ... check the state afterwards.
248 ... Following steps will be executed:
249 ... - enable OLT device
250 ... - wait for passed openonu reason
251 ... - restart openonu adaptor
TorstenThiemec3c23232021-01-13 13:06:31 +0000252 ... - perform sanity test include add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000253 [Arguments] ${expected_onu_reason}
TorstenThiemec3c23232021-01-13 13:06:31 +0000254 ${admin_state} ${oper_status} ${connect_status} ${onu_state_nb} ${onu_state}= Map State
255 ... ${expected_onu_reason}
256 Should Be True ${onu_state_nb}<=5
257 ... Wrong expected onu reason ${expected_onu_reason}, must be lower than 'omci-flows-pushed'!
TorstenThieme440b7c02020-12-18 15:42:57 +0000258 FOR ${I} IN RANGE 0 ${num_olts}
259 #get olt serial number
260 ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn]
261 #validate olt states
262 ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
263 Enable Device ${olt_device_id}
264 END
265 Current State Test All Onus ${expected_onu_reason}
TorstenThieme96fe9ee2021-10-21 10:24:08 +0000266 Reconcile Onu Adapter ${NAMESPACE} ${usekill2restart} ACTIVE
TorstenThiemec3c23232021-01-13 13:06:31 +0000267 Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT
TorstenThieme136ebf72021-02-26 14:27:07 +0000268 ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT
TorstenThiemec3c23232021-01-13 13:06:31 +0000269 ... ELSE Perform Sanity Test
TorstenThieme440b7c02020-12-18 15:42:57 +0000270
271Do Reconcile For Disabled Onu Device
272 [Documentation] This keyword reconciles ONU device for a disabled onu device and
273 ... check the state afterwards.
274 ... Following steps will be executed:
275 ... - enable OLT device
TorstenThiemec3c23232021-01-13 13:06:31 +0000276 ... - perform sanity test include add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000277 ... - disable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000278 ... - wait for corresponding openonu reason
TorstenThieme440b7c02020-12-18 15:42:57 +0000279 ... - check UNI-ports disabled in ONOS
280 ... - restart openonu adaptor
281 ... - check openonu adaptor is ready again
TorstenThiemec3c23232021-01-13 13:06:31 +0000282 ... - check device reason is still before restart
TorstenThieme440b7c02020-12-18 15:42:57 +0000283 ... - enable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000284 ... - perform sanity test suppress add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000285 FOR ${I} IN RANGE 0 ${num_olts}
286 #get olt serial number
287 ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn]
288 #validate olt states
289 ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
290 Enable Device ${olt_device_id}
291 END
TorstenThiemec3c23232021-01-13 13:06:31 +0000292 Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT
TorstenThieme136ebf72021-02-26 14:27:07 +0000293 ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT
TorstenThiemec3c23232021-01-13 13:06:31 +0000294 ... ELSE Perform Sanity Test
TorstenThieme440b7c02020-12-18 15:42:57 +0000295 Disable Onu Device
TorstenThieme3871cf72021-01-21 14:11:57 +0000296 ${alternativeonustates}= Create List omci-flows-deleted
297 Run Keyword If "${workflow}"=="DT" Current State Test All Onus omci-admin-lock
298 ... ELSE IF "${workflow}"=="TT" Current State Test All Onus omci-admin-lock
299 ... ELSE Current State Test All Onus omci-admin-lock alternativeonustate=${alternativeonustates}
TorstenThieme96fe9ee2021-10-21 10:24:08 +0000300 Reconcile Onu Adapter ${NAMESPACE} ${usekill2restart} UNKNOWN
TorstenThieme3871cf72021-01-21 14:11:57 +0000301 Run Keyword If "${workflow}"=="DT" Current State Test All Onus omci-admin-lock
302 ... ELSE IF "${workflow}"=="TT" Current State Test All Onus omci-admin-lock
303 ... ELSE Current State Test All Onus omci-admin-lock alternativeonustate=${alternativeonustates}
TorstenThieme731a7592021-07-01 14:26:54 +0000304 Wait for all ONU Ports in ONOS Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
TorstenThieme440b7c02020-12-18 15:42:57 +0000305 Enable Onu Device
TorstenThieme70bc5262021-01-19 12:12:55 +0000306 Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT ${suppressaddsubscriber}
TorstenThieme136ebf72021-02-26 14:27:07 +0000307 ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT ${suppressaddsubscriber}
TorstenThieme70bc5262021-01-19 12:12:55 +0000308 ... ELSE Perform Sanity Test ${suppressaddsubscriber}
TorstenThieme440b7c02020-12-18 15:42:57 +0000309
310Do Reconcile In Omci-Flows-Pushed
311 [Documentation] This keyword reconciles ONU device in omci-flows-pushed and check the state afterwards.
312 ... Reconcile test during omci-flows-pushed in AT&T-workflow:
313 ... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store)
TorstenThiemec3c23232021-01-13 13:06:31 +0000314 ... - perform sanity test include add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000315 ... - kill the open-onu-adapter-go
TorstenThiemec3c23232021-01-13 13:06:31 +0000316 ... - wait for open-onu-adapter-go to restart
317 ... - perform sanity test suppress add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000318 ... - disable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000319 ... - wait for corresponding device reason
320 ... - check UNI-ports disabled in ONOS
TorstenThieme440b7c02020-12-18 15:42:57 +0000321 ... - enable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000322 ... - perform sanity test supress add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000323 FOR ${I} IN RANGE 0 ${num_olts}
324 #get olt serial number
325 ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn]
326 #validate olt states
327 ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
328 Enable Device ${olt_device_id}
329 END
TorstenThiemec3c23232021-01-13 13:06:31 +0000330 Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT
TorstenThieme136ebf72021-02-26 14:27:07 +0000331 ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT
TorstenThiemec3c23232021-01-13 13:06:31 +0000332 ... ELSE Perform Sanity Test
TorstenThieme96fe9ee2021-10-21 10:24:08 +0000333 Reconcile Onu Adapter ${NAMESPACE} ${usekill2restart} ACTIVE
TorstenThieme70bc5262021-01-19 12:12:55 +0000334 Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT ${suppressaddsubscriber}
TorstenThieme136ebf72021-02-26 14:27:07 +0000335 ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT ${suppressaddsubscriber}
TorstenThieme70bc5262021-01-19 12:12:55 +0000336 ... ELSE Perform Sanity Test ${suppressaddsubscriber}
TorstenThieme440b7c02020-12-18 15:42:57 +0000337 Disable Onu Device
TorstenThieme3871cf72021-01-21 14:11:57 +0000338 ${alternativeonustates}= Create List omci-flows-deleted
339 Run Keyword If "${workflow}"=="DT" Current State Test All Onus omci-admin-lock
340 ... ELSE IF "${workflow}"=="TT" Current State Test All Onus omci-admin-lock
341 ... ELSE Current State Test All Onus omci-admin-lock alternativeonustate=${alternativeonustates}
TorstenThieme731a7592021-07-01 14:26:54 +0000342 Wait for all ONU Ports in ONOS Disabled ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
TorstenThieme440b7c02020-12-18 15:42:57 +0000343 Enable Onu Device
TorstenThieme70bc5262021-01-19 12:12:55 +0000344 Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT ${suppressaddsubscriber}
TorstenThieme136ebf72021-02-26 14:27:07 +0000345 ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT ${suppressaddsubscriber}
TorstenThieme70bc5262021-01-19 12:12:55 +0000346 ... ELSE Perform Sanity Test ${suppressaddsubscriber}