blob: 8f832ba9ebd9df01f6f044c14f213ab38f616ef1 [file] [log] [blame]
Gayathri.Selvanee4a91b2020-01-17 06:49:53 +00001# Copyright 2017 - present Open Networking Foundation
2#
3# Licensed under the Apache License, Version 2.0 (the "License");
4# you may not use this file except in compliance with the License.
5# You may obtain a copy of the License at
6#
7# http://www.apache.org/licenses/LICENSE-2.0
8#
9# Unless required by applicable law or agreed to in writing, software
10# distributed under the License is distributed on an "AS IS" BASIS,
11# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
12# See the License for the specific language governing permissions and
13# limitations under the License.
14# FIXME Can we use the same test against BBSim and Hardware?
15
16*** Settings ***
17Documentation Test various end-to-end scenarios
18Suite Setup Common Test Suite Setup
19Test Setup Setup
20Test Teardown Teardown
21#Suite Teardown Teardown Suite
22Library Collections
23Library String
24Library OperatingSystem
25Library XML
26Library RequestsLibrary
27Library ../../libraries/DependencyLibrary.py
28Resource ../../libraries/onos.robot
29Resource ../../libraries/voltctl.robot
30Resource ../../libraries/voltha.robot
31Resource ../../libraries/utils.robot
32Resource ../../libraries/k8s.robot
33Resource ../../variables/variables.robot
34
35*** Variables ***
36${POD_NAME} flex-ocp-cord
37${KUBERNETES_CONF} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf
38${KUBERNETES_CONFIGS_DIR} ~/pod-configs/kubernetes-configs
39#${KUBERNETES_CONFIGS_DIR} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.conf
40${KUBERNETES_YAML} ${KUBERNETES_CONFIGS_DIR}/${POD_NAME}.yml
41${HELM_CHARTS_DIR} ~/helm-charts
42${VOLTHA_POD_NUM} 8
43${NAMESPACE} voltha
44# For below variable value, using deployment name as using grep for
45# parsing radius pod name, we can also use full radius pod name
46${RESTART_POD_NAME} radius
Suchitra Vemurif7a033c2020-02-26 17:22:41 -080047${timeout} 120s
Gayathri.Selvanee4a91b2020-01-17 06:49:53 +000048${of_id} 0
49${logical_id} 0
Suchitra Vemuri2fa9bba2020-01-22 17:38:48 -080050${has_dataplane} True
Gayathri.Selvanee4a91b2020-01-17 06:49:53 +000051${teardown_device} False
52${scripts} ../../scripts
Hardik Windlasscbcca312020-04-20 21:46:11 +053053${workflow} ATT
Gayathri.Selvanee4a91b2020-01-17 06:49:53 +000054
Andy Bavierabeba262020-02-07 16:22:16 -070055# Per-test logging on failure is turned off by default; set this variable to enable
56${container_log_dir} ${None}
57
Gayathri.Selvanee4a91b2020-01-17 06:49:53 +000058*** Test Cases ***
59Adding the same OLT before and after enabling the device
60 [Documentation] Create OLT, Create the same OLT again and Check for the Error message
Suchitra Vemuri9a6dd6d2020-02-28 17:46:26 -080061 ... VOL-2405 VOL-2406
62 [Tags] AddSameOLT functional released
Andy Baviere187eda2020-04-20 15:00:02 -070063 [Setup] Start Logging AddSameOLT
Andy Bavier4a8450e2020-02-04 08:58:37 -070064 [Teardown] Run Keywords Collect Logs
Andy Bavierabeba262020-02-07 16:22:16 -070065 ... AND Stop Logging AddSameOLT
Suchitra Vemurif7a033c2020-02-26 17:22:41 -080066 # Add OLT device
Suchitra Vemurie9c79bf2020-02-26 23:11:39 -080067 #setup
Andy Bavierc1904dc2020-03-20 11:39:15 -070068 Delete All Devices and Verify
Suchitra Vemuri9a6dd6d2020-02-28 17:46:26 -080069 Run Keyword and Ignore Error Collect Logs
Gayathri.Selvanee4a91b2020-01-17 06:49:53 +000070 ${olt_device_id}= Create Device ${olt_ip} ${OLT_PORT}
71 Set Suite Variable ${olt_device_id}
Suchitra Vemuri1d0d0222020-02-12 17:17:19 -080072 ${timeout} Set Variable 180s
Gayathri.Selvanee4a91b2020-01-17 06:49:53 +000073 Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Device PREPROVISIONED UNKNOWN UNKNOWN
ubuntu6b6e7d42020-03-02 12:35:42 -080074 ... ${olt_device_id}
Gayathri.Selvanee4a91b2020-01-17 06:49:53 +000075 ${rc} ${output}= Run and Return Rc and Output
76 ... ${VOLTCTL_CONFIG}; voltctl device create -t openolt -H ${olt_ip}:${OLT_PORT}
77 Should Not Be Equal As Integers ${rc} 0
Hardik Windlassffbf0602020-04-24 23:14:45 +053078 Should Contain ${output} device is already pre-provisioned
Gayathri.Selvanee4a91b2020-01-17 06:49:53 +000079 #Enable the created OLT device
80 Enable Device ${olt_device_id}
81 Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Device ENABLED ACTIVE REACHABLE
82 ... ${olt_serial_number}
83 ${rc} ${output}= Run and Return Rc and Output
84 ... ${VOLTCTL_CONFIG}; voltctl device create -t openolt -H ${olt_ip}:${OLT_PORT}
85 Should Not Be Equal As Integers ${rc} 0
86 Log ${output}
Hardik Windlassffbf0602020-04-24 23:14:45 +053087 Should Contain ${output} device is already pre-provisioned
Gayathri.Selvanee4a91b2020-01-17 06:49:53 +000088 Log "This OLT is added already and enabled"
Gayathri.Selvan3dfe6c22020-01-27 13:08:55 +000089
Gayathri.Selvan967f5a52020-02-12 06:58:38 +000090Test Disable or Enable different device id which is not in the device list
91 [Documentation] Disable or Enable a device id which is not listed in the voltctl device list
Gayathri.Selvan3dfe6c22020-01-27 13:08:55 +000092 ... command and ensure that error message is shown.
Suchitra Vemuria7dae322020-02-19 22:38:18 -080093 ... VOL-2412-2413
94 [Tags] functional DisableEnableInvalidDevice released
Andy Baviere187eda2020-04-20 15:00:02 -070095 [Setup] Start Logging DisableInvalidDevice
Andy Bavier4a8450e2020-02-04 08:58:37 -070096 [Teardown] Run Keywords Collect Logs
Andy Bavierabeba262020-02-07 16:22:16 -070097 ... AND Stop Logging DisableInvalidDevice
Suchitra Vemuri9a6dd6d2020-02-28 17:46:26 -080098 Run Keyword and Ignore Error Collect Logs
Gayathri.Selvan3dfe6c22020-01-27 13:08:55 +000099 ${rc} ${output}= Run and Return Rc and Output ${VOLTCTL_CONFIG}; voltctl device list -o json
100 Should Be Equal As Integers ${rc} 0
101 ${jsondata}= To Json ${output}
102 Log ${jsondata}
103 ${length}= Get Length ${jsondata}
104 @{ids}= Create List
105 FOR ${INDEX} IN RANGE 0 ${length}
106 ${value}= Get From List ${jsondata} ${INDEX}
107 ${device_id}= Get From Dictionary ${value} id
108 Append To List ${ids} ${device_id}
109 END
110 #Create a new fake device id
111 ${fakeDeviceId} Replace String Using Regexp ${device_id} \\d\\d xx count=1
112 Log ${fakeDeviceId}
113 #Ensure that the new id created is not in the device id list
114 List Should Not Contain Value ${ids} ${fakeDeviceId}
115 #Disable fake device id
116 ${rc} ${output}= Run and Return Rc and Output ${VOLTCTL_CONFIG}; voltctl device disable ${fakeDeviceId}
Suchitra Vemuria7e8ad22020-02-11 18:02:40 -0800117 Should Contain ${output} Error while disabling '${fakeDeviceId}'
Gayathri.Selvan967f5a52020-02-12 06:58:38 +0000118 #Disable device for VOL-2413
119 Disable Device ${device_id}
120 #Enable fake device id
121 ${rc} ${output}= Run and Return Rc and Output ${VOLTCTL_CONFIG}; voltctl device enable ${fakeDeviceId}
122 Should Contain ${output} Error while enabling '${fakeDeviceId}'
suraj gourbaee2c62020-02-03 10:21:32 +0000123
124Check deletion of OLT/ONU before disabling
125 [Documentation] Try deleting OL/ONU before disabling and check error message
126 ... Assuming devices are already created, up and running fine; test1 or sanity was
127 ... executed where all the ONUs are authenticated/DHCP/pingable
Suchitra Vemuri9a6dd6d2020-02-28 17:46:26 -0800128 ... VOL-2411
Hardik Windlasscbcca312020-04-20 21:46:11 +0530129 #TODO: If this TC gets updated in future, To add support for DT workflow as well (refer JIRA: VOL-2945)
Suchitra Vemuri9a6dd6d2020-02-28 17:46:26 -0800130 [Tags] functional DeleteBeforeDisableCheck notready
Andy Baviere187eda2020-04-20 15:00:02 -0700131 [Setup] Start Logging DeleteBeforeDisableCheck
Andy Bavier4a8450e2020-02-04 08:58:37 -0700132 [Teardown] Run Keywords Collect Logs
Andy Bavierabeba262020-02-07 16:22:16 -0700133 ... AND Stop Logging DeleteBeforeDisableCheck
suraj gourbaee2c62020-02-03 10:21:32 +0000134 #validate olt states
Suchitra Vemuri9a6dd6d2020-02-28 17:46:26 -0800135 Run Keyword If ${has_dataplane} Clean Up Linux
136 Wait Until Keyword Succeeds ${timeout} 2s Perform Sanity Test
suraj gourbaee2c62020-02-03 10:21:32 +0000137 Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Device ENABLED ACTIVE REACHABLE
138 ... ${olt_serial_number}
139 ${rc} ${output}= Run and Return Rc and Output ${VOLTCTL_CONFIG}; voltctl device delete ${olt_device_id}
140 Log ${output}
141 Should Contain ${output} expected-admin-state:DISABLED
142 Wait Until Keyword Succeeds ${timeout} 5s
143 ... Validate OLT Device ENABLED ACTIVE REACHABLE ${olt_serial_number}
144 ${of_id}= Wait Until Keyword Succeeds ${timeout} 15s Validate OLT Device in ONOS ${olt_serial_number}
145 Set Global Variable ${of_id}
146 FOR ${I} IN RANGE 0 ${num_onus}
147 ${src}= Set Variable ${hosts.src[${I}]}
148 ${dst}= Set Variable ${hosts.dst[${I}]}
149 ${onu_device_id}= Get Device ID From SN ${src['onu']}
150 Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s Validate Device
151 ... ENABLED ACTIVE REACHABLE
152 ... ${src['onu']} onu=True onu_reason=omci-flows-pushed
153 ${rc} ${output}= Run and Return Rc and Output ${VOLTCTL_CONFIG}; voltctl device delete ${onu_device_id}
154 Log ${output}
155 Should Contain ${output} expected-admin-state:DISABLED
156 Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s Validate Device
157 ... ENABLED ACTIVE REACHABLE
158 ... ${src['onu']} onu=True onu_reason=omci-flows-pushed
159 END
suraj gourb3160412020-02-04 06:11:31 +0000160
161Check disabling of pre-provisioned OLT before enabling
162 [Documentation] Create OLT, disable same OLT, check error message and validates ONU
Suchitra Vemuri9a6dd6d2020-02-28 17:46:26 -0800163 ... VOL-2414
164 [Tags] functional DisablePreprovisionedOLTCheck
Andy Baviere187eda2020-04-20 15:00:02 -0700165 [Setup] Run Keywords Start Logging DisablePreprovisionedOLTCheck
Andy Bavierde53a1f2020-03-25 14:53:56 -0700166 ... AND Delete All Devices and Verify
Andy Bavier4a8450e2020-02-04 08:58:37 -0700167 [Teardown] Run Keywords Collect Logs
Andy Bavierabeba262020-02-07 16:22:16 -0700168 ... AND Stop Logging DisablePreprovisionedOLTCheck
Andy Bavierde53a1f2020-03-25 14:53:56 -0700169 Sleep 180s
Suchitra Vemuri9a6dd6d2020-02-28 17:46:26 -0800170 Run Keyword and Ignore Error Collect Logs
suraj gourb3160412020-02-04 06:11:31 +0000171 #create/preprovision device
172 ${olt_device_id}= Create Device ${olt_ip} ${OLT_PORT}
173 Set Suite Variable ${olt_device_id}
174 #validate olt states
175 Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Device PREPROVISIONED UNKNOWN UNKNOWN
ubuntu6b6e7d42020-03-02 12:35:42 -0800176 ... ${olt_device_id}
suraj gourb3160412020-02-04 06:11:31 +0000177 #Try disabling pre-provisioned OLT
178 ${rc} ${output}= Run and Return Rc and Output ${VOLTCTL_CONFIG}; voltctl device disable ${olt_device_id}
Andy Bavierde53a1f2020-03-25 14:53:56 -0700179 Should Not Be Equal As Integers ${rc} 0
suraj gourb3160412020-02-04 06:11:31 +0000180 Log ${output}
181 Should Contain ${output} invalid-admin-state:PREPROVISIONED
182 #Enable OLT
183 Enable Device ${olt_device_id}
184 Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Device ENABLED ACTIVE REACHABLE
185 ... ${olt_serial_number}
186 ${logical_id}= Get Logical Device ID From SN ${olt_serial_number}
187 Set Suite Variable ${logical_id}
Hardik Windlasscbcca312020-04-20 21:46:11 +0530188 ${onu_reason}= Set Variable If '${workflow}' == 'DT' initial-mib-downloaded omci-flows-pushed
suraj gourb3160412020-02-04 06:11:31 +0000189 FOR ${I} IN RANGE 0 ${num_onus}
190 ${src}= Set Variable ${hosts.src[${I}]}
191 ${dst}= Set Variable ${hosts.dst[${I}]}
192 Run Keyword And Continue On Failure Wait Until Keyword Succeeds ${timeout} 5s Validate Device
193 ... ENABLED ACTIVE REACHABLE
Hardik Windlasscbcca312020-04-20 21:46:11 +0530194 ... ${src['onu']} onu=True onu_reason=${onu_reason}
suraj gourb3160412020-02-04 06:11:31 +0000195 END
Hema526eceb2020-02-04 13:11:40 +0530196
197Disable and Delete the logical device directly
198 [Documentation] Disable and delete the logical device directly is not possible
199 ... since it is allowed only through OLT device deletion.
Suchitra Vemuri5f66f422020-03-02 16:43:49 -0800200 ... VOL-2418
201 [Tags] functional DisableDelete_LogicalDevice
Andy Baviere187eda2020-04-20 15:00:02 -0700202 [Setup] Run Keywords Start Logging DisableDelete_LogicalDevice
Andy Bavierde53a1f2020-03-25 14:53:56 -0700203 ... AND Delete All Devices and Verify
Andy Bavier4a8450e2020-02-04 08:58:37 -0700204 [Teardown] Run Keywords Collect Logs
Andy Bavierabeba262020-02-07 16:22:16 -0700205 ... AND Stop Logging DisableDelete_LogicalDevice
Hema526eceb2020-02-04 13:11:40 +0530206 Run Keyword If ${has_dataplane} Sleep 180s
207 #create/preprovision OLT device
208 ${olt_device_id}= Create Device ${olt_ip} ${OLT_PORT}
209 Set Suite Variable ${olt_device_id}
210 #validate olt states
211 Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Device PREPROVISIONED UNKNOWN UNKNOWN
ubuntu6b6e7d42020-03-02 12:35:42 -0800212 ... ${olt_device_id}
Hema526eceb2020-02-04 13:11:40 +0530213 #Enable the created OLT device
214 Enable Device ${olt_device_id}
215 Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Device ENABLED ACTIVE REACHABLE
216 ... ${olt_serial_number}
217 #Check whether logical devices are also created
218 ${rc} ${output}= Run and Return Rc and Output
219 ... ${VOLTCTL_CONFIG}; voltctl logicaldevice list
220 Should Be Equal As Integers ${rc} 0
221 Log ${output}
222 ${logical_id}= Get Logical Device ID From SN ${olt_serial_number}
223 Should Not Be Empty ${logical_id}
224 ${rc} ${output}= Run and Return Rc and Output
225 ... ${VOLTCTL_CONFIG}; voltctl logicaldevice disable ${logical_id}
Andy Bavierde53a1f2020-03-25 14:53:56 -0700226 Should Not Be Equal As Integers ${rc} 0
Hema526eceb2020-02-04 13:11:40 +0530227 Log ${output}
228 Should Contain '${output}' Unknown command
229 ${rc} ${output1}= Run and Return Rc and Output
230 ... ${VOLTCTL_CONFIG}; voltctl logicaldevice delete ${logical_id}
Andy Bavierde53a1f2020-03-25 14:53:56 -0700231 Should Not Be Equal As Integers ${rc} 0
Hema526eceb2020-02-04 13:11:40 +0530232 Log ${output1}
233 Should Contain '${output1}' Unknown command
suraj goura4166222020-02-03 12:09:11 +0000234
235Check logical device creation and deletion
236 [Documentation] Deletes all devices, checks logical device, creates devices again and checks
237 ... logical device, flows, ports
Suchitra Vemuri5f66f422020-03-02 16:43:49 -0800238 ... VOL-2416 VOL-2417
239 [Tags] functional LogicalDeviceCheck
Andy Baviere187eda2020-04-20 15:00:02 -0700240 [Setup] Start Logging LogicalDeviceCheck
Andy Bavier4a8450e2020-02-04 08:58:37 -0700241 [Teardown] Run Keywords Collect Logs
Andy Bavierabeba262020-02-07 16:22:16 -0700242 ... AND Stop Logging LogicalDeviceCheck
Andy Bavierde53a1f2020-03-25 14:53:56 -0700243 Delete All Devices and Verify
suraj goura4166222020-02-03 12:09:11 +0000244 ${logical_id}= Get Logical Device ID From SN ${olt_serial_number}
245 Should Be Empty ${logical_id}
246 Run Keyword If ${has_dataplane} Sleep 180s
247 ${olt_device_id}= Create Device ${olt_ip} ${OLT_PORT}
248 Set Suite Variable ${olt_device_id}
249 Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Device PREPROVISIONED UNKNOWN UNKNOWN
ubuntu6b6e7d42020-03-02 12:35:42 -0800250 ... ${olt_device_id}
suraj goura4166222020-02-03 12:09:11 +0000251 Enable Device ${olt_device_id}
252 Wait Until Keyword Succeeds ${timeout} 5s Validate OLT Device ENABLED ACTIVE REACHABLE
253 ... ${olt_serial_number}
254 ${logical_id}= Get Logical Device ID From SN ${olt_serial_number}
255 Should Not Be Empty ${logical_id}
256 ${rc} ${output}= Run and Return Rc and Output
257 ... ${VOLTCTL_CONFIG}; voltctl logicaldevice list
258 Should Be Equal As Integers ${rc} 0
259 Log ${output}
260 Should Contain ${output} ${olt_device_id}
261 Set Suite Variable ${logical_id}
262 Wait Until Keyword Succeeds ${timeout} 5s Validate Logical Device Ports ${logical_id}
263 Wait Until Keyword Succeeds ${timeout} 5s Validate Logical Device Flows ${logical_id}
264 Run Keyword and Ignore Error Collect Logs
Suchitra Vemurie9c79bf2020-02-26 23:11:39 -0800265
266*** Keywords ***
267Setup Suite
268 [Documentation] Set up the test suite
269 Common Test Suite Setup
270
Suchitra Vemuri1d8e8172020-06-17 17:43:56 -0700271#Teardown Suite
272# [Documentation] Teardown suite
273 #Restore all ONUs