| # |
| # Copyright 2017 the original author or authors. |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| # |
| import inspect |
| |
| import sys |
| from binascii import hexlify |
| from bitstring import BitArray |
| import json |
| from scapy.fields import ByteField, ShortField, MACField, BitField, IPField |
| from scapy.fields import IntField, StrFixedLenField, LongField, FieldListField |
| from scapy.packet import Packet |
| |
| from voltha.extensions.omci.omci_defs import OmciUninitializedFieldError, \ |
| AttributeAccess, OmciNullPointer, EntityOperations, OmciInvalidTypeError |
| from voltha.extensions.omci.omci_fields import OmciSerialNumberField |
| from voltha.extensions.omci.omci_defs import bitpos_from_mask |
| |
| class EntityClassAttribute(object): |
| |
| def __init__(self, fld, access=set(), optional=False, range_check=None, |
| avc=False, tca=False, counter=False, deprecated=False): |
| """ |
| Initialize an Attribute for a Managed Entity Class |
| |
| :param fld: (Field) Scapy field type |
| :param access: (AttributeAccess) Allowed access |
| :param optional: (boolean) If true, attribute is option, else mandatory |
| :param range_check: (callable) None, Lambda, or Function to validate value |
| :param avc: (boolean) If true, an AVC notification can occur for the attribute |
| :param tca: (boolean) If true, a threshold crossing alert alarm notification can occur |
| for the attribute |
| :param counter: (boolean) If true, this attribute is a PM counter |
| :param deprecated: (boolean) If true, this attribute is deprecated and |
| only 'read' operations (if-any) performed. |
| """ |
| self._fld = fld |
| self._access = access |
| self._optional = optional |
| self._range_check = range_check |
| self._avc = avc |
| self._tca = tca |
| self._counter = counter |
| self._deprecated = deprecated |
| |
| @property |
| def field(self): |
| return self._fld |
| |
| @property |
| def access(self): |
| return self._access |
| |
| @property |
| def optional(self): |
| return self._optional |
| |
| @property |
| def is_counter(self): |
| return self._counter |
| |
| @property |
| def range_check(self): |
| return self._range_check |
| |
| @property |
| def avc_allowed(self): |
| return self._avc |
| |
| @property |
| def deprecated(self): |
| return self._deprecated |
| |
| _type_checker_map = { |
| 'ByteField': lambda val: isinstance(val, (int, long)) and 0 <= val <= 0xFF, |
| 'ShortField': lambda val: isinstance(val, (int, long)) and 0 <= val <= 0xFFFF, |
| 'IntField': lambda val: isinstance(val, (int, long)) and 0 <= val <= 0xFFFFFFFF, |
| 'LongField': lambda val: isinstance(val, (int, long)) and 0 <= val <= 0xFFFFFFFFFFFFFFFF, |
| 'StrFixedLenField': lambda val: isinstance(val, basestring), |
| 'MACField': lambda val: True, # TODO: Add a constraint for this field type |
| 'BitField': lambda val: True, # TODO: Add a constraint for this field type |
| 'IPField': lambda val: True, # TODO: Add a constraint for this field type |
| |
| # TODO: As additional Scapy field types are used, add constraints |
| } |
| |
| def valid(self, value): |
| def _isa_lambda_function(v): |
| import inspect |
| return callable(v) and len(inspect.getargspec(v).args) == 1 |
| |
| field_type = self.field.__class__.__name__ |
| type_check = EntityClassAttribute._type_checker_map.get(field_type, |
| lambda val: True) |
| |
| # TODO: Currently StrFixedLenField is used heavily for both bit fields as |
| # and other 'byte/octet' related strings that are NOT textual. Until |
| # all of these are corrected, 'StrFixedLenField' cannot test the type |
| # of the value provided |
| |
| if field_type != 'StrFixedLenField' and not type_check(value): |
| return False |
| |
| if _isa_lambda_function(self.range_check): |
| return self.range_check(value) |
| return True |
| |
| |
| class EntityClassMeta(type): |
| """ |
| Metaclass for EntityClass to generate secondary class attributes |
| for class attributes of the derived classes. |
| """ |
| def __init__(cls, name, bases, dct): |
| super(EntityClassMeta, cls).__init__(name, bases, dct) |
| |
| # initialize attribute_name_to_index_map |
| cls.attribute_name_to_index_map = dict( |
| (a._fld.name, idx) for idx, a in enumerate(cls.attributes)) |
| |
| |
| class EntityClass(object): |
| |
| class_id = 'to be filled by subclass' |
| attributes = [] |
| mandatory_operations = set() |
| optional_operations = set() |
| notifications = set() |
| alarms = dict() # Alarm Number -> Alarm Name |
| hidden = False # If true, this attribute is not reported by a MIB upload. |
| # This attribute is needed to be able to properly perform |
| # MIB Audits. |
| |
| # will be map of attr_name -> index in attributes, initialized by metaclass |
| attribute_name_to_index_map = None |
| __metaclass__ = EntityClassMeta |
| |
| def __init__(self, **kw): |
| assert(isinstance(kw, dict)) |
| for k, v in kw.iteritems(): |
| assert(k in self.attribute_name_to_index_map) |
| self._data = kw |
| |
| def serialize(self, mask=None, operation=None): |
| octets = '' |
| |
| # generate ordered list of attribute indices needed to be processed |
| # if mask is provided, we use that explicitly |
| # if mask is not provided, we determine attributes from the self._data |
| # content also taking into account the type of operation in hand |
| if mask is not None: |
| attribute_indices = EntityClass.attribute_indices_from_mask(mask) |
| else: |
| attribute_indices = self.attribute_indices_from_data() |
| |
| # Serialize each indexed field (ignoring entity id) |
| for index in attribute_indices: |
| eca = self.attributes[index] |
| field = eca.field |
| try: |
| value = self._data[field.name] |
| |
| if not eca.valid(value): |
| raise OmciInvalidTypeError( |
| 'Value "{}" for Entity field "{}" is not valid'.format(value, |
| field.name)) |
| except KeyError: |
| raise OmciUninitializedFieldError( |
| 'Entity field "{}" not set'.format(field.name)) |
| |
| octets = field.addfield(None, octets, value) |
| |
| return octets |
| |
| def attribute_indices_from_data(self): |
| return sorted( |
| self.attribute_name_to_index_map[attr_name] |
| for attr_name in self._data.iterkeys()) |
| |
| byte1_mask_to_attr_indices = dict( |
| (m, bitpos_from_mask(m, 8, -1)) for m in range(256)) |
| byte2_mask_to_attr_indices = dict( |
| (m, bitpos_from_mask(m, 16, -1)) for m in range(256)) |
| |
| @classmethod |
| def attribute_indices_from_mask(cls, mask): |
| # each bit in the 2-byte field denote an attribute index; we use a |
| # lookup table to make lookup a bit faster |
| return \ |
| cls.byte1_mask_to_attr_indices[(mask >> 8) & 0xff] + \ |
| cls.byte2_mask_to_attr_indices[(mask & 0xff)] |
| |
| @classmethod |
| def mask_for(cls, *attr_names): |
| """ |
| Return mask value corresponding to given attributes names |
| :param attr_names: Attribute names |
| :return: integer mask value |
| """ |
| mask = 0 |
| for attr_name in attr_names: |
| index = cls.attribute_name_to_index_map[attr_name] |
| mask |= (1 << (16 - index)) |
| return mask |
| |
| |
| # abbreviations |
| ECA = EntityClassAttribute |
| AA = AttributeAccess |
| OP = EntityOperations |
| |
| |
| class OntData(EntityClass): |
| class_id = 2 |
| hidden = True |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}, |
| range_check=lambda x: x == 0), |
| # Only 1 octet used if GET/SET operation |
| ECA(ShortField("mib_data_sync", 0), {AA.R, AA.W}) |
| ] |
| mandatory_operations = {OP.Get, OP.Set, |
| OP.GetAllAlarms, OP.GetAllAlarmsNext, |
| OP.MibReset, OP.MibUpload, OP.MibUploadNext} |
| |
| |
| class Cardholder(EntityClass): |
| class_id = 5 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}, |
| range_check=lambda x: 0 <= x < 255 or 256 <= x < 511, |
| avc=True), |
| ECA(ByteField("actual_plugin_unit_type", None), {AA.R}), |
| ECA(ByteField("expected_plugin_unit_type", None), {AA.R, AA.W}), |
| ECA(ByteField("expected_port_count", None), {AA.R, AA.W}, |
| optional=True), |
| ECA(StrFixedLenField("expected_equipment_id", None, 20), {AA.R, AA.W}, |
| optional=True, avc=True), |
| ECA(StrFixedLenField("actual_equipment_id", None, 20), {AA.R}, |
| optional=True), |
| ECA(ByteField("protection_profile_pointer", None), {AA.R}, |
| optional=True), |
| ECA(ByteField("invoke_protection_switch", None), {AA.R, AA.W}, |
| optional=True, range_check=lambda x: 0 <= x <= 3), |
| ECA(ByteField("arc", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1, optional=True, avc=True), |
| ECA(ByteField("arc_interval", 0), {AA.R, AA.W}, optional=True), |
| ] |
| mandatory_operations = {OP.Get, OP.Set} |
| notifications = {OP.AttributeValueChange, OP.AlarmNotification} |
| alarms = { |
| 0: 'Plug-in circuit pack missing', |
| 1: 'Plug-in type mismatch alarm', |
| 2: 'Improper card removal', |
| 3: 'Plug-in equipment ID mismatch alarm', |
| 4: 'Protection switch', |
| } |
| |
| |
| class CircuitPack(EntityClass): |
| class_id = 6 |
| attributes = [ |
| ECA(StrFixedLenField("managed_entity_id", None, 22), {AA.R, AA.SBC}, |
| range_check=lambda x: 0 <= x < 255 or 256 <= x < 511), |
| ECA(ByteField("type", None), {AA.R, AA.SBC}), |
| ECA(ByteField("number_of_ports", None), {AA.R}, optional=True), |
| ECA(OmciSerialNumberField("serial_number"), {AA.R}), |
| ECA(StrFixedLenField("version", None, 14), {AA.R}), |
| ECA(StrFixedLenField("vendor_id", None, 4), {AA.R}), |
| ECA(ByteField("administrative_state", None), {AA.R, AA.W}), |
| ECA(ByteField("operational_state", None), {AA.R}, optional=True, avc=True), |
| ECA(ByteField("bridged_or_ip_ind", None), {AA.R, AA.W}, optional=True, |
| range_check=lambda x: 0 <= x <= 2), |
| ECA(StrFixedLenField("equipment_id", None, 20), {AA.R}, optional=True), |
| ECA(ByteField("card_configuration", None), {AA.R, AA.W, AA.SBC}, |
| optional=True), # not really mandatory, see spec ITU-T G.988, 9.1.6 |
| ECA(ByteField("total_tcont_buffer_number", None), {AA.R}, |
| optional=True), # not really mandatory, see spec ITU-T G.988, 9.1.6 |
| ECA(ByteField("total_priority_queue_number", None), {AA.R}, |
| optional=True), # not really mandatory, see spec ITU-T G.988, 9.1.6 |
| ECA(ByteField("total_traffic_scheduler_number", None), {AA.R}, |
| optional=True), # not really mandatory, see spec ITU-T G.988, 9.1.6 |
| ECA(IntField("power_sched_override", None), {AA.R, AA.W}, |
| optional=True) |
| ] |
| mandatory_operations = {OP.Get, OP.Set, OP.Reboot} |
| optional_operations = {OP.Create, OP.Delete, OP.Test} |
| notifications = {OP.AttributeValueChange, OP.AlarmNotification} |
| alarms = { |
| 0: 'Equipment alarm', |
| 1: 'Powering alarm', |
| 2: 'Self-test failure', |
| 3: 'Laser end of life', |
| 4: 'Temperature yellow', |
| 5: 'Temperature red', |
| } |
| |
| class SoftwareImage(EntityClass): |
| class_id = 7 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}, |
| range_check=lambda x: 0 <= x/256 <= 254 or 0 <= x % 256 <= 1), |
| ECA(StrFixedLenField("version", None, 14), {AA.R}, avc=True), |
| ECA(ByteField("is_committed", None), {AA.R}, avc=True, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ByteField("is_active", None), {AA.R}, avc=True, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ByteField("is_valid", None), {AA.R}, avc=True, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(StrFixedLenField("product_code", None, 25), {AA.R}, optional=True, avc=True), |
| ECA(StrFixedLenField("image_hash", None, 16), {AA.R}, optional=True, avc=True), |
| ] |
| mandatory_operations = {OP.Get, OP.StartSoftwareDownload, OP.DownloadSection, |
| OP.EndSoftwareDownload, OP.ActivateSoftware, |
| OP.CommitSoftware} |
| notifications = {OP.AttributeValueChange} |
| |
| |
| class PptpEthernetUni(EntityClass): |
| class_id = 11 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}), |
| ECA(ByteField("expected_type", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 254), |
| ECA(ByteField("sensed_type", 0), {AA.R}, optional=True, avc=True), |
| # TODO: For sensed_type AVC, see note in AT&T OMCI Specification, V3.0, page 123 |
| ECA(ByteField("autodetection_config", 0), {AA.R, AA.W}, |
| range_check=lambda x: x in [0, 1, 2, 3, 4, 5, |
| 0x10, 0x11, 0x12, 0x13, 0x14, |
| 0x20, 0x30], optional=True), # See ITU-T G.988 |
| ECA(ByteField("ethernet_loopback_config", 0), {AA.R, AA.W}, |
| range_check=lambda x: x in [0, 3]), |
| ECA(ByteField("administrative_state", 1), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ByteField("operational_state", 1), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1, optional=True, avc=True), |
| ECA(ByteField("config_ind", 0), {AA.R}, |
| range_check=lambda x: x in [0, 1, 2, 3, 4, 0x11, 0x12, 0x13]), |
| ECA(ShortField("max_frame_size", 1518), {AA.R, AA.W}, optional=True), |
| ECA(ByteField("dte_dce_ind", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 2), |
| ECA(ShortField("pause_time", 0), {AA.R, AA.W}, optional=True), |
| ECA(ByteField("bridged_ip_ind", 2), {AA.R, AA.W}, |
| optional=True, range_check=lambda x: 0 <= x <= 2), |
| ECA(ByteField("arc", 0), {AA.R, AA.W}, optional=True, |
| range_check=lambda x: 0 <= x <= 1, avc=True), |
| ECA(ByteField("arc_interval", 0), {AA.R, AA.W}, optional=True), |
| ECA(ByteField("pppoe_filter", 0), {AA.R, AA.W}, optional=True), |
| ECA(ByteField("power_control", 0), {AA.R, AA.W}, optional=True), |
| ] |
| mandatory_operations = {OP.Get, OP.Set} |
| notifications = {OP.AttributeValueChange, OP.AlarmNotification} |
| alarms = { |
| 0: 'LAN Loss Of Signal', |
| } |
| |
| |
| class MacBridgeServiceProfile(EntityClass): |
| class_id = 45 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ByteField("spanning_tree_ind", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ByteField("learning_ind", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ByteField("port_bridging_ind", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ShortField("priority", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("max_age", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 0x0600 <= x <= 0x2800), |
| ECA(ShortField("hello_time", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 0x0100 <= x <= 0x0A00), |
| ECA(ShortField("forward_delay", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 0x0400 <= x <= 0x1E00), |
| ECA(ByteField("unknown_mac_address_discard", None), |
| {AA.R, AA.W, AA.SBC}, range_check=lambda x: 0 <= x <= 1), |
| ECA(ByteField("mac_learning_depth", None), |
| {AA.R, AA.W, AA.SBC}, optional=True), |
| ECA(ByteField("dynamic_filtering_ageing_time", None), |
| {AA.R, AA.W, AA.SBC}, optional=True), |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set} |
| |
| |
| class MacBridgePortConfigurationData(EntityClass): |
| class_id = 47 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ShortField("bridge_id_pointer", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ByteField("port_num", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ByteField("tp_type", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 1 <= x <= 12), |
| ECA(ShortField("tp_pointer", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("port_priority", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("port_path_cost", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ByteField("port_spanning_tree_in", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ByteField("encapsulation_methods", None), {AA.R, AA.W, AA.SBC}, |
| optional=True, deprecated=True), |
| ECA(ByteField("lan_fcs_ind", None), {AA.R, AA.W, AA.SBC}, |
| optional=True, deprecated=True), |
| ECA(MACField("port_mac_address", None), {AA.R}, optional=True), |
| ECA(ShortField("outbound_td_pointer", None), {AA.R, AA.W}, |
| optional=True), |
| ECA(ShortField("inbound_td_pointer", None), {AA.R, AA.W}, |
| optional=True), |
| # TODO: |
| ECA(ByteField("mac_learning_depth", 0), {AA.R, AA.W, AA.SBC}, |
| optional=True), |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set} |
| notifications = {OP.AlarmNotification} |
| alarms = { |
| 0: 'Port blocking', |
| } |
| |
| |
| class MacBridgePortFilterPreAssignTable(EntityClass): |
| class_id = 79 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ShortField("ipv4_multicast", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ShortField("ipv6_multicast", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ShortField("ipv4_broadcast", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ShortField("rarp", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ShortField("ipx", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ShortField("netbeui", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ShortField("appletalk", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ShortField("bridge_management_information", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ShortField("arp", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ShortField("pppoe_broadcast", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1) |
| ] |
| mandatory_operations = {OP.Get, OP.Set} |
| |
| |
| class VlanTaggingFilterData(EntityClass): |
| class_id = 84 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(FieldListField("vlan_filter_list", None, |
| ShortField('', 0), count_from=lambda _: 12), |
| {AA.R, AA.W, AA.SBC}), |
| ECA(ByteField("forward_operation", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 0x00 <= x <= 0x21), |
| ECA(ByteField("number_of_entries", None), {AA.R, AA.W, AA.SBC}) |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set} |
| |
| |
| class Ieee8021pMapperServiceProfile(EntityClass): |
| class_id = 130 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ShortField("tp_pointer", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("interwork_tp_pointer_for_p_bit_priority_0", |
| OmciNullPointer), {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("interwork_tp_pointer_for_p_bit_priority_1", |
| OmciNullPointer), {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("interwork_tp_pointer_for_p_bit_priority_2", |
| OmciNullPointer), {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("interwork_tp_pointer_for_p_bit_priority_3", |
| OmciNullPointer), {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("interwork_tp_pointer_for_p_bit_priority_4", |
| OmciNullPointer), {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("interwork_tp_pointer_for_p_bit_priority_5", |
| OmciNullPointer), {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("interwork_tp_pointer_for_p_bit_priority_6", |
| OmciNullPointer), {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("interwork_tp_pointer_for_p_bit_priority_7", |
| OmciNullPointer), {AA.R, AA.W, AA.SBC}), |
| ECA(ByteField("unmarked_frame_option", None), |
| {AA.R, AA.W, AA.SBC}, range_check=lambda x: 0 <= x <= 1), |
| ECA(StrFixedLenField("dscp_to_p_bit_mapping", None, length=24), |
| {AA.R, AA.W}), # TODO: Would a custom 3-bit group bitfield work better? |
| ECA(ByteField("default_p_bit_marking", None), |
| {AA.R, AA.W, AA.SBC}), |
| ECA(ByteField("tp_type", None), {AA.R, AA.W, AA.SBC}, |
| optional=True, range_check=lambda x: 0 <= x <= 8) |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set} |
| |
| |
| class OltG(EntityClass): |
| class_id = 131 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}, |
| range_check=lambda x: x == 0), |
| ECA(StrFixedLenField("olt_vendor_id", None, 4), {AA.R, AA.W}), |
| ECA(StrFixedLenField("equipment_id", None, 20), {AA.R, AA.W}), |
| ECA(StrFixedLenField("version", None, 14), {AA.R, AA.W}), |
| ECA(StrFixedLenField("time_of_day", None, 14), {AA.R, AA.W}) |
| ] |
| mandatory_operations = {OP.Get, OP.Set} |
| |
| |
| class OntPowerShedding(EntityClass): |
| class_id = 133 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}, |
| range_check=lambda x: x == 0), |
| ECA(ShortField("restore_power_time_reset_interval", 0), |
| {AA.R, AA.W}), |
| ECA(ShortField("data_class_shedding_interval", 0), {AA.R, AA.W}), |
| ECA(ShortField("voice_class_shedding_interval", 0), {AA.R, AA.W}), |
| ECA(ShortField("video_overlay_class_shedding_interval", 0), {AA.R, AA.W}), |
| ECA(ShortField("video_return_class_shedding_interval", 0), {AA.R, AA.W}), |
| ECA(ShortField("dsl_class_shedding_interval", 0), {AA.R, AA.W}), |
| ECA(ShortField("atm_class_shedding_interval", 0), {AA.R, AA.W}), |
| ECA(ShortField("ces_class_shedding_interval", 0), {AA.R, AA.W}), |
| ECA(ShortField("frame_class_shedding_interval", 0), {AA.R, AA.W}), |
| ECA(ShortField("sonet_class_shedding_interval", 0), {AA.R, AA.W}), |
| ECA(ShortField("shedding_status", None), {AA.R, AA.W}, optional=True, |
| avc=True), |
| ] |
| mandatory_operations = {OP.Get, OP.Set} |
| notifications = {OP.AttributeValueChange} |
| |
| |
| class IpHostConfigData(EntityClass): |
| class_id = 134 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}), |
| ECA(BitField("ip_options", 0, size=8), {AA.R, AA.W}), |
| ECA(MACField("mac_address", None), {AA.R}), |
| ECA(StrFixedLenField("onu_identifier", None, 25), {AA.R, AA.W}), |
| ECA(IPField("ip_address", None), {AA.R, AA.W}), |
| ECA(IPField("mask", None), {AA.R, AA.W}), |
| ECA(IPField("gateway", None), {AA.R, AA.W}), |
| ECA(IPField("primary_dns", None), {AA.R, AA.W}), |
| ECA(IPField("secondary_dns", None), {AA.R, AA.W}), |
| ECA(IPField("current_address", None), {AA.R}, avc=True), |
| ECA(IPField("current_mask", None), {AA.R}, avc=True), |
| ECA(IPField("current_gateway", None), {AA.R}, avc=True), |
| ECA(IPField("current_primary_dns", None), {AA.R}, avc=True), |
| ECA(IPField("current_secondary_dns", None), {AA.R}, avc=True), |
| ECA(StrFixedLenField("domain_name", None, 25), {AA.R}, avc=True), |
| ECA(StrFixedLenField("host_name", None, 25), {AA.R}, avc=True), |
| ECA(ShortField("relay_agent_options", None), {AA.R, AA.W}, |
| optional=True), |
| ] |
| mandatory_operations = {OP.Get, OP.Set, OP.Test} |
| notifications = {OP.AttributeValueChange} |
| |
| |
| class VlanTaggingOperation(Packet): |
| name = "VlanTaggingOperation" |
| fields_desc = [ |
| BitField("filter_outer_priority", 0, 4), |
| BitField("filter_outer_vid", 0, 13), |
| BitField("filter_outer_tpid_de", 0, 3), |
| BitField("pad1", 0, 12), |
| |
| BitField("filter_inner_priority", 0, 4), |
| BitField("filter_inner_vid", 0, 13), |
| BitField("filter_inner_tpid_de", 0, 3), |
| BitField("pad2", 0, 8), |
| BitField("filter_ether_type", 0, 4), |
| |
| BitField("treatment_tags_to_remove", 0, 2), |
| BitField("pad3", 0, 10), |
| BitField("treatment_outer_priority", 0, 4), |
| BitField("treatment_outer_vid", 0, 13), |
| BitField("treatment_outer_tpid_de", 0, 3), |
| |
| BitField("pad4", 0, 12), |
| BitField("treatment_inner_priority", 0, 4), |
| BitField("treatment_inner_vid", 0, 13), |
| BitField("treatment_inner_tpid_de", 0, 3), |
| ] |
| |
| def to_json(self): |
| return json.dumps(self.fields, separators=(',', ':')) |
| |
| @staticmethod |
| def json_from_value(value): |
| bits = BitArray(hex=hexlify(value)) |
| temp = VlanTaggingOperation( |
| filter_outer_priority=bits[0:4].uint, # 4 <-size |
| filter_outer_vid=bits[4:17].uint, # 13 |
| filter_outer_tpid_de=bits[17:20].uint, # 3 |
| # pad 12 |
| filter_inner_priority=bits[32:36].uint, # 4 |
| filter_inner_vid=bits[36:49].uint, # 13 |
| filter_inner_tpid_de=bits[49:52].uint, # 3 |
| # pad 8 |
| filter_ether_type=bits[60:64].uint, # 4 |
| treatment_tags_to_remove=bits[64:66].uint, # 2 |
| # pad 10 |
| treatment_outer_priority=bits[76:80].uint, # 4 |
| treatment_outer_vid=bits[80:93].uint, # 13 |
| treatment_outer_tpid_de=bits[93:96].uint, # 3 |
| # pad 12 |
| treatment_inner_priority=bits[108:112].uint, # 4 |
| treatment_inner_vid=bits[112:125].uint, # 13 |
| treatment_inner_tpid_de=bits[125:128].uint, # 3 |
| ) |
| return json.dumps(temp.fields, separators=(',', ':')) |
| |
| |
| class ExtendedVlanTaggingOperationConfigurationData(EntityClass): |
| class_id = 171 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ByteField("association_type", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 0 <= x <= 11), |
| ECA(ShortField("received_vlan_tagging_operation_table_max_size", None), |
| {AA.R}), |
| ECA(ShortField("input_tpid", None), {AA.R, AA.W}), |
| ECA(ShortField("output_tpid", None), {AA.R, AA.W}), |
| ECA(ByteField("downstream_mode", None), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 8), |
| ECA(StrFixedLenField("received_frame_vlan_tagging_operation_table", |
| VlanTaggingOperation, 16), {AA.R, AA.W}), |
| ECA(ShortField("associated_me_pointer", None), {AA.R, AA.W, AA.SBC}), |
| ECA(FieldListField("dscp_to_p_bit_mapping", None, |
| BitField('', 0, size=3), count_from=lambda _: 64), |
| {AA.R, AA.W}), |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Set, OP.Get, OP.GetNext} |
| optional_operations = {OP.SetTable} |
| |
| |
| class OntG(EntityClass): |
| class_id = 256 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}, |
| range_check=lambda x: x == 0), |
| ECA(StrFixedLenField("vendor_id", None, 4), {AA.R}), |
| ECA(StrFixedLenField("version", None, 14), {AA.R}), |
| ECA(OmciSerialNumberField("serial_number"), {AA.R}), |
| ECA(ByteField("traffic_management_options", None), {AA.R}, |
| range_check=lambda x: 0 <= x <= 2), |
| ECA(ByteField("vp_vc_cross_connection_option", 0), {AA.R}, |
| optional=True, deprecated=True), |
| ECA(ByteField("battery_backup", None), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ByteField("administrative_state", None), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ByteField("operational_state", None), {AA.R}, optional=True, |
| range_check=lambda x: 0 <= x <= 1, avc=True), |
| ECA(ByteField("ont_survival_time", None), {AA.R}, optional=True), |
| ECA(StrFixedLenField("logical_onu_id", None, 24), {AA.R}, |
| optional=True, avc=True), |
| ECA(StrFixedLenField("logical_password", None, 12), {AA.R}, |
| optional=True, avc=True), |
| ECA(ByteField("credentials_status", None), {AA.R, AA.W}, |
| optional=True, range_check=lambda x: 0 <= x <= 4), |
| ECA(BitField("extended_tc_layer_options", None, size=16), {AA.R}, |
| optional=True), |
| ] |
| mandatory_operations = { |
| OP.Get, OP.Set, OP.Reboot, OP.Test, OP.SynchronizeTime} |
| notifications = {OP.TestResult, OP.AttributeValueChange, |
| OP.AlarmNotification} |
| alarms = { |
| 0: 'Equipment alarm', |
| 1: 'Powering alarm', |
| 2: 'Battery missing', |
| 3: 'Battery failure', |
| 4: 'Battery low', |
| 5: 'Physical intrusion', |
| 6: 'Self-test failure', |
| 7: 'Dying gasp', |
| 8: 'Temperature yellow', |
| 9: 'Temperature red', |
| 10: 'Voltage yellow', |
| 11: 'Voltage red', |
| 12: 'ONU manual power off', |
| 13: 'Invalid image', |
| 14: 'PSE overload yellow', |
| 15: 'PSE overload red', |
| } |
| |
| |
| class Ont2G(EntityClass): |
| class_id = 257 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}, |
| range_check=lambda x: x == 0), |
| ECA(StrFixedLenField("equipment_id", None, 20), {AA.R}), |
| ECA(ByteField("omcc_version", None), {AA.R}, avc=True), |
| ECA(ShortField("vendor_product_code", None), {AA.R}), |
| ECA(ByteField("security_capability", None), {AA.R}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ByteField("security_mode", None), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ShortField("total_priority_queue_number", None), {AA.R}), |
| ECA(ByteField("total_traffic_scheduler_number", None), {AA.R}), |
| ECA(ByteField("mode", None), {AA.R}, deprecated=True), |
| ECA(ShortField("total_gem_port_id_number", None), {AA.R}), |
| ECA(IntField("sys_uptime", None), {AA.R}), |
| ECA(BitField("connectivity_capability", None, size=16), {AA.R}), |
| ECA(ByteField("current_connectivity_mode", None), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 7), |
| ECA(BitField("qos_configuration_flexibility", None, size=16), |
| {AA.R}, optional=True), |
| ECA(ShortField("priority_queue_scale_factor", None), {AA.R, AA.W}, |
| optional=True), |
| ] |
| mandatory_operations = {OP.Get, OP.Set} |
| notifications = {OP.AttributeValueChange} |
| |
| |
| class Tcont(EntityClass): |
| class_id = 262 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}), |
| ECA(ShortField("alloc_id", None), {AA.R, AA.W}), |
| ECA(ByteField("mode_indicator", 1), {AA.R}, deprecated=True), |
| ECA(ByteField("policy", None), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 2), |
| ] |
| mandatory_operations = {OP.Get, OP.Set} |
| |
| |
| class AniG(EntityClass): |
| class_id = 263 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}), |
| ECA(ByteField("sr_indication", None), {AA.R}), |
| ECA(ShortField("total_tcont_number", None), {AA.R}), |
| ECA(ShortField("gem_block_length", None), {AA.R, AA.W}), |
| ECA(ByteField("piggyback_dba_reporting", None), {AA.R}, |
| range_check=lambda x: 0 <= x <= 4), |
| ECA(ByteField("whole_ont_dba_reporting", None), {AA.R}, |
| deprecated=True), |
| ECA(ByteField("sf_threshold", 5), {AA.R, AA.W}), |
| ECA(ByteField("sd_threshold", 9), {AA.R, AA.W}), |
| ECA(ByteField("arc", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1, avc=True), |
| ECA(ByteField("arc_interval", 0), {AA.R, AA.W}), |
| ECA(ShortField("optical_signal_level", None), {AA.R}), |
| ECA(ByteField("lower_optical_threshold", 0xFF), {AA.R, AA.W}), |
| ECA(ByteField("upper_optical_threshold", 0xFF), {AA.R, AA.W}), |
| ECA(ShortField("ont_response_time", None), {AA.R}), |
| ECA(ShortField("transmit_optical_level", None), {AA.R}), |
| ECA(ByteField("lower_transmit_power_threshold", 0x81), {AA.R, AA.W}), |
| ECA(ByteField("upper_transmit_power_threshold", 0x81), {AA.R, AA.W}), |
| ] |
| mandatory_operations = {OP.Get, OP.Set, OP.Test} |
| notifications = {OP.AttributeValueChange, OP.AlarmNotification} |
| alarms = { |
| 0: 'Low received optical power', |
| 1: 'High received optical power', |
| 2: 'Signal fail', |
| 3: 'Signal degrade', |
| 4: 'Low transmit optical power', |
| 5: 'High transmit optical power', |
| 6: 'Laser bias current', |
| } |
| |
| |
| class UniG(EntityClass): |
| class_id = 264 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}), |
| ECA(ShortField("configuration_option_status", None), {AA.R, AA.W}, |
| deprecated=True), |
| ECA(ByteField("administrative_state", None), {AA.R, AA.W}), |
| ECA(ByteField("management_capability", None), {AA.R}, |
| range_check=lambda x: 0 <= x <= 2), |
| ECA(ShortField("non_omci_management_identifier", None), {AA.R, AA.W}), |
| ECA(ShortField("relay_agent_options", None), {AA.R, AA.W}, |
| optional=True), |
| ] |
| mandatory_operations = {OP.Get, OP.Set} |
| |
| |
| class GemInterworkingTp(EntityClass): |
| class_id = 266 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ShortField("gem_port_network_ctp_pointer", None), |
| {AA.R, AA.W, AA.SBC}), |
| ECA(ByteField("interworking_option", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 0 <= x <= 7), |
| ECA(ShortField("service_profile_pointer", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("interworking_tp_pointer", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ByteField("pptp_counter", None), {AA.R}, optional=True), |
| ECA(ByteField("operational_state", None), {AA.R}, optional=True, |
| range_check=lambda x: 0 <= x <= 1, avc=True), |
| ECA(ShortField("gal_profile_pointer", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ByteField("gal_loopback_configuration", 0), |
| {AA.R, AA.W}, range_check=lambda x: 0 <= x <= 1), |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set} |
| notifications = {OP.AttributeValueChange, OP.AlarmNotification} |
| alarms = { |
| 6: 'Operational state change', |
| } |
| |
| |
| class GemPortNetworkCtp(EntityClass): |
| class_id = 268 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ShortField("port_id", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("tcont_pointer", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ByteField("direction", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 1 <= x <= 3), |
| ECA(ShortField("traffic_management_pointer_upstream", None), |
| {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("traffic_descriptor_profile_pointer", None), |
| {AA.R, AA.W, AA.SBC}, optional=True), |
| ECA(ByteField("uni_counter", None), {AA.R}, optional=True), |
| ECA(ShortField("priority_queue_pointer_downstream", None), |
| {AA.R, AA.W, AA.SBC}), |
| ECA(ByteField("encryption_state", None), {AA.R}, optional=True), |
| ECA(ShortField("traffic_desc_profile_pointer_downstream", None), |
| {AA.R, AA.W, AA.SBC}, optional=True), |
| ECA(ShortField("encryption_key_ring", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 0 <= x <= 3) |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set} |
| notifications = {OP.AlarmNotification} |
| alarms = { |
| 5: 'End-to-end loss of continuity', |
| } |
| |
| |
| class GalEthernetProfile(EntityClass): |
| class_id = 272 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ShortField("max_gem_payload_size", None), {AA.R, AA.W, AA.SBC}), |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set} |
| |
| |
| class PriorityQueueG(EntityClass): |
| class_id = 277 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}), |
| ECA(ByteField("queue_configuration_option", None), {AA.R}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ShortField("maximum_queue_size", None), {AA.R}), |
| ECA(ShortField("allocated_queue_size", None), {AA.R, AA.W}), |
| ECA(ShortField("discard_block_counter_reset_interval", None), {AA.R, AA.W}), |
| ECA(ShortField("threshold_value_for_discarded_blocks", None), {AA.R, AA.W}), |
| ECA(IntField("related_port", None), {AA.R}), |
| ECA(ShortField("traffic_scheduler_pointer", 0), {AA.R, AA.W}), |
| ECA(ByteField("weight", 1), {AA.R, AA.W}), |
| ECA(ShortField("back_pressure_operation", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(IntField("back_pressure_time", 0), {AA.R, AA.W}), |
| ECA(ShortField("back_pressure_occur_queue_threshold", None), {AA.R, AA.W}), |
| ECA(ShortField("back_pressure_clear_queue_threshold", None), {AA.R, AA.W}), |
| # TODO: Custom field of 4 2-byte values would help below |
| ECA(LongField("packet_drop_queue_thresholds", None), {AA.R, AA.W}, |
| optional=True), |
| ECA(ShortField("packet_drop_max_p", 0xFFFF), {AA.R, AA.W}, optional=True), |
| ECA(ByteField("queue_drop_w_q", 9), {AA.R, AA.W}, optional=True), |
| ECA(ByteField("drop_precedence_colour_marking", 0), {AA.R, AA.W}, |
| optional=True, range_check=lambda x: 0 <= x <= 7), |
| ] |
| mandatory_operations = {OP.Get, OP.Set} |
| notifications = {OP.AlarmNotification} |
| alarms = { |
| 0: 'Block loss', |
| } |
| |
| |
| class TrafficSchedulerG(EntityClass): |
| class_id = 278 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}), |
| ECA(ShortField("tcont_pointer", None), {AA.R}), |
| ECA(ShortField("traffic_scheduler_pointer", None), {AA.R}), |
| ECA(ByteField("policy", None), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 2), |
| ECA(ByteField("priority_weight", 0), {AA.R, AA.W}), |
| ] |
| mandatory_operations = {OP.Get, OP.Set} |
| |
| |
| class MulticastGemInterworkingTp(EntityClass): |
| class_id = 281 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}, |
| range_check=lambda x: x != OmciNullPointer), |
| ECA(ShortField("gem_port_network_ctp_pointer", None), {AA.R, AA.SBC}), |
| ECA(ByteField("interworking_option", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: x in [0, 1, 3, 5]), |
| ECA(ShortField("service_profile_pointer", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("interworking_tp_pointer", 0), {AA.R, AA.W, AA.SBC}, |
| deprecated=True), |
| ECA(ByteField("pptp_counter", None), {AA.R}), |
| ECA(ByteField("operational_state", None), {AA.R}, avc=True, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ShortField("gal_profile_pointer", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ByteField("gal_loopback_configuration", None), {AA.R, AA.W, AA.SBC}, |
| deprecated=True), |
| # TODO add multicast_address_table here (page 85 of spec.) |
| # ECA(...("multicast_address_table", None), {AA.R, AA.W}) |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.GetNext, OP.Set} |
| optional_operations = {OP.SetTable} |
| notifications = {OP.AttributeValueChange, OP.AlarmNotification} |
| alarms = { |
| 0: 'Deprecated', |
| } |
| |
| |
| class AccessControlRow0(Packet): |
| name = "AccessControlRow0" |
| fields_desc = [ |
| BitField("set_ctrl", 0, 2), |
| BitField("row_part_id", 0, 3), |
| BitField("test", 0, 1), |
| BitField("row_key", 0, 10), |
| |
| ShortField("gem_port_id", None), |
| ShortField("vlan_id", None), |
| IPField("src_ip", None), |
| IPField("dst_ip_start", None), |
| IPField("dst_ip_end", None), |
| IntField("ipm_group_bw", None), |
| ShortField("reserved0", 0) |
| ] |
| |
| def to_json(self): |
| return json.dumps(self.fields, separators=(',', ':')) |
| |
| |
| class AccessControlRow1(Packet): |
| name = "AccessControlRow1" |
| fields_desc = [ |
| BitField("set_ctrl", 0, 2), |
| BitField("row_part_id", 0, 3), |
| BitField("test", 0, 1), |
| BitField("row_key", 0, 10), |
| |
| StrFixedLenField("ipv6_src_addr_start_bytes", None, 12), |
| ShortField("preview_length", None), |
| ShortField("preview_repeat_time", None), |
| ShortField("preview_repeat_count", None), |
| ShortField("preview_reset_time", None), |
| ShortField("reserved1", 0) |
| ] |
| |
| def to_json(self): |
| return json.dumps(self.fields, separators=(',', ':')) |
| |
| |
| class AccessControlRow2(Packet): |
| name = "AccessControlRow2" |
| fields_desc = [ |
| BitField("set_ctrl", 0, 2), |
| BitField("row_part_id", 0, 3), |
| BitField("test", 0, 1), |
| BitField("row_key", 0, 10), |
| |
| StrFixedLenField("ipv6_dst_addr_start_bytes", None, 12), |
| StrFixedLenField("reserved2", None, 10) |
| ] |
| |
| def to_json(self): |
| return json.dumps(self.fields, separators=(',', ':')) |
| |
| |
| class DownstreamIgmpMulticastTci(Packet): |
| name = "DownstreamIgmpMulticastTci" |
| fields_desc = [ |
| ByteField("ctrl_type", None), |
| ShortField("tci", None) |
| ] |
| |
| def to_json(self): |
| return json.dumps(self.fields, separators=(',', ':')) |
| |
| |
| class MulticastOperationsProfile(EntityClass): |
| class_id = 309 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}, |
| range_check=lambda x: x != 0 and x != OmciNullPointer), |
| ECA(ByteField("igmp_version", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: x in [1, 2, 3, 16, 17]), |
| ECA(ByteField("igmp_function", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 0 <= x <= 2), |
| ECA(ByteField("immediate_leave", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ShortField("us_igmp_tci", None), {AA.R, AA.W, AA.SBC}, optional=True), |
| ECA(ByteField("us_igmp_tag_ctrl", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 0 <= x <= 3, optional=True), |
| ECA(IntField("us_igmp_rate", None), {AA.R, AA.W, AA.SBC}, optional=True), |
| # TODO: need to make table and add column data |
| ECA(StrFixedLenField( |
| "dynamic_access_control_list_table", None, 24), {AA.R, AA.W}), |
| # TODO: need to make table and add column data |
| ECA(StrFixedLenField( |
| "static_access_control_list_table", None, 24), {AA.R, AA.W}), |
| # TODO: need to make table and add column data |
| ECA(StrFixedLenField("lost_groups_list_table", None, 10), {AA.R}), |
| ECA(ByteField("robustness", None), {AA.R, AA.W, AA.SBC}), |
| ECA(IntField("querier_ip", None), {AA.R, AA.W, AA.SBC}), |
| ECA(IntField("query_interval", None), {AA.R, AA.W, AA.SBC}), |
| ECA(IntField("querier_max_response_time", None), {AA.R, AA.W, AA.SBC}), |
| ECA(IntField("last_member_response_time", 10), {AA.R, AA.W}), |
| ECA(ByteField("unauthorized_join_behaviour", None), {AA.R, AA.W}), |
| ECA(StrFixedLenField("ds_igmp_mcast_tci", None, 3), {AA.R, AA.W, AA.SBC}, optional=True) |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Set, OP.Get, OP.GetNext} |
| optional_operations = {OP.SetTable} |
| notifications = {OP.AlarmNotification} |
| alarms = { |
| 0: 'Lost multicast group', |
| } |
| |
| |
| class MulticastServicePackage(Packet): |
| name = "MulticastServicePackage" |
| fields_desc = [ |
| BitField("set_ctrl", 0, 2), |
| BitField("reserved0", 0, 4), |
| BitField("row_key", 0, 10), |
| |
| ShortField("vid_uni", None), |
| ShortField("max_simultaneous_groups", None), |
| IntField("max_multicast_bw", None), |
| ShortField("mcast_operations_profile_pointer", None), |
| StrFixedLenField("reserved1", None, 8) |
| ] |
| |
| def to_json(self): |
| return json.dumps(self.fields, separators=(',', ':')) |
| |
| |
| class AllowedPreviewGroupsRow0(Packet): |
| name = "AllowedPreviewGroupsRow0" |
| fields_desc = [ |
| BitField("set_ctrl", 0, 2), |
| BitField("row_part_id", 0, 3), |
| BitField("reserved0", 0, 1), |
| BitField("row_key", 0, 10), |
| |
| StrFixedLenField("ipv6_pad", 0, 12), |
| IPField("src_ip", None), |
| ShortField("vlan_id_ani", None), |
| ShortField("vlan_id_uni", None) |
| ] |
| |
| def to_json(self): |
| return json.dumps(self.fields, separators=(',', ':')) |
| |
| |
| class AllowedPreviewGroupsRow1(Packet): |
| name = "AllowedPreviewGroupsRow1" |
| fields_desc = [ |
| BitField("set_ctrl", 0, 2), |
| BitField("row_part_id", 0, 3), |
| BitField("reserved0", 0, 1), |
| BitField("row_key", 0, 10), |
| |
| StrFixedLenField("ipv6_pad", 0, 12), |
| IPField("dst_ip", None), |
| ShortField("duration", None), |
| ShortField("time_left", None) |
| ] |
| |
| def to_json(self): |
| return json.dumps(self.fields, separators=(',', ':')) |
| |
| |
| class MulticastSubscriberConfigInfo(EntityClass): |
| class_id = 310 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ByteField("me_type", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ShortField("mcast_operations_profile_pointer", None), |
| {AA.R, AA.W, AA.SBC}), |
| ECA(ShortField("max_simultaneous_groups", None), {AA.R, AA.W, AA.SBC}), |
| ECA(IntField("max_multicast_bandwidth", None), {AA.R, AA.W, AA.SBC}), |
| ECA(ByteField("bandwidth_enforcement", None), {AA.R, AA.W, AA.SBC}, |
| range_check=lambda x: 0 <= x <= 1), |
| # TODO: need to make table and add column data |
| ECA(StrFixedLenField( |
| "multicast_service_package_table", None, 20), {AA.R, AA.W}), |
| # TODO: need to make table and add column data |
| ECA(StrFixedLenField( |
| "allowed_preview_groups_table", None, 22), {AA.R, AA.W}), |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Set, OP.Get, OP.GetNext, |
| OP.SetTable} |
| |
| |
| class VirtualEthernetInterfacePt(EntityClass): |
| class_id = 329 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}, |
| range_check=lambda x: x != 0 and x != OmciNullPointer), |
| ECA(ByteField("administrative_state", None), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ByteField("operational_state", None), {AA.R}, avc=True, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(StrFixedLenField( |
| "interdomain_name", None, 25), {AA.R, AA.W}, optional=True), |
| ECA(ShortField("tcp_udp_pointer", None), {AA.R, AA.W}, optional=True), |
| ECA(ShortField("iana_assigned_port", None), {AA.R}), |
| ] |
| mandatory_operations = {OP.Get, OP.Set} |
| notifications = {OP.AttributeValueChange, OP.AlarmNotification} |
| alarms = { |
| 0: 'Connecting function fail', |
| } |
| |
| |
| class Omci(EntityClass): |
| class_id = 287 |
| hidden = True |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}, |
| range_check=lambda x: x == 0), |
| |
| # TODO: Can this be expressed better in SCAPY, probably not? |
| # On the initial, Get request for either the me_type or message_type |
| # attributes, you will receive a 4 octet value (big endian) that is |
| # the number of octets to 'get-next' to fully load the desired |
| # attribute. For a basic OMCI formatted message, that will be 29 |
| # octets per get-request. |
| # |
| # For the me_type_table, these are 16-bit values (ME Class IDs) |
| # |
| # For the message_type_table, these are 8-bit values (Actions) |
| |
| ECA(FieldListField("me_type_table", None, ByteField('', 0), |
| count_from=lambda _: 29), {AA.R}), |
| ECA(FieldListField("message_type_table", None, ByteField('', 0), |
| count_from=lambda _: 29), {AA.R}), |
| ] |
| mandatory_operations = {OP.Get, OP.GetNext} |
| |
| |
| class EnhSecurityControl(EntityClass): |
| class_id = 332 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}), |
| ECA(BitField("olt_crypto_capabilities", None, 16*8), {AA.W}), |
| # TODO: need to make table and add column data |
| ECA(StrFixedLenField( |
| "olt_random_challenge_table", None, 17), {AA.R, AA.W}), |
| ECA(ByteField("olt_challenge_status", 0), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ByteField("onu_selected_crypto_capabilities", None), {AA.R}), |
| # TODO: need to make table and add column data |
| ECA(StrFixedLenField( |
| "onu_random_challenge_table", None, 16), {AA.R}, avc=True), |
| # TODO: need to make table and add column data |
| ECA(StrFixedLenField( |
| "onu_authentication_result_table", None, 16), {AA.R}, avc=True), |
| # TODO: need to make table and add column data |
| ECA(StrFixedLenField( |
| "olt_authentication_result_table", None, 17), {AA.W}), |
| ECA(ByteField("olt_result_status", None), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ByteField("onu_authentication_status", None), {AA.R}, avc=True, |
| range_check=lambda x: 0 <= x <= 5), |
| ECA(StrFixedLenField( |
| "master_session_key_name", None, 16), {AA.R}), |
| ECA(StrFixedLenField( |
| "broadcast_key_table", None, 18), {AA.R, AA.W}), |
| ECA(ShortField("effective_key_length", None), {AA.R}), |
| |
| ] |
| mandatory_operations = {OP.Set, OP.Get, OP.GetNext} |
| notifications = {OP.AttributeValueChange} |
| |
| |
| class EthernetPMMonitoringHistoryData(EntityClass): |
| class_id = 24 |
| hidden = True |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ByteField("interval_end_time", None), {AA.R}), |
| ECA(ShortField("threshold_data_1_2_id", None), {AA.R, AA.W, AA.SBC}), |
| ECA(IntField("fcs_errors", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("excessive_collision_counter", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("late_collision_counter", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("frames_too_long", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("buffer_overflows_on_rx", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("buffer_overflows_on_tx", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("single_collision_frame_counter", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("multiple_collisions_frame_counter", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("sqe_counter", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("deferred_tx_counter", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("internal_mac_tx_error_counter", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("carrier_sense_error_counter", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("alignment_error_counter", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("internal_mac_rx_error_counter", None), {AA.R}, tca=True, counter=True) |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set, OP.GetCurrentData} |
| notifications = {OP.AlarmNotification} |
| alarms = { |
| 0: 'FCS errors', |
| 1: 'Excessive collision counter', |
| 2: 'Late collision counter', |
| 3: 'Frames too long', |
| 4: 'Buffer overflows on receive', |
| 5: 'Buffer overflows on transmit', |
| 6: 'Single collision frame counter', |
| 7: 'Multiple collision frame counter', |
| 8: 'SQE counter', |
| 9: 'Deferred transmission counter', |
| 10: 'Internal MAC transmit error counter', |
| 11: 'Carrier sense error counter', |
| 12: 'Alignment error counter', |
| 13: 'Internal MAC receive error counter', |
| } |
| |
| |
| class FecPerformanceMonitoringHistoryData(EntityClass): |
| class_id = 312 |
| hidden = True |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ByteField("interval_end_time", None), {AA.R}), |
| ECA(ShortField("threshold_data_1_2_id", None), {AA.R, AA.W, AA.SBC}), |
| ECA(IntField("corrected_bytes", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("corrected_code_words", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("uncorrectable_code_words", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("total_code_words", None), {AA.R}, counter=True), |
| ECA(ShortField("fec_seconds", None), {AA.R}, tca=True, counter=True) |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set, OP.GetCurrentData} |
| notifications = {OP.AlarmNotification} |
| alarms = { |
| 0: 'Corrected bytes', |
| 1: 'Corrected code words', |
| 2: 'Uncorrectable code words', |
| 4: 'FEC seconds', |
| } |
| |
| |
| class EthernetFrameDownstreamPerformanceMonitoringHistoryData(EntityClass): |
| class_id = 321 |
| hidden = True |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ByteField("interval_end_time", None), {AA.R}), |
| ECA(ShortField("threshold_data_1_2_id", None), {AA.R, AA.W, AA.SBC}), |
| ECA(IntField("drop_events", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("octets", None), {AA.R}, counter=True), |
| ECA(IntField("packets", None), {AA.R}, counter=True), |
| ECA(IntField("broadcast_packets", None), {AA.R}, counter=True), |
| ECA(IntField("multicast_packets", None), {AA.R}, counter=True), |
| ECA(IntField("crc_errored_packets", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("undersize_packets", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("oversize_packets", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("64_octets", None), {AA.R}, counter=True), |
| ECA(IntField("65_to_127_octets", None), {AA.R}, counter=True), |
| ECA(IntField("128_to_255_octets", None), {AA.R}, counter=True), |
| ECA(IntField("256_to_511_octets", None), {AA.R}, counter=True), |
| ECA(IntField("512_to_1023_octets", None), {AA.R}, counter=True), |
| ECA(IntField("1024_to_1518_octets", None), {AA.R}, counter=True) |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set, OP.GetCurrentData} |
| notifications = {OP.AlarmNotification} |
| alarms = { |
| 0: 'Drop events', |
| 1: 'CRC errored packets', |
| 2: 'Undersize packets', |
| 3: 'Oversize packets', |
| } |
| |
| |
| class EthernetFrameUpstreamPerformanceMonitoringHistoryData(EntityClass): |
| class_id = 322 |
| hidden = True |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ByteField("interval_end_time", None), {AA.R}), |
| ECA(ShortField("threshold_data_1_2_id", None), {AA.R, AA.W, AA.SBC}), |
| ECA(IntField("drop_events", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("octets", None), {AA.R}, counter=True), |
| ECA(IntField("packets", None), {AA.R}, counter=True), |
| ECA(IntField("broadcast_packets", None), {AA.R}, counter=True), |
| ECA(IntField("multicast_packets", None), {AA.R}, counter=True), |
| ECA(IntField("crc_errored_packets", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("undersize_packets", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("oversize_packets", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("64_octets", None), {AA.R}, counter=True), |
| ECA(IntField("65_to_127_octets", None), {AA.R}, counter=True), |
| ECA(IntField("128_to_255_octets", None), {AA.R}, counter=True), |
| ECA(IntField("256_to_511_octets", None), {AA.R}, counter=True), |
| ECA(IntField("512_to_1023_octets", None), {AA.R}, counter=True), |
| ECA(IntField("1024_to_1518_octets", None), {AA.R}, counter=True) |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set, OP.GetCurrentData} |
| notifications = {OP.AlarmNotification} |
| alarms = { |
| 0: 'Drop events', |
| 1: 'CRC errored packets', |
| 2: 'Undersize packets', |
| 3: 'Oversize packets', |
| } |
| |
| |
| class VeipUni(EntityClass): |
| class_id = 329 |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R}), |
| ECA(ByteField("administrative_state", 1), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1), |
| ECA(ByteField("operational_state", 1), {AA.R, AA.W}, |
| range_check=lambda x: 0 <= x <= 1, optional=True, avc=True), |
| ECA(StrFixedLenField("interdomain_name", None, 25), {AA.R, AA.W}, |
| optional=True), |
| ECA(ShortField("tcp_udp_pointer", None), {AA.R, AA.W}, optional=True), |
| ECA(ShortField("iana_assigned_port", 0xFFFF), {AA.R}) |
| ] |
| mandatory_operations = {OP.Get, OP.Set} |
| notifications = {OP.AttributeValueChange, OP.AlarmNotification} |
| alarms = { |
| 0: 'Connecting function fail' |
| } |
| |
| |
| class EthernetFrameExtendedPerformanceMonitoring(EntityClass): |
| class_id = 334 |
| hidden = True |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ByteField("interval_end_time", None), {AA.R}), |
| # 2-octet field -> Threshold data 1/2 ID |
| # 2-octet field -> Parent ME Class |
| # 2-octet field -> Parent ME Instance |
| # 2-octet field -> Accumulation disable |
| # 2-octet field -> TCA Disable |
| # 2-octet field -> Control fields bitmap |
| # 2-octet field -> TCI |
| # 2-octet field -> Reserved |
| ECA(FieldListField("control_block", None, ShortField('', 0), |
| count_from=lambda _: 8), {AA.R, AA.W, AA.SBC}), |
| ECA(IntField("drop_events", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("octets", None), {AA.R}, counter=True), |
| ECA(IntField("packets", None), {AA.R}, counter=True), |
| ECA(IntField("broadcast_packets", None), {AA.R}, counter=True), |
| ECA(IntField("multicast_packets", None), {AA.R}, counter=True), |
| ECA(IntField("crc_errored_packets", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("undersize_packets", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("oversize_packets", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("64_octets", None), {AA.R}, counter=True), |
| ECA(IntField("65_to_127_octets", None), {AA.R}, counter=True), |
| ECA(IntField("128_to_255_octets", None), {AA.R}, counter=True), |
| ECA(IntField("256_to_511_octets", None), {AA.R}, counter=True), |
| ECA(IntField("512_to_1023_octets", None), {AA.R}, counter=True), |
| ECA(IntField("1024_to_1518_octets", None), {AA.R}, counter=True) |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set} |
| optional_operations = {OP.GetCurrentData} |
| notifications = {OP.AlarmNotification} |
| alarms = { |
| 0: 'Drop events', |
| 1: 'CRC errored packets', |
| 2: 'Undersize packets', |
| 3: 'Oversize packets', |
| } |
| |
| |
| class EthernetFrameExtendedPerformanceMonitoring64Bit(EntityClass): |
| class_id = 426 |
| hidden = True |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ByteField("interval_end_time", None), {AA.R}), |
| # 2-octet field -> Threshold data 1/2 ID |
| # 2-octet field -> Parent ME Class |
| # 2-octet field -> Parent ME Instance |
| # 2-octet field -> Accumulation disable |
| # 2-octet field -> TCA Disable |
| # 2-octet field -> Control fields bitmap |
| # 2-octet field -> TCI |
| # 2-octet field -> Reserved |
| ECA(FieldListField("control_block", None, ShortField('', 0), |
| count_from=lambda _: 8), {AA.R, AA.W, AA.SBC}), |
| ECA(LongField("drop_events", None), {AA.R}, tca=True, counter=True), |
| ECA(LongField("octets", None), {AA.R}, counter=True), |
| ECA(LongField("packets", None), {AA.R}, counter=True), |
| ECA(LongField("broadcast_packets", None), {AA.R}, counter=True), |
| ECA(LongField("multicast_packets", None), {AA.R}, counter=True), |
| ECA(LongField("crc_errored_packets", None), {AA.R}, tca=True, counter=True), |
| ECA(LongField("undersize_packets", None), {AA.R}, tca=True, counter=True), |
| ECA(LongField("oversize_packets", None), {AA.R}, tca=True, counter=True), |
| ECA(LongField("64_octets", None), {AA.R}, counter=True), |
| ECA(LongField("65_to_127_octets", None), {AA.R}, counter=True), |
| ECA(LongField("128_to_255_octets", None), {AA.R}, counter=True), |
| ECA(LongField("256_to_511_octets", None), {AA.R}, counter=True), |
| ECA(LongField("512_to_1023_octets", None), {AA.R}, counter=True), |
| ECA(LongField("1024_to_1518_octets", None), {AA.R}, counter=True) |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set} |
| optional_operations = {OP.GetCurrentData} |
| notifications = {OP.AlarmNotification} |
| alarms = { |
| 0: 'Drop events', |
| 1: 'CRC errored packets', |
| 2: 'Undersize packets', |
| 3: 'Oversize packets', |
| } |
| |
| |
| class GemPortNetworkCtpMonitoringHistoryData(EntityClass): |
| class_id = 341 |
| hidden = True |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ByteField("interval_end_time", None), {AA.R}), |
| ECA(ShortField("threshold_data_1_2_id", None), {AA.R, AA.W, AA.SBC}), |
| ECA(IntField("transmitted_gem_frames", None), {AA.R}, counter=True), |
| ECA(IntField("received_gem_frames", None), {AA.R}, counter=True), |
| ECA(LongField("received_payload_bytes", None), {AA.R}, counter=True), |
| ECA(LongField("transmitted_payload_bytes", None), {AA.R}, counter=True), |
| ECA(IntField("encryption_key_errors", None), {AA.R}, tca=True, counter=True) |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set, OP.GetCurrentData} |
| notifications = {OP.AlarmNotification} |
| alarms = { |
| 1: 'Encryption key errors', |
| } |
| |
| |
| class XgPonTcPerformanceMonitoringHistoryData(EntityClass): |
| class_id = 344 |
| hidden = True |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ByteField("interval_end_time", None), {AA.R}), |
| ECA(ShortField("threshold_data_1_2_id", None), {AA.R, AA.W, AA.SBC}), |
| ECA(IntField("psbd_hec_error_count", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("xgtc_hec_error_count", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("unknown_profile_count", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("transmitted_xgem_frames", None), {AA.R}, counter=True), |
| ECA(IntField("fragment_xgem_frames", None), {AA.R}, counter=True), |
| ECA(IntField("xgem_hec_lost_words_count", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("xgem_key_errors", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("xgem_hec_error_count", None), {AA.R}, tca=True, counter=True) |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set} |
| optional_operations = {OP.GetCurrentData} |
| notifications = {OP.AlarmNotification} |
| alarms = { |
| 1: 'PSBd HEC error count', |
| 2: 'XGTC HEC error count', |
| 3: 'Unknown profile count', |
| 4: 'XGEM HEC loss count', |
| 5: 'XGEM key errors', |
| 6: 'XGEM HEC error count', |
| } |
| |
| |
| class XgPonDownstreamPerformanceMonitoringHistoryData(EntityClass): |
| class_id = 345 |
| hidden = True |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ByteField("interval_end_time", None), {AA.R},), |
| ECA(ShortField("threshold_data_1_2_id", None), {AA.R, AA.W, AA.SBC}), |
| ECA(IntField("ploam_mic_error_count", None), {AA.R}, tca=True, counter=True), |
| ECA(IntField("downstream_ploam_messages_count", None), {AA.R}, counter=True), |
| ECA(IntField("profile_messages_received", None), {AA.R}, counter=True), |
| ECA(IntField("ranging_time_messages_received", None), {AA.R}, counter=True), |
| ECA(IntField("deactivate_onu_id_messages_received", None), {AA.R}, counter=True), |
| ECA(IntField("disable_serial_number_messages_received", None), {AA.R}, counter=True), |
| ECA(IntField("request_registration_messages_received", None), {AA.R}, counter=True), |
| ECA(IntField("assign_alloc_id_messages_received", None), {AA.R}, counter=True), |
| ECA(IntField("key_control_messages_received", None), {AA.R}, counter=True), |
| ECA(IntField("sleep_allow_messages_received", None), {AA.R}, counter=True), |
| ECA(IntField("baseline_omci_messages_received_count", None), {AA.R}, counter=True), |
| ECA(IntField("extended_omci_messages_received_count", None), {AA.R}, counter=True), |
| ECA(IntField("assign_onu_id_messages_received", None), {AA.R}, counter=True), |
| ECA(IntField("omci_mic_error_count", None), {AA.R}, tca=True, counter=True), |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set} |
| optional_operations = {OP.GetCurrentData} |
| notifications = {OP.AlarmNotification} |
| alarms = { |
| 1: 'PLOAM MIC error count', |
| 2: 'OMCI MIC error count', |
| } |
| |
| |
| class XgPonUpstreamPerformanceMonitoringHistoryData(EntityClass): |
| class_id = 346 |
| hidden = True |
| attributes = [ |
| ECA(ShortField("managed_entity_id", None), {AA.R, AA.SBC}), |
| ECA(ByteField("interval_end_time", None), {AA.R}), |
| ECA(ShortField("threshold_data_1_2_id", None), {AA.R, AA.W, AA.SBC}), |
| ECA(IntField("upstream_ploam_message_count", None), {AA.R}, counter=True), |
| ECA(IntField("serial_number_onu_message_count", None), {AA.R}, counter=True), |
| ECA(IntField("registration_message_count", None), {AA.R}, counter=True), |
| ECA(IntField("key_report_message_count", None), {AA.R}, counter=True), |
| ECA(IntField("acknowledge_message_count", None), {AA.R}, counter=True), |
| ECA(IntField("sleep_request_message_count", None), {AA.R}, counter=True), |
| ] |
| mandatory_operations = {OP.Create, OP.Delete, OP.Get, OP.Set} |
| optional_operations = {OP.GetCurrentData} |
| |
| |
| # entity class lookup table from entity_class values |
| entity_classes_name_map = dict( |
| inspect.getmembers(sys.modules[__name__], |
| lambda o: inspect.isclass(o) and \ |
| issubclass(o, EntityClass) and \ |
| o is not EntityClass) |
| ) |
| |
| entity_classes = [c for c in entity_classes_name_map.itervalues()] |
| entity_id_to_class_map = dict((c.class_id, c) for c in entity_classes) |