Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 1 | /* |
| 2 | * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 3 | * Copyright 2020-present Open Networking Foundation |
| 4 | |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 5 | * Licensed under the Apache License, Version 2.0 (the "License"); |
| 6 | * you may not use this file except in compliance with the License. |
| 7 | * You may obtain a copy of the License at |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 8 | |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 9 | * http://www.apache.org/licenses/LICENSE-2.0 |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 10 | |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 11 | * Unless required by applicable law or agreed to in writing, software |
| 12 | * distributed under the License is distributed on an "AS IS" BASIS, |
| 13 | * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| 14 | * See the License for the specific language governing permissions and |
| 15 | * limitations under the License. |
| 16 | */ |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 17 | /* |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 18 | * NOTE: This file was generated, manual edits will be overwritten! |
| 19 | * |
| 20 | * Generated by 'goCodeGenerator.py': |
| 21 | * https://github.com/cboling/OMCI-parser/README.md |
| 22 | */ |
| 23 | |
| 24 | package generated |
| 25 | |
| 26 | import "github.com/deckarep/golang-set" |
| 27 | |
| 28 | // RadiusPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI |
| 29 | // Managed entity Radius performance monitoring history data |
| 30 | const RadiusPerformanceMonitoringHistoryDataClassID ClassID = ClassID(293) |
| 31 | |
| 32 | var radiusperformancemonitoringhistorydataBME *ManagedEntityDefinition |
| 33 | |
| 34 | // RadiusPerformanceMonitoringHistoryData (class ID #293) |
| 35 | // This ME collects performance statistics on an ONU's radius client, particularly as related to |
| 36 | // its IEEE-802.1X operation. |
| 37 | // |
| 38 | // Instances of this ME are created and deleted by the OLT. |
| 39 | // |
| 40 | // For a complete discussion of generic PM architecture, refer to clause I.4. |
| 41 | // |
| 42 | // Relationships |
| 43 | // An instance of this ME is associated with an ONU. |
| 44 | // |
| 45 | // Attributes |
| 46 | // Managed Entity Id |
| 47 | // Managed entity ID: This attribute uniquely identifies each instance of this ME. Through an |
| 48 | // identical ID (namely 0), this ME is implicitly linked to an instance of a dot1X configuration |
| 49 | // profile. (R, setbycreate) (mandatory) (2-bytes) |
| 50 | // |
| 51 | // Interval End Time |
| 52 | // Interval end time: This attribute identifies the most recently finished 15-min interval. (R) |
| 53 | // (mandatory) (1-byte) |
| 54 | // |
| 55 | // Threshold Data 1_2 Id |
| 56 | // Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that |
| 57 | // contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold |
| 58 | // data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes) |
| 59 | // |
| 60 | // Access_Request Packets Transmitted |
| 61 | // Access-request packets transmitted: This attribute counts transmitted radius access-request |
| 62 | // messages, including retransmissions. (R) (mandatory) (4-bytes) |
| 63 | // |
| 64 | // Access_Request Retransmission Count |
| 65 | // Access-request retransmission count: This attribute counts radius access-request |
| 66 | // retransmissions. (R) (mandatory) (4-bytes) |
| 67 | // |
| 68 | // Access_Challenge Packets Received |
| 69 | // Access-challenge packets received: This attribute counts received radius access-challenge |
| 70 | // messages. (R) (mandatory) (4-bytes) |
| 71 | // |
| 72 | // Access_Accept Packets Received |
| 73 | // Access-accept packets received: This attribute counts received radius access-accept messages. |
| 74 | // (R) (mandatory) (4-bytes) |
| 75 | // |
| 76 | // Access_Reject Packets Received |
| 77 | // Access-reject packets received: This attribute counts received radius access-reject messages. |
| 78 | // (R) (mandatory) (4-bytes) |
| 79 | // |
| 80 | // Invalid Radius Packets Received |
| 81 | // Invalid radius packets received: This attribute counts received invalid radius messages. (R) |
| 82 | // (mandatory) (4-bytes) |
| 83 | // |
| 84 | type RadiusPerformanceMonitoringHistoryData struct { |
| 85 | ManagedEntityDefinition |
| 86 | Attributes AttributeValueMap |
| 87 | } |
| 88 | |
| 89 | func init() { |
| 90 | radiusperformancemonitoringhistorydataBME = &ManagedEntityDefinition{ |
| 91 | Name: "RadiusPerformanceMonitoringHistoryData", |
| 92 | ClassID: 293, |
| 93 | MessageTypes: mapset.NewSetWith( |
| 94 | Create, |
| 95 | Delete, |
| 96 | Get, |
| 97 | Set, |
| 98 | ), |
| 99 | AllowedAttributeMask: 0xff00, |
| 100 | AttributeDefinitions: AttributeDefinitionMap{ |
| 101 | 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 102 | 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1), |
| 103 | 2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2), |
| 104 | 3: Uint32Field("AccessRequestPacketsTransmitted", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3), |
| 105 | 4: Uint32Field("AccessRequestRetransmissionCount", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4), |
| 106 | 5: Uint32Field("AccessChallengePacketsReceived", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5), |
| 107 | 6: Uint32Field("AccessAcceptPacketsReceived", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6), |
| 108 | 7: Uint32Field("AccessRejectPacketsReceived", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7), |
| 109 | 8: Uint32Field("InvalidRadiusPacketsReceived", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8), |
| 110 | }, |
| 111 | Access: CreatedByOlt, |
| 112 | Support: UnknownSupport, |
| 113 | } |
| 114 | } |
| 115 | |
| 116 | // NewRadiusPerformanceMonitoringHistoryData (class ID 293) creates the basic |
| 117 | // Managed Entity definition that is used to validate an ME of this type that |
| 118 | // is received from or transmitted to the OMCC. |
| 119 | func NewRadiusPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| 120 | return NewManagedEntity(*radiusperformancemonitoringhistorydataBME, params...) |
| 121 | } |