blob: 9b3c80ae10363b0d7bb833cbcdc964bec6f6fecf [file] [log] [blame]
TorstenThieme440b7c02020-12-18 15:42:57 +00001# Copyright 2020 - present Open Networking Foundation
2#
3# Licensed under the Apache License, Version 2.0 (the "License");
4# you may not use this file except in compliance with the License.
5# You may obtain a copy of the License at
6#
7# http://www.apache.org/licenses/LICENSE-2.0
8#
9# Unless required by applicable law or agreed to in writing, software
10# distributed under the License is distributed on an "AS IS" BASIS,
11# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
12# See the License for the specific language governing permissions and
13# limitations under the License.
14
15*** Settings ***
TorstenThiemec3c23232021-01-13 13:06:31 +000016Documentation Test different Reconcile scenarios of ONU Go adapter with all three workflows ATT, DT and TT.
TorstenThieme440b7c02020-12-18 15:42:57 +000017... Test suite is dedicated for only one ONU! Run robot with bbsim-kind.yaml only!
18... Not for DT/TT workflow!
19... Hint: default timeout in BBSim to mimic OLT reboot is 60 seconds!
20... This behaviour of BBSim can be modified by 'oltRebootDelay: 60' in BBSim section of helm chart or
21... used values.yaml during 'voltha up'.
22Suite Setup Setup Suite
23Suite Teardown Teardown Suite
24Test Setup Setup
25Test Teardown Teardown
26Library Collections
27Library String
28Library OperatingSystem
29Library XML
30Library RequestsLibrary
31Library ../../libraries/DependencyLibrary.py
32Resource ../../libraries/onos.robot
33Resource ../../libraries/voltctl.robot
34Resource ../../libraries/voltha.robot
35Resource ../../libraries/utils.robot
36Resource ../../libraries/k8s.robot
37Resource ../../libraries/onu_utilities.robot
38Resource ../../variables/variables.robot
39
40*** Variables ***
41${namespace} voltha
42${timeout} 60s
43${of_id} 0
44${logical_id} 0
45${has_dataplane} True
46${external_libs} True
47${teardown_device} True
48${scripts} ../../scripts
49# Per-test logging on failure is turned off by default; set this variable to enable
50${container_log_dir} ${None}
51# flag for first test, needed due default timeout in BBSim to mimic OLT reboot of 60 seconds
52${firsttest} True
TorstenThiemec3c23232021-01-13 13:06:31 +000053# determines the environment workflow: DT, TT or ATT (default)
54# example: -v workflow:DT
55${workflow} ATT
TorstenThieme440b7c02020-12-18 15:42:57 +000056# flag debugmode is used, if true timeout calculation various, can be passed via the command line too
57# example: -v debugmode:True
58${debugmode} False
59# logging flag to enable Collect Logs, can be passed via the command line too
60# example: -v logging:True
61${logging} False
62# if True execution will be paused before clean up, only use in case of manual testing, do not use in ci pipeline!
63# example: -v pausebeforecleanup:True
64${pausebeforecleanup} False
65# if True some outputs to console are done during running tests e.g. long duration flow test
66# example: -v print2console:True
67${print2console} False
68# if True (hard) kill will be used to restart onu adapter, else (soft) restart mechanism of k8s will be used
69# example: -v usekill2restart:True
70${usekill2restart} False
71${data_dir} ../data
TorstenThieme70bc5262021-01-19 12:12:55 +000072${suppressaddsubscriber} True
TorstenThieme440b7c02020-12-18 15:42:57 +000073
74
75*** Test Cases ***
76Reconcile In Starting-OpenOmci
77 [Documentation] Validates the Reconcile in Starting-OpenOmci
78 ... Reconcile test during starting-openomci in AT&T-workflow:
79 ... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store)
TorstenThiemec3c23232021-01-13 13:06:31 +000080 ... - wait for device reason starting-openomci
TorstenThieme440b7c02020-12-18 15:42:57 +000081 ... - kill the open-onu-adapter-go
TorstenThiemec3c23232021-01-13 13:06:31 +000082 ... - wait for open-onu-adapter-go to restart
83 ... - perform sanity test include add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +000084 ... - delete ONU and MIB-template in KV-store
85 [Tags] functionalOnuGo ReconcileStartingOpenOmciOnuGo
86 [Setup] Run Keywords Start Logging ReconcileStartingOpenOmciOnuGo
87 ... AND Setup Test
88 Run Keyword If ${has_dataplane} Clean Up Linux
TorstenThieme70bc5262021-01-19 12:12:55 +000089 Run Keyword If ${no_skip}
TorstenThieme440b7c02020-12-18 15:42:57 +000090 ... Do Reconcile In Determined State starting-openomci
91 ... ELSE Pass Execution ${skip_message} skipped
92 [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
93 ... AND Teardown Test
94 ... AND Stop Logging ReconcileStartingOpenOmciOnuGo
95
96Reconcile In Initial-Mib-Downloaded
97 [Documentation] Validates the Reconcile in initial-mib-downloaded
98 ... Reconcile test during initial-mib-downloaded in AT&T-workflow:
99 ... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store)
TorstenThiemec3c23232021-01-13 13:06:31 +0000100 ... - wait for device reason initial-mib-downloaded
TorstenThieme440b7c02020-12-18 15:42:57 +0000101 ... - kill the open-onu-adapter-go
TorstenThiemec3c23232021-01-13 13:06:31 +0000102 ... - wait for open-onu-adapter-go to restart
103 ... - perform sanity test include add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000104 ... - delete ONU and MIB-template in KV-store
105 [Tags] functionalOnuGo ReconcileInitialMibDownloadedOnuGo
106 [Setup] Run Keywords Start Logging ReconcileInitialMibDownloadedOnuGo
107 ... AND Setup Test
108 Run Keyword If ${has_dataplane} Clean Up Linux
TorstenThieme70bc5262021-01-19 12:12:55 +0000109 Run Keyword If ${no_skip}
TorstenThieme440b7c02020-12-18 15:42:57 +0000110 ... Do Reconcile In Determined State initial-mib-downloaded
111 ... ELSE Pass Execution ${skip_message} skipped
112 [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
113 ... AND Teardown Test
114 ... AND Stop Logging ReconcileInitialMibDownloadedOnuGo
115
116Reconcile In Omci-Flows-Pushed
117 [Documentation] Validates the Reconcile in omci-flows-pushed
118 ... Former testcase: Reconcile Onu Device in Testsuite Voltha_ONUStateTest.robot
119 ... Reconcile test during omci-flows-pushed in AT&T-workflow:
120 ... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store)
TorstenThiemec3c23232021-01-13 13:06:31 +0000121 ... - perform sanity test include add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000122 ... - kill the open-onu-adapter-go
TorstenThiemec3c23232021-01-13 13:06:31 +0000123 ... - wait for open-onu-adapter-go to restart
124 ... - perform sanity test suppress add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000125 ... - disable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000126 ... - wait for device corresponding onu reason e.g. tech-profile-config-delete-success
127 ... - check UNI-ports disabled in ONOS
TorstenThieme440b7c02020-12-18 15:42:57 +0000128 ... - enable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000129 ... - perform sanity test suppress add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000130 ... - delete ONU and MIB-template in KV-store
131 [Tags] functionalOnuGo ReconcileOmciFlowsPushedOnuGo
132 [Setup] Run Keywords Start Logging ReconcileOmciFlowsPushedOnuGo
133 ... AND Setup Test
134 Run Keyword If ${has_dataplane} Clean Up Linux
TorstenThieme70bc5262021-01-19 12:12:55 +0000135 Run Keyword If ${no_skip}
TorstenThieme440b7c02020-12-18 15:42:57 +0000136 ... Do Reconcile In Omci-Flows-Pushed
137 ... ELSE Pass Execution ${skip_message} skipped
138 [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
139 ... AND Teardown Test
140 ... AND Stop Logging ReconcileOmciFlowsPushedOnuGo
141
142Reconcile For Disabled Onu Device
143 [Documentation] Validates the Reconcile for disabled Onu device
144 ... Reconcile test for disabled Onu device in AT&T-workflow:
145 ... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store)
TorstenThiemec3c23232021-01-13 13:06:31 +0000146 ... - perform sanity test include add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000147 ... - disable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000148 ... - wait for device corresponding onu reason e.g. tech-profile-config-delete-success
149 ... - check UNI-ports disabled in ONOS
150 ... - kill the open-onu-adapter-go
151 ... - wait for open-onu-adapter-go to restart
152 ... - check device reason is still the same before restart
TorstenThieme440b7c02020-12-18 15:42:57 +0000153 ... - enable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000154 ... - perform sanity test suppress add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000155 ... - delete ONU and MIB-template in KV-store
156 [Tags] functionalOnuGo ReconcileDisabledOnuDeviceOnuGo
157 [Setup] Run Keywords Start Logging ReconcileDisabledOnuDeviceOnuGo
158 ... AND Setup Test
159 Run Keyword If ${has_dataplane} Clean Up Linux
TorstenThieme70bc5262021-01-19 12:12:55 +0000160 Run Keyword If ${no_skip}
TorstenThieme440b7c02020-12-18 15:42:57 +0000161 ... Do Reconcile For Disabled Onu Device
162 ... ELSE Pass Execution ${skip_message} skipped
163 [Teardown] Run Keywords Run Keyword If ${logging} Collect Logs
164 ... AND Teardown Test
165 ... AND Stop Logging ReconcileDisabledOnuDeviceOnuGo
166
167*** Keywords ***
168Setup Suite
169 [Documentation] Set up the test suite
170 ${LogInfo}= Catenate
171 ... \r\nPassed arguments:
172 ... debugmode:${debugmode}, logging:${logging}, pausebeforecleanup:${pausebeforecleanup},
TorstenThiemec3c23232021-01-13 13:06:31 +0000173 ... print2console:${print2console}, usekill2restart:${usekill2restart}, workflow:${workflow}
TorstenThieme440b7c02020-12-18 15:42:57 +0000174 Log ${LogInfo} console=yes
175 Common Test Suite Setup
TorstenThieme70bc5262021-01-19 12:12:55 +0000176 # determine real number of onus
177 ${num_real_onus}= Determine Number Of ONU
178 ${no_skip}= Set Variable If '${num_real_onus}'=='1' True False
179 Set Suite Variable ${no_skip}
TorstenThieme440b7c02020-12-18 15:42:57 +0000180 # prepare skip message in yellow for console log
181 ${skip}= Evaluate "\\033[33mSKIP\\033[0m"
TorstenThieme70bc5262021-01-19 12:12:55 +0000182 ${skipping}= Evaluate
183 ... "\\033[33m${SPACE*5} ===> Test case above was skipped! Too much ONUs (${num_real_onus})! <=== ${SPACE*5}\\033[0m"
184 ${skip_message} Catenate ${skipping} | ${skip} |
TorstenThieme440b7c02020-12-18 15:42:57 +0000185 Set Suite Variable ${skip_message}
186 ${onos_ssh_connection} Open ONOS SSH Connection ${ONOS_SSH_IP} ${ONOS_SSH_PORT}
187 Set Suite Variable ${onos_ssh_connection}
188 # delete etcd MIB Template Data
189 Delete MIB Template Data
190
TorstenThieme70bc5262021-01-19 12:12:55 +0000191
TorstenThieme440b7c02020-12-18 15:42:57 +0000192Teardown Suite
193 [Documentation] Replaces the Suite Teardown in utils.robot.
194 ... Cleans up and checks all ONU ports disabled in ONOS.
195 ... Furthermore gives the possibility to pause the execution.
196 Run Keyword If ${pausebeforecleanup} Import Library Dialogs
197 Run Keyword If ${pausebeforecleanup} Pause Execution Press OK to continue with clean up!
198 Run Keyword If ${pausebeforecleanup} Log Teardown will be continued... console=yes
199 Run Keyword If ${teardown_device} Delete All Devices and Verify
200 Run Keyword If ${usekill2restart} Restart Pod ${namespace} open-onu
201 Validate Onu Data In Etcd 0
202 Wait for Ports in ONOS for all OLTs ${onos_ssh_connection} 0 BBSM ${timeout}
203 Close All ONOS SSH Connections
204
205Setup Test
206 [Documentation] Pre-test Setup
207 #test for empty device list
208 Test Empty Device List
209 Run Keyword If ${has_dataplane} Wait Until Keyword Succeeds 120s 10s Openolt is Up
210 ... ${olt_ssh_ip} ${olt_user} ${olt_pass}
211 Run Keyword If ${has_dataplane} Sleep 60s
212 #restart open-onu pod to reset crash loop back off mechansim of kubenetes
213 Run Keyword If "${firsttest}"=="False" and "${usekill2restart}"=="True" Restart Pod ${namespace} open-onu
214 Run Keyword If "${firsttest}"=="False" Sleep 35s
215 ${firsttest} Set Variable False
216 Set Suite Variable ${firsttest}
217 # Create a list of olt ids (logical and device_id)
218 ${olt_ids} Create List
219 FOR ${I} IN RANGE 0 ${num_olts}
220 #create/preprovision device
Andrea Campanella3dcce272021-01-15 16:04:47 +0100221 ${olt_device_id}= Run Keyword If "${list_olts}[${I}][type]" == "${None}"
TorstenThieme44136642021-02-12 13:41:17 +0000222 ... Create Device ${list_olts}[${I}][ip] ${list_olts}[${I}][oltport]
223 ... ELSE Create Device ${list_olts}[${I}][ip] ${list_olts}[${I}][oltport] ${list_olts}[${I}][type]
TorstenThieme440b7c02020-12-18 15:42:57 +0000224 ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn]
225 #validate olt states
226 Wait Until Keyword Succeeds ${timeout} 5s
227 ... Validate OLT Device PREPROVISIONED UNKNOWN UNKNOWN ${olt_device_id}
228 Sleep 5s
229 ${logical_id}= Get Logical Device ID From SN ${olt_serial_number}
230 ${olt} Create Dictionary device_id ${olt_device_id} logical_id ${logical_id}
231 ... of_id ${of_id} sn ${olt_serial_number}
232 Append To List ${olt_ids} ${olt}
233 END
234 Set Global Variable ${olt_ids}
235
236Teardown Test
237 [Documentation] Post-test Teardown
TorstenThieme70bc5262021-01-19 12:12:55 +0000238 Run Keyword If ${teardown_device} and ${no_skip} Delete All Devices and Verify
239 ... ELSE IF ${teardown_device} Delete Devices In Voltha Root=true
TorstenThieme440b7c02020-12-18 15:42:57 +0000240 # delete etcd MIB Template Data
241 Delete MIB Template Data
242 Sleep 5s
243
244Do Reconcile In Determined State
245 [Documentation] This keyword reconciles ONU device when passed reason is reached and
246 ... check the state afterwards.
247 ... Following steps will be executed:
248 ... - enable OLT device
249 ... - wait for passed openonu reason
250 ... - restart openonu adaptor
TorstenThiemec3c23232021-01-13 13:06:31 +0000251 ... - perform sanity test include add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000252 [Arguments] ${expected_onu_reason}
TorstenThiemec3c23232021-01-13 13:06:31 +0000253 ${admin_state} ${oper_status} ${connect_status} ${onu_state_nb} ${onu_state}= Map State
254 ... ${expected_onu_reason}
255 Should Be True ${onu_state_nb}<=5
256 ... Wrong expected onu reason ${expected_onu_reason}, must be lower than 'omci-flows-pushed'!
TorstenThieme440b7c02020-12-18 15:42:57 +0000257 FOR ${I} IN RANGE 0 ${num_olts}
258 #get olt serial number
259 ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn]
260 #validate olt states
261 ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
262 Enable Device ${olt_device_id}
263 END
264 Current State Test All Onus ${expected_onu_reason}
265 Run Keyword If ${usekill2restart} Kill And Check Onu Adaptor ${namespace}
266 ... ELSE Restart And Check Onu Adaptor ${namespace}
TorstenThiemec3c23232021-01-13 13:06:31 +0000267 Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT
TorstenThiemea36068c2021-02-19 09:57:32 +0000268 ... ELSE IF "${workflow}"=="TT" Perform Sanity Test TT
TorstenThiemec3c23232021-01-13 13:06:31 +0000269 ... ELSE Perform Sanity Test
TorstenThieme440b7c02020-12-18 15:42:57 +0000270
271Do Reconcile For Disabled Onu Device
272 [Documentation] This keyword reconciles ONU device for a disabled onu device and
273 ... check the state afterwards.
274 ... Following steps will be executed:
275 ... - enable OLT device
TorstenThiemec3c23232021-01-13 13:06:31 +0000276 ... - perform sanity test include add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000277 ... - disable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000278 ... - wait for corresponding openonu reason
TorstenThieme440b7c02020-12-18 15:42:57 +0000279 ... - check UNI-ports disabled in ONOS
280 ... - restart openonu adaptor
281 ... - check openonu adaptor is ready again
TorstenThiemec3c23232021-01-13 13:06:31 +0000282 ... - check device reason is still before restart
TorstenThieme440b7c02020-12-18 15:42:57 +0000283 ... - enable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000284 ... - perform sanity test suppress add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000285 FOR ${I} IN RANGE 0 ${num_olts}
286 #get olt serial number
287 ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn]
288 #validate olt states
289 ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
290 Enable Device ${olt_device_id}
291 END
TorstenThiemec3c23232021-01-13 13:06:31 +0000292 Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT
TorstenThiemea36068c2021-02-19 09:57:32 +0000293 ... ELSE IF "${workflow}"=="TT" Perform Sanity Test TT
TorstenThiemec3c23232021-01-13 13:06:31 +0000294 ... ELSE Perform Sanity Test
TorstenThieme440b7c02020-12-18 15:42:57 +0000295 Disable Onu Device
TorstenThieme3871cf72021-01-21 14:11:57 +0000296 ${alternativeonustates}= Create List omci-flows-deleted
297 Run Keyword If "${workflow}"=="DT" Current State Test All Onus omci-admin-lock
298 ... ELSE IF "${workflow}"=="TT" Current State Test All Onus omci-admin-lock
299 ... ELSE Current State Test All Onus omci-admin-lock alternativeonustate=${alternativeonustates}
TorstenThieme440b7c02020-12-18 15:42:57 +0000300 Run Keyword If ${usekill2restart} Kill And Check Onu Adaptor ${namespace}
301 ... ELSE Restart And Check Onu Adaptor ${namespace}
TorstenThieme3871cf72021-01-21 14:11:57 +0000302 Run Keyword If "${workflow}"=="DT" Current State Test All Onus omci-admin-lock
303 ... ELSE IF "${workflow}"=="TT" Current State Test All Onus omci-admin-lock
304 ... ELSE Current State Test All Onus omci-admin-lock alternativeonustate=${alternativeonustates}
TorstenThieme440b7c02020-12-18 15:42:57 +0000305 Wait for all ONU Ports in ONOS Disabled ${onos_ssh_connection}
306 Enable Onu Device
TorstenThieme70bc5262021-01-19 12:12:55 +0000307 Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT ${suppressaddsubscriber}
TorstenThiemea36068c2021-02-19 09:57:32 +0000308 ... ELSE IF "${workflow}"=="TT" Perform Sanity Test TT ${suppressaddsubscriber}
TorstenThieme70bc5262021-01-19 12:12:55 +0000309 ... ELSE Perform Sanity Test ${suppressaddsubscriber}
TorstenThieme440b7c02020-12-18 15:42:57 +0000310
311Do Reconcile In Omci-Flows-Pushed
312 [Documentation] This keyword reconciles ONU device in omci-flows-pushed and check the state afterwards.
313 ... Reconcile test during omci-flows-pushed in AT&T-workflow:
314 ... - create and enable one BBSIM-ONU (no MIB-template should be available in KV-store)
TorstenThiemec3c23232021-01-13 13:06:31 +0000315 ... - perform sanity test include add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000316 ... - kill the open-onu-adapter-go
TorstenThiemec3c23232021-01-13 13:06:31 +0000317 ... - wait for open-onu-adapter-go to restart
318 ... - perform sanity test suppress add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000319 ... - disable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000320 ... - wait for corresponding device reason
321 ... - check UNI-ports disabled in ONOS
TorstenThieme440b7c02020-12-18 15:42:57 +0000322 ... - enable onu device
TorstenThiemec3c23232021-01-13 13:06:31 +0000323 ... - perform sanity test supress add subscriber
TorstenThieme440b7c02020-12-18 15:42:57 +0000324 FOR ${I} IN RANGE 0 ${num_olts}
325 #get olt serial number
326 ${olt_serial_number}= Set Variable ${list_olts}[${I}][sn]
327 #validate olt states
328 ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
329 Enable Device ${olt_device_id}
330 END
TorstenThiemec3c23232021-01-13 13:06:31 +0000331 Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT
TorstenThiemea36068c2021-02-19 09:57:32 +0000332 ... ELSE IF "${workflow}"=="TT" Perform Sanity Test TT
TorstenThiemec3c23232021-01-13 13:06:31 +0000333 ... ELSE Perform Sanity Test
TorstenThieme440b7c02020-12-18 15:42:57 +0000334 Run Keyword If ${usekill2restart} Kill And Check Onu Adaptor ${namespace}
335 ... ELSE Restart And Check Onu Adaptor ${namespace}
TorstenThieme70bc5262021-01-19 12:12:55 +0000336 Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT ${suppressaddsubscriber}
TorstenThiemea36068c2021-02-19 09:57:32 +0000337 ... ELSE IF "${workflow}"=="TT" Perform Sanity Test TT ${suppressaddsubscriber}
TorstenThieme70bc5262021-01-19 12:12:55 +0000338 ... ELSE Perform Sanity Test ${suppressaddsubscriber}
TorstenThieme440b7c02020-12-18 15:42:57 +0000339 Disable Onu Device
TorstenThieme3871cf72021-01-21 14:11:57 +0000340 ${alternativeonustates}= Create List omci-flows-deleted
341 Run Keyword If "${workflow}"=="DT" Current State Test All Onus omci-admin-lock
342 ... ELSE IF "${workflow}"=="TT" Current State Test All Onus omci-admin-lock
343 ... ELSE Current State Test All Onus omci-admin-lock alternativeonustate=${alternativeonustates}
TorstenThieme440b7c02020-12-18 15:42:57 +0000344 Wait for all ONU Ports in ONOS Disabled ${onos_ssh_connection}
TorstenThieme440b7c02020-12-18 15:42:57 +0000345 Enable Onu Device
TorstenThieme70bc5262021-01-19 12:12:55 +0000346 Run Keyword If "${workflow}"=="DT" Perform Sanity Test DT ${suppressaddsubscriber}
TorstenThiemea36068c2021-02-19 09:57:32 +0000347 ... ELSE IF "${workflow}"=="TT" Perform Sanity Test TT ${suppressaddsubscriber}
TorstenThieme70bc5262021-01-19 12:12:55 +0000348 ... ELSE Perform Sanity Test ${suppressaddsubscriber}