blob: f17ec635fba93b50c70e045c8887e109b854c09c [file] [log] [blame]
TorstenThieme53450ff2021-05-11 09:44:33 +00001# Copyright 2021 - present Open Networking Foundation
2#
3# Licensed under the Apache License, Version 2.0 (the "License");
4# you may not use this file except in compliance with the License.
5# You may obtain a copy of the License at
6#
7# http://www.apache.org/licenses/LICENSE-2.0
8#
9# Unless required by applicable law or agreed to in writing, software
10# distributed under the License is distributed on an "AS IS" BASIS,
11# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
12# See the License for the specific language governing permissions and
13# limitations under the License.
14
15*** Settings ***
16Documentation Negative test states of ONU Go adapter with ATT workflows only (not for DT/TT workflow!)
17Suite Setup Setup Suite
18Suite Teardown Teardown Suite
19Test Setup Setup
20Test Teardown Teardown
21Library Collections
22Library String
23Library OperatingSystem
24Library XML
25Library RequestsLibrary
26Library ../../libraries/DependencyLibrary.py
27Resource ../../libraries/onos.robot
28Resource ../../libraries/voltctl.robot
29Resource ../../libraries/voltha.robot
30Resource ../../libraries/utils.robot
31Resource ../../libraries/k8s.robot
32Resource ../../libraries/onu_utilities.robot
33Resource ../../libraries/bbsim.robot
34Resource ../../variables/variables.robot
35
36*** Variables ***
37${namespace} voltha
Hardik Windlassa9b38262021-10-27 08:14:22 +000038${INFRA_NAMESPACE} default
TorstenThieme53450ff2021-05-11 09:44:33 +000039${timeout} 300s
40${of_id} 0
41${logical_id} 0
42${has_dataplane} True
43${external_libs} True
44${teardown_device} True
45${scripts} ../../scripts
46# Per-test logging on failure is turned off by default; set this variable to enable
47${container_log_dir} ${None}
48# KV Store Prefix
49# example: -v kvstoreprefix:voltha_voltha
50${kvstoreprefix} voltha_voltha
51# used tech profile, can be passed via the command line too, valid values: default (=1T1GEM), 1T4GEM, 1T8GEM
52# example: -v techprofile:1T4GEM
53${techprofile} default
54# flag debugmode is used, if true timeout calculation various, can be passed via the command line too
55# example: -v debugmode:True
56${debugmode} False
57# logging flag to enable Collect Logs, can be passed via the command line too
58# example: -v logging:True
59${logging} False
60# if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline!
61# example: -v pausebeforecleanup:True
62${pausebeforecleanup} False
63# if True some outputs to console are done during running tests e.g. long duration flow test
64# example: -v print2console:True
65${print2console} False
66${data_dir} ../data
67
68
69*** Test Cases ***
70ONU Negative State Test
71 [Documentation] Validates the ONU Go adapter states will never leave starting-openomci
72 ... Due to a 'omci-response-rate' lower than 8 more OMCI messages will be through away by BBSIM than
73 ... repeated by openonu-go-adapter. So ONU will never leave starting-openomci state.
74 ... Timeout has to set at least to 300s (or more)
75 [Tags] NegativeStateTestOnuGo
76 [Setup] Run Keywords Start Logging ONUNegativeStateTest
77 ... AND Setup
78 # Suite Variable will be overwritten by Teardown of Current State Test All Onus
79 Set Suite Variable ${StateTestAllONUs} True
80 ${seconds}= Convert Time ${timeout}
81 ${seconds}= Convert To String ${seconds}
82 ${seconds}= Get Substring ${seconds} 0 -2
83 FOR ${I} IN RANGE ${seconds}
84 Sleep 1s
85 Current State Test All Onus starting-openomci timeout=1x
86 Exit For Loop If not ${StateTestAllONUs}
87 END
88 [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
89 ... AND Stop Logging ONUStateTest
90
91
92*** Keywords ***
93Setup Suite
94 [Documentation] Set up the test suite
95 ${LogInfo}= Catenate
96 ... \r\nPassed arguments:
97 ... techprofile:${techprofile},
98 ... debugmode:${debugmode}, logging:${logging}, pausebeforecleanup:${pausebeforecleanup},
99 ... print2console:${print2console}
100 Log ${LogInfo} console=yes
101 Common Test Suite Setup
102 ${techprofile}= Set Variable If "${techprofile}"=="1T1GEM" default ${techprofile}
103 Set Suite Variable ${techprofile}
104 Run Keyword If "${techprofile}"=="default" Log To Console \nTechProfile:default (1T1GEM)
105 ... ELSE IF "${techprofile}"=="1T4GEM" Set Tech Profile 1T4GEM
106 ... ELSE IF "${techprofile}"=="1T8GEM" Set Tech Profile 1T8GEM
107 ... ELSE Fail The TechProfile (${techprofile}) is not valid!
TorstenThieme53450ff2021-05-11 09:44:33 +0000108 # delete etcd MIB Template Data
109 Delete MIB Template Data
110 # delete etcd onu data
111 Delete ONU Go Adapter ETCD Data validate=True
112
113Teardown Suite
114 [Documentation] Replaces the Suite Teardown in utils.robot.
115 ... Cleans up and checks all ONU ports disabled in ONOS.
116 ... Furthermore gives the possibility to pause the execution.
117 Run Keyword If ${pausebeforecleanup} Import Library Dialogs
118 Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up!
119 Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes
120 Run Keyword If ${teardown_device} Delete All Devices and Verify
121 Wait Until Keyword Succeeds ${timeout} 1s Validate Onu Data In Etcd 0 ${kvstoreprefix} without_pm_data=False
TorstenThieme731a7592021-07-01 14:26:54 +0000122 Wait for Ports in ONOS for all OLTs ${ONOS_SSH_IP} ${ONOS_SSH_PORT} 0 BBSM ${timeout}
TorstenThieme53450ff2021-05-11 09:44:33 +0000123 Close All ONOS SSH Connections
124 Remove Tech Profile