TorstenThieme | d9cc06e | 2022-11-09 12:12:46 +0000 | [diff] [blame] | 1 | # Copyright 2022 - present Open Networking Foundation |
| 2 | # |
| 3 | # Licensed under the Apache License, Version 2.0 (the "License"); |
| 4 | # you may not use this file except in compliance with the License. |
| 5 | # You may obtain a copy of the License at |
| 6 | # |
| 7 | # http://www.apache.org/licenses/LICENSE-2.0 |
| 8 | # |
| 9 | # Unless required by applicable law or agreed to in writing, software |
| 10 | # distributed under the License is distributed on an "AS IS" BASIS, |
| 11 | # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| 12 | # See the License for the specific language governing permissions and |
| 13 | # limitations under the License. |
| 14 | |
| 15 | *** Settings *** |
| 16 | Documentation Test of open ONU error cases |
| 17 | ... The test suite validates special error scenarios of openonu_go_adapter |
| 18 | ... -- power off during mib download |
| 19 | ... -- power of during flow configuration |
| 20 | ... -- onu capabilities against configuration requirements priority queues |
| 21 | ... -- onu capabilities against configuration requirements tconts |
| 22 | ... see also VOL-4796 |
| 23 | ... In case of kafka pod runs in k8s cluster - kafka has to deploy with following EXTRA_HELM_FLAGS |
| 24 | ... --set externalAccess.enabled=true, |
| 25 | ... --set externalAccess.service.type=NodePort, |
| 26 | ... --set externalAccess.service.nodePorts[0]=${KAFKA_PORT}, |
| 27 | ... --set externalAccess.service.domain=${KAFKA_IP} |
| 28 | ... with e.g. service.domain=10.0.02.15 or 127.0.0.1 and service.nodePorts[0]=30201! |
| 29 | ... For voltha-infra prefix kafka. is needed e.g.: --set kafka.externalAccess.enabled=true |
| 30 | Suite Setup Setup Suite |
| 31 | Suite Teardown Teardown Suite |
| 32 | Test Setup Setup |
| 33 | Test Teardown Teardown |
| 34 | Library Collections |
| 35 | Library String |
| 36 | Library OperatingSystem |
| 37 | Library XML |
| 38 | Library RequestsLibrary |
| 39 | Library ../../libraries/DependencyLibrary.py |
| 40 | Resource ../../libraries/onos.robot |
| 41 | Resource ../../libraries/voltctl.robot |
| 42 | Resource ../../libraries/voltha.robot |
| 43 | Resource ../../libraries/utils.robot |
| 44 | Resource ../../libraries/k8s.robot |
| 45 | Resource ../../libraries/onu_utilities.robot |
| 46 | Resource ../../libraries/bbsim.robot |
| 47 | Resource ../../variables/variables.robot |
| 48 | |
| 49 | Library kafka_robot.KafkaClient log_level=DEBUG WITH NAME kafka |
| 50 | Library grpc_robot.VolthaTools WITH NAME volthatools |
| 51 | |
| 52 | |
| 53 | *** Variables *** |
| 54 | ${NAMESPACE} voltha |
| 55 | ${INFRA_NAMESPACE} default |
| 56 | ${timeout} 60s |
| 57 | ${of_id} 0 |
| 58 | ${logical_id} 0 |
| 59 | ${has_dataplane} True |
| 60 | ${external_libs} True |
| 61 | ${teardown_device} True |
| 62 | ${scripts} ../../scripts |
| 63 | # Per-test logging on failure is turned off by default; set this variable to enable |
| 64 | ${container_log_dir} ${None} |
| 65 | |
| 66 | # logging flag to enable Collect Logs, can be passed via the command line too |
| 67 | # example: -v logging:True |
| 68 | ${logging} False |
| 69 | # if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline! |
| 70 | # example: -v pausebeforecleanup:True |
| 71 | ${pausebeforecleanup} False |
| 72 | # flag for first test, needed due default timeout in BBSim to mimic OLT reboot of 60 seconds |
| 73 | ${firsttest} True |
| 74 | # determines the environment workflow: DT, TT or ATT (default) |
| 75 | # example: -v workflow:DT |
| 76 | ${workflow} ATT |
| 77 | # KV Store Prefix |
| 78 | # example: -v kvstoreprefix:voltha/voltha_voltha |
| 79 | ${kvstoreprefix} voltha/voltha_voltha |
| 80 | # when voltha is running in k8s port forwarding is needed |
| 81 | # example: -v PORT_FORWARDING:False |
| 82 | ${PORT_FORWARDING} True |
| 83 | # kafka ip e.g. ip of master host where k8s is running |
| 84 | # example: -v KAFKA_IP:10.0.2.15 |
| 85 | ${KAFKA_IP} 127.0.0.1 |
| 86 | # kafka port: port of kafka nodeport |
| 87 | # example: -v KAFKA_PORT:30201 |
| 88 | ${KAFKA_PORT} 30201 |
| 89 | # kafka service port: service port of kafka nodeport |
| 90 | # example: -v KAFKA_SVC_PORT:9094 |
| 91 | ${KAFKA_SVC_PORT} 9094 |
| 92 | # onu MIB audit interval |
| 93 | # example: -v ONU_MIB_AUDIT_INTERVAL:50s |
| 94 | ${ONU_MIB_AUDIT_INTERVAL} 60s |
| 95 | # MDS mitsmatches per ONU |
| 96 | # example: -v MDS_MISMATCHES_PER_ONU:2 |
| 97 | ${MDS_MISMATCHES_PER_ONU} 3 |
| 98 | # if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline! |
| 99 | # example: -v pausebeforecleanup:True |
| 100 | ${pausebeforecleanup} False |
| 101 | # if True some outputs to console are done during running tests e.g. long duration flow test |
| 102 | # example: -v print2console:True |
| 103 | ${print2console} False |
| 104 | ${suppressaddsubscriber} True |
| 105 | ${data_dir} ../data |
| 106 | |
| 107 | # flag to choose the subscriber provisioning command type in ONOS |
| 108 | # TT often provision a single services for a subscriber (eg: hsia, voip, ...) one after the other. |
| 109 | # if set to True, command used is "volt-add-subscriber-unitag" |
| 110 | # if set to False, comand used is "volt-add-subscriber-access" |
| 111 | ${unitag_sub} False |
| 112 | |
| 113 | *** Test Cases *** |
| 114 | Verify Power Off During MIB Downloading |
| 115 | [Documentation] Validates the ONU Go adapter regarding robustness in case of ONU power-off during MIB downloading |
| 116 | [Tags] functional PowerOffWhileMibDownload |
| 117 | [Setup] Run Keywords Start Logging PowerOffWhileMibDownload |
| 118 | ... AND Setup Test |
| 119 | FOR ${I} IN RANGE 0 ${num_olts} |
| 120 | #get olt serial number |
| 121 | ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| 122 | #validate olt states |
| 123 | ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number} |
| 124 | Enable Device ${olt_device_id} |
| 125 | END |
| 126 | Current State Test All Onus starting-openomci |
| 127 | Power Off ONU Device ${namespace} |
| 128 | Current State Test All Onus stopping-openomci |
| 129 | Power On ONU Device ${namespace} |
| 130 | Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT |
| 131 | ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT |
| 132 | ... ELSE Perform Sanity Test |
| 133 | [Teardown] Run Keywords Printout ONU Serial Number and Device Id print2console=${print2console} |
| 134 | ... AND Run Keyword If ${logging} Collect Logs |
| 135 | ... AND Delete All Devices and Verify |
| 136 | ... AND Delete MIB Template Data ${INFRA_NAMESPACE} |
| 137 | ... AND Stop Logging PowerOffWhileMibDownload |
| 138 | |
| 139 | Verify Power Off During Flow Configuration |
| 140 | [Documentation] Validates the ONU Go adapter regarding robustness in case of ONU power-off during flow configuration |
| 141 | ... see VOL-4828 |
| 142 | [Tags] functional PowerOffWhileFlowConfig |
| 143 | [Setup] Run Keywords Start Logging PowerOffWhileFlowConfig |
| 144 | ... AND Setup Test |
| 145 | FOR ${I} IN RANGE 0 ${num_olts} |
| 146 | #get olt serial number |
| 147 | ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| 148 | #validate olt states |
| 149 | ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number} |
| 150 | Enable Device ${olt_device_id} |
| 151 | END |
| 152 | ${state2test}= Set Variable If |
| 153 | ... "${workflow}"=="DT" initial-mib-downloaded |
| 154 | ... "${workflow}"=="TT" initial-mib-downloaded |
| 155 | ... "${workflow}"=="ATT" omci-flows-pushed |
| 156 | ... initial-mib-downloaded |
| 157 | Current State Test All Onus ${state2test} |
| 158 | FOR ${J} IN RANGE 0 ${num_olts} |
| 159 | ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| 160 | ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS |
| 161 | ... ${olt_serial_number} |
| 162 | Do Onu Subscriber Add Per OLT ${of_id} ${olt_serial_number} ${print2console} |
| 163 | END |
| 164 | Power Off ONU Device ${namespace} |
| 165 | Current State Test All Onus stopping-openomci |
| 166 | Power On ONU Device ${namespace} |
| 167 | Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT ${suppressaddsubscriber} |
| 168 | ... ELSE IF "${workflow}"=="TT" Perform Sanity Tests TT ${suppressaddsubscriber} |
| 169 | ... ELSE Perform Sanity Test ${suppressaddsubscriber} |
| 170 | [Teardown] Run Keywords Printout ONU Serial Number and Device Id print2console=${print2console} |
| 171 | ... AND Run Keyword If ${logging} Collect Logs |
| 172 | ... AND Delete All Devices and Verify |
| 173 | ... AND Delete MIB Template Data ${INFRA_NAMESPACE} |
| 174 | ... AND Stop Logging PowerOffWhileFlowConfig |
| 175 | |
| 176 | Verify ONU capabilities against configuration requirements Priority Queues |
| 177 | [Documentation] Validates the ONU capabilities against configuration requirements regarding number of priority queues. |
| 178 | ... Require more priority queues than ONU capabilities. Check for correct reason/state of ONU and kafka |
| 179 | ... message. |
| 180 | ... see VOL-4827 |
| 181 | [Tags] functional ONUCapabilitiesVsConfigReqPrioQueues |
| 182 | [Setup] Run Keywords Start Logging ONUCapabilitiesVsConfigReqPrioQueues |
| 183 | ... AND Set Tech Profile 1T17GEM-error-case-priority-queues |
| 184 | ... AND Setup Test |
| 185 | kafka.Records Clear |
| 186 | FOR ${I} IN RANGE 0 ${num_olts} |
| 187 | #get olt serial number |
| 188 | ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| 189 | #validate olt states |
| 190 | ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number} |
| 191 | Enable Device ${olt_device_id} |
| 192 | END |
| 193 | ${state2test}= Set Variable If |
| 194 | ... "${workflow}"=="DT" initial-mib-downloaded |
| 195 | ... "${workflow}"=="TT" initial-mib-downloaded |
| 196 | ... "${workflow}"=="ATT" stopping-openomci |
| 197 | ... initial-mib-downloaded |
| 198 | Current State Test All Onus ${state2test} |
| 199 | FOR ${J} IN RANGE 0 ${num_olts} |
| 200 | #in case of ATT no flows have to configured. leave loop |
| 201 | Exit For Loop If "${workflow}"=="ATT" |
| 202 | ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| 203 | ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS |
| 204 | ... ${olt_serial_number} |
| 205 | Do Onu Subscriber Add Per OLT ${of_id} ${olt_serial_number} ${print2console} |
| 206 | END |
| 207 | ${alternativeonustates}= Create List omci-flows-deleted |
| 208 | Current State Test All Onus stopping-openomci alternativeonustate=${alternativeonustates} |
| 209 | ${list_onu_device_id} Create List |
| 210 | Build ONU Device Id List ${list_onu_device_id} |
| 211 | ${event}= Set Variable ONU_CONFIG_FAILURE_MISSING_US_PRIORITY_QUEUE |
| 212 | Wait Until Keyword Succeeds ${timeout} 5s Validate Events All ONUs ${list_onu_device_id} ${event} |
| 213 | [Teardown] Run Keywords Printout ONU Serial Number and Device Id print2console=${print2console} |
| 214 | ... AND Run Keyword If ${logging} Collect Logs |
| 215 | ... AND Run Keyword If ${pausebeforecleanup} Import Library Dialogs |
| 216 | ... AND Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up! |
| 217 | ... AND Set Suite Variable ${TechProfile} ${EMPTY} |
| 218 | ... AND Remove Tech Profile ${INFRA_NAMESPACE} |
| 219 | ... AND Delete All Devices and Verify |
| 220 | ... AND Get ONU Go Adapter ETCD Data ${INFRA_NAMESPACE} ${kvstoreprefix} |
| 221 | ... AND Delete MIB Template Data ${INFRA_NAMESPACE} |
| 222 | ... AND Stop Logging ONUCapabilitiesVsConfigReqPrioQueues |
| 223 | |
| 224 | Verify ONU capabilities against configuration requirements TConts |
| 225 | [Documentation] Validates the ONU capabilities against configuration requirements regarding number of tconts. |
| 226 | ... Require more tconts than ONU capabilities. Check for correct reason/state of ONU and kafka message |
| 227 | ... VOL-4826 |
| 228 | ... Hint: Run this test case using bbsim-kind-multi-uni-tt.yaml! |
| 229 | [Tags] functionalMultiUni ONUCapabilitiesVsConfigReqTConts |
| 230 | [Setup] Run Keywords Start Logging ONUCapabilitiesVsConfigReqTConts |
| 231 | ... AND Set Tech Profile 1T1GEM-multi-instances ${INFRA_NAMESPACE} 64 |
| 232 | ... AND Set Tech Profile 1T1GEM-multi-instances ${INFRA_NAMESPACE} 65 |
| 233 | ... AND Set Tech Profile 1T1GEM-multi-instances ${INFRA_NAMESPACE} 66 |
| 234 | ... AND Setup Test |
| 235 | kafka.Records Clear |
| 236 | FOR ${I} IN RANGE 0 ${num_olts} |
| 237 | #get olt serial number |
| 238 | ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| 239 | #validate olt states |
| 240 | ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number} |
| 241 | Enable Device ${olt_device_id} |
| 242 | END |
| 243 | ${state2test}= Set Variable If |
| 244 | ... "${workflow}"=="DT" initial-mib-downloaded |
| 245 | ... "${workflow}"=="TT" initial-mib-downloaded |
| 246 | ... "${workflow}"=="ATT" omci-flows-pushed |
| 247 | ... initial-mib-downloaded |
| 248 | Current State Test All Onus ${state2test} |
| 249 | FOR ${J} IN RANGE 0 ${num_olts} |
| 250 | ${olt_serial_number}= Set Variable ${list_olts}[${J}][sn] |
| 251 | ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS |
| 252 | ... ${olt_serial_number} |
| 253 | Do Onu Subscriber Add Per OLT ${of_id} ${olt_serial_number} ${print2console} |
| 254 | END |
| 255 | ${alternativeonustates}= Create List omci-flows-deleted |
| 256 | Current State Test All Onus stopping-openomci alternativeonustate=${alternativeonustates} |
| 257 | ${list_onu_device_id} Create List |
| 258 | Build ONU Device Id List ${list_onu_device_id} |
| 259 | ${list_onu_device_id} Create List |
| 260 | Build ONU Device Id List ${list_onu_device_id} |
| 261 | ${event}= Set Variable ONU_CONFIG_FAILURE_MISSING_TCONT |
| 262 | Wait Until Keyword Succeeds ${timeout} 5s Validate Events All ONUs ${list_onu_device_id} ${event} |
| 263 | [Teardown] Run Keywords Printout ONU Serial Number and Device Id print2console=${print2console} |
| 264 | ... AND Run Keyword If ${logging} Collect Logs |
| 265 | ... AND Run Keyword If ${pausebeforecleanup} Import Library Dialogs |
| 266 | ... AND Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up! |
| 267 | ... AND Set Suite Variable ${TechProfile} ${EMPTY} |
| 268 | ... AND Remove Tech Profile ${INFRA_NAMESPACE} |
| 269 | ... AND Remove Tech Profile ${INFRA_NAMESPACE} 65 |
| 270 | ... AND Remove Tech Profile ${INFRA_NAMESPACE} 66 |
| 271 | ... AND Delete All Devices and Verify |
| 272 | ... AND Get ONU Go Adapter ETCD Data ${INFRA_NAMESPACE} ${kvstoreprefix} |
| 273 | ... AND Delete MIB Template Data ${INFRA_NAMESPACE} |
| 274 | ... AND Stop Logging ONUCapabilitiesVsConfigReqTConts |
| 275 | |
| 276 | *** Keywords *** |
| 277 | Setup Suite |
| 278 | [Documentation] Set up the test suite |
| 279 | Start Logging Setup or Teardown Setup-${SUITE NAME} |
| 280 | Common Test Suite Setup |
| 281 | ${switch_type}= Get Variable Value ${web_power_switch.type} |
| 282 | Run Keyword If "${switch_type}"!="" Set Global Variable ${powerswitch_type} ${switch_type} |
| 283 | # set ${kafka} depending on environment in case of port-forward is needed |
| 284 | ${rc} ${kafka}= Run Keyword If ${PORT_FORWARDING} Run and Return Rc and Output |
| 285 | ... kubectl get svc -n ${INFRA_NAMESPACE} | grep kafka-0-external | awk '{print $1}' |
| 286 | Run Keyword If ${PORT_FORWARDING} Should Not Be Empty ${kafka} Service kafka-0-external not found |
| 287 | # start port forwarding if needed (when voltha runs in k8s) |
| 288 | ${portFwdHandle} = Run Keyword If ${PORT_FORWARDING} Start Process |
| 289 | ... kubectl port-forward --address 0.0.0.0 --namespace default svc/${kafka} ${KAFKA_PORT}:${KAFKA_SVC_PORT} & |
| 290 | ... shell=true |
| 291 | Set Suite Variable ${portFwdHandle} |
| 292 | Sleep 5s |
| 293 | # open connection to read kafka bus |
| 294 | Wait Until Keyword Succeeds 3x 5s |
| 295 | ... kafka.Connection Open ${KAFKA_IP} ${KAFKA_PORT} voltha.events timestamp_from=0 |
| 296 | # delete etcd MIB Template Data |
| 297 | Delete MIB Template Data ${INFRA_NAMESPACE} |
| 298 | # delete etcd onu data |
| 299 | Delete ONU Go Adapter ETCD Data namespace=${INFRA_NAMESPACE} validate=True |
| 300 | Stop Logging Setup or Teardown Setup-${SUITE NAME} |
| 301 | |
| 302 | Teardown Suite |
| 303 | [Documentation] tear down the test suite |
| 304 | Run Keyword If ${pausebeforecleanup} Import Library Dialogs |
| 305 | Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up! |
| 306 | Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes |
| 307 | # close connection to kafka |
| 308 | kafka.Connection Close |
| 309 | # stop port forwarding if started |
| 310 | Run Keyword If ${PORT_FORWARDING} Terminate Process ${portFwdHandle} kill=true |
| 311 | # call common suite teardown |
| 312 | utils.Teardown Suite |
| 313 | # delete etcd MIB Template Data |
| 314 | Delete MIB Template Data ${INFRA_NAMESPACE} |
| 315 | # delete etcd onu data |
| 316 | Delete ONU Go Adapter ETCD Data namespace=${INFRA_NAMESPACE} validate=True |
| 317 | Close All ONOS SSH Connections |
| 318 | |
| 319 | Setup Test |
| 320 | [Documentation] Pre-test Setup |
| 321 | #test for empty device list |
| 322 | Test Empty Device List |
| 323 | Run Keyword If ${has_dataplane} Wait Until Keyword Succeeds 120s 10s Openolt is Up |
| 324 | ... ${olt_ssh_ip} ${olt_user} ${olt_pass} |
| 325 | Run Keyword If ${has_dataplane} Sleep 60s |
| 326 | Run Keyword If "${firsttest}"=="False" Sleep 35s |
| 327 | ${firsttest} Set Variable False |
| 328 | Set Suite Variable ${firsttest} |
| 329 | # Create a list of olt ids (logical and device_id) |
| 330 | ${olt_ids} Create List |
| 331 | FOR ${I} IN RANGE 0 ${num_olts} |
| 332 | #create/preprovision device |
| 333 | ${olt_device_id}= Run Keyword If "${list_olts}[${I}][type]" == "${None}" |
| 334 | ... Create Device ${list_olts}[${I}][ip] ${list_olts}[${I}][oltport] |
| 335 | ... ELSE Create Device ${list_olts}[${I}][ip] ${list_olts}[${I}][oltport] ${list_olts}[${I}][type] |
| 336 | ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn] |
| 337 | #validate olt states |
| 338 | Wait Until Keyword Succeeds ${timeout} 5s |
| 339 | ... Validate OLT Device PREPROVISIONED UNKNOWN UNKNOWN ${olt_device_id} by_dev_id=True |
| 340 | Sleep 5s |
| 341 | ${logical_id}= Get Logical Device ID From SN ${olt_serial_number} |
| 342 | ${olt} Create Dictionary device_id ${olt_device_id} logical_id ${logical_id} |
| 343 | ... of_id ${of_id} sn ${olt_serial_number} |
| 344 | Append To List ${olt_ids} ${olt} |
| 345 | END |
| 346 | Set Global Variable ${olt_ids} |