blob: 277219e0e4ddc710c07e694518d7413d3a5d96d4 [file] [log] [blame]
Holger Hildebrandtfa074992020-03-27 15:42:06 +00001/*
2 * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
3 * Copyright 2020-present Open Networking Foundation
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +00004 *
Holger Hildebrandtfa074992020-03-27 15:42:06 +00005 * Licensed under the Apache License, Version 2.0 (the "License");
6 * you may not use this file except in compliance with the License.
7 * You may obtain a copy of the License at
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +00008 *
Holger Hildebrandtfa074992020-03-27 15:42:06 +00009 * http://www.apache.org/licenses/LICENSE-2.0
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +000010 *
Holger Hildebrandtfa074992020-03-27 15:42:06 +000011 * Unless required by applicable law or agreed to in writing, software
12 * distributed under the License is distributed on an "AS IS" BASIS,
13 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
14 * See the License for the specific language governing permissions and
15 * limitations under the License.
16 */
Himani Chawlaac1f5ad2021-02-04 21:21:54 +053017/*
Holger Hildebrandtfa074992020-03-27 15:42:06 +000018 * NOTE: This file was generated, manual edits will be overwritten!
19 *
20 * Generated by 'goCodeGenerator.py':
21 * https://github.com/cboling/OMCI-parser/README.md
22 */
23
24package generated
25
26import "github.com/deckarep/golang-set"
27
28// CircuitPackClassID is the 16-bit ID for the OMCI
29// Managed entity Circuit pack
mpagenko836a1fd2021-11-01 16:12:42 +000030const CircuitPackClassID = ClassID(6) // 0x0006
Holger Hildebrandtfa074992020-03-27 15:42:06 +000031
32var circuitpackBME *ManagedEntityDefinition
33
mpagenko836a1fd2021-11-01 16:12:42 +000034// CircuitPack (Class ID: #6 / 0x0006)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000035// This ME models a real or virtual circuit pack that is equipped in a real or virtual ONU slot.
36// For ONUs with integrated interfaces, this ME may be used to distinguish available types of
37// interfaces (the port-mapping package is another way).
38//
39// For ONUs with integrated interfaces, the ONU automatically creates an instance of this ME for
40// each instance of the virtual cardholder ME. The ONU also creates an instance of this ME when the
41// OLT provisions the cardholder to expect a circuit pack, i.e., when the OLT sets the expected
42// plug-in unit type or equipment ID of the cardholder to a circuit pack type, as defined in Table
43// 9.1.5-1. The ONU also creates an instance of this ME when a circuit pack is installed in a
44// cardholder whose expected plug-in unit type is 255-= plugandplay, and whose equipment ID is not
45// provisioned. Finally, when the cardholder is provisioned for plug-and-play, an instance of this
46// ME can be created at the request of the OLT.
47//
48// The ONU deletes an instance of this ME when the OLT de-provisions the circuit pack (i.e., when
49// the OLT sets the expected plug-in unit type or equipment ID of the cardholder to 0-= no LIM).
50// The ONU also deletes an instance of this ME on request of the OLT if the expected plug-in unit
51// type attribute of the corresponding cardholder is equal to 255, plug-and-play, and the expected
52// equipment ID is blank (a string of all spaces). ONUs with integrated interfaces do not delete
53// circuit pack instances.
54//
55// NOTE - Creation and deletion by the OLT is retained for backward compatibility.
56//
57// Relationships
58// An instance of this ME is contained by an instance of the cardholder ME.
59//
60// Attributes
61// Managed Entity Id
mpagenko836a1fd2021-11-01 16:12:42 +000062// This attribute uniquely identifies each instance of this ME. Its value is the same as that of
63// the cardholder ME containing this circuit pack instance. (R, setbycreate if applicable)
64// (mandatory) (2-bytes)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000065//
66// Type
mpagenko836a1fd2021-11-01 16:12:42 +000067// This attribute identifies the circuit pack type. This attribute is a code as defined in Table
68// 9.1.5-1. The value 255 means unknown or undefined, i.e., the inserted circuit pack is not
Holger Hildebrandtfa074992020-03-27 15:42:06 +000069// recognized by the ONU or is not mapped to an entry in Table 9.1.5-1. In the latter case, the
70// equipment ID attribute may contain inventory information. Upon autonomous ME instantiation, the
71// ONU sets this attribute to 0 or to the type of the circuit pack that is physically present. (R,
72// setbycreate if applicable) (mandatory) (1-byte)
73//
74// Number Of Ports
mpagenko836a1fd2021-11-01 16:12:42 +000075// This attribute is the number of access ports on the circuit pack. If the port-mapping package is
76// supported for this circuit pack, this attribute should be set to the total number of ports of
77// all types. (R) (optional) (1-byte)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000078//
79// Serial Number
mpagenko836a1fd2021-11-01 16:12:42 +000080// The serial number is expected to be unique for each circuit pack, at least within the scope of
81// the given vendor. Note that the serial number may contain the vendor ID or version number. For
82// integrated ONUs, this value is identical to the value of the serial number attribute of the
83// ONU-G ME. Upon creation in the absence of a physical circuit pack, this attribute comprises all
84// spaces. (R) (mandatory) (8-bytes)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000085//
86// Version
mpagenko836a1fd2021-11-01 16:12:42 +000087// This attribute is a string that identifies the version of the circuit pack as defined by the
88// vendor. The value 0 indicates that version information is not available or applicable. For
89// integrated ONUs, this value is identical to the value of the version attribute of the ONU-G ME.
90// Upon creation in the absence of a physical circuit pack, this attribute comprises all spaces.
91// (R) (mandatory) (14-bytes)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000092//
93// Vendor Id
mpagenko836a1fd2021-11-01 16:12:42 +000094// This attribute identifies the vendor of the circuit pack. For ONUs with integrated interfaces,
95// this value is identical to the value of the vendor ID attribute of the ONU-G ME. Upon creation
96// in the absence of a physical circuit pack, this attribute comprises all spaces. (R) (optional)
97// (4-bytes)
Holger Hildebrandtfa074992020-03-27 15:42:06 +000098//
99// Administrative State
mpagenko836a1fd2021-11-01 16:12:42 +0000100// This attribute locks (1) and unlocks (0) the functions performed by this ME. Administrative
101// state is further described in clause A.1.6. (R,-W) (mandatory) (1-byte)
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000102//
103// Operational State
mpagenko836a1fd2021-11-01 16:12:42 +0000104// This attribute indicates whether the circuit pack is capable of performing its function. Valid
105// values are enabled (0), disabled (1) and unknown (2). Pending completion of initialization and
106// self-test on an installed circuit pack, the ONU sets this attribute to 2. (R) (optional)
107// (1-byte)
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000108//
109// Bridged Or Ip Ind
mpagenko836a1fd2021-11-01 16:12:42 +0000110// This attribute specifies whether an Ethernet interface is bridged or derived from an IP router
111// function.
112//
113// 0 Bridged
114//
115// 1 IP router
116//
117// 2 Both bridged and IP router functions
118//
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000119// (R,-W) (optional, only applicable for circuit packs with Ethernet interfaces) (1-byte)
120//
121// Equipment Id
mpagenko836a1fd2021-11-01 16:12:42 +0000122// This attribute may be used to identify the vendor's specific type of circuit pack. In some
123// environments, this attribute may include the CLEI code. Upon ME instantiation, the ONU sets this
124// attribute to all spaces or to the equipment ID of the circuit pack that is physically present.
125// (R) (optional) (20-bytes)
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000126//
127// Card Configuration
mpagenko836a1fd2021-11-01 16:12:42 +0000128// This attribute selects the appropriate configuration of configurable circuit packs. Table
129// 9.1.5-1 specifies two configurable card types: C-DS1/E1 (code 16), and C-DS1/E1/J1 (code 17).
130// Values are indicated below for the allowed card types and configurations.
131//
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000132// Upon autonomous instantiation, this attribute is set to 0. (R,-W, setbycreate if applicable)
133// (mandatory for configurable circuit packs) (1-byte)
134//
135// Total T_Cont Buffer Number
136// Total T-CONT buffer number: This attribute reports the total number of T-CONT buffers associated
137// with the circuit pack. Upon ME instantiation, the ONU sets this attribute to 0 or to the value
138// supported by the physical circuit pack. (R) (mandatory for circuit packs that provide a traffic
139// scheduler function) (1-byte)
140//
141// Total Priority Queue Number
mpagenko836a1fd2021-11-01 16:12:42 +0000142// This value reports the total number of priority queues associated with the circuit pack. Upon ME
143// instantiation, the ONU sets the attribute to 0 or to the value supported by the physical circuit
144// pack. (R) (mandatory for circuit packs that provide a traffic scheduler function) (1-byte)
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000145//
146// Total Traffic Scheduler Number
mpagenko836a1fd2021-11-01 16:12:42 +0000147// This value reports the total number of traffic schedulers associated with the circuit pack. The
148// ONU supports null function, strict priority scheduling and WRR from the priority control, and
149// guarantee of minimum rate control points of view. If the circuit pack has no traffic scheduler,
150// this attribute should be absent or have the value 0. Upon ME instantiation, the ONU sets the
151// attribute to 0 or to the value supported by the physical circuit pack. (R) (mandatory for
152// circuit packs that provide a traffic scheduler function) (1-byte)
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000153//
154// Power Shed Override
mpagenko836a1fd2021-11-01 16:12:42 +0000155// This attribute allows ports to be excluded from the power shed control defined in clause 9.1.7.
156// It is a bit mask that takes port 1 as the MSB; a bit value of 1 marks the corresponding port to
157// override the power shed timer. For hardware that cannot shed power per port, this attribute is a
158// slot override rather than a port override, with any non-zero port value causing the entire
159// circuit pack to override power shedding. (R,-W) (optional) (4-bytes)
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000160//
161type CircuitPack struct {
162 ManagedEntityDefinition
163 Attributes AttributeValueMap
164}
165
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +0000166// Attribute name constants
167
168const CircuitPack_Type = "Type"
169const CircuitPack_NumberOfPorts = "NumberOfPorts"
170const CircuitPack_SerialNumber = "SerialNumber"
171const CircuitPack_Version = "Version"
172const CircuitPack_VendorId = "VendorId"
173const CircuitPack_AdministrativeState = "AdministrativeState"
174const CircuitPack_OperationalState = "OperationalState"
175const CircuitPack_BridgedOrIpInd = "BridgedOrIpInd"
176const CircuitPack_EquipmentId = "EquipmentId"
177const CircuitPack_CardConfiguration = "CardConfiguration"
178const CircuitPack_TotalTContBufferNumber = "TotalTContBufferNumber"
179const CircuitPack_TotalPriorityQueueNumber = "TotalPriorityQueueNumber"
180const CircuitPack_TotalTrafficSchedulerNumber = "TotalTrafficSchedulerNumber"
181const CircuitPack_PowerShedOverride = "PowerShedOverride"
182
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000183func init() {
184 circuitpackBME = &ManagedEntityDefinition{
185 Name: "CircuitPack",
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +0000186 ClassID: CircuitPackClassID,
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000187 MessageTypes: mapset.NewSetWith(
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000188 Get,
189 Set,
mpagenko836a1fd2021-11-01 16:12:42 +0000190 Create,
191 Delete,
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000192 ),
193 AllowedAttributeMask: 0xfffc,
194 AttributeDefinitions: AttributeDefinitionMap{
Holger Hildebrandt3ac49bd2022-02-07 17:46:43 +0000195 0: Uint16Field(ManagedEntityID, PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
196 1: ByteField(CircuitPack_Type, EnumerationAttributeType, 0x8000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 1),
197 2: ByteField(CircuitPack_NumberOfPorts, UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read), false, true, false, 2),
198 3: MultiByteField(CircuitPack_SerialNumber, OctetsAttributeType, 0x2000, 8, toOctets("ICAgICAgICA="), mapset.NewSetWith(Read), false, false, false, 3),
199 4: MultiByteField(CircuitPack_Version, OctetsAttributeType, 0x1000, 14, toOctets("ICAgICAgICAgICAgICA="), mapset.NewSetWith(Read), false, false, false, 4),
200 5: MultiByteField(CircuitPack_VendorId, StringAttributeType, 0x0800, 4, toOctets("ICAgIA=="), mapset.NewSetWith(Read), false, true, false, 5),
201 6: ByteField(CircuitPack_AdministrativeState, EnumerationAttributeType, 0x0400, 0, mapset.NewSetWith(Read, Write), false, false, false, 6),
202 7: ByteField(CircuitPack_OperationalState, EnumerationAttributeType, 0x0200, 2, mapset.NewSetWith(Read), true, true, false, 7),
203 8: ByteField(CircuitPack_BridgedOrIpInd, EnumerationAttributeType, 0x0100, 0, mapset.NewSetWith(Read, Write), false, false, false, 8),
204 9: MultiByteField(CircuitPack_EquipmentId, StringAttributeType, 0x0080, 20, toOctets("ICAgICAgICAgICAgICAgICAgICA="), mapset.NewSetWith(Read), false, true, false, 9),
205 10: ByteField(CircuitPack_CardConfiguration, EnumerationAttributeType, 0x0040, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 10),
206 11: ByteField(CircuitPack_TotalTContBufferNumber, UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, false, false, 11),
207 12: ByteField(CircuitPack_TotalPriorityQueueNumber, UnsignedIntegerAttributeType, 0x0010, 0, mapset.NewSetWith(Read), false, false, false, 12),
208 13: ByteField(CircuitPack_TotalTrafficSchedulerNumber, UnsignedIntegerAttributeType, 0x0008, 0, mapset.NewSetWith(Read), false, false, false, 13),
209 14: Uint32Field(CircuitPack_PowerShedOverride, BitFieldAttributeType, 0x0004, 0, mapset.NewSetWith(Read, Write), false, true, false, 14),
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000210 },
mpagenko836a1fd2021-11-01 16:12:42 +0000211 Access: CreatedByOnu,
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000212 Support: UnknownSupport,
Himani Chawlaac1f5ad2021-02-04 21:21:54 +0530213 Alarms: AlarmMap{
214 0: "Equipment alarm",
215 1: "Powering alarm",
216 2: "Self-test failure",
217 3: "Laser end of life",
218 4: "Temperature yellow",
219 5: "Temperature red",
220 },
Holger Hildebrandtfa074992020-03-27 15:42:06 +0000221 }
222}
223
224// NewCircuitPack (class ID 6) creates the basic
225// Managed Entity definition that is used to validate an ME of this type that
226// is received from or transmitted to the OMCC.
227func NewCircuitPack(params ...ParamData) (*ManagedEntity, OmciErrors) {
228 return NewManagedEntity(*circuitpackBME, params...)
229}