blob: e2f7277ef86e3157e10467f5e06a0f4797637db7 [file] [log] [blame]
Kailash92764922019-07-25 08:21:39 -07001# Copyright 2017-present Open Networking Foundation
2#
3# Licensed under the Apache License, Version 2.0 (the "License");
4# you may not use this file except in compliance with the License.
5# You may obtain a copy of the License at
6#
7# http://www.apache.org/licenses/LICENSE-2.0
8#
9# Unless required by applicable law or agreed to in writing, software
10# distributed under the License is distributed on an "AS IS" BASIS,
11# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
12# See the License for the specific language governing permissions and
13# limitations under the License.
14
Zack Williamsec53a1b2019-09-16 15:50:52 -070015# use bash for pushd/popd, and to fail quickly. virtualenv's activate
16# has undefined variables, so no -u
Zack Williamsa8fe75a2020-01-10 14:25:27 -070017SHELL := bash -e -o pipefail
Kailash92764922019-07-25 08:21:39 -070018
Zack Williamsa8fe75a2020-01-10 14:25:27 -070019ROOT_DIR := $(shell dirname $(realpath $(lastword $(MAKEFILE_LIST))))
Kailash92764922019-07-25 08:21:39 -070020
Zack Williamsa8fe75a2020-01-10 14:25:27 -070021# Configuration and lists of files for linting/testing
22VERSION ?= $(shell cat ./VERSION)
Suchitra Vemuria6879aa2020-11-03 11:03:11 -080023LINT_ARGS ?= --verbose --configure LineTooLong:130 -e LineTooLong \
Hardik Windlass98802ce2021-11-12 14:09:26 +000024 --configure TooManyTestSteps:65 -e TooManyTestSteps \
Scott Baker27d04db2020-02-06 18:03:21 -080025 --configure TooManyTestCases:50 -e TooManyTestCases \
Zack Williamsa8fe75a2020-01-10 14:25:27 -070026 --configure TooFewTestSteps:1 \
27 --configure TooFewKeywordSteps:1 \
Hardik Windlassa7b34be2022-03-22 17:28:31 +000028 --configure FileTooLong:2000 -e FileTooLong \
Zack Williamsa8fe75a2020-01-10 14:25:27 -070029 -e TrailingWhitespace
30
31PYTHON_FILES := $(wildcard libraries/*.py)
32ROBOT_FILES := $(shell find . -name *.robot -print)
33YAML_FILES := $(shell find ./tests -type f \( -name *.yaml -o -name *.yml \) -print)
34JSON_FILES := $(shell find ./tests -name *.json -print)
35
36# Robot config
37ROBOT_SANITY_SINGLE_PON_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind.yaml
Hardik Windlassa3d04b92020-02-17 15:06:05 +000038ROBOT_SANITY_DT_SINGLE_PON_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-dt.yaml
Suchitra Vemuria311faf2020-11-23 13:46:52 -080039ROBOT_SANITY_MULTIPLE_OLT_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-2OLTx2ONUx2PON.yaml
TorstenThieme379c3da2021-03-23 10:27:32 +000040ROBOT_SANITY_DT_MULTIPLE_OLT_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-2OLTx2ONUx2PON-dt.yaml
41ROBOT_SANITY_TT_MULTIPLE_OLT_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-2OLTx2ONUx2PON-tt.yaml
Zack Williamsa8fe75a2020-01-10 14:25:27 -070042ROBOT_FAIL_SINGLE_PON_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind.yaml
43ROBOT_SANITY_MULT_PON_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-2x2.yaml
44ROBOT_SCALE_SINGLE_PON_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-16.yaml
45ROBOT_SCALE_MULT_PON_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-8x2.yaml
TorstenThiemeffb33922020-06-18 08:41:17 +000046ROBOT_SCALE_MULT_ONU_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-8x8.yaml
Zack Williamsa8fe75a2020-01-10 14:25:27 -070047ROBOT_DEBUG_LOG_OPT ?=
48ROBOT_MISC_ARGS ?=
Matteo Scandolo549df9e2020-09-04 11:09:18 -070049ROBOT_SANITY_TT_SINGLE_PON_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-tt.yaml
uwe ottrembka504ca3e2020-11-23 12:02:20 +010050ROBOT_DMI_SINGLE_BBSIM_FILE ?= $(ROOT_DIR)/tests/data/dmi-components-bbsim.yaml
TorstenThiemef8f9a802020-12-16 15:25:25 +000051ROBOT_DMI_SINGLE_ADTRAN_FILE ?= $(ROOT_DIR)/tests/data/dmi-components-adtran.yaml
Hardik Windlass17bd1142021-03-12 08:15:25 +000052ROBOT_SW_UPGRADE_FILE ?= $(ROOT_DIR)/tests/data/software-upgrade.yaml
TorstenThiemeff9c9142021-04-08 07:21:34 +000053ROBOT_PM_DATA_FILE ?= $(ROOT_DIR)/tests/data/pm-data.yaml
Hardik Windlass1ed2eee2021-06-25 09:51:03 +000054ROBOT_SANITY_MULTI_UNI_SINGLE_PON_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-multi-uni.yaml
55ROBOT_SANITY_MULTI_UNI_MULTIPLE_OLT_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-multi-uni-2OLTx2ONUx2PON.yaml
56ROBOT_SANITY_TT_MULTI_UNI_SINGLE_PON_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-multi-uni-tt.yaml
TorstenThieme00fe8262022-01-19 10:43:07 +000057ROBOT_SANITY_TT_MULTI_UNI_MULTIPLE_OLT_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-multi-uni-2OLTx2ONUx2PON-tt.yaml
Hardik Windlassa7b34be2022-03-22 17:28:31 +000058ROBOT_SANITY_DT_FTTB_SINGLE_PON_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-dt-fttb-1OLTx1PONx2ONUx2UNI.yaml
Andrea Speranzaa8cf80b2022-05-26 10:09:59 +020059ROBOT_SANITY_TIM_SINGLE_PON_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-tim.yaml
60ROBOT_SANITY_TIM_SINGLE_PON_MULTI_ONU_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-tim-OLTxPONx2ONU.yaml
61ROBOT_SANITY_TIM_MULTI_PON_MULTI_ONU_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-tim-OLTx2PONx2ONU.yaml
62ROBOT_SANITY_TIM_MULTI_OLT_MULTI_PON_MULTI_ONU_FILE ?= $(ROOT_DIR)/tests/data/bbsim-kind-tim-2OLTx2PONx2ONU.yaml
63
Zack Williamsa8fe75a2020-01-10 14:25:27 -070064
Gilles Depatie45fbe042019-11-11 17:10:06 -050065# for backwards compatibility
66sanity-kind: sanity-single-kind
67
Matteo Scandolod7ca7f22021-01-26 14:10:37 -080068# to simplify ci
69sanity-kind-att: sanity-single-kind
70
Hardik Windlass1ed2eee2021-06-25 09:51:03 +000071# ATT Multi-UNI Sanity Target
72sanity-kind-multiuni-att: ROBOT_MISC_ARGS += -X -i sanity $(ROBOT_DEBUG_LOG_OPT)
73sanity-kind-multiuni-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTI_UNI_SINGLE_PON_FILE)
74sanity-kind-multiuni-att: ROBOT_FILE := Voltha_PODTests.robot
75sanity-kind-multiuni-att: voltha-test
76
77# ATT Multi-UNI Functional Suite Target
78functional-single-kind-multiuni-att: ROBOT_MISC_ARGS += -X -i sanityORmulti-uni $(ROBOT_DEBUG_LOG_OPT)
79functional-single-kind-multiuni-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTI_UNI_SINGLE_PON_FILE)
80functional-single-kind-multiuni-att: ROBOT_FILE := Voltha_PODTests.robot
81functional-single-kind-multiuni-att: voltha-test
82
Matteo Scandolo142e6272020-04-29 17:36:59 -070083# for scale pipeline
Hardik Windlass513afd12021-02-03 15:19:46 +000084voltha-scale: ROBOT_MISC_ARGS += -i activation -v NAMESPACE:voltha $(ROBOT_DEBUG_LOG_OPT)
Matteo Scandolo142e6272020-04-29 17:36:59 -070085voltha-scale: voltha-scale-test
86
Hardik Windlassf8b3ee62022-01-24 16:36:32 +000087# for onu-upgrade scale pipeline
88# Requirement: Pass ONU image details in following parameters
89# image_version, image_url, image_vendor, image_activate_on_success, image_commit_on_success, image_crc
90voltha-scale-onu-upgrade: ROBOT_MISC_ARGS += -i setup -i activation -i onu-upgrade -v NAMESPACE:voltha -v image_version:BBSM_IMG_00002 -v image_url:http://bbsim0:50074/images/software-image.img -v image_vendor:BBSM -v image_activate_on_success:false -v image_commit_on_success:false -v image_crc:0 $(ROBOT_DEBUG_LOG_OPT)
91voltha-scale-onu-upgrade: voltha-scale-test
92
Hardik Windlassa3d04b92020-02-17 15:06:05 +000093# target to invoke DT Workflow Sanity
94sanity-kind-dt: ROBOT_MISC_ARGS += -i sanityDt $(ROBOT_DEBUG_LOG_OPT)
95sanity-kind-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_SINGLE_PON_FILE)
96sanity-kind-dt: ROBOT_FILE := Voltha_DT_PODTests.robot
97sanity-kind-dt: voltha-dt-test
98
Hardik Windlassa7b34be2022-03-22 17:28:31 +000099# target to invoke DT FTTB Workflow Sanity
100sanity-kind-dt-fttb: ROBOT_MISC_ARGS += -i sanityDtFttb $(ROBOT_DEBUG_LOG_OPT)
101sanity-kind-dt-fttb: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_FTTB_SINGLE_PON_FILE)
102sanity-kind-dt-fttb: ROBOT_FILE := Voltha_DT_FTTB_Tests.robot
103sanity-kind-dt-fttb: voltha-dt-test
104
Hardik Windlassd6aa0822020-06-29 20:18:12 +0530105functional-single-kind: ROBOT_MISC_ARGS += -i sanityORfunctional -e PowerSwitch $(ROBOT_DEBUG_LOG_OPT)
Andy Bavier33e6dd32020-01-16 13:35:20 -0700106functional-single-kind: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
107functional-single-kind: bbsim-kind
108
Matteo Scandolod7ca7f22021-01-26 14:10:37 -0800109# to simplify ci
110functional-single-kind-att: functional-single-kind
111
Hardik Windlass35706ba2020-02-20 08:16:42 +0000112# target to invoke DT Workflow Functional scenarios
Hardik Windlassd6aa0822020-06-29 20:18:12 +0530113functional-single-kind-dt: ROBOT_MISC_ARGS += -i sanityDtORfunctionalDt -e PowerSwitch $(ROBOT_DEBUG_LOG_OPT)
Hardik Windlass35706ba2020-02-20 08:16:42 +0000114functional-single-kind-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_SINGLE_PON_FILE)
115functional-single-kind-dt: ROBOT_FILE := Voltha_DT_PODTests.robot
116functional-single-kind-dt: voltha-dt-test
117
Suchitra Vemuri2f1e07d2020-06-26 19:18:01 -0700118# target to invoke TT Workflow Sanity
Hardik Windlass43118692020-07-01 22:16:47 +0530119sanity-kind-tt: ROBOT_MISC_ARGS += -i sanityTT $(ROBOT_DEBUG_LOG_OPT)
120sanity-kind-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_SINGLE_PON_FILE)
121sanity-kind-tt: ROBOT_FILE := Voltha_TT_PODTests.robot
122sanity-kind-tt: voltha-tt-test
Suchitra Vemuri2f1e07d2020-06-26 19:18:01 -0700123
Hardik Windlassc609eb02022-02-22 11:28:37 +0000124sanity-kind-tt-maclearning: ROBOT_MISC_ARGS += -i sanityTT -v with_maclearning:True $(ROBOT_DEBUG_LOG_OPT)
125sanity-kind-tt-maclearning: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_SINGLE_PON_FILE)
126sanity-kind-tt-maclearning: ROBOT_FILE := Voltha_TT_PODTests.robot
127sanity-kind-tt-maclearning: voltha-tt-test
128
Hardik Windlass1ed2eee2021-06-25 09:51:03 +0000129sanity-kind-multiuni-tt: ROBOT_MISC_ARGS += -i sanityTT $(ROBOT_DEBUG_LOG_OPT)
130sanity-kind-multiuni-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_MULTI_UNI_SINGLE_PON_FILE)
131sanity-kind-multiuni-tt: ROBOT_FILE := Voltha_TT_PODTests.robot
132sanity-kind-multiuni-tt: voltha-tt-test
133
Suchitra Vemuri2f1e07d2020-06-26 19:18:01 -0700134# target to invoke TT Workflow Functional scenarios
Hardik Windlass1ed2eee2021-06-25 09:51:03 +0000135functional-single-kind-tt: ROBOT_MISC_ARGS += -i sanityTTORfunctionalTT -e PowerSwitch $(ROBOT_DEBUG_LOG_OPT)
Suchitra Vemuri2f1e07d2020-06-26 19:18:01 -0700136functional-single-kind-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_SINGLE_PON_FILE)
137functional-single-kind-tt: ROBOT_FILE := Voltha_TT_PODTests.robot
138functional-single-kind-tt: voltha-tt-test
139
Hardik Windlass1ed2eee2021-06-25 09:51:03 +0000140functional-single-kind-multiuni-tt: ROBOT_MISC_ARGS += -i sanityTTORfunctionalTT -e PowerSwitch $(ROBOT_DEBUG_LOG_OPT)
141functional-single-kind-multiuni-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_MULTI_UNI_SINGLE_PON_FILE)
142functional-single-kind-multiuni-tt: ROBOT_FILE := Voltha_TT_PODTests.robot
143functional-single-kind-multiuni-tt: voltha-tt-test
144
Andrea Speranzaa8cf80b2022-05-26 10:09:59 +0200145# target to invoke TIM Workflow Sanity
146sanity-kind-tim: ROBOT_MISC_ARGS += -i sanityTIM $(ROBOT_DEBUG_LOG_OPT)
147sanity-kind-tim: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TIM_SINGLE_PON_FILE)
148sanity-kind-tim: ROBOT_FILE := Voltha_TIM_PODTests.robot
149sanity-kind-tim: voltha-tim-test
150
151sanity-kind-tim-multi-onu: ROBOT_MISC_ARGS += -i sanityTIM $(ROBOT_DEBUG_LOG_OPT)
152sanity-kind-tim-multi-onu: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TIM_SINGLE_PON_MULTI_ONU_FILE)
153sanity-kind-tim-multi-onu: ROBOT_FILE := Voltha_TIM_PODTests.robot
154sanity-kind-tim-multi-onu: voltha-tim-test
155
156sanity-kind-tim-multi-pon-multi-onu: ROBOT_MISC_ARGS += -i sanityTIM $(ROBOT_DEBUG_LOG_OPT)
157sanity-kind-tim-multi-pon-multi-onu: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TIM_MULTI_PON_MULTI_ONU_FILE)
158sanity-kind-tim-multi-pon-multi-onu: ROBOT_FILE := Voltha_TIM_PODTests.robot
159sanity-kind-tim-multi-pon-multi-onu: voltha-tim-test
160
161sanity-kind-tim-multi-olt-multi-pon-multi-onu: ROBOT_MISC_ARGS += -i sanityTIM $(ROBOT_DEBUG_LOG_OPT)
162sanity-kind-tim-multi-olt-multi-pon-multi-onu: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TIM_MULTI_OLT_MULTI_PON_MULTI_ONU_FILE)
163sanity-kind-tim-multi-olt-multi-pon-multi-onu: ROBOT_FILE := Voltha_TIM_PODTests.robot
164sanity-kind-tim-multi-olt-multi-pon-multi-onu: voltha-tim-test
165
166
TorstenThiemebccd3ae2020-02-20 12:56:44 +0000167# target to invoke multiple OLTs Functional scenarios
Suchitra Vemuri2a6975a2020-11-25 12:49:38 -0800168functional-multi-olt: ROBOT_MISC_ARGS += -i sanityORfunctional -e PowerSwitch $(ROBOT_DEBUG_LOG_OPT)
TorstenThiemebccd3ae2020-02-20 12:56:44 +0000169functional-multi-olt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTIPLE_OLT_FILE)
Suchitra Vemuri9826c052020-11-18 14:11:51 -0800170functional-multi-olt: ROBOT_FILE := Voltha_PODTests.robot
TorstenThiemebccd3ae2020-02-20 12:56:44 +0000171functional-multi-olt: voltha-test
172
Hardik Windlass1ed2eee2021-06-25 09:51:03 +0000173functional-multiuni-multiolt-att: ROBOT_MISC_ARGS += -X -i sanityORmulti-uni $(ROBOT_DEBUG_LOG_OPT)
174functional-multiuni-multiolt-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTI_UNI_MULTIPLE_OLT_FILE)
175functional-multiuni-multiolt-att: ROBOT_FILE := Voltha_PODTests.robot
176functional-multiuni-multiolt-att: voltha-test
177
TorstenThieme90a99f82021-05-05 09:17:37 +0000178# target to invoke test with openonu go adapter applying 1T1GEM tech-profile at single ONU
1791t1gem-openonu-go-adapter-test: ROBOT_MISC_ARGS += -v techprofile:1T1GEM
1801t1gem-openonu-go-adapter-test: openonu-go-adapter-test
181
TorstenThiemefe7099e2021-01-29 08:41:04 +0000182# target to invoke test with openonu go adapter applying 1T4GEM tech-profile at single ONU
1831t4gem-openonu-go-adapter-test: ROBOT_MISC_ARGS += -v techprofile:1T4GEM
1841t4gem-openonu-go-adapter-test: openonu-go-adapter-test
185
186# target to invoke test with openonu go adapter applying 1T8GEM tech-profile at single ONU
1871t8gem-openonu-go-adapter-test: ROBOT_MISC_ARGS += -v techprofile:1T8GEM
1881t8gem-openonu-go-adapter-test: openonu-go-adapter-test
189
TorstenThieme1619db22020-04-03 12:01:15 +0000190# target to invoke openonu go adapter
TorstenThieme66c91a82020-10-19 13:37:53 +0000191openonu-go-adapter-test: ROBOT_MISC_ARGS += -v state2test:omci-flows-pushed -v testmode:SingleStateTime
Hardik Windlass9e3db232021-10-14 07:10:47 +0000192openonu-go-adapter-test: ROBOT_MISC_ARGS += -i sanityOnuGo -i functionalOnuGo
TorstenThieme41097be2021-07-06 09:52:50 +0000193openonu-go-adapter-test: ROBOT_MISC_ARGS += -e notreadyOnuGo $(ROBOT_DEBUG_LOG_OPT)
TorstenThieme1619db22020-04-03 12:01:15 +0000194openonu-go-adapter-test: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
195openonu-go-adapter-test: ROBOT_FILE := Voltha_ONUStateTests.robot
TorstenThieme89caa142020-10-05 08:20:31 +0000196openonu-go-adapter-test: openonu-go-adapter-tests
TorstenThieme1619db22020-04-03 12:01:15 +0000197
TorstenThieme89caa142020-10-05 08:20:31 +0000198# target to invoke test with openonu go adapter applying MIB-Upload-Templating
Hardik Windlass9e3db232021-10-14 07:10:47 +0000199mib-upload-templating-openonu-go-adapter-test: ROBOT_MISC_ARGS += -i functionalOnuGo
TorstenThieme5db695e2022-04-01 08:19:05 +0000200mib-upload-templating-openonu-go-adapter-test: ROBOT_MISC_ARGS += -e notreadyOnuGo $(ROBOT_DEBUG_LOG_OPT)
TorstenThieme89caa142020-10-05 08:20:31 +0000201mib-upload-templating-openonu-go-adapter-test: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULT_PON_FILE)
202mib-upload-templating-openonu-go-adapter-test: ROBOT_FILE := Voltha_ONUTemplateTests.robot
203mib-upload-templating-openonu-go-adapter-test: openonu-go-adapter-tests
TorstenThieme280c3802020-08-07 07:07:42 +0000204
TorstenThieme53450ff2021-05-11 09:44:33 +0000205# target to invoke test with openonu go adapter applying 1T8GEM tech-profile at single ONU with OMCI hardening
206# timeout is determined for omci_response_rate=9 and omci_timeout=1s
207openonu-go-adapter-omci-hardening-passed-test: ROBOT_MISC_ARGS += -v timeout:180s -v techprofile:1T8GEM
208openonu-go-adapter-omci-hardening-passed-test: openonu-go-adapter-test
209
210# target to invoke openonu go adapter failed state test at single ONU with OMCI hardening
211# test should show in case of too small omci_response_rate (<=7) in BBSIM that OMCI hardening does not work
212# test is PASS when ONU does not leave state 'starting-openomci'
Hardik Windlass9e3db232021-10-14 07:10:47 +0000213openonu-go-adapter-omci-hardening-failed-test: ROBOT_MISC_ARGS += -v timeout:300s -i NegativeStateTestOnuGo
TorstenThieme5db695e2022-04-01 08:19:05 +0000214openonu-go-adapter-omci-hardening-failed-test: ROBOT_MISC_ARGS += -e notreadyOnuGo $(ROBOT_DEBUG_LOG_OPT)
TorstenThieme53450ff2021-05-11 09:44:33 +0000215openonu-go-adapter-omci-hardening-failed-test: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
216openonu-go-adapter-omci-hardening-failed-test: ROBOT_FILE := Voltha_ONUNegativeStateTests.robot
217openonu-go-adapter-omci-hardening-failed-test: openonu-go-adapter-tests
218
TorstenThieme379c3da2021-03-23 10:27:32 +0000219# target to invoke reconcile tests with openonu go adapter at single ONU with ATT workflow (default workflow)
TorstenThieme90a99f82021-05-05 09:17:37 +0000220reconcile-openonu-go-adapter-test-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
221reconcile-openonu-go-adapter-test-att: reconcile-openonu-go-adapter-tests-att
TorstenThieme3d8bf552021-02-08 08:41:52 +0000222
TorstenThiemefe7099e2021-01-29 08:41:04 +0000223# target to invoke reconcile tests with openonu go adapter at single ONU with DT workflow
TorstenThieme3d8bf552021-02-08 08:41:52 +0000224reconcile-openonu-go-adapter-test-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_SINGLE_PON_FILE)
TorstenThieme379c3da2021-03-23 10:27:32 +0000225reconcile-openonu-go-adapter-test-dt: reconcile-openonu-go-adapter-tests-dt
TorstenThiemefe7099e2021-01-29 08:41:04 +0000226
227# target to invoke reconcile tests with openonu go adapter at single ONU with TT workflow
TorstenThieme3d8bf552021-02-08 08:41:52 +0000228reconcile-openonu-go-adapter-test-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_SINGLE_PON_FILE)
TorstenThieme379c3da2021-03-23 10:27:32 +0000229reconcile-openonu-go-adapter-test-tt: reconcile-openonu-go-adapter-tests-tt
TorstenThiemefe7099e2021-01-29 08:41:04 +0000230
TorstenThieme00fe8262022-01-19 10:43:07 +0000231# target to invoke reconcile tests with openonu go adapter at single ONU multi UNI with TT workflow
232reconcile-openonu-go-adapter-multi-uni-test-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_MULTI_UNI_SINGLE_PON_FILE)
233reconcile-openonu-go-adapter-multi-uni-test-tt: ROBOT_MISC_ARGS += -v unitag_sub:True
234reconcile-openonu-go-adapter-multi-uni-test-tt: reconcile-openonu-go-adapter-tests-tt
235
TorstenThieme379c3da2021-03-23 10:27:32 +0000236# target to invoke reconcile tests with openonu go adapter with multiple OLTs scenario with ATT workflow (default workflow)
TorstenThieme90a99f82021-05-05 09:17:37 +0000237reconcile-openonu-go-adapter-multi-olt-test-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTIPLE_OLT_FILE)
238reconcile-openonu-go-adapter-multi-olt-test-att: reconcile-openonu-go-adapter-tests-att
TorstenThieme379c3da2021-03-23 10:27:32 +0000239
240# target to invoke reconcile tests with openonu go adapter with multiple OLTs scenario with DT workflow
241reconcile-openonu-go-adapter-multi-olt-test-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_MULTIPLE_OLT_FILE)
242reconcile-openonu-go-adapter-multi-olt-test-dt: reconcile-openonu-go-adapter-tests-dt
243
244# target to invoke reconcile tests with openonu go adapter with multiple OLTs scenario with TT workflow
245reconcile-openonu-go-adapter-multi-olt-test-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_MULTIPLE_OLT_FILE)
246reconcile-openonu-go-adapter-multi-olt-test-tt: reconcile-openonu-go-adapter-tests-tt
247
TorstenThieme00fe8262022-01-19 10:43:07 +0000248# target to invoke reconcile tests with openonu go adapter with multiple OLTs multi UNI scenario with TT workflow
249reconcile-openonu-go-adapter-multi-olt-multi-uni-test-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_MULTI_UNI_MULTIPLE_OLT_FILE)
250reconcile-openonu-go-adapter-multi-olt-multi-uni-test-tt: ROBOT_MISC_ARGS += -v unitag_sub:True
251reconcile-openonu-go-adapter-multi-olt-multi-uni-test-tt: reconcile-openonu-go-adapter-tests-tt
252
TorstenThieme90a99f82021-05-05 09:17:37 +0000253# target to invoke reconcile tests with openonu go adapter with ATT workflow
254reconcile-openonu-go-adapter-tests-att: ROBOT_MISC_ARGS += -v workflow:ATT
255reconcile-openonu-go-adapter-tests-att: reconcile-openonu-go-adapter-tests
256
TorstenThieme379c3da2021-03-23 10:27:32 +0000257# target to invoke reconcile tests with openonu go adapter with DT workflow
258reconcile-openonu-go-adapter-tests-dt: ROBOT_MISC_ARGS += -v workflow:DT
259reconcile-openonu-go-adapter-tests-dt: reconcile-openonu-go-adapter-tests
260
261# target to invoke reconcile tests with openonu go adapter with TT workflow
262reconcile-openonu-go-adapter-tests-tt: ROBOT_MISC_ARGS += -v workflow:TT
263reconcile-openonu-go-adapter-tests-tt: reconcile-openonu-go-adapter-tests
264
265# target to invoke reconcile tests with openonu go adapter at single ONU resp. multiple OLTs
Hardik Windlass9e3db232021-10-14 07:10:47 +0000266reconcile-openonu-go-adapter-tests: ROBOT_MISC_ARGS += -i functionalOnuGo
TorstenThieme0ec95eb2021-11-23 14:56:26 +0000267reconcile-openonu-go-adapter-tests: ROBOT_MISC_ARGS += -e notreadyOnuGo $(ROBOT_DEBUG_LOG_OPT)
TorstenThieme3d8bf552021-02-08 08:41:52 +0000268reconcile-openonu-go-adapter-tests: ROBOT_FILE := Voltha_ONUReconcileTests.robot
269reconcile-openonu-go-adapter-tests: openonu-go-adapter-tests
TorstenThieme440b7c02020-12-18 15:42:57 +0000270
TorstenThieme90a99f82021-05-05 09:17:37 +0000271# target to invoke test with openonu go adapter applying 1T1GEM tech-profile with multiple OLTs scenarios with ATT workflow
2721t1gem-openonu-go-adapter-multi-olt-test: ROBOT_MISC_ARGS += -v techprofile:1T1GEM
2731t1gem-openonu-go-adapter-multi-olt-test: openonu-go-adapter-multi-olt-test
274
TorstenThiemefe7099e2021-01-29 08:41:04 +0000275# target to invoke test with openonu go adapter applying 1T4GEM tech-profile with multiple OLTs scenarios with ATT workflow
2761t4gem-openonu-go-adapter-multi-olt-test: ROBOT_MISC_ARGS += -v techprofile:1T4GEM
2771t4gem-openonu-go-adapter-multi-olt-test: openonu-go-adapter-multi-olt-test
TorstenThiemec3c23232021-01-13 13:06:31 +0000278
TorstenThiemefe7099e2021-01-29 08:41:04 +0000279# target to invoke test with openonu go adapter applying 1T8GEM tech-profile with multiple OLTs scenarios with ATT workflow
2801t8gem-openonu-go-adapter-multi-olt-test: ROBOT_MISC_ARGS += -v techprofile:1T8GEM
TorstenThieme3d8bf552021-02-08 08:41:52 +00002811t8gem-openonu-go-adapter-multi-olt-test: openonu-go-adapter-multi-olt-test
TorstenThiemefe7099e2021-01-29 08:41:04 +0000282
283# target to invoke test with openonu go adapter (applying 1T1GEM tech-profile) with multiple OLTs scenarios with ATT workflow
284openonu-go-adapter-multi-olt-test: ROBOT_MISC_ARGS += -v state2test:omci-flows-pushed -v testmode:SingleStateTime
Hardik Windlass9e3db232021-10-14 07:10:47 +0000285openonu-go-adapter-multi-olt-test: ROBOT_MISC_ARGS += -i sanityOnuGo -i functionalOnuGo
TorstenThieme41097be2021-07-06 09:52:50 +0000286openonu-go-adapter-multi-olt-test: ROBOT_MISC_ARGS += -e notreadyOnuGo $(ROBOT_DEBUG_LOG_OPT)
TorstenThiemefe7099e2021-01-29 08:41:04 +0000287openonu-go-adapter-multi-olt-test: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTIPLE_OLT_FILE)
288openonu-go-adapter-multi-olt-test: ROBOT_FILE := Voltha_ONUStateTests.robot
289openonu-go-adapter-multi-olt-test: openonu-go-adapter-tests
TorstenThieme70bc5262021-01-19 12:12:55 +0000290
David Bainbridgef81cd642019-11-20 00:14:47 +0000291sanity-single-kind: ROBOT_MISC_ARGS += -i sanity $(ROBOT_DEBUG_LOG_OPT)
Gilles Depatie45fbe042019-11-11 17:10:06 -0500292sanity-single-kind: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
293sanity-single-kind: bbsim-kind
Hardik Windlass1ed2eee2021-06-25 09:51:03 +0000294
Hardik Windlass9e3db232021-10-14 07:10:47 +0000295sanity-bbsim-att: ROBOT_MISC_ARGS += -v workflow:ATT
Matteo Scandoloa80b4732020-09-04 13:51:10 -0700296sanity-bbsim-att: sanity-bbsim
297
Hardik Windlass9e3db232021-10-14 07:10:47 +0000298sanity-bbsim-dt: ROBOT_MISC_ARGS += -v workflow:DT
Matteo Scandolof310d962021-05-18 10:35:48 -0700299sanity-bbsim-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_SINGLE_PON_FILE)
300sanity-bbsim-dt: ROBOT_FILE := Voltha_BBSimTests.robot
301sanity-bbsim-dt: voltha-bbsim-test
Matteo Scandoloa80b4732020-09-04 13:51:10 -0700302
Hardik Windlass9e3db232021-10-14 07:10:47 +0000303sanity-bbsim-tt: ROBOT_MISC_ARGS += -v workflow:TT
Matteo Scandolof310d962021-05-18 10:35:48 -0700304sanity-bbsim-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_SINGLE_PON_FILE)
305sanity-bbsim-tt: ROBOT_FILE := Voltha_BBSimTests.robot
306sanity-bbsim-tt: voltha-bbsim-test
Matteo Scandoloa80b4732020-09-04 13:51:10 -0700307
308sanity-bbsim: ROBOT_MISC_ARGS += -i bbsimSanity $(ROBOT_DEBUG_LOG_OPT)
309sanity-bbsim: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
310sanity-bbsim: ROBOT_FILE := Voltha_BBSimTests.robot
311sanity-bbsim: voltha-bbsim-test
312
Matteo Scandolo95b22152021-02-05 15:39:34 -0800313voltha-bbsim-test: vst_venv
314 source ./$</bin/activate ; set -u ;\
315 cd tests/bbsim ;\
316 robot -V $(ROBOT_CONFIG_FILE) $(ROBOT_MISC_ARGS) $(ROBOT_FILE)
317
David Bainbridge32c45632020-04-13 08:47:09 -0700318rwcore-restart-single-kind: ROBOT_MISC_ARGS += -X -i functionalANDrwcore-restart $(ROBOT_DEBUG_LOG_OPT)
David Bainbridgef81cd642019-11-20 00:14:47 +0000319rwcore-restart-single-kind: ROBOT_CONFIG_FILE := $(ROBOT_FAIL_SINGLE_PON_FILE)
ubuntu6b6e7d42020-03-02 12:35:42 -0800320rwcore-restart-single-kind: ROBOT_FILE := Voltha_FailureScenarios.robot
David Bainbridgef81cd642019-11-20 00:14:47 +0000321rwcore-restart-single-kind: voltha-test
322
David Bainbridge3d6d5d32019-12-17 19:05:35 +0000323single-kind: ROBOT_MISC_ARGS += -X -i $(TEST_TAGS) $(ROBOT_DEBUG_LOG_OPT)
324single-kind: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
325single-kind: ROBOT_FILE := Voltha_PODTests.robot
326single-kind: voltha-test
327
David Bainbridgef81cd642019-11-20 00:14:47 +0000328sanity-multi-kind: ROBOT_MISC_ARGS += -i sanity $(ROBOT_DEBUG_LOG_OPT)
Gilles Depatie45fbe042019-11-11 17:10:06 -0500329sanity-multi-kind: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULT_PON_FILE)
330sanity-multi-kind: bbsim-kind
Andy Bavierba9866b2019-10-11 07:11:53 -0700331
Andy Bavier8da0e132020-04-13 10:25:16 -0700332functional-multi-kind: ROBOT_MISC_ARGS += -i sanityORfunctional $(ROBOT_DEBUG_LOG_OPT)
333functional-multi-kind: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULT_PON_FILE)
334functional-multi-kind: bbsim-kind
335
Suchitra Vemuri8a9c3782019-10-23 12:43:01 -0700336bbsim-kind: ROBOT_MISC_ARGS += -X
Gilles Depatie45fbe042019-11-11 17:10:06 -0500337bbsim-kind: ROBOT_FILE := Voltha_PODTests.robot
338bbsim-kind: voltha-test
339
David Bainbridgef81cd642019-11-20 00:14:47 +0000340scale-single-kind: ROBOT_MISC_ARGS += -i active $(ROBOT_DEBUG_LOG_OPT)
Gilles Depatie45fbe042019-11-11 17:10:06 -0500341scale-single-kind: ROBOT_CONFIG_FILE := $(ROBOT_SCALE_SINGLE_PON_FILE)
342scale-single-kind: bbsim-scale-kind
343
David Bainbridgef81cd642019-11-20 00:14:47 +0000344scale-multi-kind: ROBOT_MISC_ARGS += -i active $(ROBOT_DEBUG_LOG_OPT)
Gilles Depatie45fbe042019-11-11 17:10:06 -0500345scale-multi-kind: ROBOT_CONFIG_FILE := $(ROBOT_SCALE_MULT_PON_FILE)
346scale-multi-kind: bbsim-scale-kind
347
David Bainbridgef81cd642019-11-20 00:14:47 +0000348bbsim-scale-kind: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT)
Gilles Depatie45fbe042019-11-11 17:10:06 -0500349bbsim-scale-kind: ROBOT_FILE := Voltha_ScaleFunctionalTests.robot
350bbsim-scale-kind: voltha-test
Zack Williamsec53a1b2019-09-16 15:50:52 -0700351
hwchiuab524f02020-02-03 23:24:19 +0000352#Only supported in full mode
353system-scale-test: ROBOT_FILE := K8S_SystemTest.robot
Matteo Scandolo66fe6452021-01-05 13:03:41 -0800354system-scale-test: ROBOT_MISC_ARGS += -X -i functional $(ROBOT_DEBUG_LOG_OPT) -v teardown_device:True
hwchiuab524f02020-02-03 23:24:19 +0000355system-scale-test: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULT_PON_FILE)
356system-scale-test: voltha-test
hwchiu11289122019-11-27 16:20:15 +0000357
hwchiu85695932019-12-18 08:05:25 +0000358failure-test: ROBOT_MISC_ARGS += -X -i FailureTest $(ROBOT_DEBUG_LOG_OPT)
hwchiu3d9a0982020-02-06 00:19:19 +0000359failure-test: ROBOT_FILE := K8S_SystemTest.robot
hwchiu85695932019-12-18 08:05:25 +0000360failure-test: ROBOT_CONFIG_FILE := $(ROBOT_FAIL_SINGLE_PON_FILE)
361failure-test: voltha-test
362
Scott Baker60e570d2020-02-02 22:10:13 -0800363bbsim-alarms-kind: ROBOT_MISC_ARGS += -X -i active
364bbsim-alarms-kind: ROBOT_FILE := Voltha_AlarmTests.robot
Andy Baviere118e052020-03-06 12:49:24 -0700365bbsim-alarms-kind: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
Scott Baker60e570d2020-02-02 22:10:13 -0800366bbsim-alarms-kind: voltctl-docker-image-build voltctl-docker-image-install-kind voltha-test
367
Andy Bavierc1904dc2020-03-20 11:39:15 -0700368bbsim-errorscenarios: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT)
369bbsim-errorscenarios: ROBOT_FILE := Voltha_ErrorScenarios.robot
370bbsim-errorscenarios: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
371bbsim-errorscenarios: voltha-test
372
Hardik Windlass1ed2eee2021-06-25 09:51:03 +0000373bbsim-multiuni-errorscenarios-att: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT)
374bbsim-multiuni-errorscenarios-att: ROBOT_FILE := Voltha_ErrorScenarios.robot
375bbsim-multiuni-errorscenarios-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTI_UNI_SINGLE_PON_FILE)
376bbsim-multiuni-errorscenarios-att: voltha-test
377
Suchitra Vemuri9826c052020-11-18 14:11:51 -0800378bbsim-multiolt-errorscenarios: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT)
379bbsim-multiolt-errorscenarios: ROBOT_FILE := Voltha_ErrorScenarios.robot
380bbsim-multiolt-errorscenarios: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTIPLE_OLT_FILE)
381bbsim-multiolt-errorscenarios: voltha-test
382
Hardik Windlass1ed2eee2021-06-25 09:51:03 +0000383bbsim-multiuni-multiolt-errorscenarios-att: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT)
384bbsim-multiuni-multiolt-errorscenarios-att: ROBOT_FILE := Voltha_ErrorScenarios.robot
385bbsim-multiuni-multiolt-errorscenarios-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTI_UNI_MULTIPLE_OLT_FILE)
386bbsim-multiuni-multiolt-errorscenarios-att: voltha-test
387
Hardik Windlasscbcca312020-04-20 21:46:11 +0530388bbsim-errorscenarios-dt: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT)
389bbsim-errorscenarios-dt: ROBOT_FILE := Voltha_ErrorScenarios.robot
390bbsim-errorscenarios-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_SINGLE_PON_FILE)
391bbsim-errorscenarios-dt: voltha-test
392
Hardik Windlasse05e4712020-04-29 10:40:42 +0530393bbsim-failurescenarios: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT) -e PowerSwitch -e PhysicalOLTReboot
Andy Bavier8da0e132020-04-13 10:25:16 -0700394bbsim-failurescenarios: ROBOT_FILE := Voltha_FailureScenarios.robot
395bbsim-failurescenarios: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
396bbsim-failurescenarios: voltha-test
397
Hardik Windlass1ed2eee2021-06-25 09:51:03 +0000398bbsim-multiuni-failurescenarios-att: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT) -e PowerSwitch -e PhysicalOLTReboot
399bbsim-multiuni-failurescenarios-att: ROBOT_FILE := Voltha_FailureScenarios.robot
400bbsim-multiuni-failurescenarios-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTI_UNI_SINGLE_PON_FILE)
401bbsim-multiuni-failurescenarios-att: voltha-test
402
Suchitra Vemuri9826c052020-11-18 14:11:51 -0800403bbsim-multiolt-failurescenarios: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT) -e PowerSwitch -e PhysicalOLTReboot
404bbsim-multiolt-failurescenarios: ROBOT_FILE := Voltha_FailureScenarios.robot
405bbsim-multiolt-failurescenarios: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTIPLE_OLT_FILE)
406bbsim-multiolt-failurescenarios: voltha-test
407
Hardik Windlass1ed2eee2021-06-25 09:51:03 +0000408bbsim-multiuni-multiolt-failurescenarios-att: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT) -e PowerSwitch -e PhysicalOLTReboot
409bbsim-multiuni-multiolt-failurescenarios-att: ROBOT_FILE := Voltha_FailureScenarios.robot
410bbsim-multiuni-multiolt-failurescenarios-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTI_UNI_MULTIPLE_OLT_FILE)
411bbsim-multiuni-multiolt-failurescenarios-att: voltha-test
412
Hardik Windlass5ceb84e2021-02-11 11:17:08 +0000413bbsim-multiolt-kind: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT) -e PowerSwitch -e MultiOLTPhysicalReboot
Suchitra Vemuri6971c392020-12-08 10:41:33 -0800414bbsim-multiolt-kind: ROBOT_FILE := Voltha_MultiOLT_Tests.robot
415bbsim-multiolt-kind: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTIPLE_OLT_FILE)
416bbsim-multiolt-kind: voltha-test
417
Hardik Windlass5ceb84e2021-02-11 11:17:08 +0000418bbsim-multiolt-kind-dt: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT) -e PowerSwitch -e MultiOLTPhysicalRebootDt
Suchitra Vemuri6971c392020-12-08 10:41:33 -0800419bbsim-multiolt-kind-dt: ROBOT_FILE := Voltha_DT_MultiOLT_Tests.robot
420bbsim-multiolt-kind-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTIPLE_OLT_FILE)
421bbsim-multiolt-kind-dt: voltha-dt-test
422
423multiolt-kind-dt: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT) -i functionalDt
424multiolt-kind-dt: ROBOT_FILE := Voltha_DT_MultiOLT_Tests.robot
425multiolt-kind-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTIPLE_OLT_FILE)
426multiolt-kind-dt: voltha-dt-test
427
Hardik Windlass9df139e2020-04-24 14:54:54 +0530428bbsim-failurescenarios-dt: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT) -e PowerSwitchOnuRebootDt -e PhysicalOltRebootDt
429bbsim-failurescenarios-dt: ROBOT_FILE := Voltha_DT_FailureScenarios.robot
430bbsim-failurescenarios-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_SINGLE_PON_FILE)
431bbsim-failurescenarios-dt: voltha-dt-test
432
Hardik Windlassb1bda362021-11-24 11:54:36 +0000433bbsim-failurescenarios-tt: ROBOT_MISC_ARGS += -X $(ROBOT_DEBUG_LOG_OPT) -e PowerSwitch -e PhysicalOltRebootTT -e dataplaneTT
TorstenThieme136ebf72021-02-26 14:27:07 +0000434bbsim-failurescenarios-tt: ROBOT_FILE := Voltha_TT_FailureScenarios.robot
435bbsim-failurescenarios-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_SINGLE_PON_FILE)
436bbsim-failurescenarios-tt: voltha-tt-test
437
Andrea Campanellaf1081572021-10-06 16:06:55 +0200438onos-ha-test: ROBOT_MISC_ARGS += -e notready -X $(ROBOT_DEBUG_LOG_OPT)
439onos-ha-test: ROBOT_FILE := Voltha_ONOSHATests.robot
440onos-ha-test: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
441onos-ha-test: voltha-test
442
Matteo Scandoloab48f9e2021-06-11 17:08:00 +0200443voltha-test: ROBOT_MISC_ARGS += -e notready --noncritical non-critical
hwchiu11289122019-11-27 16:20:15 +0000444
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700445voltha-test: vst_venv
446 source ./$</bin/activate ; set -u ;\
447 cd tests/functional ;\
448 robot -V $(ROBOT_CONFIG_FILE) $(ROBOT_MISC_ARGS) $(ROBOT_FILE)
449
TorstenThiemef8f9a802020-12-16 15:25:25 +0000450bbsim-dmi-hw-management-test: ROBOT_MISC_ARGS += -e notreadyDMI -i functionalDMI -e bbsimUnimplementedDMI
451bbsim-dmi-hw-management-test: ROBOT_FILE := dmi-hw-management.robot
452bbsim-dmi-hw-management-test: ROBOT_CONFIG_FILE := $(ROBOT_DMI_SINGLE_BBSIM_FILE)
453bbsim-dmi-hw-management-test: voltha-dmi-test
uwe ottrembka504ca3e2020-11-23 12:02:20 +0100454
TorstenThiemef8f9a802020-12-16 15:25:25 +0000455voltha-dmi-hw-management-test: ROBOT_MISC_ARGS += -e notreadyDMI -i functionalDMI
456voltha-dmi-hw-management-test: ROBOT_FILE := dmi-hw-management.robot
457voltha-dmi-hw-management-test: ROBOT_CONFIG_FILE := $(ROBOT_DMI_SINGLE_ADTRAN_FILE)
458voltha-dmi-hw-management-test: voltha-dmi-test
459
460voltha-dmi-test: vst_venv
uwe ottrembka504ca3e2020-11-23 12:02:20 +0100461 source ./$</bin/activate ; set -u ;\
462 cd tests/dmi-interface ;\
463 robot -V $(ROBOT_CONFIG_FILE) $(ROBOT_MISC_ARGS) $(ROBOT_FILE)
464
TorstenThiemeff9c9142021-04-08 07:21:34 +0000465# target to invoke single ONU pm data scenarios in ATT workflow
Hardik Windlass9e3db232021-10-14 07:10:47 +0000466voltha-pm-data-single-kind-att: ROBOT_MISC_ARGS += -v workflow:ATT
TorstenThiemeff9c9142021-04-08 07:21:34 +0000467voltha-pm-data-single-kind-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
468voltha-pm-data-single-kind-att: voltha-pm-data-tests
469
470# target to invoke single ONU pm data scenarios in DT workflow
Hardik Windlass9e3db232021-10-14 07:10:47 +0000471voltha-pm-data-single-kind-dt: ROBOT_MISC_ARGS += -v workflow:DT
TorstenThiemeff9c9142021-04-08 07:21:34 +0000472voltha-pm-data-single-kind-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_SINGLE_PON_FILE)
473voltha-pm-data-single-kind-dt: voltha-pm-data-tests
474
475# target to invoke single ONU pm data scenarios in TT workflow
Hardik Windlass9e3db232021-10-14 07:10:47 +0000476voltha-pm-data-single-kind-tt: ROBOT_MISC_ARGS += -v workflow:TT
TorstenThieme90a99f82021-05-05 09:17:37 +0000477voltha-pm-data-single-kind-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_SINGLE_PON_FILE)
478voltha-pm-data-single-kind-tt: voltha-pm-data-tests
TorstenThiemeff9c9142021-04-08 07:21:34 +0000479
480# target to invoke multiple OLTs pm data scenarios in ATT workflow
Hardik Windlass9e3db232021-10-14 07:10:47 +0000481voltha-pm-data-multiolt-kind-att: ROBOT_MISC_ARGS += -v workflow:ATT
TorstenThiemeff9c9142021-04-08 07:21:34 +0000482voltha-pm-data-multiolt-kind-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTIPLE_OLT_FILE)
483voltha-pm-data-multiolt-kind-att: voltha-pm-data-tests
484
485# target to invoke multiple OLTs pm data scenarios in DT workflow
Hardik Windlass9e3db232021-10-14 07:10:47 +0000486voltha-pm-data-multiolt-kind-dt: ROBOT_MISC_ARGS += -v workflow:DT
TorstenThiemeff9c9142021-04-08 07:21:34 +0000487voltha-pm-data-multiolt-kind-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_MULTIPLE_OLT_FILE)
488voltha-pm-data-multiolt-kind-dt: voltha-pm-data-tests
489
490# target to invoke multiple OLTs pm data scenarios in TT workflow
Hardik Windlass9e3db232021-10-14 07:10:47 +0000491voltha-pm-data-multiolt-kind-tt: ROBOT_MISC_ARGS += -v workflow:TT
TorstenThiemeff9c9142021-04-08 07:21:34 +0000492voltha-pm-data-multiolt-kind-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_MULTIPLE_OLT_FILE)
493voltha-pm-data-multiolt-kind-tt: voltha-pm-data-tests
494
495voltha-pm-data-tests: ROBOT_MISC_ARGS += -i functional -e PowerSwitch $(ROBOT_DEBUG_LOG_OPT)
496voltha-pm-data-tests: ROBOT_PM_CONFIG_FILE := $(ROBOT_PM_DATA_FILE)
497voltha-pm-data-tests: ROBOT_FILE := Voltha_ONUPMTests.robot
498voltha-pm-data-tests: voltha-pm-data-test
499
500voltha-pm-data-test: vst_venv
501 source ./$</bin/activate ; set -u ;\
502 cd tests/pm-data ;\
503 robot -V $(ROBOT_CONFIG_FILE) -V $(ROBOT_PM_CONFIG_FILE) $(ROBOT_MISC_ARGS) $(ROBOT_FILE)
504
TorstenThieme1c1f5fa2021-06-18 13:40:30 +0000505# target to invoke single ONU OMCI Get scenarios in ATT workflow
506voltha-onu-omci-get-single-kind-att: ROBOT_MISC_ARGS += -v workflow:ATT
507voltha-onu-omci-get-single-kind-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
508voltha-onu-omci-get-single-kind-att: voltha-onu-omci-get-tests
509
510# target to invoke single ONU OMCI Get scenarios in DT workflow
511voltha-onu-omci-get-single-kind-dt: ROBOT_MISC_ARGS += -v workflow:DT
512voltha-onu-omci-get-single-kind-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_SINGLE_PON_FILE)
513voltha-onu-omci-get-single-kind-dt: voltha-onu-omci-get-tests
514
TorstenThiemea7315f12021-07-23 11:56:34 +0000515# target to invoke single ONU OMCI Get scenarios in TT workflow
TorstenThieme1c1f5fa2021-06-18 13:40:30 +0000516voltha-onu-omci-get-single-kind-tt: ROBOT_MISC_ARGS += -v workflow:TT
517voltha-onu-omci-get-single-kind-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_SINGLE_PON_FILE)
518voltha-onu-omci-get-single-kind-tt: voltha-onu-omci-get-tests
519
520# target to invoke multiple OLTs OMCI Get scenarios in ATT workflow
521voltha-onu-omci-get-multiolt-kind-att: ROBOT_MISC_ARGS += -v workflow:ATT
522voltha-onu-omci-get-multiolt-kind-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTIPLE_OLT_FILE)
523voltha-onu-omci-get-multiolt-kind-att: voltha-onu-omci-get-tests
524
525# target to invoke multiple OLTs OMCI Get scenarios in DT workflow
526voltha-onu-omci-get-multiolt-kind-dt: ROBOT_MISC_ARGS += -v workflow:DT
527voltha-onu-omci-get-multiolt-kind-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_MULTIPLE_OLT_FILE)
528voltha-onu-omci-get-multiolt-kind-dt: voltha-onu-omci-get-tests
529
530# target to invoke multiple OLTs OMCI Get scenarios in TT workflow
531voltha-onu-omci-get-multiolt-kind-tt: ROBOT_MISC_ARGS += -v workflow:TT
532voltha-onu-omci-get-multiolt-kind-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_MULTIPLE_OLT_FILE)
533voltha-onu-omci-get-multiolt-kind-tt: voltha-onu-omci-get-tests
534
535voltha-onu-omci-get-tests: ROBOT_MISC_ARGS += -i functionalOnuGo -e PowerSwitch $(ROBOT_DEBUG_LOG_OPT)
536voltha-onu-omci-get-tests: ROBOT_FILE := Voltha_ONUOmciGetTest.robot
537voltha-onu-omci-get-tests: openonu-go-adapter-tests
538
TorstenThiemea7315f12021-07-23 11:56:34 +0000539# target to invoke single ONU Flows Check in ATT workflow
540voltha-onu-flows-check-single-kind-att: ROBOT_MISC_ARGS += -v workflow:ATT
541voltha-onu-flows-check-single-kind-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
542voltha-onu-flows-check-single-kind-att: voltha-onu-flows-check-tests
543
544# target to invoke single ONU Flows Check scenarios in DT workflow
545voltha-onu-flows-check-single-kind-dt: ROBOT_MISC_ARGS += -v workflow:DT -v techprofile:1T8GEM
546voltha-onu-flows-check-single-kind-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_SINGLE_PON_FILE)
547voltha-onu-flows-check-single-kind-dt: voltha-onu-flows-check-tests
548
549# target to invoke single ONU Flows Check scenarios in TT workflow
550voltha-onu-flows-check-single-kind-tt: ROBOT_MISC_ARGS += -v workflow:TT -v techprofile:1T4GEM
551voltha-onu-flows-check-single-kind-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_SINGLE_PON_FILE)
552voltha-onu-flows-check-single-kind-tt: voltha-onu-flows-check-tests
553
554# target to invoke multiple OLTs Flows Check scenarios in ATT workflow
555voltha-onu-flows-check-multiolt-kind-att: ROBOT_MISC_ARGS += -v workflow:ATT
556voltha-onu-flows-check-multiolt-kind-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTIPLE_OLT_FILE)
557voltha-onu-flows-check-multiolt-kind-att: voltha-onu-flows-check-tests
558
559# target to invoke multiple OLTs Flows Check scenarios in DT workflow
560voltha-onu-flows-check-multiolt-kind-dt: ROBOT_MISC_ARGS += -v workflow:DT -v techprofile:1T8GEM
561voltha-onu-flows-check-multiolt-kind-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_MULTIPLE_OLT_FILE)
562voltha-onu-flows-check-multiolt-kind-dt: voltha-onu-flows-check-tests
563
564# target to invoke multiple OLTs Flows Check scenarios in TT workflow
565voltha-onu-flows-check-multiolt-kind-tt: ROBOT_MISC_ARGS += -v workflow:TT -v techprofile:1T4GEM
566voltha-onu-flows-check-multiolt-kind-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_MULTIPLE_OLT_FILE)
567voltha-onu-flows-check-multiolt-kind-tt: voltha-onu-flows-check-tests
568
569voltha-onu-flows-check-tests: ROBOT_MISC_ARGS += -i functionalOnuGo -e PowerSwitch $(ROBOT_DEBUG_LOG_OPT)
570voltha-onu-flows-check-tests: ROBOT_FILE := Voltha_ONUFlowChecks.robot
571voltha-onu-flows-check-tests: openonu-go-adapter-tests
572
Hardik Windlassdd1a9a12021-02-23 15:34:50 +0000573# ONOS Apps to test for Software Upgrade need to be passed in the 'onos_apps_under_test' variable in format:
Hardik Windlassdc2610f2021-03-09 07:33:51 +0000574# <app-name>,<version>,<oar-url>*<app-name>,<version>,<oar-url>*
Hardik Windlassdd1a9a12021-02-23 15:34:50 +0000575onos-app-upgrade-test: ROBOT_MISC_ARGS += -e notready -i functional
576onos-app-upgrade-test: ROBOT_FILE := ONOS_AppsUpgrade.robot
Hardik Windlass17bd1142021-03-12 08:15:25 +0000577onos-app-upgrade-test: ROBOT_CONFIG_FILE := $(ROBOT_SW_UPGRADE_FILE)
Hardik Windlassdd1a9a12021-02-23 15:34:50 +0000578onos-app-upgrade-test: software-upgrade-test
579
580# Voltha Components to test for Software Upgrade need to be passed in the 'voltha_comps_under_test' variable in format:
Hardik Windlassdc2610f2021-03-09 07:33:51 +0000581# <comp-label>,<comp-container>,<comp-image>*<comp-label>,<comp-container>,<comp-image>*
Hardik Windlass76f68212022-01-19 08:16:14 +0000582voltha-comp-upgrade-test: ROBOT_MISC_ARGS += -e notready -i VolthaCompMinorVerUpgrade
Hardik Windlassdd1a9a12021-02-23 15:34:50 +0000583voltha-comp-upgrade-test: ROBOT_FILE := Voltha_ComponentsUpgrade.robot
Hardik Windlass17bd1142021-03-12 08:15:25 +0000584voltha-comp-upgrade-test: ROBOT_CONFIG_FILE := $(ROBOT_SW_UPGRADE_FILE)
Hardik Windlassdd1a9a12021-02-23 15:34:50 +0000585voltha-comp-upgrade-test: software-upgrade-test
586
Hardik Windlass76f68212022-01-19 08:16:14 +0000587# Voltha Components to test for Software Upgrade need to be passed in the 'voltha_comps_under_test' variable in format:
588# <comp-label>,<comp-container>,<comp-image>*<comp-label>,<comp-container>,<comp-image>*
589voltha-comp-rolling-upgrade-test: ROBOT_MISC_ARGS += -e notready -i VolthaCompMinorVerRollingUpgrade
590voltha-comp-rolling-upgrade-test: ROBOT_FILE := Voltha_ComponentsUpgrade.robot
591voltha-comp-rolling-upgrade-test: ROBOT_CONFIG_FILE := $(ROBOT_SW_UPGRADE_FILE)
592voltha-comp-rolling-upgrade-test: software-upgrade-test
593
Hardik Windlass17bd1142021-03-12 08:15:25 +0000594# Requirement: Pass ONU image details in following parameters
Hardik Windlassba1bd272021-06-22 08:29:33 +0000595# image_version, image_url, image_vendor, image_activate_on_success, image_commit_on_success, image_crc
Hardik Windlass17bd1142021-03-12 08:15:25 +0000596onu-upgrade-test: ROBOT_MISC_ARGS += -e notready -i functional
597onu-upgrade-test: ROBOT_FILE := ONU_Upgrade.robot
598onu-upgrade-test: ROBOT_CONFIG_FILE := $(ROBOT_SW_UPGRADE_FILE)
599onu-upgrade-test: software-upgrade-test
600
TorstenThiemef3e492c2021-11-08 15:25:48 +0000601# Requirement: Pass ONU image details in following parameters
602# image_version, image_url, image_vendor, image_activate_on_success, image_commit_on_success, image_crc
603onu-upgrade-test-multiolt-kind-att: ROBOT_MISC_ARGS += -e notready -i functionalMultipleONUs
604onu-upgrade-test-multiolt-kind-att: ROBOT_FILE := ONU_Upgrade.robot
605onu-upgrade-test-multiolt-kind-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTIPLE_OLT_FILE)
606onu-upgrade-test-multiolt-kind-att: software-upgrade-test
607
TorstenThieme0c8cc6f2022-02-16 13:48:21 +0000608# Voltha openonu MIB Audit tests att workflow single kind
609onu-mib-audit-test-single-kind-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
610onu-mib-audit-test-single-kind-att: voltha-onu-mib-audit-tests
611
612# Voltha openonu MIB Audit tests t workflow single kind
613onu-mib-audit-test-single-kind-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_SINGLE_PON_FILE)
614onu-mib-audit-test-single-kind-dt: voltha-onu-mib-audit-tests
615
616# Voltha openonu MIB Audit tests tt workflow single kind
617onu-mib-audit-test-single-kind-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_SINGLE_PON_FILE)
618onu-mib-audit-test-single-kind-tt: voltha-onu-mib-audit-tests
619
620# Voltha openonu MIB Audit tests att workflow multiple OLTs
621onu-mib-audit-test-multiolt-kind-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTIPLE_OLT_FILE)
622onu-mib-audit-test-multiolt-kind-att: voltha-onu-mib-audit-tests
623
624# Voltha openonu MIB Audit tests tt workflow multiple OLTs
625onu-mib-audit-test-multiolt-kind-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_MULTIPLE_OLT_FILE)
626onu-mib-audit-test-multiolt-kind-dt: voltha-onu-mib-audit-tests
627
628# Voltha openonu MIB Audit tests tt workflow multiple OLTs
629onu-mib-audit-test-multiolt-kind-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_MULTIPLE_OLT_FILE)
630onu-mib-audit-test-multiolt-kind-tt: voltha-onu-mib-audit-tests
631
632voltha-onu-mib-audit-tests: ROBOT_MISC_ARGS += -i functional -e notready --noncritical non-critical
633voltha-onu-mib-audit-tests: ROBOT_MISC_ARGS += $(ROBOT_DEBUG_LOG_OPT)
634voltha-onu-mib-audit-tests: ROBOT_FILE := Voltha_ONUMibAudit.robot
635voltha-onu-mib-audit-tests: openonu-go-adapter-tests
636
TorstenThieme700ccbf2022-02-11 10:24:05 +0000637# Voltha Components Memory Leak tests att workflow single kind
638memory-leak-test-single-kind-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_SINGLE_PON_FILE)
639memory-leak-test-single-kind-att: voltha-memory-leak-tests
640
641# Voltha Components Memory Leak tests t workflow single kind
642memory-leak-test-single-kind-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_SINGLE_PON_FILE)
643memory-leak-test-single-kind-dt: voltha-memory-leak-tests
644
645# Voltha Components Memory Leak tests tt workflow single kind
646memory-leak-test-single-kind-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_SINGLE_PON_FILE)
647memory-leak-test-single-kind-tt: voltha-memory-leak-tests
648
649# Voltha Components Memory Leak tests att workflow multiple OLTs
650memory-leak-test-multiolt-kind-att: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_MULTIPLE_OLT_FILE)
651memory-leak-test-multiolt-kind-att: voltha-memory-leak-tests
652
653# Voltha Components Memory Leak tests tt workflow multiple OLTs
654memory-leak-test-multiolt-kind-dt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_DT_MULTIPLE_OLT_FILE)
655memory-leak-test-multiolt-kind-dt: voltha-memory-leak-tests
656
657# Voltha Components Memory Leak tests tt workflow multiple OLTs
658memory-leak-test-multiolt-kind-tt: ROBOT_CONFIG_FILE := $(ROBOT_SANITY_TT_MULTIPLE_OLT_FILE)
659memory-leak-test-multiolt-kind-tt: voltha-memory-leak-tests
660
661voltha-memory-leak-tests: ROBOT_MISC_ARGS += -i functionalMemoryLeak -e notready --noncritical non-critical
662voltha-memory-leak-tests: ROBOT_MISC_ARGS += $(ROBOT_DEBUG_LOG_OPT)
663voltha-memory-leak-tests: ROBOT_FILE := VOLTHA_Memory_Leak_Tests.robot
664voltha-memory-leak-tests: voltha-memory-leak-test
665
Hardik Windlassdd1a9a12021-02-23 15:34:50 +0000666software-upgrade-test: vst_venv
667 source ./$</bin/activate ; set -u ;\
668 cd tests/software-upgrades ;\
669 robot -V $(ROBOT_CONFIG_FILE) $(ROBOT_MISC_ARGS) $(ROBOT_FILE)
670
Matteo Scandoloab48f9e2021-06-11 17:08:00 +0200671voltha-dt-test: ROBOT_MISC_ARGS += -e notready --noncritical non-critical
Hardik Windlass79b40ff2020-06-11 22:55:47 +0530672
Hardik Windlassa3d04b92020-02-17 15:06:05 +0000673voltha-dt-test: vst_venv
674 source ./$</bin/activate ; set -u ;\
675 cd tests/dt-workflow ;\
676 robot -V $(ROBOT_CONFIG_FILE) $(ROBOT_MISC_ARGS) $(ROBOT_FILE)
677
Emrehan UZUNd6f85892021-07-01 13:54:26 +0000678voltha-tt-test: ROBOT_MISC_ARGS += -e notready --noncritical non-critical
Hardik Windlass43118692020-07-01 22:16:47 +0530679
680voltha-tt-test: vst_venv
681 source ./$</bin/activate ; set -u ;\
682 cd tests/tt-workflow ;\
683 robot -V $(ROBOT_CONFIG_FILE) $(ROBOT_MISC_ARGS) $(ROBOT_FILE)
684
Andrea Speranzaa8cf80b2022-05-26 10:09:59 +0200685voltha-tim-test: ROBOT_MISC_ARGS += -e notready --noncritical non-critical
686
687voltha-tim-test: vst_venv
688 source ./$</bin/activate ; set -u ;\
689 cd tests/tim-workflow ;\
690 robot -V $(ROBOT_CONFIG_FILE) $(ROBOT_MISC_ARGS) $(ROBOT_FILE)
691
Matteo Scandolo142e6272020-04-29 17:36:59 -0700692voltha-scale-test: vst_venv
693 source ./$</bin/activate ; set -u ;\
694 cd tests/scale ;\
695 robot $(ROBOT_MISC_ARGS) Voltha_Scale_Tests.robot
696
TorstenThieme89caa142020-10-05 08:20:31 +0000697openonu-go-adapter-tests: vst_venv
TorstenThieme1619db22020-04-03 12:01:15 +0000698 source ./$</bin/activate ; set -u ;\
699 cd tests/openonu-go-adapter ;\
700 robot -V $(ROBOT_CONFIG_FILE) $(ROBOT_MISC_ARGS) $(ROBOT_FILE)
701
TorstenThieme700ccbf2022-02-11 10:24:05 +0000702voltha-memory-leak-test: vst_venv
703 source ./$</bin/activate ; set -u ;\
704 cd tests/memory-leak ;\
705 robot -V $(ROBOT_CONFIG_FILE) $(ROBOT_MISC_ARGS) $(ROBOT_FILE)
TorstenThieme1619db22020-04-03 12:01:15 +0000706
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700707# self-test, lint, and setup targets
708
709# virtualenv for the robot tools
Andy Bavier952b95b2020-03-06 09:53:42 -0700710# VOL-2724 Invoke pip via python3 to avoid pathname too long on QA jobs
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700711vst_venv:
712 virtualenv -p python3 $@ ;\
713 source ./$@/bin/activate ;\
Andy Baviere118e052020-03-06 12:49:24 -0700714 python -m pip install -r requirements.txt
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700715
716test: lint
717
718lint: lint-robot lint-python lint-yaml lint-json
719
720lint-robot: vst_venv
721 source ./$</bin/activate ; set -u ;\
722 rflint $(LINT_ARGS) $(ROBOT_FILES)
723
724# check deps for format and python3 cleanliness
725lint-python: vst_venv
726 source ./$</bin/activate ; set -u ;\
727 pylint --py3k $(PYTHON_FILES) ;\
728 flake8 --max-line-length=99 --count $(PYTHON_FILES)
729
730lint-yaml: vst_venv
731 source ./$</bin/activate ; set -u ;\
732 yamllint -s $(YAML_FILES)
733
734lint-json: vst_venv
735 source ./$</bin/activate ; set -u ;\
736 for jsonfile in $(JSON_FILES); do \
737 echo "Validating json file: $$jsonfile" ;\
738 python -m json.tool $$jsonfile > /dev/null ;\
739 done
740
741# tidy target will be more useful once issue with removing leading comments
742# is resolved: https://github.com/robotframework/robotframework/issues/3263
743tidy-robot: vst_venv
744 source ./$</bin/activate ; set -u ;\
745 python -m robot.tidy --inplace $(ROBOT_FILES);
746
Andy Bavier4a8450e2020-02-04 08:58:37 -0700747# Install the 'kail' tool if needed: https://github.com/boz/kail
748KAIL_PATH ?= /usr/local/bin
749$(KAIL_PATH)/kail:
750 bash <( curl -sfL https://raw.githubusercontent.com/boz/kail/master/godownloader.sh) -b /tmp
751 mv /tmp/kail $(KAIL_PATH)
752
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700753## Variables for gendocs
754TEST_SOURCE := $(wildcard tests/*/*.robot)
755TEST_BASENAME := $(basename $(TEST_SOURCE))
756TEST_DIRS := $(dir $(TEST_SOURCE))
757
758LIB_SOURCE := $(wildcard libraries/*.robot)
759LIB_BASENAME := $(basename $(LIB_SOURCE))
760LIB_DIRS := $(dir $(LIB_SOURCE))
761
762.PHONY: gendocs lint test
763# In future explore use of --docformat REST - integration w/Sphinx?
Zack Williamsec53a1b2019-09-16 15:50:52 -0700764gendocs: vst_venv
Zack Williamsa8fe75a2020-01-10 14:25:27 -0700765 source ./$</bin/activate ; set -u ;\
hwchiu0601ec72019-10-08 00:04:43 +0000766 mkdir -p $@ ;\
767 for dir in ${LIB_DIRS}; do mkdir -p $@/$$dir; done;\
768 for dir in ${LIB_BASENAME}; do\
769 python -m robot.libdoc --format HTML $$dir.robot $@/$$dir.html ;\
770 done ;\
771 for dir in ${TEST_DIRS}; do mkdir -p $@/$$dir; done;\
772 for dir in ${TEST_BASENAME}; do\
773 python -m robot.testdoc $$dir.robot $@/$$dir.html ;\
774 done
Zack Williamsec53a1b2019-09-16 15:50:52 -0700775
Zack Williamsec53a1b2019-09-16 15:50:52 -0700776clean:
777 find . -name output.xml -print
778
779clean-all: clean
780 rm -rf vst_venv gendocs
Scott Baker60e570d2020-02-02 22:10:13 -0800781
782voltctl-docker-image-build:
783 cd docker && docker build -t opencord/voltctl:local -f Dockerfile.voltctl .
784
785voltctl-docker-image-install-kind:
Matteo Scandolo10acf562021-05-03 15:35:16 -0700786 @if [ "`kind get clusters | grep kind`" = '' ]; then echo "no kind cluster found" && exit 1; fi
787 kind load docker-image --name `kind get clusters | grep kind` opencord/voltctl:local