blob: b4bd8d2272e5f93192a05e5e8c2c489ca6669593 [file] [log] [blame]
Kailash6f5acb62019-08-28 14:38:45 -07001# Copyright 2017-present Open Networking Foundation
2#
3# Licensed under the Apache License, Version 2.0 (the "License");
4# you may not use this file except in compliance with the License.
5# You may obtain a copy of the License at
6#
7# http://www.apache.org/licenses/LICENSE-2.0
8#
9# Unless required by applicable law or agreed to in writing, software
10# distributed under the License is distributed on an "AS IS" BASIS,
11# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
12# See the License for the specific language governing permissions and
13# limitations under the License.
Kailash6f5acb62019-08-28 14:38:45 -070014# voltctl common functions
15
16*** Settings ***
17Documentation Library for various utilities
18Library SSHLibrary
Kailash6f5acb62019-08-28 14:38:45 -070019Library String
20Library DateTime
21Library Process
22Library Collections
23Library RequestsLibrary
24Library OperatingSystem
Matteo Scandolo142e6272020-04-29 17:36:59 -070025Resource ./utils.robot
Matteo Scandoloeb26a842020-05-08 10:06:24 -070026Resource ./flows.robot
Kailash6f5acb62019-08-28 14:38:45 -070027
28*** Keywords ***
Gilles Depatieb5682f82019-10-31 10:39:45 -040029Test Empty Device List
Zack Williamsa8fe75a2020-01-10 14:25:27 -070030 [Documentation] Verify that there are no devices in the system
Matteo Scandolo5899be12020-11-11 15:38:07 -080031 ${rc} ${output}= Run and Return Rc and Output voltctl -c ${VOLTCTL_CONFIG} device list -o json
Gilles Depatieb5682f82019-10-31 10:39:45 -040032 Should Be Equal As Integers ${rc} 0
33 ${jsondata}= To Json ${output}
34 Log ${jsondata}
35 ${length}= Get Length ${jsondata}
David Bainbridgef81cd642019-11-20 00:14:47 +000036 Should Be Equal As Integers ${length} 0
Gilles Depatieb5682f82019-10-31 10:39:45 -040037
Kailash6f5acb62019-08-28 14:38:45 -070038Create Device
Matteo Scandolo142e6272020-04-29 17:36:59 -070039 [Arguments] ${ip} ${port} ${type}=openolt
You Wang2b550642019-10-07 14:39:48 -070040 [Documentation] Creates a device in VOLTHA
Kailash6f5acb62019-08-28 14:38:45 -070041 #create/preprovision device
Gilles Depatie675a2062019-10-22 12:44:42 -040042 ${rc} ${device_id}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -080043 ... voltctl -c ${VOLTCTL_CONFIG} device create -t ${type} -H ${ip}:${port}
44 Log ${device_id}
Matteo Scandolo741d4fd2021-09-23 17:08:34 -070045 Should Be Equal As Integers ${rc} 0 Failed to Create Device beause of ${device_id}
Kailash6f5acb62019-08-28 14:38:45 -070046 [Return] ${device_id}
47
48Enable Device
49 [Arguments] ${device_id}
Zack Williamsec53a1b2019-09-16 15:50:52 -070050 [Documentation] Enables a device in VOLTHA
Zack Williamsa8fe75a2020-01-10 14:25:27 -070051 ${rc} ${output}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -080052 ... voltctl -c ${VOLTCTL_CONFIG} device enable ${device_id}
Matteo Scandolo741d4fd2021-09-23 17:08:34 -070053 Should Be Equal As Integers ${rc} 0 Failed to Enable Device beause of ${output}
Kailash6f5acb62019-08-28 14:38:45 -070054
Suchitra Vemuri6db89412019-11-14 14:52:54 -080055Disable Device
56 [Arguments] ${device_id}
Hardik Windlassaaea3402020-03-10 19:45:45 +053057 [Documentation] Disables a device in VOLTHA
Zack Williamsa8fe75a2020-01-10 14:25:27 -070058 ${rc} ${output}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -080059 ... voltctl -c ${VOLTCTL_CONFIG} device disable ${device_id}
Matteo Scandolo741d4fd2021-09-23 17:08:34 -070060 Should Be Equal As Integers ${rc} 0 Failed to Disable Device beause of ${output}
Suchitra Vemuri6db89412019-11-14 14:52:54 -080061
Hardik Windlassaaea3402020-03-10 19:45:45 +053062Delete Device
63 [Arguments] ${device_id}
64 [Documentation] Deletes a device in VOLTHA
65 ${rc} ${output}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -080066 ... voltctl -c ${VOLTCTL_CONFIG} device delete ${device_id}
Matteo Scandolo741d4fd2021-09-23 17:08:34 -070067 Should Be Equal As Integers ${rc} 0 Failed to Delete Device beause of ${output}
Hardik Windlassaaea3402020-03-10 19:45:45 +053068
Hemadf003682020-04-28 21:22:22 +053069Reboot Device
70 [Arguments] ${device_id}
71 [Documentation] Reboot the OLT using voltctl command
72 ${rc} ${output}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -080073 ... voltctl -c ${VOLTCTL_CONFIG} device reboot ${device_id}
Matteo Scandolo741d4fd2021-09-23 17:08:34 -070074 Should Be Equal As Integers ${rc} 0 Failed to Reboot Device beause of ${output}
Hemadf003682020-04-28 21:22:22 +053075
David Bainbridgef81cd642019-11-20 00:14:47 +000076Disable Devices In Voltha
77 [Documentation] Disables all the known devices in voltha
78 [Arguments] ${filter}
79 ${arg}= Set Variable ${EMPTY}
80 ${arg}= Run Keyword If len('${filter}'.strip()) != 0 Set Variable --filter ${filter}
Zack Williamsa8fe75a2020-01-10 14:25:27 -070081 ${rc} ${devices}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -080082 ... voltctl -c ${VOLTCTL_CONFIG} device list -m 8MB ${arg} --orderby Root -q | xargs echo -n
David Bainbridgef81cd642019-11-20 00:14:47 +000083 Should Be Equal As Integers ${rc} 0
Zack Williamsa8fe75a2020-01-10 14:25:27 -070084 ${rc} ${output}= Run Keyword If len('${devices}') != 0 Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -080085 ... voltctl -c ${VOLTCTL_CONFIG} device disable ${devices}
Matteo Scandolo741d4fd2021-09-23 17:08:34 -070086 Run Keyword If len('${devices}') != 0
87 ... Should Be Equal As Integers ${rc} 0 Failed to Disable Devices beause of ${output}
David Bainbridgef81cd642019-11-20 00:14:47 +000088
89Test Devices Disabled In Voltha
90 [Documentation] Tests to verify that all devices in VOLTHA are disabled
91 [Arguments] ${filter}
Zack Williamsa8fe75a2020-01-10 14:25:27 -070092 ${rc} ${count}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -080093 ... voltctl -c ${VOLTCTL_CONFIG} device list -m 8MB --filter '${filter},AdminState!=DISABLED' -q | wc -l
David Bainbridgef81cd642019-11-20 00:14:47 +000094 Should Be Equal As Integers ${rc} 0
95 Should Be Equal As Integers ${count} 0
96
97Delete Devices In Voltha
98 [Documentation] Disables all the known devices in voltha
99 [Arguments] ${filter}
100 ${arg}= Set Variable ${EMPTY}
101 ${arg}= Run Keyword If len('${filter}'.strip()) != 0 Set Variable --filter ${filter}
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700102 ${rc} ${devices}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800103 ... voltctl -c ${VOLTCTL_CONFIG} device list ${arg} -m 8MB --orderby Root -q | xargs echo -n
David Bainbridgef81cd642019-11-20 00:14:47 +0000104 Should Be Equal As Integers ${rc} 0
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700105 ${rc} ${output}= Run Keyword If len('${devices}') != 0 Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800106 ... voltctl -c ${VOLTCTL_CONFIG} device delete ${devices}
David Bainbridgef81cd642019-11-20 00:14:47 +0000107 Run Keyword If len('${devices}') != 0 Should Be Equal As Integers ${rc} 0
108
Suchitra Vemuri00d147d2019-09-13 13:07:32 -0700109Get Device Flows from Voltha
110 [Arguments] ${device_id}
Zack Williamsec53a1b2019-09-16 15:50:52 -0700111 [Documentation] Gets device flows from VOLTHA
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700112 ${rc} ${output}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800113 ... voltctl -c ${VOLTCTL_CONFIG} device flows ${device_id} -m 8MB
Suchitra Vemuri00d147d2019-09-13 13:07:32 -0700114 Should Be Equal As Integers ${rc} 0
115 [Return] ${output}
116
117Get Logical Device Output from Voltha
118 [Arguments] ${device_id}
Zack Williamsec53a1b2019-09-16 15:50:52 -0700119 [Documentation] Gets logicaldevice flows and ports from VOLTHA
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700120 ${rc1} ${flows}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800121 ... voltctl -c ${VOLTCTL_CONFIG} logicaldevice flows ${device_id}
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700122 ${rc2} ${ports}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800123 ... voltctl -c ${VOLTCTL_CONFIG} logicaldevice port list ${device_id}
Suchitra Vemuri00d147d2019-09-13 13:07:32 -0700124 Log ${flows}
125 Log ${ports}
126 Should Be Equal As Integers ${rc1} 0
127 Should Be Equal As Integers ${rc2} 0
128
129Get Device Output from Voltha
130 [Arguments] ${device_id}
Zack Williamsec53a1b2019-09-16 15:50:52 -0700131 [Documentation] Gets device flows and ports from VOLTHA
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700132 ${rc1} ${flows}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800133 ... voltctl -c ${VOLTCTL_CONFIG} device flows ${device_id} -m 8MB
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700134 ${rc2} ${ports}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800135 ... voltctl -c ${VOLTCTL_CONFIG} device port list ${device_id} -m 8MB
Suchitra Vemuri00d147d2019-09-13 13:07:32 -0700136 Log ${flows}
137 Log ${ports}
138 Should Be Equal As Integers ${rc1} 0
139 Should Be Equal As Integers ${rc2} 0
140
Suchitra Vemuri1a970a62019-11-26 12:52:16 -0800141Get Device List from Voltha
142 [Documentation] Gets Device List Output from Voltha
Matteo Scandolo5899be12020-11-11 15:38:07 -0800143 ${rc1} ${devices}= Run and Return Rc and Output voltctl -c ${VOLTCTL_CONFIG} device list -m 8MB
Suchitra Vemuri1a970a62019-11-26 12:52:16 -0800144 Log ${devices}
145 Should Be Equal As Integers ${rc1} 0
146
Matteo Scandolo616daab2020-05-13 11:49:24 -0700147Get Device List from Voltha by type
148 [Documentation] Gets Device List Output from Voltha applying filtering by device type
149 [Arguments] ${type}
150 ${rc1} ${devices}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800151 ... voltctl -c ${VOLTCTL_CONFIG} device list -m 8MB -f Type=${type} -o json
Matteo Scandolo616daab2020-05-13 11:49:24 -0700152 Log ${devices}
153 Should Be Equal As Integers ${rc1} 0
154 Return From Keyword ${devices}
155
Matteo Scandolo142e6272020-04-29 17:36:59 -0700156Get Logical Device List from Voltha
157 [Documentation] Gets Logical Device List Output from Voltha (in json format)
Andrea Campanella80655eb2020-07-10 15:49:22 +0200158 ${rc1} ${devices}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800159 ... voltctl -c ${VOLTCTL_CONFIG} logicaldevice list -m 8MB -o json
Matteo Scandolo142e6272020-04-29 17:36:59 -0700160 Log ${devices}
161 Should Be Equal As Integers ${rc1} 0
162 Return From Keyword ${devices}
163
Kailash6f5acb62019-08-28 14:38:45 -0700164Validate Device
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700165 [Documentation]
ubuntu6b6e7d42020-03-02 12:35:42 -0800166 ... Parses the output of "voltctl device list" and inspects a device ${id}, specified as either
167 ... the serial number or device ID. Arguments are matched for device states of: "admin_state",
168 ... "oper_status", and "connect_status"
Hardik Windlass8b446492021-06-10 06:25:23 +0000169 ... Note: Set "by_dev_id" to True if Device Id is passed for validation
170 ... otherwise look up will be based on Device Serial Number
ubuntu6b6e7d42020-03-02 12:35:42 -0800171 [Arguments] ${admin_state} ${oper_status} ${connect_status}
Hardik Windlass8b446492021-06-10 06:25:23 +0000172 ... ${id} ${onu_reason}=${EMPTY} ${onu}=False ${by_dev_id}=False
173 ${rc} ${output}= Run Keyword If ${by_dev_id} Run and Return Rc and Output
174 ... voltctl -c ${VOLTCTL_CONFIG} device list -m 8MB -f Id=${id} -o json
175 ... ELSE Run and Return Rc and Output
176 ... voltctl -c ${VOLTCTL_CONFIG} device list -m 8MB -f SerialNumber=${id} -o json
Gilles Depatieb5682f82019-10-31 10:39:45 -0400177 Should Be Equal As Integers ${rc} 0
Kailash6f5acb62019-08-28 14:38:45 -0700178 ${jsondata}= To Json ${output}
Matteo Scandolobfb74382021-05-10 15:45:16 -0700179 Log ${output}
Kailash6f5acb62019-08-28 14:38:45 -0700180 ${length}= Get Length ${jsondata}
ubuntu6b6e7d42020-03-02 12:35:42 -0800181 ${matched}= Set Variable False
Zack Williamsec53a1b2019-09-16 15:50:52 -0700182 FOR ${INDEX} IN RANGE 0 ${length}
183 ${value}= Get From List ${jsondata} ${INDEX}
Scott Baker780b65f2020-05-22 14:03:15 -0700184 ${jsonCamelCaseFieldnames}= Run Keyword And Return Status
185 ... Dictionary Should Contain Key ${value} adminState
186 ${astate}= Run Keyword If ${jsonCamelCaseFieldNames}
187 ... Get From Dictionary ${value} adminState
188 ... ELSE
189 ... Get From Dictionary ${value} adminstate
190 ${opstatus}= Run Keyword If ${jsonCamelCaseFieldNames}
191 ... Get From Dictionary ${value} operStatus
192 ... ELSE
193 ... Get From Dictionary ${value} operstatus
194 ${cstatus}= Run Keyword If ${jsonCamelCaseFieldNames}
195 ... Get From Dictionary ${value} connectStatus
196 ... ELSE
197 ... Get From Dictionary ${value} connectstatus
198 ${sn}= Run Keyword If ${jsonCamelCaseFieldNames}
199 ... Get From Dictionary ${value} serialNumber
200 ... ELSE
201 ... Get From Dictionary ${value} serialnumber
Gilles Depatieb5682f82019-10-31 10:39:45 -0400202 ${devId}= Get From Dictionary ${value} id
Zack Williamsec53a1b2019-09-16 15:50:52 -0700203 ${mib_state}= Get From Dictionary ${value} reason
ubuntu6b6e7d42020-03-02 12:35:42 -0800204 ${matched}= Set Variable If '${sn}' == '${id}' or '${devId}' == '${id}' True False
Andy Bavierb63f6d22020-03-12 15:34:37 -0700205 Exit For Loop If ${matched}
Zack Williamsec53a1b2019-09-16 15:50:52 -0700206 END
Andy Bavierb63f6d22020-03-12 15:34:37 -0700207 Should Be True ${matched} No match found for ${id} to validate device
Matteo Scandolo5e10b282019-11-25 10:54:32 -0700208 Log ${value}
ubuntu6b6e7d42020-03-02 12:35:42 -0800209 Should Be Equal '${astate}' '${admin_state}' Device ${sn} admin_state != ${admin_state}
Gilles Depatie675a2062019-10-22 12:44:42 -0400210 ... values=False
ubuntu6b6e7d42020-03-02 12:35:42 -0800211 Should Be Equal '${opstatus}' '${oper_status}' Device ${sn} oper_status != ${oper_status}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400212 ... values=False
ubuntu6b6e7d42020-03-02 12:35:42 -0800213 Should Be Equal '${cstatus}' '${connect_status}' Device ${sn} conn_status != ${connect_status}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400214 ... values=False
Matteo Scandolo74bd5c32020-12-08 09:52:19 -0800215 Run Keyword If '${onu}' == 'True' Should Contain '${onu_reason}' '${mib_state}'
ubuntu6b6e7d42020-03-02 12:35:42 -0800216 ... Device ${sn} mib_state incorrect (${mib_state}) values=False
Gilles Depatieb5682f82019-10-31 10:39:45 -0400217
218Validate OLT Device
Hardik Windlass8b446492021-06-10 06:25:23 +0000219 [Arguments] ${admin_state} ${oper_status} ${connect_status} ${id} ${by_dev_id}=False
ubuntu6b6e7d42020-03-02 12:35:42 -0800220 [Documentation] Parses the output of "voltctl device list" and inspects device ${id}, specified
221 ... as either its serial numbner or device ID. Match on OLT Serial number or Device Id and inspect states
Hardik Windlass8b446492021-06-10 06:25:23 +0000222 ... Note: Set "by_dev_id" to True if Device Id is passed for validation
223 ... otherwise look up will be based on Device Serial Number
224 Validate Device ${admin_state} ${oper_status} ${connect_status} ${id} by_dev_id=${by_dev_id}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400225
Suchitra Vemuria6879aa2020-11-03 11:03:11 -0800226Validate OLT Devices
227 [Arguments] ${admin_state} ${oper_status} ${connect_status} ${ids}=${EMPTY}
228 [Documentation] Parses the output of "voltctl device list" and inspects device ${id}, specified
229 ... as either its serial numbner or device ID. Match on OLT Serial number or Device Id and inspect states
230 FOR ${I} IN RANGE 0 ${olt_count}
231 ${olt_serial_number}= Get From Dictionary ${olt_ids}[${I}] sn
232 ${olt_device_id}= Get OLTDeviceID From OLT List ${olt_serial_number}
Hardik Windlass8b446492021-06-10 06:25:23 +0000233 Validate Device ${admin_state} ${oper_status} ${connect_status} ${olt_device_id} by_dev_id=True
Suchitra Vemuria6879aa2020-11-03 11:03:11 -0800234 END
235
Gilles Depatieb5682f82019-10-31 10:39:45 -0400236Validate ONU Devices
237 [Arguments] ${admin_state} ${oper_status} ${connect_status} ${List_ONU_Serial}
Andy Bavierf1f26ed2020-03-18 10:59:07 -0700238 ... ${onu_reason}=omci-flows-pushed
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700239 [Documentation] Parses the output of "voltctl device list" and inspects device ${List_ONU_Serial}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400240 ... Iteratively match on each Serial number contained in ${List_ONU_Serial} and inspect
241 ... states including MIB state
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700242 FOR ${serial_number} IN @{List_ONU_Serial}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400243 Validate Device ${admin_state} ${oper_status} ${connect_status} ${serial_number}
Andy Bavierf1f26ed2020-03-18 10:59:07 -0700244 ... onu_reason=${onu_reason} onu=True
Debasish28130d02020-03-16 11:05:26 +0000245 END
246
Gilles Depatieb5682f82019-10-31 10:39:45 -0400247Validate Device Port Types
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700248 [Documentation]
David K. Bainbridgebd5ebd22020-02-04 10:01:18 -0800249 ... Parses the output of voltctl device port list <device_id> and matches the port types listed
Andy Bavier90eb1a12020-03-26 11:54:35 -0700250 [Arguments] ${device_id} ${pon_type} ${ethernet_type} ${all_active}=True
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700251 ${rc} ${output}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800252 ... voltctl -c ${VOLTCTL_CONFIG} device port list ${device_id} -m 8MB -o json
Gilles Depatieb5682f82019-10-31 10:39:45 -0400253 Should Be Equal As Integers ${rc} 0
254 ${jsondata}= To Json ${output}
255 Log ${jsondata}
256 ${length}= Get Length ${jsondata}
257 FOR ${INDEX} IN RANGE 0 ${length}
258 ${value}= Get From List ${jsondata} ${INDEX}
Scott Baker780b65f2020-05-22 14:03:15 -0700259 ${jsonCamelCaseFieldnames}= Run Keyword And Return Status
260 ... Dictionary Should Contain Key ${value} adminState
261 ${astate}= Run Keyword If ${jsonCamelCaseFieldNames}
Hardik Windlass2b37e712020-06-12 02:13:17 +0530262 ... Get From Dictionary ${value} adminState
Scott Baker780b65f2020-05-22 14:03:15 -0700263 ... ELSE
Hardik Windlass2b37e712020-06-12 02:13:17 +0530264 ... Get From Dictionary ${value} adminstate
Scott Baker780b65f2020-05-22 14:03:15 -0700265 ${opstatus}= Run Keyword If ${jsonCamelCaseFieldNames}
266 ... Get From Dictionary ${value} operStatus
267 ... ELSE
Hardik Windlass2b37e712020-06-12 02:13:17 +0530268 ... Get From Dictionary ${value} operstatus
Gilles Depatieb5682f82019-10-31 10:39:45 -0400269 ${type}= Get From Dictionary ${value} type
Hemaf64d34c2020-03-25 00:40:17 +0530270 Should Be Equal '${astate}' 'ENABLED' Device ${device_id} port admin_state != ENABLED values=False
Andy Bavier90eb1a12020-03-26 11:54:35 -0700271 Run Keyword If ${all_active} Should Be Equal '${opstatus}' 'ACTIVE'
272 ... Device ${device_id} port oper_status != ACTIVE values=False
Gilles Depatieb5682f82019-10-31 10:39:45 -0400273 Should Be True '${type}' == '${pon_type}' or '${type}' == '${ethernet_type}'
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700274 ... Device ${device_id} port type is neither ${pon_type} or ${ethernet_type}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400275 END
276
277Validate OLT Port Types
David K. Bainbridgebd5ebd22020-02-04 10:01:18 -0800278 [Documentation] Parses the output of voltctl device port list ${olt_device_id} and matches the port types listed
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700279 [Arguments] ${pon_type} ${ethernet_type}
280 Validate Device Port Types ${olt_device_id} ${pon_type} ${ethernet_type}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400281
282Validate ONU Port Types
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700283 [Arguments] ${List_ONU_Serial} ${pon_type} ${ethernet_type}
David K. Bainbridgebd5ebd22020-02-04 10:01:18 -0800284 [Documentation] Parses the output of voltctl device port list for each ONU SN listed in ${List_ONU_Serial}
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700285 ... and matches the port types listed
Gilles Depatieb5682f82019-10-31 10:39:45 -0400286 FOR ${serial_number} IN @{List_ONU_Serial}
287 ${onu_dev_id}= Get Device ID From SN ${serial_number}
Andy Bavier90eb1a12020-03-26 11:54:35 -0700288 # Only first UNI port is ACTIVE; the rest are in DISCOVERED operstatus
289 Validate Device Port Types ${onu_dev_id} ${pon_type} ${ethernet_type} all_active=False
Gilles Depatieb5682f82019-10-31 10:39:45 -0400290 END
291
292Validate Device Flows
Hardik Windlassa3d04b92020-02-17 15:06:05 +0000293 [Arguments] ${device_id} ${flow_count}=${EMPTY}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400294 [Documentation] Parses the output of voltctl device flows <device_id> and expects flow count > 0
Andrea Campanella80655eb2020-07-10 15:49:22 +0200295 ${rc} ${output}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800296 ... voltctl -c ${VOLTCTL_CONFIG} device flows ${device_id} -m 8MB -o json
Gilles Depatieb5682f82019-10-31 10:39:45 -0400297 Should Be Equal As Integers ${rc} 0
298 ${jsondata}= To Json ${output}
299 Log ${jsondata}
300 ${length}= Get Length ${jsondata}
301 Log 'Number of flows = ' ${length}
Hardik Windlassa3d04b92020-02-17 15:06:05 +0000302 Run Keyword If '${flow_count}' == '${EMPTY}' Should Be True ${length} > 0
Gilles Depatieb5682f82019-10-31 10:39:45 -0400303 ... Number of flows for ${device_id} was 0
Hardik Windlassa3d04b92020-02-17 15:06:05 +0000304 ... ELSE Should Be True ${length} == ${flow_count}
305 ... Number of flows for ${device_id} was not ${flow_count}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400306
307Validate OLT Flows
Suchitra Vemuria6879aa2020-11-03 11:03:11 -0800308 [Arguments] ${flow_count}=${EMPTY} ${olt_device_id}=${EMPTY}
Hardik Windlassa3d04b92020-02-17 15:06:05 +0000309 [Documentation] Parses the output of voltctl device flows ${olt_device_id}
310 ... and expects flow count == ${flow_count}
311 Validate Device Flows ${olt_device_id} ${flow_count}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400312
313Validate ONU Flows
Hardik Windlassa3d04b92020-02-17 15:06:05 +0000314 [Arguments] ${List_ONU_Serial} ${flow_count}=${EMPTY}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400315 [Documentation] Parses the output of voltctl device flows for each ONU SN listed in ${List_ONU_Serial}
Hardik Windlassa3d04b92020-02-17 15:06:05 +0000316 ... and expects flow count == ${flow_count}
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700317 FOR ${serial_number} IN @{List_ONU_Serial}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400318 ${onu_dev_id}= Get Device ID From SN ${serial_number}
Hardik Windlassa3d04b92020-02-17 15:06:05 +0000319 Validate Device Flows ${onu_dev_id} ${flow_count}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400320 END
321
TorstenThieme401af432020-06-11 15:53:53 +0000322Validate ONU Devices With Duration
323 [Documentation]
324 ... Parses the output of "voltctl device list" and inspects all devices ${List_ONU_Serial},
325 ... Iteratively match on each Serial number contained in ${List_ONU_Serial} and inspect
326 ... states including MIB state.
327 [Arguments] ${admin_state} ${oper_status} ${connect_status} ${onu_reason}
328 ... ${List_ONU_Serial} ${startTime} ${print2console}=False ${output_file}=${EMPTY}
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000329 ... ${alternate_reason}=${EMPTY}
TorstenThiemef78a9d82021-03-05 13:42:09 +0000330 ${cmd}= Catenate voltctl -c ${VOLTCTL_CONFIG} device list -m 8MB -f Type=brcm_openomci_onu
Matteo Scandolo6f24ea92021-04-29 11:55:50 -0700331 ... --format "{{.SerialNumber}}\t{{.AdminState}}\t{{.OperStatus}}\t{{.ConnectStatus}}\t{{.Reason}}" | grep -v SERIALNUMBER
TorstenThiemef78a9d82021-03-05 13:42:09 +0000332 ${rc} ${output}= Run and Return Rc and Output ${cmd}
Matteo Scandolo741d4fd2021-09-23 17:08:34 -0700333 Should Be Equal As Integers ${rc} 0 Failed Validate ONU Devices because of ${output}
334 Log ${output}
TorstenThieme401af432020-06-11 15:53:53 +0000335 ${timeCurrent} = Get Current Date
336 ${timeTotalMs} = Subtract Date From Date ${timeCurrent} ${startTime} result_format=number
TorstenThiemef78a9d82021-03-05 13:42:09 +0000337 @{Results}= Split String ${output} \n
338 FOR ${Line} IN @{Results}
TorstenThieme401af432020-06-11 15:53:53 +0000339 ${matched}= Set Variable False
TorstenThiemef78a9d82021-03-05 13:42:09 +0000340 @{words}= Split String ${Line} \t
341 ${sn}= Set Variable ${words[0]}
342 ${astate}= Set Variable ${words[1]}
343 ${opstatus}= Set Variable ${words[2]}
344 ${cstatus}= Set Variable ${words[3]}
345 ${mib_state}= Set Variable ${words[4]}
TorstenThieme401af432020-06-11 15:53:53 +0000346 ${onu_id}= Get Index From List ${List_ONU_Serial} ${sn}
347 ${matched}= Set Variable If -1 != ${onu_id} True False
348 ${matched}= Set Variable If '${astate}' == '${admin_state}' ${matched} False
349 ${matched}= Set Variable If '${opstatus}' == '${oper_status}' ${matched} False
350 ${matched}= Set Variable If '${cstatus}' == '${connect_status}' ${matched} False
TorstenThiemec3c23232021-01-13 13:06:31 +0000351 ${len}= Get Length ${alternate_reason}
TorstenThieme105c5982021-01-21 09:50:27 +0000352 ${matches}= Run Keyword If ${len} >= 1 Get Match Count ${alternate_reason} ${mib_state}
353 ... ELSE Set Variable 0
TorstenThiemec3c23232021-01-13 13:06:31 +0000354 ${matched}= Set Variable If '${mib_state}' == '${onu_reason}' or ${matches} >= 1
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000355 ... ${matched} False
TorstenThieme401af432020-06-11 15:53:53 +0000356 Run Keyword If ${matched} and ${print2console} Log
357 ... \r\nONU ${sn} reached the state ${onu_reason} after ${timeTotalMs} sec. console=yes
358 Run Keyword If ${matched} and ('${output_file}'!='${EMPTY}') Append To File ${output_file}
359 ... \r\nONU ${sn} reached the state ${onu_reason} after ${timeTotalMs} sec.
360 Run Keyword If ${matched} Remove Values From List ${List_ONU_Serial} ${sn}
361 END
362 Should Be Empty ${List_ONU_Serial} List ${List_ONU_Serial} not empty
363
TorstenThieme9949b172020-06-16 10:00:15 +0000364Validate ONU Devices MIB State With Duration
365 [Documentation]
366 ... Parses the output of "voltctl device list" and inspects all devices ${List_ONU_Serial},
367 ... Iteratively match on each Serial number contained in ${List_ONU_Serial} and inspect MIB state.
368 [Arguments] ${onu_reason}
369 ... ${List_ONU_Serial} ${startTime} ${print2console}=False ${output_file}=${EMPTY}
370 ${type} = Set Variable brcm_openomci_onu
Andrea Campanella80655eb2020-07-10 15:49:22 +0200371 ${voltctl_commad} = Catenate SEPARATOR=
372 ... voltctl device list -m 8MB -f Type=${type} -f Reason=${onu_reason} --format '{{.SerialNumber}}'
373 ${rc} ${output}= Run and Return Rc and Output ${voltctl_commad}
TorstenThieme9949b172020-06-16 10:00:15 +0000374 Should Be Equal As Integers ${rc} 0
375 ${timeCurrent} = Get Current Date
376 ${timeTotalMs} = Subtract Date From Date ${timeCurrent} ${startTime} result_format=number
377 @{outputdata} = Split String ${output}
378 ${outputlength} = Get Length ${outputdata}
379 ${onulength} = Get Length ${List_ONU_Serial}
380 ${Matches} = Run Keyword If ${outputlength}<=${onulength}
381 ... Compare Lists ${outputdata} ${List_ONU_Serial}
382 ... ELSE Compare Lists ${List_ONU_Serial} ${outputdata}
383 ${length} = Get Length ${Matches}
384 FOR ${INDEX} IN RANGE 0 ${length}
385 ${sn}= Get From List ${Matches} ${INDEX}
386 Run Keyword If ${print2console} Log
387 ... \r\nONU ${sn} reached the state ${onu_reason} after ${timeTotalMs} sec. console=yes
388 Run Keyword If ('${output_file}'!='${EMPTY}') Append To File ${output_file}
389 ... \r\nONU ${sn} reached the state ${onu_reason} after ${timeTotalMs} sec.
390 Remove Values From List ${List_ONU_Serial} ${sn}
391 END
392 Should Be Empty ${List_ONU_Serial} List ${List_ONU_Serial} not empty
393
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000394Validate ONU Device By Device Id
395 [Documentation]
396 ... Parses the output of "voltctl device list" filtered by device id and inspects states including reason.
397 [Arguments] ${admin_state} ${oper_status} ${connect_status} ${onu_reason} ${onu_id}
Matteo Scandolo5899be12020-11-11 15:38:07 -0800398 ${cmd} Catenate voltctl -c ${VOLTCTL_CONFIG} device list --filter=Id=${onu_id} -m 8MB -o json
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000399 ${rc} ${output}= Run and Return Rc and Output ${cmd}
400 Should Be Equal As Integers ${rc} 0
401 ${jsondata}= To Json ${output}
402 ${length}= Get Length ${jsondata}
403 Should Be Equal As Integers ${length} 1 No match found for ${onu_id} to validate device
404 ${value}= Get From List ${jsondata} 0
405 Log ${value}
406 ${jsonCamelCaseFieldnames}= Run Keyword And Return Status
407 ... Dictionary Should Contain Key ${value} adminState
408 ${astate}= Run Keyword If ${jsonCamelCaseFieldNames}
409 ... Get From Dictionary ${value} adminState
410 ... ELSE
411 ... Get From Dictionary ${value} adminstate
412 ${opstatus}= Run Keyword If ${jsonCamelCaseFieldNames}
413 ... Get From Dictionary ${value} operStatus
414 ... ELSE
415 ... Get From Dictionary ${value} operstatus
416 ${cstatus}= Run Keyword If ${jsonCamelCaseFieldNames}
417 ... Get From Dictionary ${value} connectStatus
418 ... ELSE
419 ... Get From Dictionary ${value} connectstatus
420 ${sn}= Run Keyword If ${jsonCamelCaseFieldNames}
421 ... Get From Dictionary ${value} serialNumber
422 ... ELSE
423 ... Get From Dictionary ${value} serialnumber
424 ${devId}= Get From Dictionary ${value} id
425 ${mib_state}= Get From Dictionary ${value} reason
426 Should Be Equal '${devId}' '${onu_id}' No match found for ${onu_id} to validate device
427 ... values=False
428 Should Be Equal '${astate}' '${admin_state}' Device ${sn} admin_state != ${admin_state}
429 ... values=False
430 Should Be Equal '${opstatus}' '${oper_status}' Device ${sn} oper_status != ${oper_status}
431 ... values=False
432 Should Be Equal '${cstatus}' '${connect_status}' Device ${sn} conn_status != ${connect_status}
433 ... values=False
434 Should Be Equal '${mib_state}' '${onu_reason}'
435 ... Device ${sn} mib_state incorrect (${mib_state}) values=False
436
TorstenThieme96fe9ee2021-10-21 10:24:08 +0000437Check all ONU OperStatus
438 [Documentation] Checks that all ONUs OperStatus is the required one.
439 [Arguments] ${List_ONU_Serial} ${oper_status}
440 ${cmd}= Catenate voltctl -c ${VOLTCTL_CONFIG} device list -m 8MB -f Type=brcm_openomci_onu
441 ... --format "{{.SerialNumber}}\t{{.AdminState}}\t{{.OperStatus}}\t{{.ConnectStatus}}\t{{.Reason}}"
442 ... | grep -v SERIALNUMBER | grep ${oper_status}
443 ${rc} ${output}= Run and Return Rc and Output ${cmd}
444 Should Be Equal As Integers ${rc} 0
445 @{Results}= Split String ${output} \n
446 FOR ${Line} IN @{Results}
447 @{words}= Split String ${Line} \t
448 ${sn}= Set Variable ${words[0]}
449 Remove Values From List ${List_ONU_Serial} ${sn}
450 END
451 Should Be Empty ${List_ONU_Serial} For ONUs ${List_ONU_Serial} OperStatus ${oper_status} not matched!
452
453Validate Last ONU Communication
454 [Documentation] Validates last communication with ONU.
455 [Arguments] ${validation_duration}=5s
456 ${cmd}= Catenate voltctl -c ${VOLTCTL_CONFIG} adapter list -f Type=brcm_openomci_onu
457 ... --format '{{gosince .LastCommunication}}'
458 ${rc} ${output}= Run and Return Rc and Output ${cmd}
459 Should Be Equal As Integers ${rc} 0
TorstenThieme70790282021-11-19 10:26:25 +0000460 ${lastcomm}= Convert Time ${output}
461 ${validduration}= Convert Time ${validation_duration}
TorstenThieme96fe9ee2021-10-21 10:24:08 +0000462 Should Be True ${lastcomm}<=${validduration}
463
464Get Onu Image List
465 [Documentation] Delivers the ONU device image list
466 [Arguments] ${dev_id}
467 ${rc} ${output}= Run and Return Rc and Output
468 ... voltctl -c ${VOLTCTL_CONFIG} device onuimage list ${dev_id}
469 [return] ${rc} ${output}
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000470
TorstenThieme9949b172020-06-16 10:00:15 +0000471Compare Lists
472 [Documentation]
473 ... Compares both lists and put all matches in the returned list
474 [Arguments] ${ListIterate} ${ListCompare}
475 @{list} = Create List
476 ${length} = Get Length ${ListIterate}
477 FOR ${INDEX} IN RANGE 0 ${length}
478 ${sn}= Get From List ${ListIterate} ${INDEX}
479 ${onu_id}= Get Index From List ${ListCompare} ${sn}
480 Run Keyword If -1 != ${onu_id} Append To List ${list} ${sn}
481 END
482 [Return] ${list}
483
Gilles Depatieb5682f82019-10-31 10:39:45 -0400484Validate Logical Device
485 [Documentation] Validate Logical Device is listed
Matteo Scandolo5899be12020-11-11 15:38:07 -0800486 ${rc} ${output}= Run and Return Rc and Output voltctl -c ${VOLTCTL_CONFIG} logicaldevice list -o json
Gilles Depatieb5682f82019-10-31 10:39:45 -0400487 Should Be Equal As Integers ${rc} 0
488 ${jsondata}= To Json ${output}
489 Log ${jsondata}
490 ${length}= Get Length ${jsondata}
491 FOR ${INDEX} IN RANGE 0 ${length}
492 ${value}= Get From List ${jsondata} ${INDEX}
493 ${devid}= Get From Dictionary ${value} id
Scott Baker2ab2a0c2020-06-05 12:51:47 -0700494 ${rootdev}= Get From Dictionary ${value} rootDeviceId
495 ${desc}= Get From Dictionary ${value} desc
496 ${sn}= Get From Dictionary ${desc} serialNum
Gilles Depatieb5682f82019-10-31 10:39:45 -0400497 Exit For Loop
498 END
499 Should Be Equal '${rootdev}' '${olt_device_id}' Root Device does not match ${olt_device_id} values=False
500 Should Be Equal '${sn}' '${BBSIM_OLT_SN}' Logical Device ${sn} does not match ${BBSIM_OLT_SN}
501 ... values=False
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700502 [Return] ${devid}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400503
504Validate Logical Device Ports
505 [Arguments] ${logical_device_id}
506 [Documentation] Validate Logical Device Ports are listed and are > 0
507 ${rc} ${output}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800508 ... voltctl -c ${VOLTCTL_CONFIG} logicaldevice port list ${logical_device_id} -o json
Gilles Depatieb5682f82019-10-31 10:39:45 -0400509 Should Be Equal As Integers ${rc} 0
510 ${jsondata}= To Json ${output}
511 Log ${jsondata}
512 ${length}= Get Length ${jsondata}
513 Should Be True ${length} > 0 Number of ports for ${logical_device_id} was 0
514
515Validate Logical Device Flows
516 [Arguments] ${logical_device_id}
517 [Documentation] Validate Logical Device Flows are listed and are > 0
518 ${rc} ${output}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800519 ... voltctl -c ${VOLTCTL_CONFIG} logicaldevice flows ${logical_device_id} -o json
Gilles Depatieb5682f82019-10-31 10:39:45 -0400520 Should Be Equal As Integers ${rc} 0
521 ${jsondata}= To Json ${output}
522 Log ${jsondata}
523 ${length}= Get Length ${jsondata}
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700524 Should Be True ${length} > 0 Number of flows for ${logical_device_id} was 0
Gilles Depatieb5682f82019-10-31 10:39:45 -0400525
Hardik Windlass1ed2eee2021-06-25 09:51:03 +0000526Retrieve ONU UNI Ports
527 [Arguments] ${onu_device_id}
528 [Documentation] Retrieves the list of Active and Enabled UNI ports from the ONU device
529 ${rc} ${output}= Run and Return Rc and Output
530 ... voltctl -c ${VOLTCTL_CONFIG} device port list ${onu_device_id} -o json
531 Should Be Equal As Integers ${rc} 0
532 ${jsondata}= To Json ${output}
533 Log ${jsondata}
534 ${length}= Get Length ${jsondata}
535 ${onu_uni_list}= Create List
536 FOR ${INDEX} IN RANGE 0 ${length}
537 ${value}= Get From List ${jsondata} ${INDEX}
538 ${type}= Get From Dictionary ${value} type
539 ${portno}= Get From Dictionary ${value} portNo
540 ${adminstate}= Get From Dictionary ${value} adminState
541 ${operstate}= Get From Dictionary ${value} operStatus
542 Run Keyword If '${type}'=='ETHERNET_UNI' and '${adminstate}'=='ENABLED' and '${operstate}'=='ACTIVE'
543 ... Append To List ${onu_uni_list} ${portno}
544 END
545 [Return] ${onu_uni_list}
546
Hardik Windlass16cdf962020-04-29 15:26:50 +0530547Retrieve OLT PON Ports
548 [Arguments] ${olt_device_id}
549 [Documentation] Retrieves the list of PON ports from the OLT device
550 ${rc} ${output}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800551 ... voltctl -c ${VOLTCTL_CONFIG} device port list ${olt_device_id} -o json
Hardik Windlass16cdf962020-04-29 15:26:50 +0530552 Should Be Equal As Integers ${rc} 0
553 ${jsondata}= To Json ${output}
554 Log ${jsondata}
555 ${length}= Get Length ${jsondata}
556 ${olt_pon_list}= Create List
557 FOR ${INDEX} IN RANGE 0 ${length}
558 ${value}= Get From List ${jsondata} ${INDEX}
559 ${type}= Get From Dictionary ${value} type
560 ${portno}= Get From Dictionary ${value} portNo
561 ${peers}= Get From Dictionary ${value} peers
562 ${len_peers}= Get Length ${peers}
563 Run Keyword If '${type}' == 'PON_OLT' and ${len_peers} > 0
564 ... Append To List ${olt_pon_list} ${portno}
565 END
566 [Return] ${olt_pon_list}
567
568Retrieve Peer List From OLT PON Port
TorstenThieme17d6fd22021-09-23 10:00:08 +0000569 [Arguments] ${olt_device_id} ${pon_port} ${expected_num_peers}=0
Hardik Windlass16cdf962020-04-29 15:26:50 +0530570 [Documentation] Retrieves the list of peer device ids list from the OLT PON port
571 ${rc} ${output}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800572 ... voltctl -c ${VOLTCTL_CONFIG} device port list ${olt_device_id} -o json
Hardik Windlass16cdf962020-04-29 15:26:50 +0530573 Should Be Equal As Integers ${rc} 0
574 ${jsondata}= To Json ${output}
575 Log ${jsondata}
576 ${length}= Get Length ${jsondata}
577 ${matched}= Set Variable False
578 FOR ${INDEX} IN RANGE 0 ${length}
579 ${value}= Get From List ${jsondata} ${INDEX}
580 ${type}= Get From Dictionary ${value} type
581 ${portno}= Get From Dictionary ${value} portNo
582 ${peers}= Get From Dictionary ${value} peers
583 ${matched}= Set Variable If '${type}' == 'PON_OLT' and '${portno}' == '${pon_port}' True False
584 Exit For Loop If ${matched}
585 END
586 Should Be True ${matched} No PON port found for OLT ${olt_device_id}
587 ${length}= Get Length ${peers}
TorstenThieme17d6fd22021-09-23 10:00:08 +0000588 Run Keyword If ${expected_num_peers}>0 Should Be Equal As Integers ${length} ${expected_num_peers}
589 ... Number of found peers does not match expected number ${length}:${expected_num_peers}
Hardik Windlass16cdf962020-04-29 15:26:50 +0530590 ${olt_peer_list}= Create List
591 FOR ${INDEX} IN RANGE 0 ${length}
592 ${value}= Get From List ${peers} ${INDEX}
593 ${peer_id}= Get From Dictionary ${value} deviceId
594 Append To List ${olt_peer_list} ${peer_id}
595 END
596 [Return] ${olt_peer_list}
597
598Validate OLT PON Port Status
599 [Arguments] ${olt_device_id} ${pon_port} ${admin_state} ${oper_status}
600 [Documentation] Verifies the state of the PON port of the OLT
601 ${rc} ${output}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800602 ... voltctl -c ${VOLTCTL_CONFIG} device port list ${olt_device_id} -o json
Hardik Windlass16cdf962020-04-29 15:26:50 +0530603 Should Be Equal As Integers ${rc} 0
604 ${jsondata}= To Json ${output}
605 Log ${jsondata}
606 ${length}= Get Length ${jsondata}
607 ${matched}= Set Variable False
608 FOR ${INDEX} IN RANGE 0 ${length}
609 ${value}= Get From List ${jsondata} ${INDEX}
610 ${type}= Get From Dictionary ${value} type
611 ${portno}= Get From Dictionary ${value} portNo
612 ${astate}= Get From Dictionary ${value} adminState
613 ${opstatus}= Get From Dictionary ${value} operStatus
614 ${matched}= Set Variable If '${type}' == 'PON_OLT' and '${portno}' == '${pon_port}' True False
615 Exit For Loop If ${matched}
616 END
617 Should Be True ${matched} No PON port found for OLT ${olt_device_id} ${pon_port}
618 Log ${value}
619 Should Be Equal '${astate}' '${admin_state}' OLT PON Port admin_state != ${admin_state}
620 ... values=False
621 Should Be Equal '${opstatus}' '${oper_status}' OLT PON Port oper_status != ${oper_status}
622 ... values=False
623
624DisableOrEnable OLT PON Port
625 [Arguments] ${operation} ${olt_device_id} ${portno}
626 [Documentation] Disables or Enables the PON port of the OLT
627 ${rc} ${output}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800628 ... voltctl -c ${VOLTCTL_CONFIG} device port ${operation} ${olt_device_id} ${portno}
Hardik Windlass16cdf962020-04-29 15:26:50 +0530629 Should Be Equal As Integers ${rc} 0
630
Gilles Depatieb5682f82019-10-31 10:39:45 -0400631Retrieve Peer List From OLT
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700632 [Arguments] ${olt_peer_list}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400633 [Documentation] Retrieve the list of peer device id list from port list
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700634 ${rc} ${output}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800635 ... voltctl -c ${VOLTCTL_CONFIG} device port list ${olt_device_id} -o json
Gilles Depatieb5682f82019-10-31 10:39:45 -0400636 Should Be Equal As Integers ${rc} 0
637 ${jsondata}= To Json ${output}
638 Log ${jsondata}
639 ${length}= Get Length ${jsondata}
Andy Bavierb63f6d22020-03-12 15:34:37 -0700640 ${matched}= Set Variable False
Gilles Depatieb5682f82019-10-31 10:39:45 -0400641 FOR ${INDEX} IN RANGE 0 ${length}
642 ${value}= Get From List ${jsondata} ${INDEX}
643 ${type}= Get From Dictionary ${value} type
644 ${peers}= Get From Dictionary ${value} peers
Andy Bavierb63f6d22020-03-12 15:34:37 -0700645 ${matched}= Set Variable If '${type}' == 'PON_OLT' True False
646 Exit For Loop If ${matched}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400647 END
Andy Bavierb63f6d22020-03-12 15:34:37 -0700648 Should Be True ${matched} No PON port found for OLT ${olt_device_id}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400649 ${length}= Get Length ${peers}
650 FOR ${INDEX} IN RANGE 0 ${length}
651 ${value}= Get From List ${peers} ${INDEX}
Hardik Windlass16cdf962020-04-29 15:26:50 +0530652 ${peer_id}= Get From Dictionary ${value} deviceId
Gilles Depatieb5682f82019-10-31 10:39:45 -0400653 Append To List ${olt_peer_list} ${peer_id}
654 END
655
656Validate OLT Peer Id List
657 [Arguments] ${olt_peer_id_list}
658 [Documentation] Match each entry in the ${olt_peer_id_list} against ONU device ids.
659 FOR ${peer_id} IN @{olt_peer_id_list}
660 Match OLT Peer Id ${peer_id}
661 END
662
663Match OLT Peer Id
664 [Arguments] ${olt_peer_id}
665 [Documentation] Lookup the OLT Peer Id in against the list of ONU device Ids
Matteo Scandolo5899be12020-11-11 15:38:07 -0800666 ${rc} ${output}= Run and Return Rc and Output voltctl -c ${VOLTCTL_CONFIG} device list -o json
Gilles Depatieb5682f82019-10-31 10:39:45 -0400667 Should Be Equal As Integers ${rc} 0
668 ${jsondata}= To Json ${output}
669 Log ${jsondata}
670 ${length}= Get Length ${jsondata}
Andy Bavierb63f6d22020-03-12 15:34:37 -0700671 ${matched}= Set Variable False
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700672 FOR ${INDEX} IN RANGE 0 ${length}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400673 ${value}= Get From List ${jsondata} ${INDEX}
674 ${devid}= Get From Dictionary ${value} id
Andy Bavierb63f6d22020-03-12 15:34:37 -0700675 ${matched}= Set Variable If '${devid}' == '${olt_peer_id}' True False
676 Exit For Loop If ${matched}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400677 END
Andy Bavierb63f6d22020-03-12 15:34:37 -0700678 Should Be True ${matched} Peer id ${olt_peer_id} does not match any ONU device id
Gilles Depatieb5682f82019-10-31 10:39:45 -0400679
680Validate ONU Peer Id
681 [Arguments] ${olt_device_id} ${List_ONU_Serial}
682 [Documentation] Match each ONU peer to that of the OLT device id
683 FOR ${onu_serial} IN @{List_ONU_Serial}
684 ${onu_dev_id}= Get Device ID From SN ${onu_serial}
685 Match ONU Peer Id ${onu_dev_id}
686 END
687
688Match ONU Peer Id
689 [Arguments] ${onu_dev_id}
690 [Documentation] Match an ONU peer to that of the OLT device id
David K. Bainbridgebd5ebd22020-02-04 10:01:18 -0800691 ${rc} ${output}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800692 ... voltctl -c ${VOLTCTL_CONFIG} device port list ${onu_dev_id} -o json
Gilles Depatieb5682f82019-10-31 10:39:45 -0400693 Should Be Equal As Integers ${rc} 0
694 ${jsondata}= To Json ${output}
695 Log ${jsondata}
696 ${length}= Get Length ${jsondata}
Andy Bavierb63f6d22020-03-12 15:34:37 -0700697 ${matched}= Set Variable False
Gilles Depatieb5682f82019-10-31 10:39:45 -0400698 FOR ${INDEX} IN RANGE 0 ${length}
699 ${value}= Get From List ${jsondata} ${INDEX}
700 ${type}= Get From Dictionary ${value} type
701 ${peers}= Get From Dictionary ${value} peers
Andy Bavierb63f6d22020-03-12 15:34:37 -0700702 ${matched}= Set Variable If '${type}' == 'PON_ONU' True False
703 Exit For Loop If ${matched}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400704 END
Andy Bavierb63f6d22020-03-12 15:34:37 -0700705 Should Be True ${matched} No PON port found for ONU ${onu_dev_id}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400706 ${length}= Get Length ${peers}
707 FOR ${INDEX} IN RANGE 0 ${length}
708 ${value}= Get From List ${peers} ${INDEX}
Hardik Windlass16cdf962020-04-29 15:26:50 +0530709 ${peer_id}= Get From Dictionary ${value} deviceId
Gilles Depatieb5682f82019-10-31 10:39:45 -0400710 END
711 Should Be Equal '${peer_id}' '${olt_device_id}'
712 ... Mismatch between ONU peer ${peer_id} and OLT device id ${olt_device_id} values=False
Kailash6f5acb62019-08-28 14:38:45 -0700713
Kailash6f5acb62019-08-28 14:38:45 -0700714Get Device ID From SN
715 [Arguments] ${serial_number}
716 [Documentation] Gets the device id by matching for ${serial_number}
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700717 ${rc} ${id}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800718 ... voltctl -c ${VOLTCTL_CONFIG} device list --filter=SerialNumber=${serial_number} --format='{{.Id}}'
Matteo Scandolo2769d2b2021-04-14 10:29:24 -0700719 Should Be Equal As Integers ${rc} 0 "Error while fetching device list from VOLTHA"
Andy Bavier8fca0452019-12-16 15:30:11 -0700720 Log ${id}
Kailash6f5acb62019-08-28 14:38:45 -0700721 [Return] ${id}
722
Suchitra Vemuri00d147d2019-09-13 13:07:32 -0700723Get Logical Device ID From SN
724 [Arguments] ${serial_number}
725 [Documentation] Gets the device id by matching for ${serial_number}
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700726 ${rc} ${id}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800727 ... voltctl -c ${VOLTCTL_CONFIG} logicaldevice list --filter=Desc.SerialNum=${serial_number} --format='{{.Id}}'
Andy Bavier8fca0452019-12-16 15:30:11 -0700728 Should Be Equal As Integers ${rc} 0
729 Log ${id}
Suchitra Vemuri00d147d2019-09-13 13:07:32 -0700730 [Return] ${id}
731
Gilles Depatieb5682f82019-10-31 10:39:45 -0400732Build ONU SN List
Andrea Campanella6391f842020-11-16 10:01:18 +0100733 [Arguments] ${serial_numbers} ${olt_serial_number}=${EMPTY} ${num_onus}=${num_all_onus}
734 [Documentation] Appends all ONU SNs for the given OLT to the ${serial_numbers} list
Gilles Depatieb5682f82019-10-31 10:39:45 -0400735 FOR ${INDEX} IN RANGE 0 ${num_onus}
TorstenThieme96fe9ee2021-10-21 10:24:08 +0000736 ${onu_sn}= Set Variable ${hosts.src[${INDEX}]['onu']}
737 # skip if we have already append this ONU
738 ${onu_id}= Get Index From List ${serial_numbers} ${onu_sn}
739 Continue For Loop If -1 != ${onu_id}
740 Run Keyword IF "${olt_serial_number}"=="${hosts.src[${INDEX}].olt}" or "${olt_serial_number}"=="${EMPTY}"
741 ... Append To List ${serial_numbers} ${onu_sn}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400742 END
743
TorstenThiemef3e492c2021-11-08 15:25:48 +0000744Build ONU Device Id List
745 [Arguments] ${device_ids} ${olt_serial_number}=${EMPTY} ${num_onus}=${num_all_onus}
746 [Documentation] Appends all ONU Device IDs for the given OLT to the ${serial_numbers} list
747 FOR ${INDEX} IN RANGE 0 ${num_onus}
748 ${onu_device_id}= Get Device ID From SN ${hosts.src[${INDEX}]['onu']}
749 # skip if we have already append this ONU
750 ${onu_id}= Get Index From List ${device_ids} ${onu_device_id}
751 Continue For Loop If -1 != ${onu_id}
752 Run Keyword IF "${olt_serial_number}"=="${hosts.src[${INDEX}].olt}" or "${olt_serial_number}"=="${EMPTY}"
753 ... Append To List ${device_ids} ${onu_device_id}
754 END
755
Gilles Depatieb5682f82019-10-31 10:39:45 -0400756Get SN From Device ID
757 [Arguments] ${device_id}
758 [Documentation] Gets the device id by matching for ${device_id}
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700759 ${rc} ${sn}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800760 ... voltctl -c ${VOLTCTL_CONFIG} device list --filter=Id=${device_id} --format='{{.SerialNumber}}'
Gilles Depatieb5682f82019-10-31 10:39:45 -0400761 Should Be Equal As Integers ${rc} 0
Andy Bavier8fca0452019-12-16 15:30:11 -0700762 Log ${sn}
Gilles Depatieb5682f82019-10-31 10:39:45 -0400763 [Return] ${sn}
764
Scott Baker60e570d2020-02-02 22:10:13 -0800765Get Parent ID From Device ID
766 [Arguments] ${device_id}
767 [Documentation] Gets the device id by matching for ${device_id}
768 ${rc} ${pid}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800769 ... voltctl -c ${VOLTCTL_CONFIG} device list --filter=Id=${device_id} --format='{{.ParentId}}'
Scott Baker60e570d2020-02-02 22:10:13 -0800770 Should Be Equal As Integers ${rc} 0
771 Log ${pid}
772 [Return] ${pid}
773
Kailash6f5acb62019-08-28 14:38:45 -0700774Validate Device Removed
775 [Arguments] ${id}
776 [Documentation] Verifys that device, ${serial_number}, has been removed
Matteo Scandolo5899be12020-11-11 15:38:07 -0800777 ${rc} ${output}= Run and Return Rc and Output voltctl -c ${VOLTCTL_CONFIG} device list -o json
Andy Bavier8fca0452019-12-16 15:30:11 -0700778 Should Be Equal As Integers ${rc} 0
Kailash6f5acb62019-08-28 14:38:45 -0700779 ${jsondata}= To Json ${output}
780 Log ${jsondata}
781 ${length}= Get Length ${jsondata}
782 @{ids}= Create List
Zack Williamsec53a1b2019-09-16 15:50:52 -0700783 FOR ${INDEX} IN RANGE 0 ${length}
784 ${value}= Get From List ${jsondata} ${INDEX}
785 ${device_id}= Get From Dictionary ${value} id
786 Append To List ${ids} ${device_id}
787 END
Suchitra Vemuri00d147d2019-09-13 13:07:32 -0700788 List Should Not Contain Value ${ids} ${id}
Suchitra Vemuricd2f64f2020-02-18 18:30:27 -0800789
Andrea Campanella4e507882020-11-26 11:33:11 +0100790Validate all ONUS for OLT Removed
791 [Arguments] ${num_all_onus} ${hosts} ${olt_serial_number} ${timeout}
792 [Documentation] Verifys that all the ONUS for OLT ${serial_number}, has been removed
793 FOR ${J} IN RANGE 0 ${num_all_onus}
794 ${src}= Set Variable ${hosts.src[${J}]}
795 Continue For Loop If "${olt_serial_number}"!="${src['olt']}"
796 Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s
797 ... Validate Device Removed ${src['onu']}
798 END
799
Suchitra Vemuricd2f64f2020-02-18 18:30:27 -0800800Reboot ONU
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000801 [Arguments] ${onu_id} ${validate_device}=True
Suchitra Vemuricd2f64f2020-02-18 18:30:27 -0800802 [Documentation] Using voltctl command reboot ONU and verify that ONU comes up to running state
Matteo Scandolo5899be12020-11-11 15:38:07 -0800803 ${rc} ${devices}= Run and Return Rc and Output voltctl -c ${VOLTCTL_CONFIG} device reboot ${onu_id}
Suchitra Vemuricd2f64f2020-02-18 18:30:27 -0800804 Should Be Equal As Integers ${rc} 0
TorstenThiemefd7e7ba2020-11-06 13:57:57 +0000805 Run Keyword If ${validate_device} Run Keyword And Continue On Failure Wait Until Keyword Succeeds
806 ... 60s 1s Validate ONU Device By Device Id ENABLED DISCOVERED REACHABLE rebooting ${onu_id}
Matteo Scandolo142e6272020-04-29 17:36:59 -0700807
808Assert ONUs in Voltha
809 [Arguments] ${count}
810 [Documentation] Check that a certain number of devices reached the ACTIVE/ENABLE state
811 ${rc1} ${devices}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800812 ... voltctl -c ${VOLTCTL_CONFIG} -m 8M device list | grep -v OLT | grep ACTIVE | wc -l
Matteo Scandolo142e6272020-04-29 17:36:59 -0700813 Should Be Equal As Integers ${rc1} 0
814 Should Be Equal As Integers ${devices} ${count}
815
816Wait for ONUs in VOLTHA
817 [Arguments] ${count}
818 [Documentation] Waits until a certain number of devices reached the ACTIVE/ENABLE state
819 Wait Until Keyword Succeeds 10m 5s Assert ONUs In Voltha ${count}
820
821Count Logical Devices flows
822 [Documentation] Count the flows across logical devices in VOLTHA
823 [Arguments] ${targetFlows}
824 ${output}= Get Logical Device List From Voltha
825 ${logical_devices}= To Json ${output}
826 ${total_flows}= Set Variable 0
827 FOR ${device} IN @{logical_devices}
828 ${rc} ${flows}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800829 ... voltctl -c ${VOLTCTL_CONFIG} logicaldevice flows ${device['id']} | grep -v ID | wc -l
Matteo Scandolo142e6272020-04-29 17:36:59 -0700830 Should Be Equal As Integers ${rc} 0
831 ${total_flows}= Evaluate ${total_flows} + ${flows}
832 END
Matteo Scandolo616daab2020-05-13 11:49:24 -0700833 ${msg}= Format String Found {total_flows} flows of {targetFlows} expected
834 ... total_flows=${total_flows} targetFlows=${targetFlows}
835 Log ${msg}
Matteo Scandolo142e6272020-04-29 17:36:59 -0700836 Should Be Equal As Integers ${targetFlows} ${total_flows}
837
838Wait for Logical Devices flows
839 [Documentation] Waits until the flows have been provisioned in the logical device
840 [Arguments] ${workflow} ${uni_count} ${olt_count} ${provisioned}
Andrea Campanella70cf0a72020-05-27 10:55:15 +0200841 ... ${withEapol} ${withDhcp} ${withIgmp} ${withLldp}
Matteo Scandolo142e6272020-04-29 17:36:59 -0700842 ${targetFlows}= Calculate flows by workflow ${workflow} ${uni_count} ${olt_count} ${provisioned}
Andrea Campanella70cf0a72020-05-27 10:55:15 +0200843 ... ${withEapol} ${withDhcp} ${withIgmp} ${withLldp}
Matteo Scandolo142e6272020-04-29 17:36:59 -0700844 Log ${targetFlows}
845 # TODO extend Validate Logical Device Flows to check the correct number of flows
846 Wait Until Keyword Succeeds 10m 5s Count Logical Devices flows ${targetFlows}
847
Matteo Scandolo616daab2020-05-13 11:49:24 -0700848Count OpenOLT Device Flows
849 [Documentation] Count the flows across openolt devices in VOLTHA
850 [Arguments] ${targetFlows}
851 ${output}= Get Device List from Voltha by type openolt
852 ${devices}= To Json ${output}
853 ${total_flows}= Set Variable 0
854 FOR ${device} IN @{devices}
855 ${rc} ${flows}= Run and Return Rc and Output
Matteo Scandolo5899be12020-11-11 15:38:07 -0800856 ... voltctl -c ${VOLTCTL_CONFIG} device flows ${device['id']} | grep -v ID | wc -l
Matteo Scandolo616daab2020-05-13 11:49:24 -0700857 Should Be Equal As Integers ${rc} 0
858 ${total_flows}= Evaluate ${total_flows} + ${flows}
859 END
860 ${msg}= Format String Found {total_flows} flows of {targetFlows} expected
861 ... total_flows=${total_flows} targetFlows=${targetFlows}
862 Log ${msg}
863 Should Be Equal As Integers ${targetFlows} ${total_flows}
864
865Wait for OpenOLT Devices flows
866 [Documentation] Waits until the flows have been provisioned in the openolt devices
867 [Arguments] ${workflow} ${uni_count} ${olt_count} ${provisioned}
Andrea Campanella70cf0a72020-05-27 10:55:15 +0200868 ... ${withEapol} ${withDhcp} ${withIgmp} ${withLldp}
Matteo Scandolo96dbe432020-05-28 10:51:57 -0700869 ${beforeFlows}= Calculate flows by workflow ${workflow} ${uni_count} ${olt_count} ${provisioned}
870 ... ${withEapol} ${withDhcp} ${withIgmp} ${withLldp}
Matteo Scandoloda854b02020-09-01 16:20:51 -0700871 # In the physical device we only have 2 data plane flows (on the PON) instead of 4
Matteo Scandolo96dbe432020-05-28 10:51:57 -0700872 ${afterFlows}= Evaluate ${beforeFlows} - (${uni_count} * 2)
Matteo Scandoloda854b02020-09-01 16:20:51 -0700873 # In the TT workflow we have multiple service,
874 # so we need to remove 6 flows per each UNI that are only on the ONU device
875 ${ttFlows}= Evaluate ${beforeFlows} - (${uni_count} * 6)
876 ${afterFlows}= Set Variable If $workflow=='tt' ${ttFlows} ${afterFlows}
Matteo Scandolo96dbe432020-05-28 10:51:57 -0700877 ${targetFlows}= Set Variable If $provisioned=='true' ${afterFlows} ${beforeFlows}
Matteo Scandolo616daab2020-05-13 11:49:24 -0700878 Log ${targetFlows}
Hardik Windlass2b37e712020-06-12 02:13:17 +0530879 Wait Until Keyword Succeeds 10m 5s Count OpenOLT Device Flows ${targetFlows}
Hardik Windlass17bd1142021-03-12 08:15:25 +0000880
Hardik Windlassba1bd272021-06-22 08:29:33 +0000881Validate ONU Device Image
882 [Documentation] Validates the ONU device image
883 [Arguments] ${data} ${image_version} ${dev_id} ${download_state} ${expected_reason} ${image_status}
884 ${jsondata}= To Json ${data}
885 ${length}= Get Length ${jsondata}
TorstenThiemef3e492c2021-11-08 15:25:48 +0000886 Should Not Be Equal As Integers ${length} 0 No record to validate device image
887 FOR ${J} IN RANGE 0 ${length}
888 ${value}= Get From List ${jsondata} ${J}
889 Log ${value}
890 ${deviceId}= Get From Dictionary ${value} deviceId
891 Should Contain ${dev_id} ${deviceId} No match found for ${deviceId} to validate device image!
892 ${imageState}= Get From Dictionary ${value} imageState
893 ${version}= Get From Dictionary ${imageState} version
894 ${dwlState}= Get From Dictionary ${imageState} downloadState
895 ${reason}= Get From Dictionary ${imageState} reason
896 ${imgStatus}= Get From Dictionary ${imageState} imageState
897 Should Be Equal '${version}' '${image_version}' Device ${dev_id}: '${version}' != '${image_version}'
898 ... values=False
899 Should Be Equal '${dwlState}' '${download_state}' Device ${dev_id}: '${dwlState}' != '${download_state}'
900 ... values=False
901 Should Be Equal '${reason}' '${expected_reason}' Device ${dev_id}: '${reason}' != '${expected_reason}'
902 ... values=False
903 Should Be Equal '${imgStatus}' '${image_status}' Device ${dev_id}: '${imgStatus}' != '${image_status}'
904 ... values=False
905 END
Hardik Windlassba1bd272021-06-22 08:29:33 +0000906
Hardik Windlass17bd1142021-03-12 08:15:25 +0000907Download ONU Device Image
908 [Documentation] Downloads the given ONU software image
Hardik Windlassba1bd272021-06-22 08:29:33 +0000909 [Arguments] ${ver} ${url} ${vendor} ${active} ${commit} ${crc} ${id}
TorstenThieme7cb9de72021-08-24 09:40:57 +0000910 ... ${download_state}=DOWNLOAD_STARTED ${expected_reason}=NO_ERROR ${image_state}=IMAGE_UNKNOWN
Hardik Windlassba1bd272021-06-22 08:29:33 +0000911 ${rc} ${output}= Run and Return Rc and Output
912 ... voltctl -c ${VOLTCTL_CONFIG} device onuimage download ${ver} ${url} ${vendor} ${active} ${commit} ${crc} ${id} -o json
913 Log ${output}
Hardik Windlass17bd1142021-03-12 08:15:25 +0000914 Should Be Equal As Integers ${rc} 0
TorstenThieme7cb9de72021-08-24 09:40:57 +0000915 Validate ONU Device Image ${output} ${ver} ${id} ${download_state} ${expected_reason} ${image_state}
Hardik Windlass17bd1142021-03-12 08:15:25 +0000916
917Activate ONU Device Image
Hardik Windlassba1bd272021-06-22 08:29:33 +0000918 [Documentation] Activates the given ONU software image
919 [Arguments] ${ver} ${commit} ${id}
Hardik Windlass17bd1142021-03-12 08:15:25 +0000920 ${rc} ${output}= Run and Return Rc and Output
Hardik Windlassba1bd272021-06-22 08:29:33 +0000921 ... voltctl -c ${VOLTCTL_CONFIG} device onuimage activate ${ver} ${commit} ${id} -o json
922 Log ${output}
923 Should Be Equal As Integers ${rc} 0
Andrea Campanellaf3b88f62021-10-01 18:43:03 +0200924 Validate ONU Device Image ${output} ${ver} ${id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_ACTIVATING
Hardik Windlassba1bd272021-06-22 08:29:33 +0000925
926Commit ONU Device Image
927 [Documentation] Commits the given ONU software image
928 [Arguments] ${ver} ${id}
929 ${rc} ${output}= Run and Return Rc and Output
930 ... voltctl -c ${VOLTCTL_CONFIG} device onuimage commit ${ver} ${id} -o json
931 Log ${output}
932 Should Be Equal As Integers ${rc} 0
Andrea Campanellaf3b88f62021-10-01 18:43:03 +0200933 Validate ONU Device Image ${output} ${ver} ${id} DOWNLOAD_SUCCEEDED NO_ERROR IMAGE_COMMITTING
Hardik Windlassba1bd272021-06-22 08:29:33 +0000934
TorstenThieme37165402021-09-03 11:39:40 +0000935Abort ONU Device Image
936 [Documentation] Aborts the given ONU software image
937 [Arguments] ${ver} ${id} ${download_state} ${expected_reason} ${image_state}
938 ${rc} ${output}= Run and Return Rc and Output
939 ... voltctl -c ${VOLTCTL_CONFIG} device onuimage abort ${ver} ${id} -o json
940 Log ${output}
941 Should Be Equal As Integers ${rc} 0
942 Validate ONU Device Image ${output} ${ver} ${id} ${download_state} ${expected_reason} ${image_state}
943
Andrea Campanellaf3b88f62021-10-01 18:43:03 +0200944Remove Adapter Image
945 [Documentation] Aborts the upgrade processing for a given ONU software image and thus removes the image from adapter
946 [Arguments] ${ver} ${id}
947 ${rc} ${output}= Run and Return Rc and Output
948 ... voltctl -c ${VOLTCTL_CONFIG} device onuimage abort ${ver} ${id} -o json
949 Log ${output}
950
TorstenThiemef3e492c2021-11-08 15:25:48 +0000951Remove Adapter Image from ONUs
952 [Documentation] Aborts the upgrade processing for a given ONU software image and thus removes the image from adapter
953 ... for the passed ONUs
954 [Arguments] ${ver} ${onu_id_list}
955 FOR ${onu_device_id} IN @{onu_id_list}
956 Remove Adapter Image ${ver} ${onu_device_id}
957 END
958
Hardik Windlassba1bd272021-06-22 08:29:33 +0000959Verify ONU Device Image Status
960 [Documentation] Verfies the ONU device image state
961 [Arguments] ${image_version} ${dev_id} ${download_state} ${expected_reason} ${image_state}
962 ${rc} ${output}= Run and Return Rc and Output
963 ... voltctl -c ${VOLTCTL_CONFIG} device onuimage status ${image_version} ${dev_id} -o json
964 Log ${output}
965 Should Be Equal As Integers ${rc} 0
966 Validate ONU Device Image ${output} ${image_version} ${dev_id} ${download_state} ${expected_reason}
967 ... ${image_state}
968
969Verify ONU Device Image List
970 [Documentation] Verfies the ONU device image list
TorstenThieme70790282021-11-19 10:26:25 +0000971 [Arguments] ${dev_id} ${image_version} ${committed} ${activated} ${valid} ${image_should_not_in_list}=False
Hardik Windlassba1bd272021-06-22 08:29:33 +0000972 ${rc} ${output}= Run and Return Rc and Output
973 ... voltctl -c ${VOLTCTL_CONFIG} device onuimage list ${dev_id} -o json
Hardik Windlass17bd1142021-03-12 08:15:25 +0000974 Should Be Equal As Integers ${rc} 0
975 ${jsondata}= To Json ${output}
976 Log ${jsondata}
977 ${length}= Get Length ${jsondata}
978 ${matched}= Set Variable False
979 FOR ${INDEX} IN RANGE 0 ${length}
980 ${value}= Get From List ${jsondata} ${INDEX}
Hardik Windlassba1bd272021-06-22 08:29:33 +0000981 ${version}= Get From Dictionary ${value} version
982 ${isCommited}= Get From Dictionary ${value} isCommited
983 ${isActive}= Get From Dictionary ${value} isActive
984 ${isValid}= Get From Dictionary ${value} isValid
985 ${matched}= Set Variable If '${version}' == '${image_version}' True False
Hardik Windlass17bd1142021-03-12 08:15:25 +0000986 Exit For Loop If ${matched}
987 END
TorstenThieme70790282021-11-19 10:26:25 +0000988 Run Keyword If ${image_should_not_in_list}
989 ... Should Not Be True ${matched} ONU Image found unexpectedly with Version ${image_version}
990 ... ELSE Should Be True ${matched} No ONU Image found with Version ${image_version}
991 Run Keyword If ${matched} Should Be Equal '${isCommited}' '${committed}'
992 ... Device ${dev_id}: '${isCommited}' != '${committed}' values=False
993 Run Keyword If ${matched} Should Be Equal '${isActive}' '${activated}'
994 ... Device ${dev_id}: '${isActive}' != '${activated}' values=False
995 Run Keyword If ${matched} Should Be Equal '${isValid}' '${valid}'
996 ... Device ${dev_id}: '${isValid}' != '${valid}' values=False
TorstenThiemeff9c9142021-04-08 07:21:34 +0000997
998# pm-data relevant keywords
999Read Default Interval From Pmconfig
1000 [Documentation] Reads default interval from pm config
1001 [Arguments] ${device_id}
1002 ${rc} ${result}= Run and Return Rc and Output voltctl device pmconfig get ${device_id}
1003 Should Be Equal As Integers ${rc} 0
1004 log ${result}
1005 @{words}= Split String ${result}
1006 ${interval}= Get From List ${words} 3
1007 log ${interval}
1008 [return] ${interval}
1009
1010Read Group Interval From Pmconfig
1011 [Documentation] Reads default interval from pm config
1012 [Arguments] ${device_id} ${group}
1013 ${rc} ${result}= Run and Return Rc and Output voltctl device pmconfig group list ${device_id} | grep ${group}
1014 Should Be Equal As Integers ${rc} 0
1015 log ${result}
1016 @{words}= Split String ${result}
1017 ${interval}= Get From List ${words} -1
1018 log ${interval}
1019 [return] ${interval}
1020
1021Set and Validate Default Interval
1022 [Documentation] Sets and validates default interval of pm data
1023 [Arguments] ${device_id} ${interval}
1024 ${rc} ${result}= Run and Return Rc and Output voltctl device pmconfig frequency set ${device_id} ${interval}
1025 Should Be Equal As Integers ${rc} 0
1026 log ${result}
1027 # workaround until unit will be printed out in voltctl - remove unit
1028 ${interval}= Get Substring ${interval} 0 -1
1029 Should Contain ${result} ${interval}
1030
1031Set and Validate Group Interval
1032 [Documentation] Sets and validates group interval of pm data
1033 [Arguments] ${device_id} ${interval} ${group}
1034 ${rc} ${result}= Run and Return Rc and Output voltctl device pmconfig group set ${device_id} ${group} ${interval}
1035 Should Be Equal As Integers ${rc} 0
1036 ${rc} ${result}= Run and Return Rc and Output voltctl device pmconfig group list ${device_id} | grep ${group}
1037 Should Be Equal As Integers ${rc} 0
1038 log ${result}
1039 # workaround until unit will be printed out in voltctl - remove unit
1040 ${interval}= Get Substring ${interval} 0 -1
1041 Should Contain ${result} ${interval}
1042
1043Read Group List
1044 [Documentation] Reads metric group list of given device
1045 [Arguments] ${device_id}
1046 ${rc} ${result}= Run and Return Rc and Output voltctl device pmconfig group list ${device_id} | grep -v GROUPNAME
1047 Should Be Equal As Integers ${rc} 0
1048 ${group_list} Create List
1049 ${interval_dict} Create Dictionary
1050 @{output}= Split String ${result} \n
1051 FOR ${Line} IN @{output}
1052 @{words}= Split String ${Line}
1053 ${group}= Set Variable ${words[0]}
1054 ${interval}= Set Variable ${words[2]}
1055 Append To List ${group_list} ${group}
1056 Set To Dictionary ${interval_dict} ${group}=${interval}
1057 END
1058 [return] ${group_list} ${interval_dict}
1059
1060Read Group Metric List
1061 [Documentation] Reads group metric list of given device and group
1062 [Arguments] ${device_id} ${group}
1063 ${cmd}= Catenate voltctl device pmconfig groupmetric list ${device_id} ${group} | grep -v SAMPLEFREQ
1064 ${rc} ${result}= Run and Return Rc and Output ${cmd}
1065 Should Be Equal As Integers ${rc} 0
1066 ${groupmetric_list} Create List
1067 @{output}= Split String ${result} \n
1068 FOR ${Line} IN @{output}
1069 @{words}= Split String ${Line}
1070 ${name}= Set Variable ${words[0]}
1071 ${type}= Set Variable ${words[1]}
1072 ${enabled}= Set Variable ${words[2]}
1073 ${subdict}= Create Dictionary type=${type} enabled=${enabled}
1074 ${dict}= Create Dictionary ${name}=${subdict}
1075 Append To List ${groupmetric_list} ${dict}
1076 END
1077 [return] ${groupmetric_list}
1078
1079Read Group Metric Dict
1080 [Documentation] Reads group metric list of given device and group
1081 [Arguments] ${device_id} ${group}
1082 ${cmd}= Catenate voltctl device pmconfig groupmetric list ${device_id} ${group} | grep -v SAMPLEFREQ
1083 ${rc} ${result}= Run and Return Rc and Output ${cmd}
1084 Should Be Equal As Integers ${rc} 0
1085 ${groupmetric_dict} Create Dictionary
1086 @{output}= Split String ${result} \n
1087 FOR ${Line} IN @{output}
1088 @{words}= Split String ${Line}
1089 ${name}= Set Variable ${words[0]}
1090 ${type}= Set Variable ${words[1]}
1091 ${enabled}= Set Variable ${words[2]}
1092 ${subdict}= Create Dictionary type=${type} enabled=${enabled}
1093 Set To Dictionary ${groupmetric_dict} ${name}=${subdict}
1094 END
1095 [return] ${groupmetric_dict}