blob: c69d00b5c7330821dba874ddb0c3e82cd3e9e376 [file] [log] [blame]
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
* Copyright 2020-present Open Networking Foundation
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
* http://www.apache.org/licenses/LICENSE-2.0
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// MocaEthernetPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
// Managed entity MoCA Ethernet performance monitoring history data
const MocaEthernetPerformanceMonitoringHistoryDataClassID = ClassID(163) // 0x00a3
var mocaethernetperformancemonitoringhistorydataBME *ManagedEntityDefinition
// MocaEthernetPerformanceMonitoringHistoryData (Class ID: #163 / 0x00a3)
// This ME collects PM data for an MoCA Ethernet interface. Instances of this ME are created and
// deleted by the OLT.
//
// For a complete discussion of generic PM architecture, refer to clause I.4.
//
// Relationships
// An instance of this ME is associated with an instance of the PPTP MoCA UNI ME.
//
// Attributes
// Managed Entity Id
// This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
// implicitly linked to an instance of the PPTP MoCA UNI. (R, setbycreate) (mandatory) (2-bytes)
//
// Interval End Time
// This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1-byte)
//
// Threshold Data 1_2 Id
// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 and 2 MEs
// that contains PM threshold values. (R,-W, setbycreate) (mandatory) (2-bytes)
//
// Incoming PM refers to upstream traffic received on the UNI; outgoing PM refers to downstream
// traffic transmitted on the UNI.
//
// Incoming Unicast Packets
// (R) (optional) (4-bytes)
//
// Incoming Discarded Packets
// (R) (optional) (4-bytes)
//
// Incoming Errored Packets
// (R) (optional) (4-bytes)
//
// Incoming Unknown Packets
// (R) (optional) (4-bytes)
//
// Incoming Multicast Packets
// (R) (optional) (4-bytes)
//
// Incoming Broadcast Packets
// (R) (optional) (4-bytes)
//
// Incoming Octets
// (R) (optional) (4-bytes)
//
// Outgoing Unicast Packets
// (R) (optional) (4-bytes)
//
// Outgoing Discarded Packets
// (R) (optional) (4-bytes)
//
// Outgoing Errored Packets
// (R) (optional) (4-bytes)
//
// Outgoing Unknown Packets
// (R) (optional) (4-bytes)
//
// Outgoing Multicast Packets
// (R) (optional) (4-bytes)
//
// Outgoing Broadcast Packets
// (R) (optional) (4-bytes)
//
// Outgoing Octets
// (R) (optional) (4-bytes)
//
type MocaEthernetPerformanceMonitoringHistoryData struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
func init() {
mocaethernetperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
Name: "MocaEthernetPerformanceMonitoringHistoryData",
ClassID: 163,
MessageTypes: mapset.NewSetWith(
Create,
Delete,
Get,
Set,
),
AllowedAttributeMask: 0xffff,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
3: Uint32Field("IncomingUnicastPackets", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, true, false, 3),
4: Uint32Field("IncomingDiscardedPackets", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, true, false, 4),
5: Uint32Field("IncomingErroredPackets", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, true, false, 5),
6: Uint32Field("IncomingUnknownPackets", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, true, false, 6),
7: Uint32Field("IncomingMulticastPackets", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, true, false, 7),
8: Uint32Field("IncomingBroadcastPackets", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, true, false, 8),
9: Uint32Field("IncomingOctets", CounterAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, true, false, 9),
10: Uint32Field("OutgoingUnicastPackets", CounterAttributeType, 0x0040, 0, mapset.NewSetWith(Read), false, true, false, 10),
11: Uint32Field("OutgoingDiscardedPackets", CounterAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, true, false, 11),
12: Uint32Field("OutgoingErroredPackets", CounterAttributeType, 0x0010, 0, mapset.NewSetWith(Read), false, true, false, 12),
13: Uint32Field("OutgoingUnknownPackets", CounterAttributeType, 0x0008, 0, mapset.NewSetWith(Read), false, true, false, 13),
14: Uint32Field("OutgoingMulticastPackets", CounterAttributeType, 0x0004, 0, mapset.NewSetWith(Read), false, true, false, 14),
15: Uint32Field("OutgoingBroadcastPackets", CounterAttributeType, 0x0002, 0, mapset.NewSetWith(Read), false, true, false, 15),
16: Uint32Field("OutgoingOctets", CounterAttributeType, 0x0001, 0, mapset.NewSetWith(Read), false, true, false, 16),
},
Access: CreatedByOlt,
Support: UnknownSupport,
Alarms: AlarmMap{
0: "Incoming unicast packets",
1: "Incoming discarded packets",
2: "Incoming errored packets",
3: "Incoming unknown packets",
4: "Incoming multicast packets",
5: "Incoming broadcast packets",
6: "Incoming octets",
7: "Outgoing unicast packets",
8: "Outgoing discarded packets",
9: "Outgoing errored packets",
10: "Outgoing unknown packets",
11: "Outgoing multicast packets",
12: "Outgoing broadcast packets",
13: "Outgoing octets",
},
}
}
// NewMocaEthernetPerformanceMonitoringHistoryData (class ID 163) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewMocaEthernetPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {