| # Copyright 2018 the original author or authors. |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| from voltha.protos.events_pb2 import AlarmEventType, AlarmEventSeverity, AlarmEventCategory |
| from voltha.extensions.alarms.adapter_alarms import AlarmBase |
| |
| |
| class OnuSelfTestFailureAlarm(AlarmBase): |
| """ |
| The ONU Self Test Failure Alarm is reported by both the CircuitPack (ME #6) |
| and the ONT-G (ME # 256) to indicate failure a failed autonomous self-test. |
| |
| For CircuitPack equipment alarms, the intf_id reported is that of the |
| UNI's logical port number |
| |
| For ONT-G equipment alarms, the intf_id reported is that of the PON/ANI |
| physical port number |
| |
| Note: Some ONUs may use this alarm to report a self-test failure or may |
| may report it with the ONU Equipment Alarm which can also cover a |
| self-test failure. |
| """ |
| def __init__(self, alarm_mgr, onu_id, intf_id): |
| super(OnuSelfTestFailureAlarm, self).__init__(alarm_mgr, object_type='onu self-test failure', |
| alarm='ONU_SELF_TEST_FAIL', |
| alarm_category=AlarmEventCategory.ONU, |
| alarm_type=AlarmEventType.EQUIPTMENT, |
| alarm_severity=AlarmEventSeverity.CRITICAL) |
| self._onu_id = onu_id |
| self._intf_id = intf_id |
| |
| def get_context_data(self): |
| return {'onu-id': self._onu_id, |
| 'onu-intf-id': self._intf_id} |