Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 1 | /* |
| 2 | * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 3 | * Copyright 2020-present Open Networking Foundation |
| 4 | |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 5 | * Licensed under the Apache License, Version 2.0 (the "License"); |
| 6 | * you may not use this file except in compliance with the License. |
| 7 | * You may obtain a copy of the License at |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 8 | |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 9 | * http://www.apache.org/licenses/LICENSE-2.0 |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 10 | |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 11 | * Unless required by applicable law or agreed to in writing, software |
| 12 | * distributed under the License is distributed on an "AS IS" BASIS, |
| 13 | * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| 14 | * See the License for the specific language governing permissions and |
| 15 | * limitations under the License. |
| 16 | */ |
Chip Boling | 34ebcb6 | 2021-02-02 12:13:58 -0600 | [diff] [blame] | 17 | /* |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 18 | * NOTE: This file was generated, manual edits will be overwritten! |
| 19 | * |
| 20 | * Generated by 'goCodeGenerator.py': |
| 21 | * https://github.com/cboling/OMCI-parser/README.md |
| 22 | */ |
| 23 | |
| 24 | package generated |
| 25 | |
| 26 | import "github.com/deckarep/golang-set" |
| 27 | |
| 28 | // CallControlPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI |
| 29 | // Managed entity Call control performance monitoring history data |
| 30 | const CallControlPerformanceMonitoringHistoryDataClassID ClassID = ClassID(140) |
| 31 | |
| 32 | var callcontrolperformancemonitoringhistorydataBME *ManagedEntityDefinition |
| 33 | |
| 34 | // CallControlPerformanceMonitoringHistoryData (class ID #140) |
| 35 | // This ME collects PM data related to the call control channel. Instances of this ME are created |
| 36 | // and deleted by the OLT. |
| 37 | // |
| 38 | // For a complete discussion of generic PM architecture, refer to clause I.4. |
| 39 | // |
| 40 | // Relationships |
| 41 | // An instance of this ME is associated with an instance of the PPTP POTS UNI ME. |
| 42 | // |
| 43 | // Attributes |
| 44 | // Managed Entity Id |
| 45 | // Managed entity ID: This attribute uniquely identifies each instance of this ME. Through an |
| 46 | // identical ID, this ME is implicitly linked to an instance of the PPTP POTS UNI. (R, setbycreate) |
| 47 | // (mandatory) (2-bytes) |
| 48 | // |
| 49 | // Interval End Time |
| 50 | // Interval end time: This attribute identifies the most recently finished 15-min interval. (R) |
| 51 | // (mandatory) (1-byte) |
| 52 | // |
| 53 | // Threshold Data 1_2 Id |
| 54 | // Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that |
| 55 | // contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold |
| 56 | // data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes) |
| 57 | // |
| 58 | // Call Setup Failures |
| 59 | // Call setup failures: This attribute counts call set-up failures. (R) (mandatory) (4-bytes) |
| 60 | // |
| 61 | // Call Setup Timer |
| 62 | // Call setup timer: This attribute is a high water-mark that records the longest duration of a |
| 63 | // single call set-up detected during this interval. Time is measured in milliseconds from the time |
| 64 | // an initial set-up was requested by the subscriber until the time at which a response was |
| 65 | // provided to the subscriber in the form of busy tone, audible ring tone, etc. (R) (mandatory) |
| 66 | // (4-bytes) |
| 67 | // |
| 68 | // Call Terminate Failures |
| 69 | // Call terminate failures: This attribute counts the number of calls that were terminated with |
| 70 | // cause. (R) (mandatory) (4-bytes) |
| 71 | // |
| 72 | // Analog Port Releases |
| 73 | // Analog port releases: This attribute counts the number of analogue port releases without |
| 74 | // dialling detected (abandoned calls). (R) (mandatory) (4-bytes) |
| 75 | // |
| 76 | // Analog Port Off_Hook Timer |
| 77 | // Analog port off-hook timer: This attribute is a high water-mark that records the longest period |
| 78 | // of a single off-hook detected on the analogue port. Time is measured in milliseconds. (R) |
| 79 | // (mandatory) (4-bytes) |
| 80 | // |
| 81 | type CallControlPerformanceMonitoringHistoryData struct { |
| 82 | ManagedEntityDefinition |
| 83 | Attributes AttributeValueMap |
| 84 | } |
| 85 | |
| 86 | func init() { |
| 87 | callcontrolperformancemonitoringhistorydataBME = &ManagedEntityDefinition{ |
| 88 | Name: "CallControlPerformanceMonitoringHistoryData", |
| 89 | ClassID: 140, |
| 90 | MessageTypes: mapset.NewSetWith( |
| 91 | Create, |
| 92 | Delete, |
| 93 | Get, |
| 94 | Set, |
Chip Boling | 2d51f05 | 2021-02-09 09:04:15 -0600 | [diff] [blame] | 95 | GetCurrentData, |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 96 | ), |
| 97 | AllowedAttributeMask: 0xfe00, |
| 98 | AttributeDefinitions: AttributeDefinitionMap{ |
| 99 | 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 100 | 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1), |
| 101 | 2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2), |
| 102 | 3: Uint32Field("CallSetupFailures", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3), |
| 103 | 4: Uint32Field("CallSetupTimer", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4), |
| 104 | 5: Uint32Field("CallTerminateFailures", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5), |
| 105 | 6: Uint32Field("AnalogPortReleases", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6), |
| 106 | 7: Uint32Field("AnalogPortOffHookTimer", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7), |
| 107 | }, |
| 108 | Access: CreatedByOlt, |
| 109 | Support: UnknownSupport, |
Chip Boling | 34ebcb6 | 2021-02-02 12:13:58 -0600 | [diff] [blame] | 110 | Alarms: AlarmMap{ |
| 111 | 0: "CCPM call set-up fail", |
| 112 | 1: "CCPM set-up timeout", |
| 113 | 2: "CCPM call terminate", |
| 114 | 3: "CCPM port release with no dialling", |
| 115 | 4: "CCPM port offhook timeout", |
| 116 | }, |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 117 | } |
| 118 | } |
| 119 | |
| 120 | // NewCallControlPerformanceMonitoringHistoryData (class ID 140) creates the basic |
| 121 | // Managed Entity definition that is used to validate an ME of this type that |
| 122 | // is received from or transmitted to the OMCC. |
| 123 | func NewCallControlPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| 124 | return NewManagedEntity(*callcontrolperformancemonitoringhistorydataBME, params...) |
| 125 | } |